• Title/Summary/Keyword: Apartments

Search Result 1,242, Processing Time 0.022 seconds

Does the placement of automated external defibrillators affect first responders' willingness to perform cardiopulmonary resuscitation in high-rise residential buildings?

  • Lee, Dong Eun;Ryoo, Hyun Wook;Ahn, Jae Yun;Moon, Sungbae;Kim, Jong Kun;Kim, Yun Jeong;Park, Jung Bae;Kim, Jung Ho;Lee, Kyung Woo;Jin, Sang Chan
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.29 no.6
    • /
    • pp.557-567
    • /
    • 2018
  • Objective: The increasing number of people living in high-rise apartments may result in a delayed response from emergency medical technicians called out for an out-of-hospital cardiac arrest, making the role of apartment managers as the first responders extremely important. This study investigated whether automated external defibrillator (AED) placement influences the willingness of apartment managers to perform cardiopulmonary resuscitation (CPR) and use an AED. Methods: A cross-sectional target population-based survey was conducted in Daegu, July 2016. Questionnaires were sent to apartment managers working in apartments with more than 500 households. The general characteristics of the respondents, status of CPR education, and knowledge about and willingness to perform CPR and use an AED were investigated. Results: Of the 1,445 respondents, 758 (52.5%) worked in apartments with AEDs, of which 77.8% and 70.8% were willing to perform CPR and use an AED, respectively, compared with 68.1% and 60.0% of respondents who worked in apartments without AEDs. After adjusting for potential confounders, AED placement was associated with the willingness to perform CPR (odds ratio [OR], 1.33; 95% confidence interval [CI], 1.04-1.71) and use an AED (OR, 1.39; 95% CI, 1.10-1.75). Prior CPR training and accurate knowledge of CPR skills were also associated with the willingness to perform CPR and use an AED. Conclusion: Placing AEDs in high-rise apartment buildings and providing refresher CPR education for maintaining CPR skills will be necessary to support apartment managers in their role as first responders.

Design and Verification of Addressable Automatic Fire Detection System for Existing Apartments (기존아파트의 적용성을 고려한 주소형 자동화재탐지설비의 설계 및 검증)

  • An, Hyunsung
    • Land and Housing Review
    • /
    • v.13 no.4
    • /
    • pp.105-114
    • /
    • 2022
  • Non-fire activated fire alarms caused by such actions as cigarette smoke, cooking, and high humidity are fire safety risk factors. In such instances, it is important to quickly locate and replace the actuated detector. However, it is difficult to locate those detectors because most do not have an address function. While new apartments can incorporate addressable fire alarm detectors, in existing apartments there are limitations in converting over to addressable detectors due to cost and power line issues. This study developed an efficient address function for fire alarms in existing apartments. The newly developed system consists of the existing receiver, and a proposed addressable repeater and detector. Utilizing an experimental setup, the performance of the proposed address monitoring system was confirmed to be stable and compatible with the receiver and existing detectors.

Evaluation of Radon Concentration according to Mechanical Ventilation Systems in Apartments (공동주택 내의 기계환기 설비에 따른 라돈농도 평가)

  • Choi, Jiwon;Hong, Hyungjin;Lee, Jeongsub;Yoo, Juhee;Park, Boram;Kim, Gahyun;Yoon, Sungwon;Lee, Cheolmin
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.4
    • /
    • pp.330-338
    • /
    • 2021
  • Background: This study was conducted to provide background information for the proper management of radon contamination in apartments using mechanical ventilation facilities in residential environments. Objectives: To this end, this study compared and evaluated changes in radon concentrations based on different operating intensities of mechanical ventilation with or without natural ventilation. Methods: For the continuous measurement of radon concentrations, an RAD7 instrument was installed in four apartments equipped with a ventilation system. The measurements were done for comparison of ventilation types and different ventilation intensities ("high", "middle", "low"). Results: The results confirmed that both mechanical and natural ventilation sufficiently reduced the radon concentration in the apartments. In particular, mechanical ventilation at "high" intensity was the most effective. Natural ventilation combined with mechanical ventilation and then natural ventilation alone were the second and the third most effective, respectively. Conclusions: When using ventilation to reduce indoor radon concentrations, it is most effective to operate mechanical ventilation ("high") or natural ventilation and mechanical ventilation at the same time. In cases where mechanical ventilation is available alone, it is recommended to operate it at a minimum of "middle" intensity.

Measures to Secure the Habitability of Temporary Shelter for Shelter in Place in Nuclear Power Plant Accidents (원전 사고지역에서 실내대피를 위한 임시대피시설의 거주성 확보방안)

  • Jeongdong Kim;Chonghwa Eun
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.582-596
    • /
    • 2023
  • Purpose: This study aims to explore the ways to improve the security of temporary shelters in case of nuclear power plant accidents. Method: In this study, we mainly rely on the case studies on previous nuclear power plant accidents-Chernobyl, Fukushima, and Three Mile Island (TMI) cases. Result: The current radiation emergency response plans for nuclear power plant accidents center around the evacuation procedure. As a result, the concept of "shelter in place" has been understood as a means of assisting resident evacuation. However, based on the case studies, we find that encouraging shelter in place, rather than simply emphasizing evacuation, would help minimize unnecessary casualties, especially in case of the accidents rated greater than or equal to INES 5. To facilitate better shelter in place, we recommend utilize apartments as temporary shelters and suggest some possible improvements to ensure those apartments could be equipped with technologies for high radiation protection. Conclusion: To ensure better shelter in place, we recommend using apartments as temporary shelters, and we seek to supplement the function of apartments by using shielding, positive pressure, and sealing technologies.

Residents' Responses and Consciousness on Sick House Syndrome of Newly Built Apartments - Focusing on Cheongju - (신축 아파트 거주자의 새집증후군 반응 및 의식 조사 - 청주시를 중심으로 -)

  • Choi, Yoon-Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.44 no.3 s.217
    • /
    • pp.103-113
    • /
    • 2006
  • The purpose of this study was to determine the present condition of sick house syndrome of newly built apartments a mid-sized city. The questionnaire survey was carried out from $19^{th}\;to\;22^{nd}$ of May 2004, with respondents consisting of 160 households living in two apartment complexes of Cheongju. Their residency periods after moving in were within $six{\sim}ten$ months. From the survey results of the respondents, sick house syndrome items revealed high percentages with the highest value of 49.3%. The respondents answered that they knew relatively well about sick house syndrome but they had no knowledge about 'bake-out'. The response percentages of sick house syndrome items in E complex, consisting of $106m^2$ (32 pyeong) size units, were significantly higher than those in A complex, consisting of $76m^2$ (23 pyeong) size units. This result suggests that the pollution levels emitted from interior materials in larger sized apartment units are higher than those in small sized units. The response percentages of sick house syndrome items in houses with fulfilled ventilation which had been ventilated before or after moving in were lower than in houses not ventilated.

A study on the Energy Consumption and the Greenhouse gas Emission intensity of Detached Houses in Daegu (대구광역시 단독주택의 에너지 및 온실가스 배출원단위 작성에 관한 연구)

  • Kim, Ju-Young;Kim, Yu-Lan;Hong, Won-Hwa
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.11a
    • /
    • pp.89-94
    • /
    • 2009
  • The purpose of this study is to provide a fundamental data for reducing energy consumption and greenhouse gas emission of detached houses by investigating the energy consumption characteristic of detached houses in Daegu. Although the ratio of the detached houses decreases, the detached houses are common dwelling form next to apartments. Nevertheless the study about the energy consumption of detached houses has been insufficient compared apartments. There is a necessity which will investigate the energy consumption characteristic of detached houses. Because that with the building quality which is various form is different from apartments. This study investigate construction and equipment conditions and analyzing effective factors on energy consumption of detached houses. And this study draw up the energy consumption unit and emission factors unit for greenhouse gas of detached houses. This study represent a basic report for energy consumption reduction and helps effective use of energy.

  • PDF

A Study on the Method of Residents-Participatory Design for Apartment Housing Remodeling (공동주택 주호개수를 위한 거주자 참여 디자인 수법에 관한 사례연구)

  • Yi, Yong-Kyu
    • Journal of the Korean housing association
    • /
    • v.24 no.4
    • /
    • pp.53-60
    • /
    • 2013
  • Apartments amount to 58.3%, the highest proportion of domestic housing types. These apartments' lifespan (approximately 27 years) are one-third of the developed countries' housing lifespan due to the property developers and mass production. It is significantly short-cycle period considering the original physical lifespan of the apartment housing are 60 years. It has caused economic loss and environmental degradation. In recent years, research and development for the long life of the apartment housing has been actively performed, but it is limited on reconstruction and new construction. Reconstruction of existing a number of high-rise apartments is difficult owing to restrictions on the floor area ratio allowing for 40 years limit of decay resistance after the completion. Improving lifespan of the building has recently begun to receive attention as an alternative to remodeling. However, These sort of remodeling techniques tend to be focused on technology developed for the physical life extension. That means developing the techniques about dwelling-unit environment for residents satisfaction are required as well as improving physical construction. The purpose of this study is to propose and verify the Participatory Design Technique which can help the residents as the active participation in the design decision-making process.

The Application of MHS Frames for Apartments of Extended Life in Korea (공동주택 장수명화를 위해 MHS 공법이 적응된 골조공법 개선방안)

  • Hong, Won-Kee;Kim, Jin-Min;Kim, Sun-Kuk;Kim, Hyung-Geun;Yoon, Ki-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.107-115
    • /
    • 2008
  • Bearing wall apartments have been introduced to meet the needs of population growth in metropolis since 1980 in Korea. It is extremely difficult to remodel bearing wall apartments. Noises and vibrations generated between floors are also problems to solve. This paper introduces rahmen structures that enable easy remodel. Modularized Hybrid System(MHS) is demonstrated to be effective in terms of material quantity, construction costs, and amount of $CO_2$ emission compared with those of bearing wall structures. Housings with MHS composite girder ensure the flexibility of architectural plan and easy remodel while the floor heights are maintained the same as bearing wall structures. The reduction of the concrete and reinforcing steels tonnage decreased construction cost of MHS multi-residential housings. The $CO_2$ omission was also diminished in accordance with the reduction of construction materials. This paper describes new structural system adapting MHS frames to propose the extended life of residential housings and reduce the national resources by preventing unnecessary rebuilding of housings.

A Study on the Applications of Pattern Language for the Shared Space Design in Apartments (아파트 공용공간 디자인을 위한 패턴언어 적용에 관한 연구)

  • Choi, In-Young
    • Korean Institute of Interior Design Journal
    • /
    • v.24 no.3
    • /
    • pp.113-120
    • /
    • 2015
  • Apartment is characterized by its various households occupying a unit each in the same building, and its shared space is important in that it supports the living, exchange of information and communication between neighbors, thereby creating a sense of community. This study focused on coming up with designs to vitalize the shared space in the apartment, and to do that, Christopher Alexander's pattern language was applied to analyze the patterns found in the apartment shared space, find improvements and propose the design methods that reflect the unique characteristics of designs in Korea. The study is mainly based on literary review and field research. (1) The definition and composition of shared space and Christopher Alexander's pattern language are examined; (2) The field research is performed to analyze the patterns in the shared space of the apartments that have been planned recently in order to find the problems and elements that can be improved; and The above is reflected and proposed as a design method. The study will help rediscover the significance of space by proposing the methodology for shared space design, encouraging the use of shared space and contributing to the enhancement of community.

A Study on the Use of Balcony Areas to Improve Fire Escape for Residents in Apartments (화재피난 방안 수립을 위한 공동주택 거주자의 발코니 사용실태 조사)

  • Lee, So-Young;Lee, Myung-Sik
    • Korean Journal of Human Ecology
    • /
    • v.17 no.3
    • /
    • pp.541-552
    • /
    • 2008
  • With the increase of apartments and expansion of balcony areas, fire safety issues are becoming more important. Many researchers have conducted a lot of researches to reduce vertical flame spread in the balcony when an apartment unit is in fire. However, there have rarely been studies to use balcony area as a space for fire escape and evacuation. The study aims to examine the conditions of balcony use in apartments in order to find out prevention elements from fire escape and evacuation, and to investigate residents' satisfaction with balcony. For this study, questionnaires were collected from apartment residents and workers of architectural planning and construction companies. The findings show as follows: first, the balcony is generally used as a storage in each apartment unit nowadays. Second, when fire breaks out, many storage items could disturb residents' safe escape by blocking escape route, and easily promote to spread flame vertically in the balcony.