• 제목/요약/키워드: Apparatus dew point

검색결과 7건 처리시간 0.019초

이성분계 혼합물의 하부 인화점에 의한 이슬점 예측 (Dew Point Prediction by Lower Flash Points of Binary Mixtures)

  • 하동명;이성진
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.34-39
    • /
    • 2017
  • Vapor-liquid equilibrium calculation is required to properly design and operation of distillation process. The general calculation method is to use binary interaction parameter. Lower flash points of cyclohexanol+aniline and cyclohexanol+cyclohexanone were measured by using Seta-flash closed cup apparatus. The measured flash points were compared with those calculated by the method based on Raoult's law and the optimization method using Wilson equation. The absolute average errors(A.A.E.) of the results calculated by Raout's law are $0.25^{\circ}C$ and $1.07^{\circ}C$ for cyclohexanol+aniline and cyclohexanol+cyclohexanone, respectively. The absolute average errors of the results calculated by the optimization method are $0.22^{\circ}C$ and $0.65^{\circ}C$ for cyclohexanol+aniline and cyclohexanol+cyclohexanone, respectively. As can be seen from A.A.E., the calculated values based on the optimization method were found to be better than those based on the Raoult's law. The binary interaction parameters calculated by the optimization method are used to predict the dew points of cyclohexanol+aniline and cyclohexanol+cyclohexanone. The A.A.E. for these mixtures show that there is an acceptable agreement between experimental and calculated dew poins.

실내 습도 증가를 이용한 무재열 냉방시스템 개선에 관한 연구 (A Study on the Improvement of a Cooling System by the Increment of Room Humidity without Reheating Process)

  • 이홍주;김용구
    • 대한설비공학회지:설비저널
    • /
    • 제16권6호
    • /
    • pp.613-619
    • /
    • 1987
  • In a room air conditioning cooling system, if the room-sensible-heat-factor as plotted on a Psychrometric Chart intersects the saturation curve below the apparatus leaving air dewpoint, reheat must be used to maintain the design room air conditions. However, if the design room humidity is permitted to be raised to some degree, the cooling system will not require reheat as a new room-sensible-heat-factor line is developed between the apparatus leaving air dew-Point and the adjusted design room air conddition point. The advantages to this are the cost of reheat equipment and operation can be avoided. The cycle of this system can be shown on a Psychrometric Chart to plot the design condition points.

  • PDF

DRYING CHARACTERISTINCS OF THIN-LAYERS OF WHEAT AND BARLEY AT NEAR-AMBIENT TEMPERATURE

  • Sun, Da-Wen;J.J.Woods
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1993년도 Proceedings of International Conference for Agricultural Machinery and Process Engineering
    • /
    • pp.896-905
    • /
    • 1993
  • Thin-layers of wheat and barley are dried at near-ambient temperatures(3.5$^{\circ}C$ -5$0^{\circ}C$) in order to obtain the intrinsic drying data. The well established apparatus was modified to enable it to record all the sample weight data in still air by using a purpose -built automatically controlled sliding valve. The air could be diverted in less than 0.5seconds and a 7 second period was required to attain a steady weight reading. With this apparatus, very smooth drying curves were obtained. The data of sample weight , drying temperature and dew point temperature wee recorded continuously . The drying process was terminated when the moisture content change in 24 hours was less than 0.004 d.b. This was achieved by drying a sample for about a week . The final points were recorded as the dynamic equilibrium moisture content(EMC). The drying data were than fitted to the exponential Newton model and the dynamic EMC data were fitted to the Modified-Chung-Pfost Model . All the fitted parameters are given and comparison is made with previous published data. The comparisons who that the current drying constants are lower than the previous data, the dynamic EMC data obtained for wheat and barely agree with the previous data. The results show that to obtain the drying constant in the exponential Newton model, adequate drying time is necessary.

  • PDF

부하변동에 대한 바이패스 공조시스템의 특성 (The Characteristics of a Bypass Air Conditioning System for Load Variation)

  • 김보철;신현준;김정엽
    • 설비공학논문집
    • /
    • 제14권3호
    • /
    • pp.240-246
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; an outdoor air bypass, a mixed air bypass and a return air bypass system. What makes the return air by pass system more effective is that it directs all of moist outdoor air through the cooling coil. The bypass air conditioning system can maintain indoor R.H (Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. When a design sensible load (the ratio of sensible load to total sensible load) is 70 percent (at this time, RSHF (Room Sensible Heat Factor) . 0.7), indoor R.H was maintained 59 percent by the return air bypass system, but 65 percent by the conventional CAV air conditioning system (valve control system). The bypass air conditioning system can also improve IAQ (Indoor Air Quality) in many buildings where the number of air change is high.

이산화탄소와 디메틸포름아마이드 혼합물의 기포점 측정 및 모델링 (Measurement and Modeling of Bubble Points for Binary Mixtures of Carbon Dioxide and N,N-Dimethylformamide)

  • 정준영;이병철
    • 청정기술
    • /
    • 제17권1호
    • /
    • pp.19-24
    • /
    • 2011
  • 본 연구에서는 가변부피 투시창이 설치되어 있는 고압 상평형 측정 장치를 사용하여 이산화탄소의 임계온도 이상과 디메틸포름아마이드(DMF)의 임계온도 이하의 온도 범위에서 혼합물의 조성을 변화시키면서 이산화탄소와 디메틸포름아마이드 혼합물의 기포점 압력을 측정하였다. 실험적으로 측정된 기포점 압력 데이터를 Peng-Robinson 상태방정식에 상관시킴으로써 기포점 조성과 평형을 이루는 이슬점 조성을 추정하였다. 실험적으로 측정된 기포점 압력은 Peng-Robinson 상태방정식으로 계산한 결과와 매우 잘 일치하였다. 가변부피 투시창이 설치되어 있는 고압 상평형 실험장치는 고압의 압축유체 혼합물의 기포점을 매우 쉽고 빠르게 측정할 수 있는 방법이라고 할 수 있다.

디메틸카보네이트와 이산화탄소 혼합물의 기포점 측정 (Measurement of Bubble Points of Dimethyl Carbonate and Carbon Dioxide Mixtures)

  • 안준용;이병철
    • 공업화학
    • /
    • 제20권1호
    • /
    • pp.94-98
    • /
    • 2009
  • 본 연구에서는 가변부피 투시창이 설치되어 있는 고압 상평형 측정 장치를 사용하여 이산화탄소의 임계온도 이상과 디메틸카보네이트의 임계온도 이하의 온도 범위에서 혼합물의 조성을 변화시키면서 디메틸카보네이트와 이산화탄소 혼합물의 기포점을 압력을 측정하였다. 실험적으로 측정된 기포점 압력 데이터를 Peng-Robinson 상태방정식에 상관시킴으로써 기포점 조성과 평형을 이루는 이슬점 조성을 추정하였다. 실험적으로 측정된 기포점 압력은 Peng-Robinson 상태방정식으로 계산한 결과와 매우 잘 일치하였다. 가변부피 투시창이 설치되어 있는 고압 상평형 실험장치는 고압의 압축유체 혼합물의 기포점을 매우 쉽고 빠르게 측정할 수 있는 방법이라고 할 수 있다.

다층형 열교환기를 이용한 제습기의 전면 풍속 변화에 따른 성능 특성에 관한 연구 (A Study on Performance Characteristics of a Dehumidifier with Multi-layer Type Heat Exchangers Varying Frontal Air Velocity)

  • 구학근
    • 한국산학기술학회논문지
    • /
    • 제11권7호
    • /
    • pp.2323-2327
    • /
    • 2010
  • 저온환경에서의 자동화 설비, 반도체, 제조공정 및 수분 접촉이 되는 화학생산 라인 공정 등의 수분 제거를 위하여 다층형 열교환기를 이용한 제습장치를 구성하였다. 이 장치의 주요구성은 핀 피치가 다른 증발기 4대, 2대의 압축기, 2대의 응축기 그리고 팽창밸브로 각각 제작되었다. 본 연구에서는 제 1 열교환기(증발기)의 전면 풍속을 변화시켜 제습기의 성능 특성을 분석하였다. 즉, 제1 열교환기의 정면 풍속을 1.0m/s에서 4.0m/s까지 0.5 m/s의 간격으로 증가시켜 각 측정지점에서 온도와 상대습도를 측정하여 엔탈피를 구하여 각 열교환기의 냉각능력을 구했다. 그 결과 제1 열교환기의 정면 풍속이 2.0 m/s에서 각 열교환기의 냉각능력이 가장 좋은 것을 알 수 있었다.