• 제목/요약/키워드: Apparatus Capacity

검색결과 175건 처리시간 0.023초

절리면의 거칠기에 따른 암석 절리의 전단강도 및 변형거동에 관한 연구 (Shear Strength and Deformation Behavior of Rock Joint with Roughness)

  • 이상돈;강준호;이정인
    • 터널과지하공간
    • /
    • 제4권3호
    • /
    • pp.261-273
    • /
    • 1994
  • Direct shear tests were carried out on the rock joints and artificial discontinuities to investigate the influence of joint roughness on the shear strength and deformation behaviour. Single direct shear testing apparatus used in experiment was designed and manufactured. Its capacity is 200 tons of shear load, 20 tons of normal load and 50$\textrm{cm}^2$ of maximum shear area. Test samples were cement mortar with artificial discontinuity and sandstone with natural joint. Peak shear strength was increased as joint roughness or normal stress was increased, especially, linearly increased with roughness angle in cement mortar. If joint roughness angle was constant at low normal stress, shear strength was not affected by width and height of joint roughness in cement mortar. Peak shear strengths obtained from tests were larger than the values calculated by Barton's equation, and shear stiffness was increased with joint roughness coefficient.

  • PDF

담배 팽화공정에 사용된 Freon-11의 회수 (냉각 및 압축 system에 관해서) (RECOVERY OF FREOU-11 USED IN A PROCESSING SYSTEM OF TOBACCO EXPANSION (ABOUT COOLING AND COMPRESSION SYSTEM))

  • 김기환;유광근;주영석;최영현;김병구
    • 한국연초학회지
    • /
    • 제7권2호
    • /
    • pp.189-197
    • /
    • 1985
  • The purpose of this study is to improve the method and the apparatus for recovering freon-11 used in a process for increasing the filling capacity of tobacco. The first, the theoretical recovery rate of freon-11 was calculated from vapour pressure and thermodynamic properties of freon-11. The second, the usability of theoretical data was evaluated by the comparison between the theoretical data and the experimental data from the pilot plant. The result obtained under the present experiment condition was quite similar to the rate at 15kg/cm2 and 5$^{\circ}C$, but the theoretical data evaluated were 0.1 to 0.3% lower than the experimental data at 20 to 25kg/cm2 and 5$^{\circ}C$. The recovery rate of the cooling and the compression system was about 95% with freon-11 used in this system and that with freon-11 concentrate of waste gas was about 3 to 3.6% at 20 to 25kg/cm2 and 5$^{\circ}C$.

  • PDF

SMART 연구로 주냉각재펌프의 검증시험 (Qualification Test of a Main Coolant Pump for SMART Pilot)

  • 박상진;윤의수;오형우
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.858-865
    • /
    • 2006
  • SMART Pilot is a multipurpose small capacity integral type reactor. Main coolant pump (MCP) of SMART Pilot is a canned-motor-type axial pump to circulate the primary coolant between nuclear fuel and steam generator in the primary system. The reactor is designed to operate under condition of $310^{\circ}C$ and 14.7MPa. Thus MCP has to be tested under same operating condition as reactor design condition to verify its performance and safety. In present wort a test apparatus to simulate real operating situations of the reactor has been designed and constructed to test MCP. And then functional tests, performance tests, and endurance tests have been carried out upon a prototype MCP. Canned motor characteristics, homologous head/torque curves, coast-down curves, NPSH curves and lift-time performance variations were obtained from the qualification test as well as hydraulic performance characteristics of MCP.

세라믹스의 축열연소시스템 응용 (Ceramic Application for Regenerative Burner System)

  • 한동빈;박병학;김영우;배원수
    • 한국세라믹학회지
    • /
    • 제36권5호
    • /
    • pp.497-503
    • /
    • 1999
  • Recently regenerative burner system was developed and begins to be gradually used for better energy savings. Compared to conventional burner system the regenrative one has the several merits such as higher fuel efficiency light weigh of apparatus low harmful toxic gas and homogeneous heating zone etc. The regenerative material a very important component of the new regenerative burner system should possess the properties of low specific density higher surface area and high specific heat capacity. Ceramics is the best regenerative material because of stable mechanical properties even at high temperature and better thermal properties and excellent chemical stability. In this study alumina ball alumina tube 3-D ceramic foam and hoeycomb as regenerative materials were tested and evaluated. The computer silumation was conducted and compared to the result of field test. This paper is aimed to introduce a new application of ceramics at high temperature.

  • PDF

LCD를 이용한 통전상태 표시기 개발 (Voltage Application Indicator Using Liquid Crystal Device)

  • 구경완;류승헌;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1757-1759
    • /
    • 2000
  • To make a inspection and maintenance of the high voltage equipment, electric machinery to transmit and distribute the electric power, the appearance of a simple and inexpensive indicator with which the charge condition of bare conductor parts could be read at a Stance has been needed. Liquid crystal has recently been expanding its application rapidly in appliances for everyday use. Since its display energy is extremely small, it is possible to obtain the working current with simple condenser voltage divider that makes use of stray capacity when it is applied to electric power equipment. Thus, an apparatus has finally appeared which is close to the one they have sought and indicates the existence of voltage impressions.

  • PDF

3상 4선식 부하설비의 전압, 전류 및 부하 불평형율 측정 분석 (The measurement & Analysis of Voltage, Current and Load Unbalance Factor at Three Phase Four Wire Load System)

  • 김종겸;박영진;이동주;이종한;정종호;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.28-30
    • /
    • 2005
  • This paper presents a scheme on the characteristics of voltage and current unbalance factor under the load variation at the three phase 4-wire system. The voltage unbalance factor of the three-phase 4-wire system is approved by the field measurement. This system is composed of three one-phase transformer with each other capacity. Current unbalance factor is measured by the power quality measurement apparatus and compared by the load unbalance factor. Each phase has an impedance each other by the unbalanced load operation pattern and give rise to voltage unbalance.

  • PDF

CNC선삭시 주축변위센서를 이용한 편심 가공오차와 절삭력 변화특성의 검출 (Monitoring of Eccentric Machining Error and Cutting Force Variation using Cylindrical Capacity Spindle Sensor on CNC Turning)

  • 맹희영;김성동
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2005년도 춘계학술대회 논문집
    • /
    • pp.300-306
    • /
    • 2005
  • This paper presents the methodology for measuring eccentricity of the machined cylindrical part using CCS(cylindrical capacitance spindle sensor) signal in the CNC turning process. We use capacitance type sensor to take full advantage of averaging effect by using large capacitance area to encompass the whole side of a sensor. The intentionally proposed initial eccentricity is applied to the experimental testpieces, and their resultant relationships between CCS orbits and eccentricities are investigated. As a result, the possibility as a automatic detection apparatus for the CNC lathe is considered based on the linearities of CCS signal and magnitude of eccentricity of machined cylindrical surfaces.

  • PDF

대형삼축압축시험을 이용한 북제주현무암 사석재의 강도정수 산정 (Evaluation of Strength Parameters of North-Cheju Basalt Rubble Using Large-Scale Triaxial Test)

  • 정철민;김종수;채영수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.189-196
    • /
    • 2002
  • According to the Korean Design Code for port and harbor facilaties, bearing capacity of rubble mound under eccentric and inclined load is calculated by the simplified Bishop method, and strength parameters are recommended to be c=0.2kg/$\textrm{cm}^2$ and ø=35$^{\circ}$for standard rubble if the compressive strength of parent rock is greater than 300kg/$\textrm{cm}^2$, quoting from research results by Jun-ichi Mizukami(1991), But this facts have never been certified in Korea because there was not large-scale triaxial test apparatus until 2000 in Korea. Firstly in Korea, the large-scale triaxial test (sample diameter, 30cm and height, 60cm) on the rubble originated from porous basalt rock in North-Cheju was accomplished. Then strength parameters for basalt rubble produced in North-Cheju are recommended to be c=0.3kg/$\textrm{cm}^2$ and ø=36$^{\circ}$if the compressive strength of parent rock is greater than 400kg/$\textrm{cm}^2$.

  • PDF

선박추진용 HTS모터 기술분석 연구 (Research on the Technical Analysis of HTS Motor for Vessel Propulsion)

  • 김종구;김기찬;이찬주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.779-781
    • /
    • 2004
  • Recently, as the interests in the electrical propulsion ship increase, it is needed to prepare for the technical demand of the versatile HTS synchronous motor, the noble paradigm of the electrical motor. In this paper, the electrical propulsion apparatus was classified at first. The, the merits and demerits of the HTS synchronous motor were investigated. Finally, the feasibility study of development of the HTS motor was performed with electromagnetic FEM analysis. Additionally, the points to be considered in decision of the capacity or number of the HTS motor and the way to supply electricity were studied in this paper. This work would be very useful in establishing the development direction of the HTS motor

  • PDF

Estimation of Cooldown Time in Cryocooled Superconducting Magnet System

  • Choi, Yeon-Suk;Kim, Dong-Lak;Shin, Dong-Won
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.25-28
    • /
    • 2010
  • A cooldown time is one of the major factors in many cryocooler applications, especially for the design of conduction-cooled superconducting apparatus. The estimation of cooldown seeks the elapsed time to cool thermal object by a cryocooler during initial cooldown process. This procedure includes the dimension of cold mass, heat transfer analysis for cryogenic load and available refrigerating capacity of a cryocooler. This method is applied to the specific cooling system for a 3 Tesla superconducting magnet cooled by a two-stage GM cryocooler. The result is compared with that of experiment, showing that the results of proposed method have a good agreement with experiments during initial cooling of superconducting magnet.