• Title/Summary/Keyword: Appropriate technology

Search Result 5,580, Processing Time 0.04 seconds

Evaluation of the Image Quality According to the Pre-set Method in PET/CT Image (PET/CT 영상 획득 시 사전설정법 차이에 따른 영상 질 평가)

  • Park, Sun-Myung;Lee, Hyuk;Hong, Gun-Chul;Chung, Eun-Kyung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.41-46
    • /
    • 2011
  • Purpose: The result of exam using an imaging device is very closely related with the image quality. Moreover, this image quality can be changed according to the condition of image acquisition and evaluation method. In this study, we evaluated the image quality according to the difference of pre-set method in PET/CT image. Materials & Methods: PET/CT Discovery STe16 (GE Healthcare, Milwaukee, USA), Chest PET phantom (Experiment 1) and 94 NEMA phantom (Experiment 2) were used. Phantom were filled with $^{18}F$-FDG maintaining hot sphere and background ratio to 4:1. In the case of experiment 1, we set the radio activity concentration on 3.5, 6.0, 8.6 kBq/mL. In the case of experiment 2, we set the radio activity concentration on 3.3, 5.5, 7.7, 9.9, 12.1, 16.5 kBq/mL. All experiments were performed with the time-set method for 2 minutes 30 seconds per frame and the count-set method with one hundred million counts in 3D mode after CT transmission scan. For the evaluation of the image quality, we compared each results by using the NECR and SNR. Results: In the experiment 1, both the NECR and SNR were increased as radioactivity concentration getting increased. The NECR was shown as 53.7, 66.9, 91.4. and SNR was shown as 7.9, 10.0, 11.7. Both the NECR and SNR were increased in time-set method. But the count-set method's pattern was not similar with the time-set method. The NECR was shown as 53.8, 69.1, 97.8, and SNR was shown as 14.1, 14.7 14.4. The SNR was not increased in count-set method. In experiment 2, results of both the NECR and SNR were shown as 45.1, 70.6, 95.3, 115.6, 134.6, 162.2 and 7.1, 8.8, 10.6, 11.5, 12.7, 14.0. These results were shown similar patten with the experiment 1. Moreover, when the count-set method was applied, the NECR was shown as 42.1, 67.3, 92.1, 112.2, 130.7, 158.7, and SNR was shown as 15.2, 15.9, 15.6, 15.4, 15.5, 14.9. The NECR was increased but SNR was not shown same pattern. Conclusion: Increment of administered radioactivity improves the quality of image unconcerned with the pre-set method. However, NECR was not influenced by increment of total acquisition counts through simple increasing scan duration without increment of administered activity. In case of count-set method, the SNR was shown similar value despite of increment of radioactivity. So, the administered activity is more important than the scan duration. And we have to consider that evaluation of image quality using only SNR may not be appropriate.

  • PDF

Effect of Cooling Timing in the Root Zone on Substrate Temperature and Physiological Response of Sweet Pepper in Summer Cultivation (여름 파프리카 수경재배에서 근권 냉방 시간이 근권 온도와 생리적 반응에 미치는 영향)

  • Choi, Ki Young;Ko, Ji Yeon;Yoo, Hyung Joo;Choi, Eun Young;Rhee, Han Cheol;Lee, Yong-Beom
    • Horticultural Science & Technology
    • /
    • v.32 no.1
    • /
    • pp.53-59
    • /
    • 2014
  • This study aimed to determine an appropriate cooling timing in the root zone for lowering substrate temperature and its effect on physiological response of sweet pepper (Capsicum annum L. 'Orange glory') grown on coir substrate in summer, from the July 16 to October 15, 2012. Daily temperature of substrate, root activity, leaf water potential, first flowering date, and the number of fruits were measured by circulating cool water through a XL pipe in the root zone during either all day (all-day) or only night time (5 p.m. to 3 a.m.; night) from the July 23 to September 23, 2012. For comparison, no cooling (control) was also applied. Between the $23^{rd}$ of July and $31^{st}$ of August (hot temperature period), daily average temperatures in substrates were $25.6^{\circ}C$, $26.1^{\circ}C$, and $29.1^{\circ}C$ for the all-day and night treatment, and control respectively. About 1.8 to $5^{\circ}C$ lower substrate temperature was observed in both treatments compared to that of control. In sunny day ($600-700 W{\cdot}m^{-2}{\cdot}s^{-1}$), the highest temperature of substrate was measured between 4 p.m. and 5 p.m. under both the all-day and night treatments, whereas it was measured between 7 p.m. and 8 p.m. under the control. Substrate temperatures during the day (6 a.m. to 8 p.m.) and night (8 p.m. to 6 a.m.) differed depending on the treatments. During the day and night, averaged substrate temperature was lower about $3.3^{\circ}C$ and $4.0^{\circ}C$ for the all-day, and $2.1^{\circ}C$ and $3.4^{\circ}C$ for the night treatment, compared to that of control. In the all-day and night treatment, the TD [TD = temperature of (control)] was greater in bottom than that of other regions of the substrate. Between the day and night, no different TD values were observed under the all-day treatment, whereas under the night treatment there was difference with the greatest degree in the bottom of the substrate. During the hot temperature period, total numbers of days when substrate temperature was over $25^{\circ}C$ were 40, 23 and 27 days for the control, all-day, and night treatment, respectively, and the effect of lowering substrate temperature was therefore 42.5% and 32.5% for the all-day and night treatment, respectively, compared to that for the control. Root activity and leaf water potential of plants grown under the all-day treatment were significantly higher than those under the night treatment. The first flowering date in the all-day treatment was similar to that in the night treatment, but 4-5 day faster than in the control. Also, the number of fruits in both treatments was significantly higher than that in the control. However, there was no effect of root zone cooling on eliminating delay in fruiting caused by excessively higher air temperature (> $30^{\circ}C$), although the substrate temperature was reduced $18^{\circ}C$ to $5^{\circ}C$. These results suggest that the method of cooling root zone temperature need to be incorporated into the lowering growing temperature for growth and fruit set of health paprika.

An Empirical Study on the Determinants of Supply Chain Management Systems Success from Vendor's Perspective (참여자관점에서 공급사슬관리 시스템의 성공에 영향을 미치는 요인에 관한 실증연구)

  • Kang, Sung-Bae;Moon, Tae-Soo;Chung, Yoon
    • Asia pacific journal of information systems
    • /
    • v.20 no.3
    • /
    • pp.139-166
    • /
    • 2010
  • The supply chain management (SCM) systems have emerged as strong managerial tools for manufacturing firms in enhancing competitive strength. Despite of large investments in the SCM systems, many companies are not fully realizing the promised benefits from the systems. A review of literature on adoption, implementation and success factor of IOS (inter-organization systems), EDI (electronic data interchange) systems, shows that this issue has been examined from multiple theoretic perspectives. And many researchers have attempted to identify the factors which influence the success of system implementation. However, the existing studies have two drawbacks in revealing the determinants of systems implementation success. First, previous researches raise questions as to the appropriateness of research subjects selected. Most SCM systems are operating in the form of private industrial networks, where the participants of the systems consist of two distinct groups: focus companies and vendors. The focus companies are the primary actors in developing and operating the systems, while vendors are passive participants which are connected to the system in order to supply raw materials and parts to the focus companies. Under the circumstance, there are three ways in selecting the research subjects; focus companies only, vendors only, or two parties grouped together. It is hard to find researches that use the focus companies exclusively as the subjects probably due to the insufficient sample size for statistic analysis. Most researches have been conducted using the data collected from both groups. We argue that the SCM success factors cannot be correctly indentified in this case. The focus companies and the vendors are in different positions in many areas regarding the system implementation: firm size, managerial resources, bargaining power, organizational maturity, and etc. There are no obvious reasons to believe that the success factors of the two groups are identical. Grouping the two groups also raises questions on measuring the system success. The benefits from utilizing the systems may not be commonly distributed to the two groups. One group's benefits might be realized at the expenses of the other group considering the situation where vendors participating in SCM systems are under continuous pressures from the focus companies with respect to prices, quality, and delivery time. Therefore, by combining the system outcomes of both groups we cannot measure the system benefits obtained by each group correctly. Second, the measures of system success adopted in the previous researches have shortcoming in measuring the SCM success. User satisfaction, system utilization, and user attitudes toward the systems are most commonly used success measures in the existing studies. These measures have been developed as proxy variables in the studies of decision support systems (DSS) where the contribution of the systems to the organization performance is very difficult to measure. Unlike the DSS, the SCM systems have more specific goals, such as cost saving, inventory reduction, quality improvement, rapid time, and higher customer service. We maintain that more specific measures can be developed instead of proxy variables in order to measure the system benefits correctly. The purpose of this study is to find the determinants of SCM systems success in the perspective of vendor companies. In developing the research model, we have focused on selecting the success factors appropriate for the vendors through reviewing past researches and on developing more accurate success measures. The variables can be classified into following: technological, organizational, and environmental factors on the basis of TOE (Technology-Organization-Environment) framework. The model consists of three independent variables (competition intensity, top management support, and information system maturity), one mediating variable (collaboration), one moderating variable (government support), and a dependent variable (system success). The systems success measures have been developed to reflect the operational benefits of the SCM systems; improvement in planning and analysis capabilities, faster throughput, cost reduction, task integration, and improved product and customer service. The model has been validated using the survey data collected from 122 vendors participating in the SCM systems in Korea. To test for mediation, one should estimate the hierarchical regression analysis on the collaboration. And moderating effect analysis should estimate the moderated multiple regression, examines the effect of the government support. The result shows that information system maturity and top management support are the most important determinants of SCM system success. Supply chain technologies that standardize data formats and enhance information sharing may be adopted by supply chain leader organization because of the influence of focal company in the private industrial networks in order to streamline transactions and improve inter-organization communication. Specially, the need to develop and sustain an information system maturity will provide the focus and purpose to successfully overcome information system obstacles and resistance to innovation diffusion within the supply chain network organization. The support of top management will help focus efforts toward the realization of inter-organizational benefits and lend credibility to functional managers responsible for its implementation. The active involvement, vision, and direction of high level executives provide the impetus needed to sustain the implementation of SCM. The quality of collaboration relationships also is positively related to outcome variable. Collaboration variable is found to have a mediation effect between on influencing factors and implementation success. Higher levels of inter-organizational collaboration behaviors such as shared planning and flexibility in coordinating activities were found to be strongly linked to the vendors trust in the supply chain network. Government support moderates the effect of the IS maturity, competitive intensity, top management support on collaboration and implementation success of SCM. In general, the vendor companies face substantially greater risks in SCM implementation than the larger companies do because of severe constraints on financial and human resources and limited education on SCM systems. Besides resources, Vendors generally lack computer experience and do not have sufficient internal SCM expertise. For these reasons, government supports may establish requirements for firms doing business with the government or provide incentives to adopt, implementation SCM or practices. Government support provides significant improvements in implementation success of SCM when IS maturity, competitive intensity, top management support and collaboration are low. The environmental characteristic of competition intensity has no direct effect on vendor perspective of SCM system success. But, vendors facing above average competition intensity will have a greater need for changing technology. This suggests that companies trying to implement SCM systems should set up compatible supply chain networks and a high-quality collaboration relationship for implementation and performance.

Research and Development Trends on Omega-3 Fatty Acid Fortified Foodstuffs (오메가 3계 지방산 강화 식품류의 연구개발 동향)

  • 이희애;유익종;이복희
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.26 no.1
    • /
    • pp.161-174
    • /
    • 1997
  • Omega-3 fatty acids have been major research interests in medical and nutritional science relating to life sciences since after the epidemiologic data on Green3and Eskimos reported by several researchers clearly showed fewer per capita deaths from heart diseases and a lower incidence of adult diseases. Linolenic acid(LNA) is an essential fatty acid for human beings as well as linoleic acid(LA) due to the fact that vertebrates lack an enzyme required to incorporate a double bond beyond carbon 9 in the chain. In addition the ratio of omega-6 and 3 fatty acids seems to be important in terms of alleviation of heart diseases since LA and LNA competes for the metabolic pathways of eicosanoids synthesis. High consumption of omega-3 fatty acids in seafoods may control heart diseases by reducing blood cholesterol, triglyceride, VLDL, LDL and increasing HDL and by inhibiting plaque development through the formation of antiaggregatory substances like PGI$_2$, PGI$_3$ and TXA$_3$ metabolized from LNA. Omega 3 fatty acids also play an important role in neuronal developments and visual functioning, in turn influence learning behaviors. Current dietary sources of omega-3 fatty acids are limited mostly to seafoods, leafy vegetables, marine and some seed oils and the most appropriate way to provide omega-3 fatty acids is as a part of the normal dietary regimen. The efforts to enhance the intake of omega-3 fatty acids due to several beneficial effects have been made nowadays by way of food processing technology. Two different ways can be applied: one is add Purified and concentrated omega-3 fatty acids into foods and the other is to produce foods with high amounts of omega-3 fatty acids by raising animals with specially formulated feed best for the transfer of omega-3 fatty acids. Recently, items of manufactured and marketed omega-3 fatty acids fortified foodstuffs are pork, milk, cheese, egg, formula milk and ham. In domestic food market, many of them are distributed already, but problem is that nutritional informations on the amounts of omega-3 fatty acids are not presented on the labeling, which might cause distrust of consumers on those products, result in lower sales volumes. It would be very much wise if we consume natural products, result in lower sales volumes. It would be very much wise if we consume natural products high in omega-3 fatty acids to Promote health related to many types of adult diseases rather than processed foods fortified with omega-3 fatty acids.

  • PDF

A Consideration of Apron's Shielding in Nuclear Medicine Working Environment (PET검사 작업환경에 있어서 APRON의 방어에 대한 고찰)

  • Lee, Seong-wook;Kim, Seung-hyun;Ji, Bong-geun;Lee, Dong-wook;Kim, Jeong-soo;Kim, Gyeong-mok;Jang, Young-do;Bang, Chan-seok;Baek, Jong-hoon;Lee, In-soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.110-114
    • /
    • 2014
  • Purpose: The advancement in PET/CT test devices has decreased the test time and popularized the test, and PET/CT tests have continuously increased. However, this increases the exposure dose of radiation workers, too. This study aims to measure the radiation shielding rate of $^{18}F-FDG$ with a strong energy and the shielding effect when worker wore an apron during the PET/CT test. Also, this study compared the shielding rate with $^{99m}TC$ to minimize the exposure dose of radiation workers. Materials and Methods: This study targeted 10 patients who visited in this hospital for the PET/CT test for 8 days from May 2nd to 10th 2013, and the $^{18}F-FDG$ distribution room, patient relaxing room (stand by room after $^{18}F-FDG$ injection) and PET/CT test room were chosen as measuring spots. Then, the changes in the dose rate were measured before and after the application of the APRON. For an accurate measurement, the distance from patients or sources was fixed at 1M. Also, the same method applied to $^{99m}TC's$ Source in order to compare the reduction in the dose by the Apron. Results: 1) When there was only L-block in the $^{18}F-FDG$ distribution room, the average dose rate was $0.32{\mu}Sv$, and in the case of L-blockK+ apron, it was $0.23{\mu}Sv$. The differences in the dose and dose rate between the two cases were respectively, $0.09{\mu}Sv$ and 26%. 2) When there was no apron in the relaxing room, the average dose rate was $33.1{\mu}Sv$, and when there was an apron, it was $22.3{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $10.8{\mu}Sv$ and 33%. 3) When there was no APRON in the PET/CT room, the average dose rate was $6.9{\mu}Sv$, and there was an APRON, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $1.4{\mu}Sv$ and 25%. 4) When there was no apron, the average dose rate of $^{99m}TC$ was $23.7{\mu}Sv$, and when there was an apron, it was $5.5{\mu}Sv$. The differences in the dose and dose rate between them were respectively, $18.2{\mu}Sv$ and 77%. Conclusion: According to the result of the experiment, $^{99m}TC$ injected into patients showed an average shielding rate of 77%, and $^{18F}FDG$ showed a relatively low shielding rate of 27%. When comparing the sources only, $^{18F}FDG$ showed a shielding rate of 17%, and $^{99m}TC$'s was 77%. Though it had a lower shielding effect than $^{99m}TC$, $^{18}F-FDG$ also had a shielding effect on the apron. Therefore, it is considered that wearing an apron appropriate for high energy like $^{18}F-FDG$ would minimize the exposure dose of radiation workers.

  • PDF

Approach to the Extraction Method on Minerals of Ginseng Extract (추출조건(抽出條件)에 따른 인삼(人蔘)엑기스의 무기성분정량(無機成分定量)에 관(關)한 연구(硏究))

  • Cho, Han-Ok;Lee, Joong-Hwa;Cho, Sung-Hwan;Choi, Young-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.8 no.2
    • /
    • pp.95-106
    • /
    • 1976
  • In order to investigate chemical components and mineral of ginseng cultivated in Korea and to establish an appropriate extraction method, the present work was carried out with Raw ginseng(SC), White ginseng(SB) and Ginseng tail(SA). The results determined could be summarized as follows : 1. Among the proximate components, moisture content of SC, SB and SA were 66.37%, 12.61% and 12.20% respectively. The content of crude ash in SA was the highest value of three kinds of ginseng root: SA 6.04%, SB 3.52% and SC 1.56%. The crude protein of Dried ginseng root(SA and SB) was about 12-14%, which was more than two times compared with that of SC(6.30%) The content of pure protein seemed to be in similar tendency with that of crude protein in three kinds of ginseng root: 2.26% in SC, 5.94% in SB and 5.76% in SA. There was no significant difference in the content of fat among the kinds of ginseng root. $(1.1{\sim}2.5%)$ 2. The highest Ginseng extract was obtained by use of Continuous extractor which is a modified Soxhlet apparatus for 60 hours extraction with 60-80% ethanol. 3. Ginseng and the above-mentioned ginseng extract (Ginseng tail extract: SAE, White Ginseng extract : SBE, Raw Ginseng extract: SCE) were analyzed by volumetric method for the determination of Chlorine and Calcium, by colorimetric method for that of Iron and Phosphorus, by Atomic Absorption Spectrophotometer for that of Zinc, Copper and Manganese. The results were as follows : 1. The content of phosphorus in SA, SB and SC were 1.818%, 1.362%, 0.713% respectively and phosphorus content in three kinds of extract were in low level (SAE: 0.03%, SBE: 0.063%, SCE: 0.036%) 2. In the Calcium content, SA, SB and SC were 0.147%, 0.238%, 0.126% and the Calcium contents of Ginseng extracts were 0.023%, 0.011% and 0.016%. The extraction ratio of Calcium from SA was the highest value (15.6%), while that in the case of SB was 4.6%. 3. The Chlorine content of SA was 0.11%, this was slightly higher than others(SB: 0.07%, SC: 0.09%) and extraction ratio of SA and SB were 36.4%, 67.1% while that of SC was 84.4%. 4. The Iron content of SA, SB and SC were 125ppm, 32.5ppm and 20ppm but extraction ratio was extremely low (SAE: 1.33%, SBE: 0.83%, SCE: 1.08%), 5. The Manganese content of SA, SB and SC were 62.5ppm, 25.0ppm and 5.0ppm respectively but the Manganese content of extract could not determined, Copper content of SA, SB and SC were 15.0ppm, 20.0ppm and those of extract were 7.5ppm, 6.5ppm, 4.5ppm while those of extraction ratio were 50%, 32.5% and 90% respectively, Zinc was abundant in Ginseng compared with other herbs, (SA: 45.5ppm, SB: 27.5ppm and SC: 5.5ppm) and the extracted amount were 4.5ppm, 1.25ppm 1.50ppm respectively.

  • PDF

Comparison of Results According to Reaction Conditions of Thyroglobulin Test (Thyroglobulin 검사의 반응조건에 따른 결과 비교 분석)

  • Joung, Seung-Hee;Lee, Young-Ji;Moon, Hyung-Ho;Yoo, So-yoen;Kim, Nyun-Ok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.39-43
    • /
    • 2017
  • Purpose Thyroglobulin (Tg) is a biologic marker of differentiated thyroid carcinoma (DTC), produced by normal thyroid tissue or thyroid cancer tissue. Therefore, the Tg values of DTC patients is the most specific indicator for judging whether recurrence occur or whether the remaining thyroid cancer is present. Thyroid cancer is currently the most common cancer in Korea, of which 90% is differentiated thyroid cancer. The number of patients with thyroid disease of this application also increased, and an accurate and prompt results are required. However, the incubation time of the Tg commonly takes about 24 hours in our hospital, and the result reporting time is delayed, and We could not satisfied with the requirements of clinical departments and patients. In order to fulfill these requirements, experiments were conducted by shortening the incubation time between company B's Kit currently in use and company C's Kit used in other hospitals. Through these experiments, we could perform the correlation with the original method and shortening method, and could find the optimum reaction time to satisfy the needs of the departments and the patients, and we will improve the competitiveness with the EIA examination. Materials and Methods In September 2016, we tested 65 patients company B's kit and company C's kit by three incubation ways. First method $37^{\circ}C$ shaking 2hr/2hr, Second method RT shaking 3hr/2hr, Third method 1hr/1hr shaking at $37^{\circ}C$. Fourth method RT shaking 3hr method which is the original method of Company C's Kit. Fifth method, the incubation time was shortened under room temperature shaking 2hr, Sixth method $37^{\circ}C$ shaking 2hr. And we performed and compared the correlation and coefficient of each methods. Results As a result of performing shortening method on company B currently in use, when comparing the Original method of company B kit, First method $37^{\circ}C$ shaking 2hr/2hr was less than Tg 1.0 ng/mL and the ratio of $R^2=0.5906$, above 1.0 ng/mL In the value, $R^2=0.9597$. Second method RT shaking 3hr/2hr was $R^2=0.7262$ less than value of 1.0 ng/mL, $R^2=0.9566$ above than value of 1.0 ng/mL. Third method $37^{\circ}C$ shaking 1hr/1hr was $R^2=0.7728$ less than value of 1.0 ng/mL, $R^2=0.8904$ above than value of 1.0 ng/mL. Forth, Company C's The original method, RT shaking 3hr was $R^2=0.7542$ less than value of 1.0 ng/mL, and $R^2=0.9711$ above than value of 1.0 ng/mL. Fifth method RT shaking 2hr was $R^2=0.5477$ less than value of 1.0 ng/mL, $R^2=0.9231$ above than value of 1.0 ng/mL. Sixth method $37^{\circ}C$ shaking 2hr showed $R^2=0.2848$ less than value of 1.0 ng/mL, $R^2=0.9028$ above than value of 1.0 ng/mL. Conclusion Samples with both values of 1.0 ng/mL or higher in both of the six methods showed relatively high correlation, but the correlation was relatively low less than value of 1.0 ng/mL. Especially, the $37^{\circ}C$ shaking 2hr method of company C showed a sharp fluctuation from the low concentration value of 1.0 ng/mL or less. Therefore, we are planning to continuously test the time, equipment, incubation temperature and so on for the room temperature shaking 2hr method and $37^{\circ}C$ shaking 1hr/1hr of company C which showed a relatively high correlation. After that, we can search for an appropriate shortening method through additional experiments such as recovery test, dilution test, sensitivity test, and provide more accurate and prompt results to the department of medical treatment, It is competitive with EIA test.

  • PDF

Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan (99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교)

  • Kim, Hyeon;Do, Yong-Ho;Kim, Jae-Il;Choi, Hyeon-Jun;Woo, Jae-Ryong;Bak, Chan-Rok;Ha, Tae-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose Glomerular Filtration Rate(GFR) is an important indicator for evaluating renal function and monitoring the progress of renal disease. Currently, the method of measuring GFR in clinical trials by using serum creatinine value and 99mTc-DTPA(diethylenetriamine pentaacetic acid) renal dynamic scan is still useful. After the Gates method of formula was announced, when 99mTc-DTPA Renal dynamic scan is taken, it is applied the GFR is measured using a gamma camera. The purpose of this paper is to measure the GFR by applying the Gates method of formula. It is according to effect activity and matrix size that is related in the GFR. Materials and Methods Data from 5 adult patients (patient age = 62 ± 5, 3 males, 2 females) who had been examined 99mTc-DTPA Renal dynamic scan were analyzed. A dynamic image was obtained for 21 minutes after instantaneous injection of 99mTc-DTPA 15 mCi into the patient's vein. To evaluate the glomerular filtration rate according to changes in activity and matrix size, total counts were measured after setting regions of interest in both kidneys and tissues in 2-3 minutes. The distance from detector to the table was maintained at 30cm, and the capacity of the pre-syringe (PR) was set to 15, 20, 25, 30 mCi, and each the capacity of post-syringe (PO) was 1, 5, 10, 15 mCi is set to evaluate the activity change. And then, each matrix size was changed to 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, and 1024 × 1024 to compare and to evaluate the values. Results As the activity increased in matrix size, the difference in GFR gradually decreased from 52.95% at the maximum to 16.67% at the minimum. The GFR value according to the change of matrix size was similar to 2.4%, 0.2%, 0.2% of difference when changing from 128 to 256, 256 to 512, and 512 to 1024, but 54.3% of difference when changing from 32 to 64 and 39.43% of difference when changing from 64 to 128. Finally, based on the presently used protocol, 256 × 256, PR 15 mCi and PO 1 mCi, the GFR value was the largest difference with 82% in PR 15 mCi and PO 1 mCi. conditions, and at the least difference is 0.2% in the conditions of PR 30 mCi and PO 15 mCi. Conclusion Through this paper, it was confirmed that when measuring the GFR using the gate method in the 99mTc-DTPA renal dynamic scan. The GFR was affected by activity and matrix size changes. Therefore, it is considered that when taking the 99mTc-DTPA renal dynamic scan, is should be careful by applying appropriate parameters when calculating GFR in the every hospital.

A study on the improvement of distribution system by overseas agricultural investment (해외농업투자에 따른 유통체계 개선방안에 관한 연구)

  • Sun, Il-Suck;Lee, Dong-Ok
    • Journal of Distribution Science
    • /
    • v.8 no.3
    • /
    • pp.17-26
    • /
    • 2010
  • Recently concerns have been raised due to the unbalanced supply of crops: the price of crops has been unstable and at one point the price went up so high that the word Agflation(agriculture+ inflation) was coined. Korea, in particular, is a small-sized country and needs to secure the stable supply of crops by investing in the produce importation at a national level. Investment in foreign produce importation is becoming more important as a measure for sufficient supply of crops, limited supply of domestic crops, weakened farming conditions worldwide, as well as recent changes in the use of crops due to the development of bio-fuels, influence of carbon emission on crops, the price increase in crops, and influx of foreign hot money. However, there are many problems with investing in foreign produce importation: lack of support from the government; lack of farming information and technology; difficulty in securing the capital; no immediate pay-off from the investment and insufficient management. Although foreign produce is originally more price-competitive than domestic produce, it loses its competiveness in the process of importation (due to high tariffs) and poor distribution system, which makes it difficult to sell in Korea. Therefore, investment in foreign produce importation is being questioned for feasibility; to make it possible, foreign produce must maintain the price-competitiveness. Especially, harvest of agricultural products depends on natural and geographical conditions of each country and those products have indigenous properties, so distribution system according to import and export of agricultural products should be treated more carefully than that of other industries. Distribution costs are differentiated into each item and include cost of sorting and wrapping, cost of wrapping materials, cost of domestic transport, cost of international transport and cost of clearing customs for import and export. So transporting and storing agricultural products generates considerable costs compared with other products. Also, due to upgrade of dietary life, needs for stability, taste and visible quality toward food including agricultural products are being raised and wrong way of storage causes decomposition of food and loss of freshness, making the storage more difficult than that in room temperature, so storage and transport in distribution of agricultural products needs specialty. In addition, because lack of specialty in distribution and circulation such as storage and wrapping does not solve limit factors in distance, the distribution and circulation has been limited to a form of import and export within short-distant region. Therefore, need for distribution out-sourcing which can satisfy specialty in managing distribution and circulation and it is needed to establish more effective distribution system. However, existing distribution system of agricultural products is exposed to various problems including problems in distribution channel, making distribution and strategy for distribution and those problems are as follows. First, in case of investment in overseas agricultural industry, stable supply of the products is difficult because areas of production are dispersed widely and influenced by outer factors due to including overseas distribution channels. Also, at the aspect of quality, standardization of products is difficult, distribution system is quite complicated and unreasonable due to long distribution channels according to international trade and financial and institutional support is not enough. Especially, there are quite a lot of ineffective factors including multi level distribution process, dramatic gap between production cost and customer's cost, lack of physical distribution facilities and difficulties in storage and transport due to lack of wrapping containers. Besides, because import and export of agricultural products has been manages under the company's own distribution according to transaction contract between manufacturers and exporting company, efficiency is low due to excessive investment in fixed costs and lack of specialty in dealing with agricultural products causes fall of value of products, showing the limit to lose price-competitiveness. Especially, because lack of specialty in distribution and circulation such as storage and wrapping does not solve limit factors in distance, the distribution and circulation has been limited to a form of import and export within short-distant region. Therefore, need for distribution out-sourcing which can satisfy specialty in managing distribution and circulation and it is needed to establish more effective distribution system. Second, among tangible and intangible services which promote the efficiency of the whole distribution, a function building distribution environment which includes distribution information, system for standard and inspection, distribution finance, system for diversification of risks, education and training, distribution administration and tax system is wanted. In general, such a function building distribution environment is difficult to be changed and supplement innovatively because its effect compared with investment does not appear immediately despite of its necessity. Especially, in case of distribution of agricultural products, as a function of collecting and distributing is performed individually through various channels, the importance of distribution information and standardization is getting more focus due to the problem of repetition of work and lack of specialty. Also, efficient management of distribution is quite difficult due to lack of professionals in distribution, so support to professional education is needed. Third, though effort to keep self-sufficiency ratio of staple food, rice is regarded as important at the government level, level of dependency on overseas of others crops is high. Therefore, plan for stable securing food resources aside from staple food is also necessary. Especially, governmental organizations of agricultural products distribution in Korea are production-centered and have unreasonable structure whose function at the aspect of distribution and consumption is quite insufficient. And development of new distribution channels which can deal with changes in distribution environment and they do not achieve actual results of strategy for distribution due to non-positive strategy for price distribution. That is, it implies the possibility that base for supply will become vulnerable because it does not mediate appropriate interests on total distribution channels such as manufacturers, wholesale dealers and vendors by emphasizing consumer protection excessively in the distribution of agricultural products. Therefore, this study examined fundamental concept and actual situation for our investment to overseas agriculture, drew necessities, considerations, problems, etc. of overseas agricultural investment and suggested improvements at the level of distribution for price competitiveness of agricultural products cultivated in overseas under five aspects; government's indirect support, distribution's modernization and distribution information function's strengthening, government's political support for distribution facility, transportation route, load and unloading works' improvement, price competitiveness' securing, professional manpower's cultivation by education and training, etc. Here are some suggestions for foreign produce importation. First, the government should conduct a survey on the current distribution channels and analyze the situation to establish a measure for long-term development plans. By providing each agricultural area with a guideline for planning appropriate production of crops, the government can help farmers be ready for importation, and prevent them from producing same crops all at the same time. Government can sign an MOU with the foreign government and promote the importation so that the development of agricultural resources can be stable and steady. Second, the government can establish a strategy for an effective distribution system by providing farmers and agriculture-related workers with the distribution information such as price, production, demand, market structure and location, feature of each crop, and etc. In order for such distribution system to become feasible, the government needs to reconstruct the current distribution system, designate a public organization for providing distribution information and set the criteria for level of produce quality, trade units, and package units. Third, the government should provide financial support and a policy to seek an efficient distribution channel for foreign produce to be delivered fresh: the government should expand distribution facilities (for selecting, packaging, storing, and processing) and transportation vehicles while modernizing old facilities. There should be another policy to improve the efficiency of unloading, and to lower the cost of distribution. Fourth, it is necessary to enact a new law covering exceptional cases for importing produce in order to maintain the price competitiveness; currently the high tariffs is keeping the imported produce from being distributed domestically. However, the new adjustment should be made carefully within the WTO regulations since it can create a problem from giving preferential tariffs. The government can also simplify the distribution channels in order to reduce the cost in the distribution process. Fifth, the government should educate distributors to raise the efficiency and to modernize the distribution system. It is necessary to develop human resources by educating people regarding the foreign agricultural environment, the produce quality, management skills, and by introducing some successful cases in advanced countries.

  • PDF

A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry (골밀도검사의 올바른 질 관리에 따른 임상적용과 해석 -이중 에너지 방사선 흡수법을 중심으로-)

  • Dong, Kyung-Rae;Kim, Ho-Sung;Jung, Woon-Kwan
    • Journal of radiological science and technology
    • /
    • v.31 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose : Because there is a difference depending on the environment as for an inspection equipment the important part of bone density scan and the precision/accuracy of a tester, the management of quality must be made systematically. The equipment failure caused by overload effect due to the aged equipment and the increase of a patient was made frequently. Thus, the replacement of equipment and additional purchases of new bonedensity equipment caused a compatibility problem in tracking patients. This study wants to know whether the clinical changes of patient's bonedensity can be accurately and precisely reflected when used it compatiblly like the existing equipment after equipment replacement and expansion. Materials and methods : Two equipments of GE Lunar Prodigy Advance(P1 and P2) and the Phantom HOLOGIC Spine Road(HSP) were used to measure equipment precision. Each device scans 20 times so that precision data was acquired from the phantom(Group 1). The precision of a tester was measured by shooting twice the same patient, every 15 members from each of the target equipment in 120 women(average age 48.78, 20-60 years old)(Group 2). In addition, the measurement of the precision of a tester and the cross-calibration data were made by scanning 20 times in each of the equipment using HSP, based on the data obtained from the management of quality using phantom(ASP) every morning (Group 3). The same patient was shot only once in one equipment alternately to make the measurement of the precision of a tester and the cross-calibration data in 120 women(average age 48.78, 20-60 years old)(Group 4). Results : It is steady equipment according to daily Q.C Data with $0.996\;g/cm^2$, change value(%CV) 0.08. The mean${\pm}$SD and a %CV price are ALP in Group 1(P1 : $1.064{\pm}0.002\;g/cm^2$, $%CV=0.190\;g/cm^2$, P2 : $1.061{\pm}0.003\;g/cm^2$, %CV=0.192). The mean${\pm}$SD and a %CV price are P1 : $1.187{\pm}0.002\;g/cm^2$, $%CV=0.164\;g/cm^2$, P2 : $1.198{\pm}0.002\;g/cm^2$, %CV=0.163 in Group 2. The average error${\pm}$2SD and %CV are P1 - (spine: $0.001{\pm}0.03\;g/cm^2$, %CV=0.94, Femur: $0.001{\pm}0.019\;g/cm^2$, %CV=0.96), P2 - (spine: $0.002{\pm}0.018\;g/cm^2$, %CV=0.55, Femur: $0.001{\pm}0.013\;g/cm^2$, %CV=0.48) in Group 3. The average error${\pm}2SD$, %CV, and r value was spine : $0.006{\pm}0.024\;g/cm^2$, %CV=0.86, r=0.995, Femur: $0{\pm}0.014\;g/cm^2$, %CV=0.54, r=0.998 in Group 4. Conclusion: Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ${\pm}2%$ defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  • PDF