• Title/Summary/Keyword: Apartment house unit shape

Search Result 6, Processing Time 0.02 seconds

A Case Study on the Evaluation of Small-Sized Apartment Houses in aspects of Universal Design - Focused on the 18 pyung Apartment Houses - (소형 아파트 주거환경의 유니버설 디자인 적용성 평가연구 - 전용면적 18평형 아파트를 중심으로 -)

  • Oh, Chan-Ohk
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.2
    • /
    • pp.20-30
    • /
    • 2013
  • This study was intended to suggest that new small-sized apartment houses should be designed and provided on the base of the concept of universal design. This is based on the diversity of each resident, that is, resident of not as a family, but as an individual. On the background of this, this study evaluated the small-sized apartment house in aspects of universal design. The walk-through and the residents' evaluation were carried out by using 60 items related to the principles of universal design. The 18 pyung apartment complex and housing unit in Jangyou new town area was evaluated. Also, 100 residents living in that apartment housing unit were asked to evaluate these 60 items by using 5 point Likert scale. The walk-through with measuring and taking pictures was carried out by researchers. In general, the apartment house was not met the fundamental elements of universal design. Thus, it was not appropriate for the disabled or the elderly to live in. Specially, the door width of bathroom and kitchen balcony was too narrow to pass through. Also, the floor of entrance and bathroom was not flat, so that the wheelchair user cannot enter by alone. The residents evaluated negatively many items related to design, such as shape, color, and material. Therefore, in order to provide the living environments for diverse residents such as the elderly, or the disabled to live together, the new small-sized apartment houses should be designed on the base of the principles of universal design.

Evaluation and Analysis of Building Energy Rating System Accroding to Insulation Performance of Building Envelope in Regional and Building Form of Apartment House (지역 및 주동형태별 공동주택 외피 단열 성능에 따른 건물에너지효율등급 평가 및 분석)

  • Kim, Min-Kyu;Park, Hyu-Soon;Song, Kyoo-Dong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.49-54
    • /
    • 2013
  • In field of apartment housing currently, insulation technology is the most effective way because it is common to improve the thermal performance, therefore, it is contributed to energy saving as several regional insulation standards and legal mandate method. In addition, by applying of building energy efficiency rating certification system, it has inspired voluntary energy conservation commitment for the building owner or facility manager by making a plan to evaluate and verify building energy performance. However, these circumstances are not enough to acquire a grade 2 of higher information. Therefore, in this study, we analyzed the impact of building energy efficiency rating and confirmed reduction ratio compared to the standard housing on the basis of recent our nation building law when we had changed the shape of windows and wall insulation performance and shapes of housing.

The Optimization Method of Symmetrical Building Plan Using Point Group Theory (포인트그룹 이론을 이용한 대칭적 건물 평면형태의 최적대안 결정방안)

  • 진경일
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.75-82
    • /
    • 2003
  • The symmetry is general geometric design principal in contemporary architecture shape. But, Symmetry sometimes easily causes unreasonable design. In some reason, two of symmetric units in the apartment, one side of unit have very reasonable plan and arrangement but opposite side unit nay not. For example, if the kitchen on right unit had right-handed arrangement, the symmetrical other would have left-handed kitchen arrangement. In addition to this, if each house unit has the same plan but different direction, each unit has different usage or affects the residents' life pattern. Nevertheless, Architects use only one unit plan to design public housing development by using symmetric operator (mirror, proper rotation, inversion center) at their option. This study suggests that using group theory and mathematical matrix rather than designer's discretion can solve this symmetry problem clearly. And, this study analysis the merits and demerits between each symmetrical pair of unit plan shapes by using mathematical point group theory and matrix.

An Analysis on Floor Planning Characteristics of Rural Houses in Na-po Munwha Village - A Comparison with Literature Review of Apartment Unit Plan - (나포 문화마을 주택의 평면적 특성 분석 - 도시 아파트 평면 특성의 문헌고찰 비교 -)

  • Ryou, Ok-Soon;Choi, Byung-Sook
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.23-32
    • /
    • 2007
  • This study was to find out contemporary planning characteristics of rural houses in Na-po Munhwa village by analyzing their floor plans. These results were then compared with apartment housing trends. 240 houses were built in that village, but it was only possible to collect housing data, floor plans and general building records from 102 houses, using house registers. By analyzing those data, the findings were as follows: 1) Floor plan shapes of rural houses showed a tendency to words a 'ㅋ' shape, a 3bay or a transformed 3 bay and a "room-living-room" space arrangement of a centered living room. Public spaces (L.D.K) were separately planned DK from livingroom. Living space was very open and the DK space had created visual privacy from the entrance. The Anbang (master bedroom) and living space were set to the front of the floor plan and an interior toilet was planned in them. These floor-planning tendencies were similar to trend apartment houses in urban areas. 2) Utility and Balcony spaces as a support space of kitchen were not popular features of rural houses in the Munhwa village. These results were different from urban apartment housing trends. 5) Storage space practically absent in those rural houses, and this was similar to urban the trends in urban apartment houses.

A Study on the Improvement of District Unit Plan in Apartment Housing with the Increase of 1~2 person Households (소가구 증가에 대응한 공동주택지 지구단위계획 개선방안)

  • Yoon, Jeong-Joong;Choi, Sang-Hee
    • Journal of the Korean Regional Science Association
    • /
    • v.34 no.3
    • /
    • pp.29-42
    • /
    • 2018
  • Population growth in Korea is slowing down, and the ratio of 1~2 person households has exceeded 53.3% of the total. And in the future, it is becoming more important how to accommodate as proper planning in residential areas. In this paper, we examine whether the existing district unit plans respond appropriately to the trend of the increase in small-sized housing, and we propose improvement plans for elements of the district unit plan and measures to enhance its applicability in response to small-sized housing. To do this, we analyzed the guidelines and contents of the district unit plans related to small-sized housing in recent 6 residential sites, and derived problems and improvements through literature review and expert consultation. As a result of the study, we proposed the items that need to be reflected in the district unit plan related to various housing type for one person household. And planning elements related to households, housing site, building layout, and architectural shape and appearance were also proposed, which were suitable for single-person households, such as small-sized communal housing, share-house, and single-person housing. It also suggested that single-person households should be considered for housing characteristics, including introduction of auxiliary welfare facilities such as unmanned delivery box and guest houses, and exclusion of low-demand auxiliary welfare facilities such as kindergartens. The suggested content can be used to make guidelines for small-sized housing in district unit plan.

A Study on the optimized Performance Designing of the Window of the Apartment based on the Annual Energy Demand Analysis according to the Azimuth Angle applying the Solar Heat Gain Coefficient of the Window (창호에 SHGC를 반영한 공동주택의 방위각별 에너지 효율성 평가를 통한 합리적인 창호 계획 방안 연구)

  • Lee, Jang-bum
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.35 no.11
    • /
    • pp.25-34
    • /
    • 2019
  • It is important to design windows in a reasonable way considering the performance characteristics of the elements of the window rather than just to increase the thermal energy performance of the window. In this study, the Heat-transfer Coefficient as insulation performance of the windows and together with the grade of the glass's SHGC (Solar Heat Gain Coefficient) were analyzed to relate to the energy efficiency performance of the building by azimuth angle. Based on this basic study, the Heat-transfer Coefficient of windows and the SHGC rating of glass were applied to the unit plan of apartment building, and the Heating and Cooling Demand were analyzed by azimuth angle. Apartment plan types were divided into 2 types of Non-extension and extension of balcony. The designPH analysis data derived from the variant of the Heat-transfer Coefficient and SHGC, were put into PHPP(Passive House Planning Package) to analyze precisely the energy efficiency(Heating and Cooling Demands) of the building by azimuth angle. In addition, assuming the 'ㅁ' shape layout, energy efficiency performance and potential of PV Panel installation also were analyzed by floors and azimuth angle, reflecting the shading effects by surrounding buildings. As the results of the study, the effect of Heat Gain by SHGC was greater than Heat Loss due to the Heat-transfer Coefficient. So it is more effective to increase SHGC to satisfy the same Heating Demand, and increasing SHGC made possible to design windows with low Heat-transfer Coefficient. It was also revealed that the difference in annual Heating and Cooling Demands between the low, mid and high floor households is significantly high. In addition to it, the installation of PV Panel in the form of a shading canopy over the window reduces the Cooling Load while at the same time producing electricity, and also confirmed that absolute thermal energy efficiency could not be maximized without controlling the thermal bridge and ventilation problems as important heat loss factors.