• 제목/요약/키워드: Application

검색결과 82,001건 처리시간 0.082초

소아 치아우식관리 애플리케이션에 대한 사용자 평가 (User evaluation of the mobile application, CAMBRA-kids, for caries management in preschoolers)

  • 강유민;이수영
    • 한국치위생학회지
    • /
    • 제19권5호
    • /
    • pp.859-871
    • /
    • 2019
  • Objectives: The present study aimed to evaluate the usability, quality, and usefulness of the mobile application, CAMBRA-kids, for caries management in preschoolers. Methods: Ninety-one caregivers and preschoolers participated in the user evaluation of CAMBRA-kids. The evaluators assessed the usability, quality, and usefulness of CAMBRA-kids. The collected data were analyzed using R studio 1.2.1335 for Windows (RStudio Inc. 2018, Boston, MA, USA). The evaluations for usability, quality, and usefulness were analyzed with descriptive statistics, Kruskal-Wallis rank sum test, and Wilcoxon rank sum test. Results: On user evaluation, the quality and usefulness of the application scored >3 points, and majority of the users rated the quality and usefulness of the application as high. The quality of the application's system was the highest at 3.68 points, and the actual usage of the application was the lowest at 3.10 points. The application had the highest technological aspect score of 3.20, whereas the content related to oral health information had the lowest score of 3.10/5. Although the application showed no statistically significant differences in the quality and usefulness according to general characteristics, there was a statistically significant difference (p<0.05) between the two when compared between the caries risk group. For all items, the protector of the high-risk group evaluated the quality and usefulness of the application highly. The moderate risk group gave the lowest evaluation score for the application's quality and usefulness. The usability score of the application, according to the user version of the mobile application rating scale (uMARS), was 3.25, and the average engagement score was 2.82 (56.31%). The highest subscale score was 3.63. Conclusions: In this study, we found suitable quality, usability, and usefulness of the mobile application, CAMBRA-kids. In future, the use of this application will contribute to the prevention of dental caries among preschoolers.

안드로이드 시스템 재구성 : ApplicationServer (Android System Remodeling : ApplicationServer)

  • 이호석
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2012년도 한국컴퓨터종합학술대회논문집 Vol.39 No.1(D)
    • /
    • pp.30-31
    • /
    • 2012
  • 본 논문에서는 Android System 핵심 부분을 기존의 System Server 에 Application Server 를 더하여 2개의 서버로 재구성하는 방안을 논의한다. Application Server 는 DalvikVM 과 Application 저장/스케줄링 프로세스로 구성한다. Application Server 가 모든 사용자의 Application 을 저장하고 스케줄링하고 DalvikVM에 할당하여 실행시키도록 한다. 이 방법은 사용자 입장에서는 단순화된 Android System 구조로 인하여 응용의 개발이 용이해지고 응용의 반응도 빠르게 된다. 시스템 입장에서도 구조가 단순해져서 실행 효율이 좋아지고 메모리 사용 효율도 좋아진다.

B-ISDN 응용서비스의 개발 및 분류 (A development and classification of B-ISDN application services)

  • 이덕주;오형식
    • 경영과학
    • /
    • 제11권1호
    • /
    • pp.129-144
    • /
    • 1994
  • B-ISDN(Broadband Integrated Services Digital Network)which is defined as a service or system requiring transmission channels capable of supporting rates above 1.5 Mbps has emerged as a new future telecommunication infrastructure. B-ISDN can integrate a wide range of services and the success of B-ISDN is crucially dependent on the development of user-needing application services. The purpose of this study is the conceptual development of B-ISDN application services. We survey on the kinds of B-ISDN service, classify application areas by user groups, and develop B-ISDN application services. Finally we categorize B-ISDN application services by their application areas and necessary services.

  • PDF

An Application Based on Smart Device for Special Effect Shooting of Movies

  • Chung, Myoungbeom
    • 한국컴퓨터정보학회논문지
    • /
    • 제21권7호
    • /
    • pp.39-46
    • /
    • 2016
  • In this paper, we proposed an application which can conduct to take repetition images for special effect shooting at movies or drama using Bluetooth of smart device. The proposed application can move a camera with motors several times as the same moving after saving of the control data based on the application during specific time using Bluetooth. At the repetition moving, we do not permit to control motors of the camera by person for keeping the same start position and end position after saving the moving data. The camera motors are only moved remotely by saving data of the proposed application. We developed the proposed application and a hardware which works motors with camera to check performance evaluation. Then, we confirmed that the proposed application exactly did the same moving to the motors with camera several times according to saved data. Therefore, because the proposed application can take a same images as control remotely the motors of camera, it will be a useful technology for special effect shooting of movies or dramas.

Development of a Nitrogen Application System for Nitrogen Deficiency in Corn

  • Noh, Hyun Kwon
    • Journal of Biosystems Engineering
    • /
    • 제42권2호
    • /
    • pp.98-103
    • /
    • 2017
  • Purpose: Precision agriculture includes determining the right amount of nitrogen for a specific location in the field. This work focused on developing and validating a model using variable rate nitrogen application based on the estimated SPAD value from the ground-based image sensor. Methods: A variable rate N application based on the decision making system was performed using a sensor-based variable rate nitrogen application system. To validate the nitrogen application decision making system based on the SPAD values, the developed N recommendation was compared with another conventional N recommendation. Results: Sensor-based variable rate nitrogen application was performed. The nitrogen deficiency level was measured using the image sensor system. Then, a variable rate application was run using the decision model and real-ti me control. Conclusions: These results would be useful for nitrogen management of corn in the field. The developed nitrogen application decision making system worked well, when considering the SPAD value estimation.

환아의 심도자 시술 후 시술 부위의 모래주머니 적용효과 (A Comparative Study between the Application Group and Non-application Group of a Sand Bag on the Surgical Region after a Pediatric Cardiac Catheterization)

  • 한진경;조결자
    • Child Health Nursing Research
    • /
    • 제5권3호
    • /
    • pp.340-348
    • /
    • 1999
  • The purpose of this study was to compare degree of complication and discomfort between application ' non-application of a sand bag after 3hours, 6hours, 18hours of a cardiac catheterization. The results were as follows : 1) There was no difference in a degree of occurrence of a complication and pain of the femoral punture site between application and non-application of a sand bag after the cardiac catheterization. 2) A degree of a discomfort between application and non-application of a sand bag after the cardiac catheterization recorded the highest scores in the application group of a sand bag 6 hours after the cardiac catheterization.

  • PDF

친환경 정밀농업을 위한 입제 변량살포기 개발 (II) -송풍식 붐형 분두 개발과 살포균등도 - (Development of a Variable Rate Granule Applicator for Environment-Friendly Precision Agriculture (II) - Development of Pneumatic Fertilizer Blow Head and Its Application Uniformity -)

  • 김영주;김학진;서민;이중용
    • Journal of Biosystems Engineering
    • /
    • 제31권6호
    • /
    • pp.474-481
    • /
    • 2006
  • In this paper, a new type blow head was developed and pneumatic application system was evaluated. The blow head had one operating factor, inserting length of collecting plate, that was directly related to discharge rate and application pattern. To determine Proper blow head arrangement and application height, a blow head set was tested. Three-way ANOVA was conducted to investigate relationships between CV value, the discharge rate and inserting length of collecting plate. The discharge rate and inserting length of collecting plate were statistically significant at p=0.01, affecting uniformity of application pattern. The best CV value among the application tests was 23.3% when the application rate and application height was 23.5 g/sec and 80 cm respectively. The worst CV value was 63.3% in 111.4 g/sec. Therefore, it is necessary to increase number of blow head in a section of the boom in improve application uniformity.