• Title/Summary/Keyword: Appendage

Search Result 167, Processing Time 0.028 seconds

An Optimization for Flow Control Butterfly Valve using Grey Relational Analysis (회색 관계 분석을 이용한 유량 제어용 버터플라이밸브 형상 최적화)

  • Lee, Sang Beom;Lee, Dong Myung
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.26 no.6
    • /
    • pp.359-366
    • /
    • 2014
  • This paper considered optimization method of appending a shape on a disc in an attempt to improve core functions, which are inherent in flow characteristics. The paper also verifies the optimization method of appendage shape with a Class 150 200A Butterfly valve. Then the design of experiment (DOE) with an orthogonal array is performed to analyze the effect of form parameters by grey relational analysis and analysis of mean (ANOM). And this study sets flow coefficient as an object functions for optimization, and the conventional disc model and the optimal appendage shape on disc model are compared by computational fluid analysis. The paper concludes that an optimal appendage shape on disc model achieves wider usability by a wider operating range.

Comparison of Pre-Stain Suspension Liquids in the Contrasting Ability of Neutralized Potassium Phosphotungstate for Negative Staining of Bacteria

  • Kim, Ki-Wooh;Jung, Woo-Kyung;Park, Yong-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.11
    • /
    • pp.1762-1767
    • /
    • 2008
  • Image contrast of whole bacteria was compared in Staphylococcus aureus and Escherichia coli depending on pre-stain suspension liquids by energy-filtering transmission electron microscopy. The two bacterial strains were suspended in three most commonly used liquids for negative staining (triple distilled water [DW], phosphate-buffered saline [PBS], and nutrient broth [NB]) and directly observed without staining or stained with neutralized potassium phosphotungstate (PTA), respectively. Even though in low contrast, unstained bacteria were observed owing to their inherent electron density and cell shape in zero-loss (elastic scattering) images. After being suspended in PBS, unstained bacteria appeared to have higher contrast and more refined periphery than DW-suspended ones, and extracellular appendage structures such as fimbriae and flagella could be discerned. The unstained bacteria appeared to be invariably surrounded with electron-lucent precipitates, possibly from PBS. As far as delineation of the structures, the combination of DW or PBS suspension with subsequent staining provided the most satisfactory results, as evidenced by the high contrast of bacterial morphology and appendage structures. However, after being suspended in NB and stained with PTA, bacteria often had too high contrast or poor staining, with electron-dense aggregates around the bacteria. These results suggest that suspension with concentrated organic aliquots including broth media before PTA staining could deteriorate image contrast, and should be used only in dilute form for visualizing bacterial morphology and appendage structures. Moreover the contrast enhancement of unstained bacteria by salt granules would be advantageous in demonstrating bacterial sorption of environmental particles like heavy metals, maintaining minimal contrast for cell imaging.

Reconstruction of Atypical Tragus in Patients with Accessory Tragus or Macrotragus (부이주 및 큰이주를 동반하는 비전형적인 이주의 재건술)

  • Yoo, Won-Jae;Oh, Kap-Sung;Lim, So-Young;Pyon, Jai-Kyong;Mun, Goo-Hyun;Bang, Sa-Ik
    • Archives of Plastic Surgery
    • /
    • v.37 no.4
    • /
    • pp.443-446
    • /
    • 2010
  • Purpose: Tragus is one of the key structure of the normal shape of auricle. We experienced several cases of hypoplastic tragus with preauricular appendage. This article describes the methods of reconstruction of atypical tragus using accessory tragus or macrotragus to make better aesthetic results rather than simple excision. Methods: From April, 2004 to March, 2009, 21 patients got operations by our method. Seven patients had bilateral deformity of tragus. Mean age was 12.7 years. For 17 cases of accessory tragus, simple excision, z-plasty and interpolation flap was performed. For 11 cases of macrotragus, debulking and z-plasty was performed. Mean follow-up period was 9.4 months. Results: Reconstructed tragus looked symmetric with the opposite side in contour, size, direction and partial coverage of auditory meatus. There was no enlargement of remnant appendage for the follow up period and there was no complication such as hematoma, infection and chondritis. Conclusion: In cases of small and deformed tragus, preauricular tissue such as accessory tragus and macrotragus could be a good source of tragal reconstruction.

Feasibility of the AtriClip Pro Left Atrium Appendage Elimination Device via the Transverse Sinus in Minimally Invasive Mitral Valve Surgery

  • Shirasaka, Tomonori;Kunioka, Shingo;Narita, Masahiko;Ushioda, Ryohei;Shibagaki, Keisuke;Kikuchi, Yuta;Wakabayashi, Naohiro;Ishikawa, Natsuya;Kamiya, Hiroyuki
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.383-388
    • /
    • 2021
  • Background: Achieving external access to and manual occlusion of the left atrial appendage (LAA) during minimally invasive mitral valve surgery (MIMVS) through a small right thoracotomy is difficult. Occlusion of the LAA using an epicardial closure device seems quite useful compared to other surgical techniques. Methods: Fourteen patients with atrial fibrillation underwent MIMVS with concomitant surgical occlusion of the LAA using double-layered endocardial closure stitches (n=6, endocardial suture group) or the AtriClip Pro closure device (n=8, AtriClip group) at our institution. The primary safety endpoint was any device-related adverse event, and the primary efficacy endpoint was successful complete occlusion of blood flow into the LAA as assessed by transthoracic echocardiography at hospital discharge. The primary efficacy endpoint for stroke reduction was the occurrence of ischemic or hemorrhagic neurologic events. Results: All patients underwent LAA occlusion as scheduled. The cardiopulmonary bypass and aortic cross-clamp times in the endocardial suture group and the AtriClip group were 202±39 and 128±41 minutes, and 213±53 and 136±44 minutes, respectively (p=0.68, p=0.73). No patients in either group experienced any device-related serious adverse events, incomplete LAA occlusion, early postoperative stroke, or neurologic complication. Conclusion: Epicardial LAA occlusion using the AtriClip Pro during MIMVS in patients with mitral valve disease and atrial fibrillation is a simple, safe, and effective adjunctive procedure.

Study of the Cavitation Inception Speed (CIS) Improvement Through the Propeller Design and the Stern Appendage Modification (프로펠러 설계 및 선미 부가물 수정에 따른 캐비테이션 초기발생 선속(CIS) 성능 향상 연구)

  • Jong-Woo Ahn;Gun-Do Kim;Bu-Geun Paik;Young-Ha Park;Han-Shin Seol
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.4
    • /
    • pp.231-239
    • /
    • 2023
  • In order to improve the propeller Cavitation Inception Speed (CIS) performance, it needs to modify the propeller geometry and the wake distribution that flows into the propeller. In the previous study, the twisted angles of the V-strut were modified to improve propeller CIS, cavitation behavior and pressure fluctuation performances. Then the propeller behind the modified V-strut (New strut) showed better cavitation characteristics than that behind the existing V-strut (Old strut). However, the CIS of Suction Side Tip Vortex (SSTV) and Pressure Side Tp Vortex (PSTV) showed a big difference at behind each V-strut. In this study, the balance design is conducted to minimize the difference between SSTV CIS and PSTV CIS at behind each V-strut. To improve the propeller CIS performance, 1 propeller is designed at behind the old strut and 3 propellers are designed at behind the new strut. The propeller CIS is increased through the balance design and the stern appendage modification. The final propeller CIS is increased about 5.3 knots higher than that of the existing propeller at behind the old strut. On the basis of the present study, it is thought that the better improvement method for the propeller CIS would be suggested.

Research on the Design Methods of Appendages to Reduce Vortex Flows Around Underwater Vehicles (수중운동체 주위 와류유동 저감을 위한 부가물 형상 설계기법 연구)

  • Sang-Jae Yeo;Suk-Yoon Hong;Jee-Hun Song
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.30 no.2
    • /
    • pp.252-261
    • /
    • 2024
  • This research establishes design standards for vortex reduction devices (VRDs) aimed at minimizing underwater radiated noise by mitigating horseshoe vortex (HSV) and root vortex (RV) generated at the junction of appendages and the hull of underwater vehicles. Initial analysis replaced the influence of appendage dimensions and flow velocity with the Reynolds number by verifying the Reynolds similarity of vortex flows. The three-dimensional surfaces of VRDs were parameterized using Bezier curves. Optimal length-to-height ratios were identified by evaluating the vortex reduction performances of VRDs with various dimensions. Ultimately, non-dimensional design standards were derived for VRDs, ensuring effective vortex reduction across any appendage, thereby enhancing stealth performance.

Effect of Increase in Occlusal Vertical Dimension on Appendage Muscle Strength (수직적 교합고경의 증가가 사지 근력에 미치는 영향에 관한 연구)

  • Ahn, Su-Jin;Lee, Richard Sung-Bok;Lee, Suk-Won
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.2
    • /
    • pp.169-178
    • /
    • 2010
  • Objective. This study was conducted to observe the effect on appendage muscle strength according to increase in occlusal vertical dimension. Materials and methods. Ten males with a mean age of 21 were selected. The tested occlusal splints were made at the position of increased occlusal vertical dimension of 2mm,3.5mm and 5mm from the intercuspal position. Before and after wearing occlusal splints, the appendage muscle strength were tested by Cybex II dynamometer (Lumex Inc., Ronkonkoma, NY, USA). Results. Statistical analysis using the paired t-test revealed significant differences for flexion and extension of the hip, pronation of the forearm, internal rotation of the shoulder, external and internal rotation of the knee, and dorsiflexion and plantarflexion of the ankle (p<0.05). Conclusions. As the result of this study, we conclude that when occlusal vertical dimension was increased, most of mean muscular strength values were increased. Especially at the position of 3.5mm increased vertical dimension displayed the highest mean muscular strength value than other positions.

Assessment of the Resistance Performance of Hull Appendages Attached to Fishing Vessels Using CFD (CFD에 의한 어선 선체 부가물의 저항성능 평가)

  • Park, Dong-Woo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.267-274
    • /
    • 2018
  • A variety of appendages are attached to coastal and offshore fishing boats to improve stability during navigation or fishing operations (stability performance and roll reduction). These appendages are generally classified into three types, which are shown in Fig. 1. The numerical calculations were conducted for the following eight cases: one case of a bare hull, three cases where a single appendage attached, three cases of a pair of appendages attached, and one case where all three appendages were attached. Table 1 presents the main dimensions of the bare hull and Table 2 describes the main dimensions of the three appendages. The fluid dynamic performance with regard to the three hull appendages was evaluated via CFD for the following cases: each of the appendages attached independently, a pair of appendages attached, and all three appendages attached simultaneously. The No. 1 appendage showed that pressure resistance was proportionally greater than friction resistances. Both Nos. 2 and 3 appendages showed comparable levels of pressure and friction resistances. The correlation between appendages was minimal in the case of pairs and Comparing the cases of the No. 2 appendage attached and all appendages attached, at 11 kn, the EHP showed an difference of 9 %.