• Title/Summary/Keyword: Apartment construction

Search Result 1,415, Processing Time 0.033 seconds

Analysis of Factors and Preventive Effects of Crack in Educational Facilities Using Quadrant Analysis Techniques (사분면 분석기법을 활용한 교육시설 균열하자 발생 원인 및 예방효과 분석)

  • Park, Hyun Jung;Kim, Moon Sik;Kim, Hyoung Woo;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.773-784
    • /
    • 2023
  • Since 2007, the government has been actively working to enhance the quality of public buildings, as evidenced by initiatives like the "National Basic Architecture Plan" and, since 2014, the "Building Service Industry Promotion Act." Despite these efforts, educational facilities continue to experience more frequent defects compared to large-scale apartment constructions. This study aims to analyze the primary causes of crack formation in educational facilities, employing the 2×2 MATRIX and IPA techniques to develop efficient crack prediction models. The research includes a review of relevant literature and an analysis of data from the Office of Education spanning 2019 to 2021 to pinpoint significant defects. Subsequently, 15 factors related to crack defects were identified through surveys and expert consultations. The 2×2 Matrix analysis of these factors highlighted the challenges in work processes and the effectiveness of preventative measures for crack formation, focusing on key areas for improvement. The findings from this study are anticipated to significantly contribute to the prevention and management of structural cracks in educational facilities, ensuring their long-term integrity.

A Study on the Development for Prediction Model of Blasting Noise and Vibration During Construction in Urban Area (도시지역 공사 시 발파 소음·진동 예측식 개발에 관한 연구)

  • Jinuk Kwon;Naehyun Lee;Jeongha Woo
    • Journal of Environmental Impact Assessment
    • /
    • v.33 no.2
    • /
    • pp.84-98
    • /
    • 2024
  • This study proposed a prediction equation for the estimation of blasting vibaration and blasting noise, utilizing 320 datasets for the blasting vibration and blasting noise acquired during urban blasting works in the Incheon, Suwon, Wonju, and Yangsan regions. The proposed blasting vibration prediction equation, derived from regression analysis, indicated correlation coefficients of 0.879 and 0.890 for SRSD and CRSD, respectively, with an R2 value exceeding 0.7. In the case of the blasting noise prediction equation, stepwise regression analysis yielded a correlation coefficient of 0.911 between the prediction values and real measurements for the blasting nosie, and further analysis to determine the constant value revealed a correlation coefficient of 0.881, with an R2 value also exceeding 0.7. These results suggest the feasibility of applying the proposed prediction equations when environmental impact assessments or education environment evaluation according to urban development or apartment construction projects is performed.

The Research on The Stability as Fill Material of Soil Defiled by Oil Element and Heavy Metals (중금속 및 유류로 오염된 토질의 성토재료로서의 안정성에 관한 연구)

  • Lee, Chung-Sook;Eom, Tae-Kyu;Choi, Yong-Kyu;Lee, Min-Hee
    • Journal of the Korean GEO-environmental Society
    • /
    • v.5 no.2
    • /
    • pp.5-13
    • /
    • 2004
  • In the site for apartment construction, the contaminated soils of the heavy metal and the oil were appeared. The representative soil samples were sampled at 7 sampling points. To confirm the geotechnical stability of the contaminated soils, the environmental checks for the heavy metal and the oil. The soils of 2 sampling points were contaminated heavily, so it was estimated that these soils must be disused. For 1 sampling point of the slightly contaminated soil, to confirm the re-applicability of fill material, the stability analysis was performed and it was concluded that this soil will be able to re-use.

  • PDF

Analysis on Characteristics and Related Factors of Indoor Air Quality in Newly Built Wooden Houses (신축목조주택의 실내공기질 특성 및 관련요인 분석)

  • Choi, Yoon-Jung;Lee, Jae-Kyung;Cha, Ye-Rang
    • Journal of the Korean housing association
    • /
    • v.26 no.4
    • /
    • pp.23-32
    • /
    • 2015
  • The purpose of this research is to analyze characteristics and related factors of IAQ (Indoor Air Quality) in newly built wooden houses by measuring pre and post occupancy. The subjects were five wooden houses which were built with similar materials and completed from July to December 2013. Measuring factors were TVOC, HCHO, PM10, $CO_2$, CO, indoor temperature, and relative humidity. As the result of pre occupancy measuring, the houses that revealed the lowest TVOC concentration or HCHO concentration were satisfied with "the standard for newly built apartment houses". Therefore, IAQ by the wooden structures is considered to be in good condition. However, in cases of partial value exceeded the standard, the reason is analyzed to be the materials of molding, wrapping doors, built-in closet, or kitchen furniture, etc. rather than structure materials. Most PM10 concentration level showed slightly below "the standard for occupied multi-use facilities". Remaining of construction dust was considered to be the reason. As the result of post occupancy measuring, every value except of one subject's TVOC concentration was lower than pre occupancy, explaining the importance of natural ventilation.

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • v.17 no.2
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

Proposing provisions of Standard Repair Method of Painting Work Defect by Lawsuit Case Study

  • Seo, Deokseok
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.16 no.2
    • /
    • pp.1-9
    • /
    • 2017
  • Defect dispute in apartment building has become a debating social issue. The system of defect lawsuit and the conciliation process are applicable to solve defect problems in South Korea. Among various defects, painting work defect is a critical issue because it requires large area works and entails a lot of cost. Accordingly, disputes on work procedure and cost calculation are argued oftenly between residents and housing providers. This study reviewed detailed main issues of painting work and propose relevant systems and standards. In this analysis, the main issues are categorized into pre-works, main work, and others. The most recent cases are compared and analyzed for each issue. After the analysis, following conclusions are obtained, (1) In defect lawsuit system, even though surface treatment work in pre-work step is part of main work, it has been separated and regarded as a separate work. (2) Although the main painting work are not significantly different from two systems, it is still necessary to achieve a consensus to close the gap in the methodology of painting area calculation and determining whole painting or partial painting. (3) In addition, unlike the profit rate of general construction works, that of painting work remained the maximum rate and additional charge rate for works carried out in higher place are different among cases. Therefore, it is determined that establishing consistent standards is urgent.

A Study on the Sound Insulation for Void-deck Slab Combined with Deck Plate and Polystyrene Void Foam (데크플레이트와 경량성형재가 결합된 슬래브의 차음성능에 대한 실물실험 평가)

  • Roh, Young-Sook;Yoon, Seong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.60-65
    • /
    • 2015
  • This study is to explore floor impact sound and sound insulation of reinforced concrete structure with void-deck slab system which combines polystyrene void foam and T-shaped steel deck plate. A void-deck slab system can effectively reduce the amount of concrete used and hence the mass of a reinforced concrete slab. Also void slab system has dynamically favorable for bending. Three-bay 2-story building was constructed as a mock up test specimen using void-deck slab system and floor impact sound was measured to valuate sound insulation performance. Light weight floor impact and heavy weight floor impact were investigated. Light weight floor impact pressure levels were 32dB, 28dB, and 29db at representative locations which are $1^{st}$ level in the floor impact sound insulation performance grading system. The heavy-weight floor impact pressure levels were 44dB, 45dB, and 43dB at representative locations which are $2^{nd}$ level in the floor impact sound insulation performance grading system. Therefore void-deck slab system can be used in public housing apartment building in terms of not only effectively reduced construction materials but also floor impact sound insulation.

Structural Equation Model for Customer Satisfaction Index for Ubiquitous Home Network System (유비쿼터스 홈 네트워크 주거환경 만족도 증진을 위한 구조방정식 모형 연구)

  • Chun, Soo-Bong;Woo, Nam-Min;Yi, Jae-In;Sohn, So-Young
    • Journal of Korean Society for Quality Management
    • /
    • v.35 no.4
    • /
    • pp.26-37
    • /
    • 2007
  • The demand of ubiquitous home network system is rapidly increasing in Korea as each construction enterprise makes a huge effort to introduce it to apartment complex. However, the design of home network system is rather technology oriented than the customer focused. Lack of knowledge about customer needs is an obstacle in spreading the ubiquitous home network system to the market regardless of technology development. In this paper, we propose a HCSI(customer satisfaction index for home network system) using an SEM(structural equation model) where structural relationship among several factors influential on users' satisfaction is considered. This model enables to calculate the satisfaction index for target customer group so that one can provide necessary feedback information for improvement of the home network system used for each group.

The Perceptions and Satisfactions of High-Rise Mixed-Use Apartments' Common Space and Family Community (주민공동체 활성화를 위한 주상복합 주거의 공유공간에 대한 인식과 만족도)

  • Choi Jae-Soon;Kwak In-Suk
    • Journal of the Korean housing association
    • /
    • v.16 no.6
    • /
    • pp.29-38
    • /
    • 2005
  • Housing consumers prefer high-rise mixed-use apartments because of one-stop living style, and high quality of life. This study investigated the residents community with the residents who lived in the apartments and the future residents who will live in the apartments to investigate the usage of the public spaces and the influence of the space to form housing culture of residents family community. All data were taken from the response of two hundred forty three questionnaire to be gathered during 20th of June through 24th of August in 2003. Data were analyzed with percentages, means, t-test, and variance analysis using SPSS/PC+. Residents in four high-rise mixed-use apartments feels that the public space in the apartments were mainly provided by their convenience of the construction companies not for the residents. Physical conditions of public space in high-rise mixed-use apartments should be environmentally friendly housing space in which nature and human can be coexisted. It also should be high-tech system housing with which SOHO can be operated. And different custom-made spaces which the residents' needs can be satisfying should be provided. The public space should be recommended to be multi-purposed room because the space will be differentiated with the circumstances of the area, the residents' age differences, and the variety of the family's life style. Moreover, the various programs should be supplied to run the public space efficiently.

A Study on the Development and Application of Movable Partition Components for Facilitating of Long-life Housing (장수명 주택의 활성화를 위한 가동칸막이벽체 개발현황 연구)

  • Lee, Sung-Ok;Kim, Soo-Am
    • Journal of the Korean housing association
    • /
    • v.21 no.6
    • /
    • pp.91-98
    • /
    • 2010
  • The purpose of this study is to develop the feasibility of movable partition wall components that are able to correspond changes of structure system and spatial configuration by the needs of residents for the activation of long-life housing. The key element of various movable partition wall components, a movable partition wall, was analyzed for problems through both as-is analysis and field installation in Korea and Japan, and then its feasibility was verified. The movable partition wall can break the uniformity of a fixed one, can integrate and separate limited space by changes in the demands of residents, can be easy to separate, and can be independent. The development of the movable partition wall is important for the realization of diverse residential space, ease of remodeling, environment adaptation, promotion of modularization, etc. It is comprised of surfacing materials, core materials, structural materials, and movable parts. The domestic movable partition wall was verified regarding the feasibility of an apartment house through on-site inspections and sound insulation tests by KOHP21, KICT. In conclusion, the construction of long-life housing that has sustainable values in the use of housing is nationally an important assignment, so as to secure good housing stock.