• Title/Summary/Keyword: Apparatus Capacity

Search Result 175, Processing Time 0.03 seconds

Investigation of design values computation of wood shear walls constructed with structural foam sheathing

  • Shadravan, Shideh;Ramseyer, Chris C.
    • Advances in Computational Design
    • /
    • v.4 no.3
    • /
    • pp.223-238
    • /
    • 2019
  • This study investigated the ultimate lateral load capacity of shear walls constructed with several types of structural foam sheathing. Sixteen tests were conducted and the results were compared to the published design values commutated by the manufactures for each test series. The sheathing products included 12.7 mm (1/2 in) SI-Strong, 25.4 mm (1 in) SI-Strong, 12.7 mm (1/2 in) R-Max Thermasheath, and 2 mm (0.078 in) ThermoPly Green. The structural foam sheathing was attached per the manufacturers' specification to one side of the wood frame for each wall tested. Standard 12.7 mm (1/2 in) gypsum wallboard was screwed to the opposite side of the frame. Simpson HDQ8 tie-down anchors were screwed to the terminal studs at each end of the wall and anchored to the base of the testing apparatus. Both monotonic and cyclic testing following ASTM E564 and ASTM E2126, respectively, were considered. Results from the monotonic tests showed an 11 to 27 percent smaller capacity when compared to the published design values. Likewise, the test results from the cyclic tests showed a 24 to 45 percent smaller capacity than the published design values and did not meet the seismic performance design criteria computation.

A Study on Detection of Runout Eccentric Error Using CCS Sensor at CNC Lathe (CNC선반에서 주축변위센서를 이용한 가공편심오차의 검출에 관한 연구)

  • 양재생;맹희영
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2002.10a
    • /
    • pp.468-473
    • /
    • 2002
  • This paper presents the methodology for measuring eccentricity of the cylindricaliy machined part using CCS(Cylindrical Capacity Spindle Sensor) signal in the CNC turning process. In order to investigate the relationships between CCS orbits and eccentricities, the initial conditions for various eccentricity state and machining process is applied to the experimental strategy. AS a result, it is considered the linearities of CCS signal and magnitude of eccentricity of machined cylindrical surfaces based on the possibility as a automatic detection apparatus for the CNC lathe.

  • PDF

Hydrogen Storage by Carbon Fibers Synthesized by Pyrolysis of Cotton Fibers

  • Sharon, Maheshwar;Sharon, Madhuri;Kalita, Golap;Mukherjee, Bholanath
    • Carbon letters
    • /
    • v.12 no.1
    • /
    • pp.39-43
    • /
    • 2011
  • Synthesis of carbon fibers from cotton fiber by pyrolysis process has been described. Synthesis parameters are optimized using Taguchi optimization technique. Synthesized carbon fibers are used for studying hydrogen adsorption capacity using Seivert's apparatus. Transmission electron microscopy analysis and X-ray diffraction of carbon fiber from cotton suggested it to be very transparent type material possessing graphitic nature. Carbon synthesized from cotton fibers under the conditions predicted by Taguchi optimization methodology (no treatment of cotton fiber prior to pyrolysis, temperature of pyrolysis $800^{\circ}C$, Argon as carrier gas and paralyzing time for 2 h) exhibited 7.32 wt% hydrogen adsorption capacity.

A study on Removal of $NH_3$ Gas in a Towar using a Ralu-Pack 250YC as a Packing Material (Ralu-Pack 250YC를 충전한 충전탑에서 암모니아가스 제거에 관한 연구)

  • 김석택
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.389-392
    • /
    • 2000
  • In this study a packed tower was selected for the treatment apparatus of $NH_3$ gas produced in industry. Formerly latticework packing has been used in preventive facility of treatment of $NH_3$ gas. However recently metallic Ralu-Pack 250YC. structured packing is usually being used in petrochemical production plant. This study is for the application the packing to the $NH_3$ gas treatment in wet scrubbing process. In Air/water system hydraulic pressure drop dependent of specific liquid load and gas capacity factor was continuous and parallel from graph. The tower height can be determuined by the number of transfer unit and the height of transfer unit influenced on liquid distribution.

  • PDF

An Experimental Study on Performance of Heat Pump System Using Hydrocarbon Refrigerants by Changing Indoor Load (실내 부하 변동에 따른 탄화수소계 냉매를 이용한 히트펌프 성능에 관한 실험적 연구)

  • Kim, Jae-Dol;Seong, Gwang-Hoon;Jeong, Seok-Kwon;Yoon, Jung-In;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.204-210
    • /
    • 2006
  • This study presents heat pump system characteristics using hydrocarbon refrigerants as alternative refrigerant for R-22 with respect to the variation of indoor load. Pure R-22 and R-290. R-600a, R-1270 were considered as working fluids The experimental apparatus was constructed to investigate the performance of heat pump using the air as a heat source. The performance were calculated based on compression shaft work. refrigeration capacity. pressure ratio, discharge temperature and COP. The experimental results show that the COP and refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. Through the above. hydrocarbon refrigerants are good alternatives in the heat pump system for R-22.

Research & Development of High Capacity ECO-HVAC System (고용량 친환경적 HVAC 시스템 연구개발)

  • Park, Sung-Hyuk;Oh, Seh-Chan;Lee, Chang-Mu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.187-190
    • /
    • 2007
  • Nowadays, with urban railway vehicles, refrigeration has been used for a long time as an air conditioner including a heating apparatus and a ventilator. Regarding saveenergy, there are lots of researches continually on the refrigeration field to reduce the parts' weight, improve the parts' efficiency and make good looking design of air conditioners. Moreover, we are able to see the recent achievement of the researches. As a result, through this research we improve the quality of inner air with the urban railway system and make a domestic HVAC system by technical development of high capacity air conditioner and the principal parts.

  • PDF

Research & Development of High Capacity ECO-HVAC System (고용량 친환경적 HVAC 시스템 연구개발)

  • Park, Sung-Hyuk;Oh, Seh-Chan;Lee, Chang-Mu
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.218-221
    • /
    • 2007
  • Nowadays, with urban railway vehicles, refrigeration has been used for a long time as an air conditioner including a heating apparatus and a ventilator. Regarding saveenergy, there are lots of researches continually on the refrigeration field to reduce the parts' weight, improve the parts' efficiency and make good looking design of air conditioners. Moreover, we are able to see the recent achievement of the researches. As a result, through this research we will improve the quality of inner air with the urban railway system and make a domestic HVAC system by technical development of high capacity air conditioner and the principal parts.

  • PDF

Volumetric Hydrogen Sorbent Measurement at High Pressure and Cryogenic Condition - Basic Measurement Protocols (부피법을 이용한 고압·극저온 수소 흡착량 측정 방식의 기본 원리)

  • OH, HYUNCHUL
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.4
    • /
    • pp.349-356
    • /
    • 2016
  • Volumetric capacity metrics at cryogenic condition are critical for technological and commercial development. It must be calculated and reported in a uniform and consistent manner to allow comparisons among different materials. In this paper, we propose a simple and universal protocol for the determination of volumetric capacity of sorbent materials at cryogenic condition. Usually, the sample container volume containing porous sample at RT can be directly determined by a helium expansion test. At cryogenic temperatures, however, this direct helium expansion test results in inaccurate values of the sample container volume for microporous materials due to a significant helium adsorption, resulting significant errors in hydrogen uptake. For reducing this container volume error, therefore, we introduced and applied the indirect method such as 'volume correction using a non-porous material', showing a reliable cold volume correction.

Moisture Vapor Management Properties of Fabrics Determining Human Sensorial Comfort in Transient Conditions (동적 상태에서 주관적 착용감에 영향을 미치는 직물의 수증기상태의 수분전달 특성)

  • ;Roger L. Barker
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1073-1080
    • /
    • 2000
  • Moisture transfer property of fabrics has known as one of the most important factors deciding wearer's subjective comfort not only thermally but also of sensorial. As a decisive property of fabric materials in determining human sensorial comfort, moisture vapor management property of heat resistant workwear material was examined in terms of increasing and decreasing rate and maximum value of relative humidity in the microclimate under the sweat pulse situation. An unique moisture regulation index, B$_{d}$, was calculated from the measurements using a novel dynamic sweating hot plate apparatus and was used to assess the buffering capacity of fabrics against a moisture vapor sweat pulse.e.

  • PDF

Experimental Study on the Rapid Cooling System by Refrigerant Storage Method (냉매 저장방식에 의한 쾌속 냉각장치에 대한 실험적 연구)

  • 장기태;고준석;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.11
    • /
    • pp.937-942
    • /
    • 2003
  • In the present study, low-temperature low-pressure refrigerant storage method is proposed to achieve higher cooling capacity during a short period of time than that of a compressor in steady operation. Experimental apparatus was designed and set up to analyze the performance of the new-conceptual cooling system. Two reservoirs for sequential storage of refrigerant were used in the cooling system. Several on/off solenoid valves were installed for control of refrigerant flow. From the experimental results, the initial rapid cooling by low temperature low-pressure refrigerant storage method was ascertained for successful operation. This rapid cooling methodology shall be useful for other low-capacity refrigeration system.