• Title/Summary/Keyword: Apartment buildings

Search Result 789, Processing Time 0.029 seconds

Influence Factors of Aerial Environment on Project Schedule Management

  • Hong, Jun-pyo;Lim, Hyoung-chul
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.608-611
    • /
    • 2015
  • The objectives of this research are 1) control of schedule or improvement of management for aerial environment, 2) distribution of responsibility to the parties concerned (factory, material company, construction company, design and engineering, occupancy). The results show the relative priority of the four major items in wall-based apartment buildings and in column-based apartment buildings. An analysis of the parties responsible for improvement based on the IAQ results shows more efforts to improve IAQ are needed in material factories and engineering/design companies.

  • PDF

Occupants Control Patterns of Indoor Shading Devices in Apartment Buildings (공동주택 거주자의 실내 차양장치 사용행태에 관한 연구)

  • Lee, Yoon Jeong;Kim, Jeong-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.12-20
    • /
    • 2014
  • There is no comprehensive consensus of the control patterns people op::rate shadings or the motivating factors that influence their decisions. Patterns of shading devices use can affect the energy consumption of buildings. Therefore, this study aims to analyze shading device usage patterns based on the physical factors that can affect occupants behavior. First, control patterns of indoor shading devices in apartment buildings were monitored by taking pictures. Next, frequency of shading device use together with their shading portions was analyzed based on two physical factors such as window orientation and floor level. The results showed that about 35% of the monitored apartment buildings utilized indoor shading devices. Also, the south-facing apartments were more dynamically used than their east-facing counterparts. On the contrary, there was no general trend in regards to the shading operation patterns.

The Comparison of Apartment Management System between Korea and America (한국과 미국의 공동주택 관리제도 비교)

  • Kang, Hye-Kyoung
    • Korean Journal of Human Ecology
    • /
    • v.15 no.5
    • /
    • pp.867-878
    • /
    • 2006
  • This research is carried out to investigate the Condominium Management System of the states of California and Hawaii, and to examine the similarities and the differences between the Korean Apartment Management System and the American Condominium Management System. The research indicates: first, in Korea the management of apartment units is the Commission of the Representatives of the Occupants, while in America the management of condominiums is the Association of Apartment Owners, an organization of condominium owners in America. Second, it is required that apartment developers should submit such a document as the Public Report in America, which explains various matters concerning legal rights on condominium buildings and the outline of the buildings, to the authorities concerned in Korea. It can help the authorities to accumulate management techniques of the apartment complex, which could efficiently be used in practicing and planning city housing policies. Third, each apartment's management company in Korea is bound to make long term plans for maintenance based on the Housing Law. It is, however, difficult to reserve an adequate amount of money for the reserve fund, because its use is decided according to the maintenance rule which has a criterion different from each and every apartment management. Concludingly, an amendment of the Housing Law in Korea is required, in order to reserve at least 50 percent of the estimated sum of maintenance expense in future like Hawaii State in America.

  • PDF

A Study on the Electrical Load Matching Analisys for the optimal utilization of grid-conntected PV system in Apartment Complex (공동주택의 태양광시스템 적용성 평가를 위한 전기부하 매칭 해석연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul;Park, Jae-Wan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.49-54
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex enough the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performing with the hourly simulations of total received insolation on each surface considering the hading effect of buildings. Electrical load profile of typical Korean apartments was investigated for the lad matching analysis. To calculate an annual total PV output, we used MERIT program which is a sourly based load matching tool developed by ESRU. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending of a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡ type revealed the best option for the maximum output of PV system.

  • PDF

A Study on the Power Saving Fraction of Site Electrical Load depending on the installation area of PV system in Apartment Complex (공동주택 단지 배치유형별 PV시스템 최적 설치면적 및 전기부하 기여율 평가 연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.60-66
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex through the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the shading effect of buildings. Electrical load profile of typical Korean apartments were investigated for the load matching analysis. To calculate an annual total PV output, we used MERIT program which is a hourly based load matching tool developed by ESRD. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending on a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡtype revealed the best option for the maximum output of PV system.

Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings (외기 중 미세먼지의 공동주택 실내 유입에 관한 연구)

  • Bang, Jong-Il;Jo, Seong-Min;Sung, Min-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.

The Replacement Plans for Aged Public Water Supply Pipes in Apartment Buildings : Especially Apartment Buildings in Bucheon (공동주택의 노후 급수관 개선방안에 관한 연구 : 부천시 공동주택을 중심으로)

  • Lee, Yong-Hwa;Heo, Yong-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.4
    • /
    • pp.228-232
    • /
    • 2015
  • The water supply galvanized steel pipes of apartment buildings in Bucheon city constructed with building permission before 1994 have many problems such as leaks, the water containing rust, and low water pressure due to corrosion. Therefore, this study aims to find a way to renew the water supply pipes under investigation through a survey. As a result, when replacing the galvanized steel pipe with the corrosion-resistant pipe, the water supply system should also be changed from the gravity tank system to the booster pump system and the hygienic water storage tank. It is necessary to redraft the long-term repair plan including the replacement of the water supply system. Also, it is necessary to save the allowance reserve according to the modified long-term repair plan.

Correlation Analysis between Energy Exclusive Dwelling Area and City Gas in Apartment Building - Focused on Cases in Ulsan, Korea-

  • Lee, Young-A;Park, Hung Suk;Son, Kiyoung
    • KIEAE Journal
    • /
    • v.15 no.2
    • /
    • pp.45-52
    • /
    • 2015
  • Purpose: Currently, since the energy consumption of apartment buildings is on the rise, it is necessary to reduce the total amount of the energy through the survey and analysis of energy consumption data. Although various studies for energy efficiency have been conducted, studies are more focused on the measurement of energy by using analysis tools. In addition, the studies are sufficient to analyze real data of the city gas in apartment buildings. Therefore, the objective of this study is to identify the property of annual and $1m^2$ city gas amount according to the exclusive dwelling area. Method: To achieve the objective, this study used the statistics such as descriptive, correlation, and analysis of variance (ANOVA) analysis. Result: As a result, there is positive relationship between the annual average of city gas and the exclusive dwelling area. However, in the case of $1m^2$ city gas amount, a negative relationship is mored. In the future, the findings of this study can be applied to develop the prediction model of the city gas consumption and implement it as basic data for energy efficiency of apartment buildings of future.

A Study on the Prediction Method of Condensation on the Curtain Wall of the High-rise Apartment Unit (초고층 아파트의 커튼월 결로 예측 방법에 관한 연구)

  • Im, Jeong-Hui
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.41
    • /
    • pp.88-101
    • /
    • 2007
  • Recently, the condensation of walls often occurring in domestic high-rise apartment buildings is an important problem. The main purpose of this study is to develop the prediction method for the surface condensation on curtain wall in high-rise apartment buildings. Therefore, in this study, we first analyzed exterior climate factors through the analysis of the Seoul climate data and predicted the change of indoor temperature by using Apache program to find the cause of the condensation state and to prevent condensation. Also, according to this result, exterior climate factors and interior factors, which caused the condensation, was examined. The thermal performance of the curtain wall and the range of potential condensation were analyzed to focus on high-rise apartment buildings through computer simulation programs. The results are as $follows;^1$) The frame edge of curtain wall has a higher U-value than in the center by $30%^2$) Because of stack effect, the rooms on the higher floor have a lower external ventilation rate resulting to a higher relative humidity3) Installing a ventilation system($20m^3$/h. person) makes it possible to have a higher external ventilation rate, resulting to a lower relative humidity.

  • PDF

The Analysis CO2 Emission and Economic Efficiency of High-rise Apartment Houses (초고층 공동주택의 CO2 배출량과 경제성 분석에 관한 연구)

  • Roh, Seung-Jun;Tae, Sung-Ho;Kim, Tae-Hyoung;Keum, Won-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.05a
    • /
    • pp.47-48
    • /
    • 2012
  • In this study, the CO2 emission and economic efficiency of high-rise apartment houses were evaluated, and were analyzed as a way to establish database on the evaluation of environment-friendliness of high-rise buildings. To that end, standard of buildings to be evaluated were proposed through analysis of the designing guideline for high-rise apartment houses proposed by Seoul city, and CO2 emission of the subject buildings were evaluated based on the characteristics of materials admitted into each building and the amounts of energy consumed during lifecycle period. In addition, the initial costs in construction stage and annual costs in operation stage were set as analysis parameters, and along with calculation of direct cost by the consumption of construction materials and energy, the costs of CO2 emission were evaluated and analyzed. As a result, the CO2 emission and economic efficiencies of high-rise apartment houses by construction stage and operation stage could be analyzed quantitatively.

  • PDF