• 제목/요약/키워드: Applied pressure

검색결과 6,753건 처리시간 0.037초

맥진 깊이 판단을 위한 실시간 압력 측정기 (Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse)

  • 조정호;김대복;김기왕
    • 동의생리병리학회지
    • /
    • 제27권3호
    • /
    • pp.313-317
    • /
    • 2013
  • In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin($10{\mu}m$) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.

경화 압력이 접착 조인트의 비틀림 피로 특성에 미치는 영향 (Effects of the curing pressure on the torsional fatigue characteristics of adhesively bonded joints)

  • 황희윤;김병중;이대길
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.196-201
    • /
    • 2004
  • Adhesive joints have been widely used for fastening thin adherends because they can distribute the load over a larger area than mechanical joints, require no hole, add very little weight to the structure and have superior fatigue resistance. However, the fatigue characteristics of adhesive joints are much affected by applied pressure during curing operation because actual curing temperature is changed by applied pressure and the adhesion characteristics of adhesives are very sensitive to manufacturing conditions. In this study, cure monitoring and torsional fatigue tests of adhesive joints with an epoxy adhesive were performed in order to investigate the effects of the applied pressure during curing operation. From the experiments, it was found that the actual curing temperature increased as the applied pressure increased, which increased residual thermal stress in the adhesive layer. Therefore, the fatigue life decreased as the applied pressure increased because the mean stress during fatigue tests increased due to the residual thermal stress.

  • PDF

합곡(合谷 LI-4)지압이 초산부의 분만 통증정도와 소요 시간에 미치는 효과 (Effects On Labor Pain and Duration of Delivery Time for Primipara Women treated by Hob-Gog(Li-4) Pressure)

  • 김영란;이선혜;강진선;정금옥;주영아
    • 여성건강간호학회지
    • /
    • 제7권3호
    • /
    • pp.331-347
    • /
    • 2001
  • The purpose of this study was to compare the effects on labor pain and duration of delivery time for primipara women treated by Hob-Gog (LI-4) pressure. 1. The proposed hypothesis was that 'the score of labor pain could be lower in the group which had LI-4 pressure applied than in the control group'. 1-1. The sub hypothesis was that the score of subjective labor pain would be lower in the group which had LI-4 pressure applied than in the group which did not have LI-4 pressure applied. 1-2. Another sub hypothesis was that the score of objective labor pain would be lower in the group which had LI-4 pressure applied than in the group which did not have LI-4 pressure applied. 2. The proposed hypothesis was that 'the score of duration of delivery time could be shorter in the group which had LI-4 pressure applied than in the control group'. The design of this study was a nonequivalent control group non-synchronized post test only design to verify the effect on labor pain for primipara women treated by LI-4 pressure and to evaluate the benefits of using LI-4 pressure on some women and judging the degree of their labor pains in comparison with other primipara women not treated with LI-4 pressure. The subjects included 63 primipara women who underwent vaginal delivery, who were between 38-41 weeks intra uterine pregnancy; who did not have any complications; and who were under pitocin augmentation or induction. They were recruited with informed consent; 34 were in the control group and 29 were in the experimental group. The study was measured with a structured questionnaire consisting of general characteristics, knowledge related to delivery, subjective (Johnson, 1974) and objective(McLachlan, 1974) labor pain scale, data collection was done by research during the period from April, 2000 to July, 2000 and data was analyzed by descriptive statistics, $x^2$-test, and t-test. The results were as follows: 1. The scores of total labor pain in the group which had LI-4 pressure applied were lower($347.62{\pm}49.84$) than in the group($411.02{\pm}55.79$) which did not have LI-4 pressure applied; And these differences were statistically significant(t=4.7193, p=.000). 1-1. The scores of subjective labor pain in the group which had LI-4 pressure applied were lower($203.44${\pm}33.88$)$ than in the group ($$233.82{\pm}31.31$$) which did not have LI-4 pressure applied(t=3.6953, p=.000). 1-2. The scores of objective pain in the group which had LI-4 pressure applied were lower ($144.18{\pm}29.12$) than in the group which did not have LI-4 pressure applied($177.20{\pm}35.01$). but there were no statistically significant differences found in regard to the scores of objective pain(t=4.0271, p=.000). 3. The duration of delivery time in the group which had LI-4 pressure applied was shorter ($390.51min{\pm}111.91$) than in the group ($460.44min{\pm}190.78$)which did not have LI-4 pressure applied and the duration of delivery time in the experimental group was statistically more significant than that in the control group. therefore this thesis was adapted(t=1.734, p=.0879). It could be concluded that LI-4 pressure is effective in relation to labor pain and duration of delivery time for primipara women. Therefore it is necessary to increase the number of subjects to generalize this result.

  • PDF

An Experimental Study of Water Vapor Pressure Change by Ambient Temperature at the Interface between Concrete and Fluid-Applied Membrane Layer

  • Ko, Jin-Soo;Kim, Byung-Yun;Park, Sung-Woo;Lee, Mun-Hwan;Lee, Sung-Bok
    • International Journal of Concrete Structures and Materials
    • /
    • 제3권1호
    • /
    • pp.15-23
    • /
    • 2009
  • Over about 30% of problems in construction is related to water-leaking, and the loss from this problem can incur as much as three times the cost of initial construction. Thus, water vapor pressure is known to be the primary cause of defective waterproofing. Accordingly, the theories on the relationship between water pressure and temperature as well as damp-proofing volume of concrete and the change in vapor pressure volume were reviewed and analyzed in this study by making test samples after spraying a dampness remover and applying waterproofing materials to the prepared test specimens. The result of measuring water vapor pressure with the surface temperature of the waterproofing (fluid-applied membrane) layer at the experimental temperature setting of about $10^{\circ}C$, which is the annual average temperature of Seoul, indicated that (1) the temperature of the fluid-applied membrane elevated to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about 0.03 N/mm 2 when the surface temperature of the waterproofing layer was raised to about $80^{\circ}C$. (2) when the temperature of the fluid-applied membrane of the waterproofing layer was raised from $30^{\circ}C$ to $35^{\circ}C$, water vapor pressure of about 0.01 N/mm 2 was generated, and (3) when a thermal source was applied to the fluid-applied membrane (waterproofing) layer, the temperature increased from $35^{\circ}C$ to $40^{\circ}C$, and approximately $0.005\;N/mm^2$ of water vapor pressure was generated.

Evaluation of spatial pressure distribution during ice-structure interaction using pressure indicating film

  • Kim, Hyunwook;Ulan-Kvitberg, Christopher;Daley, Claude
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제6권3호
    • /
    • pp.578-597
    • /
    • 2014
  • Understanding of 'spatial' pressure distribution is required to determine design loads on local structures, such as plating and framing. However, obtaining a practical 'spatial' pressure distribution is a hard task due to the sensitivity of the data acquisition frequency and resolution. High-resolution Pessure-Idicating Flm (PIF) was applied to obtain pressure distribution and pressure magnitude using stepped crushing method. Different types of PIF were stacked at each test to creating a pressure distribution plot at specific time steps. Two different concepts of plotting 'spatial' pressure-area curve was introduced and evaluated. Diverse unit pixel size was chosen to investigate the effect of the resolution in data analysis. Activated area was not significantly affected by unit pixel size; however, total force was highly sensitive.

Squeeze Casting에 의한 SiC 입자강화 Al합금기 복합재료의 미세조직 특성 (Microstructural Characteristics of SiC Particle Reinforced Aluminum Alloy Composite by Squeeze Casting)

  • 김석원;우기도;한상원
    • 한국주조공학회지
    • /
    • 제15권6호
    • /
    • pp.566-573
    • /
    • 1995
  • In this study, the microstructural characteristics such as primary silicon, eutectic silicon, $SiC_p$ dispersion behavior, compound amount and Si solubility in $Al/SiC_p$ composite fabricated by the squeeze casting under various conditions were investigated systematically. As applied pressure(MPa) increases, cooling rate and compound amount are increased. In gravity casting, the cooling rate of hypereutectic composite is slower than of hypoeutectic composite by exothermic reaction of primary Si crystallization. But the cooling rate of hypereutectic composite is faster than that of hypoeutectic composite fabricated by same applied pressure, because amount of primary Si crystallization in hypereutectic composite was decreased, on the contrary, primary ${\alpha}-Al$ in hypoeutetic composite was increased due to increase of Si solubility in matrix by applied pressure. The crystalized primary silicon in hypereutectic composite fabricated by squeeze casting become more fine than that in non-pressure casting This is because mush zone became narrow due to increase of Si content of eutectic composition by pressure and time for growth of primary silicon got shorter according to applied pressure. It is turned out that eutectic temperature and liquidus are decreased by the increasing of squeeze pressure in all the composite due to thermal unstability of matrix owing to increasing of Si solubility in matrix by the increasing of applied pressure, as indicated in thermal anaiysis(DSC) results.

  • PDF

Electrodermal Activity at Palms according to Pressure Stimuli applied to the Scapula

  • Kim, Jae-Hyung;Park, Gun-Cheol;Baik, Sung-Wan;Jeon, Gye-Rok
    • 한국멀티미디어학회논문지
    • /
    • 제19권7호
    • /
    • pp.1137-1145
    • /
    • 2016
  • The system for measuring the electrodermal activity (EDA) signal occurring at the sweet glands in the human body was implemented in this study. The EDA measurement system (EDAMS) consisted of an algometer and the bio-potential measurement system (BPMS). Three experiments were performed using EDAMS. First, the linearity of the output voltage corresponding to the pressure being applied to an algometer was evaluated. The linearity of output voltage according to the pressure was 0.956. Second, the amplitude and the latency of the EDA signal at the left palm was obtained while applying the pressure stimuli to the left and right scapula. The latency of EDA signal was shorter whereas the amplitude of EDA signal was higher when the pressure applied was applied to the left scapula. Third, the amplitude and latency of the EDA was measured at left and right palm while increasing the pressure stimuli to the left scapula. The latency of EDA signal at left and right palm was decreased according to the intensity of pressure stimulus applied to the left scapula. However, the latency of the EDA signals did not show the linearity with respect to the pressure stimuli.

고분자 유동의 3차원 해석을 위한 새로운 검사 체적 유한 요소법 (A New Control Volume Finite Element Method for Three Dimensional Analysis of Polymer Flow)

  • 이석원;윤재륜
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 춘계학술대회논문집
    • /
    • pp.461-464
    • /
    • 2003
  • A new control volume finite element method is proposed for three dimensional analysis of polymer flow. Tetrahedral finite element is employed and co-located interpolation procedure for pressure and velocity is implemented. Inclusion of pressure gradient term in the velocity shape functions prevents the checkerboard pressure field from being developed. Vectorial nature of pressure gradient is considered in the velocity shape function so that velocity profile in the limit of very small Reynolds number becomes physically meaningful. The proposed method was verified through three dimensional simulation of pipe flow problem for Newtonian and power-law fluid. Calculated pressure and velocity field showed an excellent agreement with analytic solutions for pressure and velocity. Driven-cavity problem, which is reported to yield checkerboard pressure filed when conventional finite element method is applied, could be solved without yielding checkerboard pressure field when the proposed control volume finite element method was applied. The proposed method could be successfully applied to the three dimensional mold filling problem.

  • PDF

압력 조건이 초소성 성형품의 성질에 미치는 영향 (The Effect of Pressure-time Condition Affect in Properties of Superplastic Formed part)

  • 이영선;이정환
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.185-194
    • /
    • 1999
  • The shape and thickness distribution according to the pressure-time curve were carried out using the FEM and experiment. Also, mechanical properties were investigated. The square cup parts have been formed with pressure-time curve generated by result of analysis. The tensile strength and elongation have been investigated according to applied pressure conditions using the tensile test specimen obtained from the superplastic formed cup. We can use to predict the shape of formed part under the applied pressure using the FEM analysis. In the case of optimum pressure condition, the thickness distribution and mechanical properties were improved. From this study, we can find the important of optimum pressure-time condition. We have investigated about the forming of airplane part and fuel tank for motorcycle. If the applied load used in boundary conditions was appropriate, the simulation result coincides with the formed part. However, it is very difficult to define the pressure condition in complicated shape. Thus, it is need to develop the optimum pressure condition for superplastic forming.

  • PDF

콘크리트와 도막 방수층 계면에 발생되는 수증기압에 관한 실험적 연구 (An Experimental Study of Water Vapor Pressure that occurs at the Interface of a Fluid-Applied Membrane and Concrete)

  • 고진수;김문희;이성복;신윤호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 추계 학술논문 발표대회 논문집
    • /
    • pp.147-150
    • /
    • 2006
  • Of the total defects that have occurred recently in the Korean construction market, over 30% are caused by the construction of defective waterproofing, and the phenomenon of air pockets in the waterproofing layer, which is caused by the concrete vapor pressure, is known to be the primary cause of defective waterproofing. Accordingly, in this study the theory about the relationship between water pressure and temperature as well as the damp-proofing volume of concrete and, then, the change of vapor pressure volume was measured and analyzed by making a test sample after spraying a dampness remover and a waterproofing material to a prepared test body. As a result of measuring the water vapor pressure for the surface temperature of the waterproofing layer with the fluid-applied membrane temperature based on about $10^{\circ}C$, which is the average temperature of Seoul, it was found that first, the fluid-applied membrane elevated up to about $40^{\circ}C$, and the water vapor pressure generated from the fluid-applied membrane was about $0.3kgf/cm^2$ when the surface temperature of the waterproofing layer was raised up to about $80^{\circ}C$. Second, when the fluid-applied membrane temperature of the waterproofing layer was raised from $30^{\circ}C\;to\;35^{\circ}C,\;about\;0.1kgf/cm^2$ of water vapor pressure was generated, and when supplying a thermal source to raise the fluid-applied membrane temperature of the waterproofing layer from $35^{\circ}C\;to\;40^{\circ}C$, approximately $0.05kgf/cm^2$ of water vapor pressure was generated.

  • PDF