• Title/Summary/Keyword: Apartment Units

Search Result 206, Processing Time 0.025 seconds

A Study on The Performance of Ventilation and Maintaining Thermal Environment for a Combined Type Diffuser (급·배기 일체형 디퓨저의 환기 및 온열환경 유지성능에 대한 연구)

  • Lim, Seok-Young;Chang, Hyun-Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.6
    • /
    • pp.232-241
    • /
    • 2016
  • Installing a ventilator for an apartment house composed of over 100 dwelling units was mandated in 2006 to improve indoor air quality. In the case of mechanical ventilators, the air change rate is kept stable, however 68% of dwellers do not operate their ventilator because of an increased electrical bill and noise. In the case of natural ventilators, the former problems are settled, but there are concerns about cold draught and an increase of heating/cooling cost. Authors are developing a heat recovery type natural ventilator which is a natural ventilator equipped with total heat recovery element, and it is expected that those problems of mechanical ventilator and natural ventilator are resolved by this. The combined type diffuser of this study is an under developed fit to the heat recovery type natural ventilator above. There are no standards to evaluate the performance for this type of diffuser. Due to this issue this study investigated the performance of the ventilation and maintained a thermal environment for the combined type diffuser by comparing it with existing diffusers. The results revealed that the performances of the combined type of diffusers showed different features from the existing ones, and was estimated to be high enough in the performances above.

A Study on the Durability Evaluation Criteria for the Vertical Extension Remodeling of Apartment (수직 중축형 리모델링 안전진단 내구성 평가기준 합리화에 관한 연구)

  • Yoon, Sang-Chun;Shin, Dong-Cheol
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.197-205
    • /
    • 2020
  • In 2014, The Housing Act amended to allows vertical extension and increases the units of housing (or total floor area) to site. Currently, the feasibility of performing vertical extension is evaluated based on safety diagnosis provisions and manuals with 1st investigation stage on slope, uneven settlement, load-bearing capacity, and durability. However, a need for more reasonable evaluation criteria for the investigation is still required because there had not been any other case study on the diagnosis for the vertical extension, and the engineering basis on evaluation criteria were not suggested. Accordingly, this study is intended to suggest feasible evaluation criteria on the carbonation, chloride ion contents, corrosion of reinforcements, crack and surface deterioration of concrete for durability assessment by codes and standards of domestic and foreign countries. The results of this study are expected to be beneficial for establishing more reasonable durability evaluation criteria, and in turn, more reliable assessment protocol for vertical extension.

Empirical Application for the Urban Disaster Risk Assessment : Fire, Facility and Escape Cases in Cheongju City (도시 재해위험도 평가 모형 연구 - 화재, 시설, 피난위험도 중심의 청주시 사례 -)

  • Hwang, Hee-Yun;Baek, Ki-Young;Park, Byung-Ho;Lee, Man-Hyung;Hwang, Jae-Hoon;Ryu, Eul-Leal;Kim, Tae-Hwan
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.1 no.2 s.2
    • /
    • pp.123-137
    • /
    • 2001
  • Based on basic characteristics of urban disasters and their data availabilities in Korea, this study provides risk assessment models which are derived from Cheongju examples. In specific, the application models are confined to fire, facility and escape risk survey results in the paper. For the assessment criteria, major independent variables for the categories of fire include both the frequency levels and the amount of damage. And the degree of facility risk assessment is heavily hinged on both the weighted values of key facilities and their weighted rank-sizes. In the same context, the degree of escape risk assessment is hinged on both the weighted values and the amount of the classification of land. From the empirical configuration, this paper presents that the potential figure of fire risk is relatively higher in the built-up areas within the existing Central Business District where accommodates a number of dilapidated housing units and community-supportive facilities. In contrast, the potential figure of facility and escape risk is higher in both old residential areas and the newly-built apartment complex. In short, the CBD and its neighboring residential areas record a high potential figure in terms of total risk, juxtaposing fire, facility and escape risk all together.

  • PDF

Efficient Floor Vibration Analysis in A Shear Wall Building Structure (벽식구조물의 효율적인 연직진동해석)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.6 s.40
    • /
    • pp.55-66
    • /
    • 2004
  • Recently, many high-rise apartment buildings using the box system, composed of only reinforced concrete walls and slabs, have been constructed. In residential buildings such as apartments, vibrations occur from various sources and these vibrations transfer to neighboring residential units through walls and slabs. It is necessary to use a refined finite element model for an accurate vibration analysis of shear wall building structures. But it would take significant amount of computational time and memory if the entire building structure were subdivided into a finer mesh. Therefore, an efficient analytical method, which has only translational DOFs perpendicular to walls or slabs by the matrix condensation technique, is proposed in this study to obtain accurate results in significantly reduced computational time. If all of the DOFs except those perpendicular to walls or slabs in the shear wall structure eliminated using the matrix condensation technique at a time, the computational time for the matrix condensation would be significant. Thus, the modeling technique using super elements and substructuring technique is proposed to reduce the computational time for the matrix condensation. Dynamic analysis of 3-story and 5-story shear wall example structures were performed to verify the efficiency and accuracy of the proposed method. It was confirmed that the proposed method can provide the results with outstanding accuracy requiring significantly reduced computational time and memory.

A Study on the Application of Design Components of 3D Greenery System for Eco-Friendly Indoor and Outdoor Space of Buildings (건축물 내외부의 친환경 구성을 위한 입체녹화의 부문별 디자인 적용요소에 관한 연구)

  • Shin, Kyung-Sun;Kim, Won-Pil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.4
    • /
    • pp.275-284
    • /
    • 2017
  • As the 3D Greenery system is known to improve the urban environment, it works as new alternative for eco-friendly building and warrants further study for application to the domestic field. This study aimed to apply the design components for eco-friendly composition by investigating the spatial characteristics of the 3D Greenery System reflected in interior and exterior of buildings and to analyze the organization and design elements of domestic and foreign cases. The results showed that instances of the Greenery System tended to be a large scale and high-density development in order to expand various exterior spaces. Although its early forms were often found in such public facilities as exhibition and education purpose, cases of multi-unit dwelling have been growing. Allowing apartment residents to prefer intimate space by providing various such spaces for residential units and offering independent green spaces would induce diverse residents' lifestyles rather than monotonous design. The analysis also indicated that community space composed of various outdoor spaces and atmosphere would change life patterns of multi-housing and establish a real neighborhood through social interaction. Moreover, further investigation of the design patterns of outdoor space arrangement is needed since the Greenery system actively reflects the environmental characteristics of building sites and clearly shows a tendency to utilize natural terrain and slope in building shapes.

IEEE 802.11a Technnical Analysis and Research for Development of Unmanned Vehicle System (무인자동차 시스템 개발을 위한 IEEE 802.11a 기술 분석 및 연구)

  • Kim, Young-Hyuk;Choi, Sang-Wook;Lim, Il-Kwon;Choi, Jeong-Dan;Lee, Jae-Kwang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.108-111
    • /
    • 2009
  • In this paper, the development of unmanned vehicle systems to analysis applicable communications and alternative IEEE 802.11a. IEEE 802.11b/g uses the 2.4GHz. So, using the 5GHz OFDM in IEEE 802.11a interference phenomenon better. IEEE 802.11a has a maximum speed of 54Mbps. Indoors and apartment parking on experiment to soft roaming, hard roaming. Test equipments are AP four units(RSU), reliable results for the AP one unit Bridge, Switch one unit, one server notebook, one notebook(OBU), one car. Use Softwares are Wireshark, Jperf, Ping and million second transfer was used to develop the program. So the actual car was similar to the environment. With the results of the experiment for the unmanned vehicle systems will provide the best method.

  • PDF