• Title/Summary/Keyword: Applicability Evaluation

Search Result 1,541, Processing Time 0.025 seconds

Evaluation of Mobile Emissions Reduction Strategies Using Travel Demand Model and Analytic Hierarchy Process (교통수요모형과 의사결정모형을 이용한 자동차 배출저감정책 평가)

  • Lee, Kyu Jin;Park, Kwan Hwee;Shim, Sang Woo;Choi, Keechoo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1123-1133
    • /
    • 2015
  • This study proposed an evaluation method of mobile emissions reduction strategies for air quality management. The proposed method was considered Travel Demand Model (TDM) and Analytic Hierarchy Process (AHP), while an existing method was focused on quantitative factors. AHP of the evaluation indices of mobile emissions reduction strategies show that quantitative evaluation indices such as air pollutants and greenhouse gas reduction are more important than the political evaluation indices (Consistency with an upper plan, Policy applicability, Technical applicability and feasibility) and each weight of air pollutants and greenhouse gas reduction are found to be 0.373 and 0.218. The early scrapping policy of decrepit diesel vehicle is the best policy in the proposal method using TDM and AHP but this result differs from evaluated result by TDM or AHP respectively. These results are limited to the basic assumption and range of reduction scenarios but are expected to contribute to establish more reasonable and effective mobile emission reduction strategies.

The Study on Applicability of Manufactured Lead(II) Iodide Dosimeter for Dose Measurement in Brachytherapy (방사선근접치료 분야의 선량 측정을 위해 제조된 Lead(II) Iodide 선량계의 적용가능성 연구)

  • Yang, Seung-Woo;Han, Moo-Jae;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.789-794
    • /
    • 2021
  • Brachytherapy is a treatment in which radioactive isotopes are placed inside the body to intensively irradiate the tumor with radiation. Because brachytherapy uses a radioisotope source with a high dose rate, it is very important to know the exact location and dose of the source. However, in clinical practice, it is evaluated inaccurately with the naked eye through rulers and autoradiographs. Therefore, in this study, a dosimeter that can be used for brachytherapy was developed using a lead(II) iodide (PbI2) material, and the applicability was evaluated by analyzing the reproducibility, linearity, and PID items. As a result of reproducibility evaluation, the RSD value was 1.41%, satisfying the evaluation criteria of 1.5%. As a result of the linearity evaluation, the R2 value was 0.9993, which satisfies the evaluation criterion of 0.9990. As a result of PID evaluation, it showed only a difference of 0.06 cm compared with the theoretical value of the inverse square law of distance at the 50% dose reduction point. The dosimeter manufactured in this experiment shows results that satisfy the standard in all evaluations, so it is judged that the possibility of applying the dosimeter in the radiation brachytherapy area is sufficient.

Evaluation of Applicability of Perovskite Dosimeter based on CsPbBr3 Material to Quality Assurance in Radiation Therapy (CsPbBr3을 기반으로 한 Perovskite 선량계의 방사선치료 Quality Assurance에 대한 적용가능성 평가)

  • Yang, Seung-Woo;Park, Sung-Kwang
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.211-216
    • /
    • 2022
  • In radiation therapy, accurate Quality Assurance (QA) is required to irradiate tumor tissue while minimizing damage to normal tissue. Therefore, a dosimeter that can accurately measure radiation is needed. The purpose of this study is to develop a highly efficient radiation dosimeter with high sensitivity by applying a particle in binder method that can reduce manufacturing costs and simplify processes to perovskite materials that are cheaper and simpler to manufacture. By evaluating the response characteristics to high-energy photon, the applicability of QA dosimeter to radiation therapy was evaluated. As a result of reproducibility evaluation, RSD at 6 MV energy was presented as 1.178% and 15 MV energy was presented as 1.141%. As a result of linearity evaluation according to linear regression analysis, R2 values of 0.9999 were presented under each condition of 6 MV and 15 MV energy. It was found that the CsPbBr3 dosimeter manufactured based on the results of reproducibility and linearity evaluation is highly applicable as a QA dosimeter in the field of therapeutic radiation. The CsPbBr3 dosimeter manufactured in this study presented more than the standard performance in the evaluation of reproducibility and linearity, and it can be used as a radiotherapy QA dosimeter through improvement.

Life Prediction and AE Evaluation of Pure or Cyclic Creep for Power Plant Materials ; Pure Creep and AE Evaluation (전력용 강재의 정적.동적 크리프의 상관성과 예측 및 AE평가(1); 정적 크리프와 AE평가)

  • 오세규;장홍근;송정근
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.76-84
    • /
    • 1998
  • In this 1st report, the relationship between pure creep properties and initial strain was studied and also its acoustic emission test was performed during creep test at 500, 600 and $700^{\circ}C$. And the applicability of the acoustic emission technique was investigated to analyze the quantitive relationship between all the pure properties (creep strength, creep repture time or creep life, steady state creep rate, total creep rate, creep strain, total creep strain, etc.) and the initial strains as well as to analyze AE properties during the pure creep loading condition.

  • PDF

Development of a Self-Administered Checklist for Evaluation of the Musculoskeletal Disorders Risk Factors in Construction Industry (건설업에서 발생하는 근골격계질환 위험요인의 작업자 자가 평가용 체크리스트 개발)

  • Lee, Yun-Keun;Park, Hee-Sok;Park, Jung-Keun
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.5
    • /
    • pp.811-818
    • /
    • 2010
  • In this study, a self-administered checklist for evaluation of the musculoskeletal disorders risk factors in construction industry was developed, and its reliability and validity were studied. 10 items of the checklist were determined based on the literature review, and total 2,793 construction workers participated in the analysis of the checklist's applicability. The results from the reliability analysis showed high Cohen's kappa coefficient (0.50~0.77), and high validity was also obtained in terms of relative risk (RR 1.73~9.14). Positive predictability was relatively low (13.0~32.5%), while negative predictability was high (80.1~96.8%). It can be concluded that the checklist would be suitable as a quick filtering tool of the ergonomic risk factors.

Primate Model for the Evaluation of Vaginal Contraceptives

  • Zoneveld, L.J.D.;Bhattacharyya, A.K.;Kim, D-S;Schumacher, G.F.B.;Beluhan, Z.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.6 no.1_2
    • /
    • pp.29-36
    • /
    • 1979
  • A good animal model that simulates the human subject has not been available for the evaluation of the in vivo effectiveness of vaginal contraceptives. After careful consideration, The stumptailed macaque (Macaca arctoides) was studied for its applicability since it has a reproductive tract similar to that of the woman, is easy to handle, does not require tranquilization or anesthesia when the contraceptive is deposited, and breeds and conceives readily under caged conditions. The reported observations show the usefulness of this animal. Both postcoital sperm motility studies and breeding experiments were performed with the use of Delfen vaginal cream and K-Y jelly. K-Y jelly had no effect on the motility of vaginal spermatozoa or on the conception rate of the primates. Although Delfen vaginal cream consistently immobilized all spermatozoa in the postcoital test, half of the animals became pregnant within an average of 3.7 breeding cycles. These results illustrate the discrepancy between spermicidal tests and fertility measurements, and it is recommended that primate-breeding experiments be performed before a spermicide is evaluated in women as a contraceptive. (AM J. OBSTET. GYNECOL, 129:368, 1977.)

  • PDF

Application of Modal Pushover Analysis for Deformation Capacity Evaluation of Steel Moment Frames (철골구조물의 변형능력평가를 위한 MPA 방법의 적용성 검토)

  • 최원호;김기주;이동근
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.266-273
    • /
    • 2002
  • Pushover analysis is frequently used for evaluation of seismic performance and determination of seismic demand of a building structure in the current structural engineering practice field. However, pushover analysis has a advantage for estimation of seismic demands, which cannot account for the contributions of higher modes to response or for a redistribution of inertia forces because of structural yielding and the associated changes in the vibration properties of the structures. Recently, Chopra and Coel(2001) derived uncoupled inelastic dynamic equation of motion with several assumptions in the pushover analysis. By using this approach, pushover analysis for each mode is carried out and modal pushover analysis method, which can consider higher mode effects of the building, was suggested. The principle objective of this study is to introduced the modal pushover analysis by Chopra et al.(2001) and investigated the applicability and validity of this method for the steel moment frames subjected to various earthquake ground motions.

  • PDF

Construction and Evaluation of the Paved Track on Test Line (도시철도 시험선 구간에서의 포장궤도 시험부설 및 성능평가)

  • Lee, Il-Wha;Shim, Jae-Gyu;Lee, Choon-Ho;Park, Kyun-Seo;Ryu, Kyoung-Sik
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1115-1120
    • /
    • 2007
  • Recently, the development of the paved track is required as a low-maintenance of conventional line. The main reason is that the line capacity and bearing of track are increased progressively. The important factors of paved track are stability and applicability. To be based on this subject, Cement Mortar Pouring(CMP) paved track is developed. CMP paved track is a kind of ballast reinforced track using the prepacked concrete technique. The most important thing to design the paved track is to optimize the track structure considering various conditions. In this study, the CMP track is constructed(30m) on a test line and the track performance tested by running train to evaluation the capability and workability. The track performance are tested to confirm the vibration acceleration of the car body, wheel and track, accumulated settlement, track irregularity and crack of surface.

  • PDF

Evaluation of the rock property around TBM tunnels using seismic reflective survey data and TBM driving data

  • Aoki Kenji;Mito Yoshitada;Yamamoto Takuji;Shirasage Suguru
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.288-295
    • /
    • 2003
  • The relationship between the reflection number obtained from seismic reflective survey and the rock strength value obtained from TBM excavation is examined, and the procedure of the conversion from the reflection number to the rock strength value is proposed. Subsequently, geostatistical method is employed to evaluate the rock properties ahead of the tunnel face and around the tunnel with good precision, using both the seismic reflective survey data and the TBM driving data for the purpose of the tunnel driving and enlargement. The applicability of this evaluation method is examined at the actual tunnel site.

  • PDF

A Study on the Environment-friendly Assessment Elements for Apartment Unit Plan (공동주택 단위주호의 환경친화성 평가요소에 관한 연구)

  • Cho, Sung-Heui;Park, Ji-Seon
    • KIEAE Journal
    • /
    • v.2 no.4
    • /
    • pp.11-20
    • /
    • 2002
  • The purpose of this study is to suggest environment-friendly assessment elements for the apartment unit plan. For this, the organizing environments of a unit are classified through literature review. Those were five categories of environment: environment of solar system, light, water, green and indoor air Quality. Then, the assessment elements for each categorized environment to evaluate the environment-friendly performance were grasped definitely by examining the applicability of architectural methods or equipment technology. It is expected to suggest not only an assessment tool for evaluation but also a checklist for design in order to develope environment-friendly apartment unit plans.