• Title/Summary/Keyword: Application protocol

Search Result 1,497, Processing Time 0.03 seconds

An Efficient Dissemination Protocol for Remote Update in 6LoWPAN Sensor Network (6LoWPAN상에서 원격 업데이트를 위한 효율적인 코드 전파 기법)

  • Kim, Il-Hyu;Cha, Jung-Woo;Kim, Chang-Hoon;Nam, In-Gil;Lee, Chae-Wook
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.2
    • /
    • pp.133-138
    • /
    • 2011
  • In IP-based wireless sensor networks (WSNs), it might be necessary to distribute application updates to the sensor nodes in order to fix bugs or add new functionality. However, physical access to nodes is in many cases extremely limited following deployment. Therefore, network reprogramming protocols have recently emerged as a way to distribute application updates without requiring physical access to sensor nodes. In order to solve the network reprogramming problem over the air interface, this thesis presents a new scheme for new update code propagation using fragmentation scheme and network coding. The proposed code propagation method roughly shows reduced performance improvement in terms of the number of data exchange compared with the previously proposed pipelining scheme. Further, It is shows enhanced reliability for update code propagation and reduced overhead in terms of the number of data exchange. As a result, we can efficiently perform the software update from the viewpoint of speed, energy, and network congestion when the proposed code propagation system is applied. In addition, the proposed system solves overhearing problems of network coding such as the loss of original messages and decoding error using the predefined message. Therefore, our system allows a software update system to exchange reliable data in wireless sensor networks.

Study of N-Port Electric Vehicle Charging Systems Using OPC-UA (OPC UA를 이용한 N-Port EV 충전 시스템 연구)

  • Lee, Seong Joon
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.8
    • /
    • pp.343-352
    • /
    • 2017
  • IEC62541, known as OPC-UA, is a standard communication protocol for Smart Grid (SG) and Smart Factory application platform. It was accepted as an IEC standard (IEC62541) in 2011 by IEC TC57, and is extending range of application as collaborating with other standrads. The government's policies to popularize EVs ("Workplace Charging Challenge"), the number of Electric vehicle which try to be charging in the factory is expected to increase. In this situation, indiscreet and uncontrolled EV charging can lead to some problems, such as excess of the peak demand capacity. Therefore, EVs, which is charging in SFs, must be monitoring and controlling to avoid and reduce peak demand. However, the standards for EVs charging differ from the standards for SFs. In other words, to increase the ease of use for drivers, and reduce risk for enterprise, we have needs of study to develop the protocols or to provide interoperability, for EVs charging in SFs. This paper deals with a EV charging management platform installing in a smart factory. And this platform can be easily integrated as part of SF management software. The main goal of this paper is to implement EV management system based on IEC61851 and IEC62541.

A Study on Linkage Integration Control System Using Power Line Communication(PLC) and Wireless Sensor Network(WSN) (전력선 통신과 무선 센서 네트워크 기술을 이용한 연동 통합제어 시스템에 관한 연구)

  • Ji, Yun-il;Lim, Kang-il;Park, Kyung-sub
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.733-736
    • /
    • 2009
  • Power Line Communication(PLC) is need not additional communication line. So establishment expense is inexpensive and application is simple. Therefore, lower part network of various application field is possible. However, there are high subordinate interference and noise problem on limited transmission data and communication interference element. Wireless Sensor Network(WSN) is need not infrastructure, Self-regulating network architecture of sensor nodes is possible. So at short time, network construction is available. But, power consumption is increased by active sensing for QoS elevation and unnecessary information transmission, low electric power design and necessity of improve protocol are refered to life shortening problem and is studied. In this paper, supplement problem of power line communication and wireless sensor network mutually and because advantage becomes linkage integration control system using synergy effect of two technologies as more restriction be and tries to approach structurally control network that is improved for smooth network environment construction. Honeywell's hybrid sensor network does comparative analysis(benchmarking). Confirm performance elevation proposing teaming of power line communication and wireless sensor network. Through simulation, service delay decreases and confirms that performance elevation.

  • PDF

The research of the Sensor network service platform technology based on OGC (OGC 기반의 센서 네트워크 서비스 플랫폼 기술 연구)

  • Yeom, Sung-Kun;Yoo, Sang-Keun;Kim, Yong-Woon;Kim, Hyoung Jun;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.1022-1025
    • /
    • 2009
  • USN(Ubiquitous Sensor Network) is a core infrastructure that makes come true the u-life in the ubiquitous society through various services of area such as u-city and u-Health. Therefore, we need to reseach about the domestic standards to establish the core technique of USN. Currently, the status of USN standards is most of technical standard and reseach that are technology for sensor node implementation and a protocol for energy-efficient communication and interlock with existing network. But, Standard and reseach for sensor network, integration management of heterogeneous sensor networks for USN application, sensing data management and USN database structure definition such as application and middleware are weak level. In this paper, we researched for standard development of the domestic sensor network service and relevant standard analysis to configure SWE(Sensor Web Enablement) of OGC(Open Geospatial Consortium) for standarded plattform technoloy in part of the middleware. Also we researched that it's a connection between domestic TTA (Telecommunications Technology Association) standards and SWE Standard. Finally, we researched for standard service plattform architecture on sensor network through analysis on the possibility of applying OGC-based services platform.

  • PDF

Reliable Hybrid Multicast using Multi-layer Transmission Path (다계층 전송경로를 이용한 신뢰성 있는 하이브리드 멀티캐스트)

  • Gu, Myeong-Mo;Kim, Bong-Gi
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.35-40
    • /
    • 2019
  • It is important to constantly provide service in real-time multimedia applications using multicast. Transmission path reconstruction occurs in hybrid multicast using Internet Protocol (IP) multicast and ALM in order to adapt the network status to things like congestion. So, there is a problem in which real-time QoS is reduced, caused by an increase in end-to-end delay. In this paper, we want to solve this problem through multi-layer transmission path construction. In the proposed method, we deploy the control server and application layer overlay host (ALOH) in each multicast domain (MD) for hybrid multicast construction. After the control server receives the control information from an ALOH that joins the MD, it makes a group based on the hop count and sends it to the ALOH in each MD. The ALOH in the MD performs the role of sending the packet to another ALOH and constructs the multi-layered transmission path in order of priority by using control information that is received from the control server and based on the delay between neighboring ALOHs. When congestion occurs in, or is absent from, the ALOH in the upper MD, the ALOH selects the path with the highest priority in order to reduce end-to-end delay. Simulation results show that the proposed method could reduce the end-to-end delay to less than 289 ms, on average, under congestion status.

Guidelines for Transrectal Ultrasonography-Guided Prostate Biopsy: Korean Society of Urogenital Radiology Consensus Statement for Patient Preparation, Standard Technique, and Biopsy-Related Pain Management

  • Myoung Seok Lee;Min Hoan Moon;Chan Kyo Kim;Sung Yoon Park;Moon Hyung Choi;Sung Il Jung
    • Korean Journal of Radiology
    • /
    • v.21 no.4
    • /
    • pp.422-430
    • /
    • 2020
  • The Korean Society of Urogenital Radiology (KSUR) aimed to present a consensus statement for patient preparation, standard technique, and pain management in relation to transrectal ultrasound-guided prostate biopsy (TRUS-Bx) to reduce the variability in TRUS-Bx methodologies and suggest a nationwide guideline. The KSUR guideline development subcommittee constructed questionnaires assessing prebiopsy anticoagulation, the cleansing enema, antimicrobial prophylaxis, local anesthesia methods such as periprostatic neurovascular bundle block (PNB) or intrarectal lidocaine gel application (IRLA), opioid usage, and the number of biopsy cores and length and diameter of the biopsy needle. The survey was conducted using an Internet-based platform, and responses were solicited from the 90 members registered on the KSUR mailing list as of 2018. A comprehensive search of relevant literature from Medline database was conducted. The strength of each recommendation was graded on the basis of the level of evidence. Among the 90 registered members, 29 doctors (32.2%) responded to this online survey. Most KSUR members stopped anticoagulants (100%) and antiplatelets (76%) one week before the procedure. All respondents performed a cleansing enema before TRUS-Bx. Approximately 86% of respondents administered prophylactic antibiotics before TRUS-Bx. The most frequently used antibiotics were third-generation cephalosporins. PNB was the most widely used pain control method, followed by a combination of PNB plus IRLA. Opioids were rarely used (6.8%), and they were used only as an adjunctive pain management approach during TRUS-Bx. The KSUR members mainly chose the 12-core biopsy method (89.7%) and 18G 16-mm or 22-mm (96.5%) needles. The KSUR recommends the 12-core biopsy scheme with PNB with or without IRLA as the standard protocol for TRUS-Bx. Anticoagulants and antiplatelet agents should be discontinued at least 5 days prior to the procedure, and antibiotic prophylaxis is highly recommended to prevent infectious complications. Glycerin cleansing enemas and administration of opioid analogues before the procedure could be helpful in some situations. The choice of biopsy needle is dependent on the practitioners' situation and preferences.

The Study about Application of LEAP Collimator at Brain Diamox Perfusion Tomography Applied Flash 3D Reconstruction: One Day Subtraction Method (Flash 3D 재구성을 적용한 뇌 혈류 부하 단층 촬영 시 LEAP 검출기의 적용에 관한 연구: One Day Subtraction Method)

  • Choi, Jong-Sook;Jung, Woo-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.102-109
    • /
    • 2009
  • Purpose: Flash 3D (pixon(R) method; 3D OSEM) was developed as a software program to shorten exam time and improve image quality through reconstruction, it is an image processing method that usefully be applied to nuclear medicine tomography. If perfoming brain diamox perfusion scan by reconstructing subtracted images by Flash 3D with shortened image acquisition time, there was a problem that SNR of subtracted image is lower than basal image. To increase SNR of subtracted image, we use LEAP collimators, and we emphasized on sensitivity of vessel dilatation than resolution of brain vessel. In this study, our purpose is to confirm possibility of application of LEAP collimators at brain diamox perfusion tomography, identify proper reconstruction factors by using Flash 3D. Materials and methods: (1) The evaluation of phantom: We used Hoffman 3D Brain Phantom with $^{99m}Tc$. We obtained images by LEAP and LEHR collimators (diamox image) and after 6 hours (the half life of $^{99m}Tc$: 6 hours), we use obtained second image (basal image) by same method. Also, we acquired SNR and ratio of white matters/gray matters of each basal image and subtracted image. (2) The evaluation of patient's image: We quantitatively analyzed patients who were examined by LEAP collimators then was classified as a normal group and who were examined by LEHR collimators then was classified as a normal group from 2008. 05 to 2009. 01. We evaluate the results from phantom by substituting factors. We used one-day protocol and injected $^{99m}Tc$-ECD 925 MBq at both basal image acquisition and diamox image acquisition. Results: (1) The evaluation of phantom: After measuring counts from each detector, at basal image 41~46 kcount, stress image 79~90 kcount, subtraction image 40~47 kcount were detected. LEAP was about 102~113 kcount at basal image, 188~210 kcount at stress image and 94~103 at subtraction image kcount were detected. The SNR of LEHR subtraction image was decreased than LEHR basal image about 37%, the SNR of LEAP subtraction image was decreased than LEAP basal image about 17%. The ratio of gray matter versus white matter is 2.2:1 at LEHR basal image and 1.9:1 at subtraction, and at LEAP basal image was 2.4:1 and subtraction image was 2:1. (2) The evaluation of patient's image: the counts acquired by LEHR collimators are about 40~60 kcounts at basal image, and 80~100 kcount at stress image. It was proper to set FWHM as 7 mm at basal and stress image and 11mm at subtraction image. LEAP was about 80~100 kcount at basal image and 180~200 kcount at stress image. LEAP images could reduce blurring by setting FWHM as 5 mm at basal and stress images and 7 mm at subtraction image. At basal and stress image, LEHR image was superior than LEAP image. But in case of subtraction image like a phantom experiment, it showed rough image because SNR of LEHR image was decreased. On the other hand, in case of subtraction LEAP image was better than LEHR image in SNR and sensitivity. In all LEHR and LEAP collimator images, proper subset and iteration frequency was 8 times. Conclusions: We could archive more clear and high SNR subtraction image by using proper filter with LEAP collimator. In case of applying one day protocol and reconstructing by Flash 3D, we could consider application of LEAP collimator to acquire better subtraction image.

  • PDF

Fast Join Mechanism that considers the switching of the tree in Overlay Multicast (오버레이 멀티캐스팅에서 트리의 스위칭을 고려한 빠른 멤버 가입 방안에 관한 연구)

  • Cho, Sung-Yean;Rho, Kyung-Taeg;Park, Myong-Soon
    • The KIPS Transactions:PartC
    • /
    • v.10C no.5
    • /
    • pp.625-634
    • /
    • 2003
  • More than a decade after its initial proposal, deployment of IP Multicast has been limited due to the problem of traffic control in multicast routing, multicast address allocation in global internet, reliable multicast transport techniques etc. Lately, according to increase of multicast application service such as internet broadcast, real time security information service etc., overlay multicast is developed as a new internet multicast technology. In this paper, we describe an overlay multicast protocol and propose fast join mechanism that considers switching of the tree. To find a potential parent, an existing search algorithm descends the tree from the root by one level at a time, and it causes long joining latency. Also, it is try to select the nearest node as a potential parent. However, it can't select the nearest node by the degree limit of the node. As a result, the generated tree has low efficiency. To reduce long joining latency and improve the efficiency of the tree, we propose searching two levels of the tree at a time. This method forwards joining request message to own children node. So, at ordinary times, there is no overhead to keep the tree. But the joining request came, the increasing number of searching messages will reduce a long joining latency. Also searching more nodes will be helpful to construct more efficient trees. In order to evaluate the performance of our fast join mechanism, we measure the metrics such as the search latency and the number of searched node and the number of switching by the number of members and degree limit. The simulation results show that the performance of our mechanism is superior to that of the existing mechanism.

Usefulness of Xact-bone for the Resolution Advancement of Gamma Camera Image (감마카메라 영상에서 분해능 향상을 위한 Xact-bone의 유용성 평가)

  • Kim, Jong-Pil;Yoon, Seok-Hwan;Lim, Jung-Jin;Woo, Jae-Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.30-35
    • /
    • 2011
  • Purpose: The Boramae Hospital are currently using Wide beam reconstruction (WBR: UltraSPECT, Israel) to improve the resolution. The Xact-bone belongs to the WBR. It has been reported that Xact-bone helps us to improve image resolution and contrast. This study will be evaluated clinical usefulness of Xact-bone method. Materials and Methods: The usefulness evaluation of Xact-bone method was analyzed in resolution test and contrast ratio. The resolution test in Planar image were obtained from Full width at half maximum (FWHM) by using capillary tube. And the contrast ratio was obtained from Bone and Soft tissue (B/S) ratio values that were acquired from bone scan study of 50 patients before and after using the Xact-bone method. We prepared the Triple Line Source Phantom, NEMA IEC Body Phantom and Standard Jaszczak Phantom to acquire the FWHM and Contrast Ratio values of Single photon emission computed tomography (SPECT) image. Subsequently we compared among the Filtered backprojection (FBP), Orderd subset expectation maximization (OSEM) and Xact-Bone image. Results: The results of the planar Xact-bone data improved resolution about 20% by using capillary tube. In addition it was improved B/S ratio about 15%. When using Triple Line Source Phantom, SPECT Xact-bone data improved resolution for both FBP, OSEM methods about 20% and 10%, respectively. Contrast ratio in each spheres has also been increased for both methods that using NEMA IEC body Phantom and Standard Jaszczak Phantom. Conclusion: When we were using Xact-bone method, we could see to improve the resolution and Contrast ratio as compared to do not use the Xact-bone method. Accordingly, by using WBR's Xact-bone method is expected to improve the image quality. However, when introducing new software, it is needed to match the characteristics of the hospital protocol and clinical application.

  • PDF

Dose Evaluation of TPS according to Treatment Sites in IMRT (세기조절방사선치료 시 치료 부위에 따른 치료계획 시스템 간 선량평가)

  • Kim, Jin Man;Kim, Jong Sik;Hong, Chae Seon;Park, Ju Young;Park, Su Yeon;Ju, Sang Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.181-186
    • /
    • 2013
  • Purpose: This study executed therapy plans on prostate cancer (homogeneous density area) and lung cancer (non-homogeneous density area) using radiation treatment planning systems such as $Pinnacle^3$ (version 9.2, Philips Medical Systems, USA) and Eclipse (version 10.0, Varian Medical Systems, USA) in order to quantify the difference between dose calculation according to density in IMRT. Materials and Methods: The subjects were prostate cancer patients (n=5) and lung cancer patients (n=5) who had therapies in our hospital. Identical constraints and optimization process according to the Protocol were administered on the subjects. For the therapy plan of prostate cancer patients, 10 MV and 7Beam were used and 2.5 Gy was prescribed in 28 fx to make 70 Gy in total. For lung cancer patients, 6 MV and 6Beam were used and 2 Gy was prescribed in 33 fx to make 66 Gy in total. Through two therapy planning systems, maximum dose, average dose, and minimum dose of OAR (Organ at Risk) of CTV, PTV and around tumor were investigated. Results: In prostate cancer, both therapy planning systems showed within 2% change of dose of CTV and PTV and normal organs (Bladder, Both femur and Rectum out) near the tumor satisfied the dose constraints. In lung cancer, CTV and PTV showed less than 2% changes in dose and normal organs (Esophagus, Spinal cord and Both lungs) satisfied dose restrictions. However, the minimum dose of Eclipse therapy plan was 1.9% higher in CTV and 3.5% higher in PTV, and in case of both lungs there was 3.0% difference at V5 Gy. Conclusion: Each TPS according to the density satisfied dose limits of our hospital proving the clinical accuracy. It is considered more accurate and precise therapy plan can be made if studies on treatment planning for diverse parts and the application of such TPS are made.

  • PDF