• 제목/요약/키워드: Apartment Structures

검색결과 214건 처리시간 0.029초

축소실험실을 이용한 바닥완충구조의 경량충격음 차음성능 예측방법에 관한 실험적 연구 (An Experimental Study on the Prediction Method of Light Weight Floor Impact Sound Insulation Performance of Apartment Floor Structures through Mini-Laboratory Tests)

  • 송민정;장길수;김선우
    • 소음진동
    • /
    • 제10권1호
    • /
    • pp.82-96
    • /
    • 2000
  • The purpose of this study is to figure out the relationship between the mini-laboratory and the reverberation room for the domestic floor structures which are practically constructed in apartment houses. For this purpose, seven specimen which were varied in structures and thicknesses were tested in Chonnam National University reverberation room and in the artificial mini-laboratory which is the $\farc{1}{3}$ scale model of the former. From the result of this study, it was proved that there is a good correlation between the mini-laboratory and the reverberation room for the apartment floor structures as well as floorcovering PVC. The result of this study could save the labor and the time, etc.

  • PDF

국내 공동주택의 지진위험도 현황에 관한 연구 (The present state of earthquake hazard for the apartment structures in Korea)

  • 김현진;박태원;정란
    • 건설안전기술
    • /
    • 통권49호
    • /
    • pp.92-102
    • /
    • 2009
  • Earthquake is one of the hazard so hard because it is difficult predicted occurred time, scale and characters. Due to a recent Sichuan earthquake in China with a magnitude of 7.8, it is worried about having a major earthquake in Korea peninsula in near future. The earthquake in Kobe, Japan showed that the damages were concentrated on the buildings which were not considered to be protected from the earthquakes. In this study, apartment structures in Korea analyze about earthquake hazard and evaluate seismic performance. Through the this study we have notice of earthquake hazard for apartment structures which live a lot of population of Korea and suppose necessary for seismic retrofit.

  • PDF

국내 공동주택의 지진위험도 현황에 관한 연구 (The Present State of Earthquake Hazard for the Apartment Structures in Korea)

  • 김현진;박태원;정란
    • 한국안전학회지
    • /
    • 제23권6호
    • /
    • pp.100-107
    • /
    • 2008
  • Earthquake is one of the hazard so hard because it is difficult predicted occurred time, scale and characters. Due to a recent Sichuan earthquake in China with a magnitude of 7.8, it is worried about having a major earthquake in Korea peninsula in near future. The earthquake in Kobe, Japan showed that the damages were concentrated on the buildings which were not considered to be protected from the earthquakes. In this study, apartment structures in Korea analyze about earthquake hazard and evaluate seismic performance. Through the this study we have notice of earthquake hazard for apartment structures which live a lot of population of Korea and suppose necessary for seismic retrofit.

철근콘크리트 공동주택의 평면확장을 위한 연결부의 전단성능 평가에 관한 연구 (A Study on Shear Connector Performance Estimation for Plan Extension of RC Apartment Structures)

  • 김동백
    • 한국안전학회지
    • /
    • 제30권2호
    • /
    • pp.27-34
    • /
    • 2015
  • Nowadays, remodeling cases for some apartment like Hyundai through the support of government are reported. Conventionally, balcony and aisle are extended for additional private area or balcony which is supported by new frame is extended. In extension work at site, dowel bar is conventionally inserted in old concrete slab for connection with old and new slab, however, an examination for structural safety is rarely performed prior to construction, if ever, vertical load is only considered for structural analysis. When conventionally connected structures are exposed to earthquake, the old and new structures have individual earthquake behavior with different mode, which may lead the elimination of resistance to earthquake in new structures. As of this reason, new detailing connection system which can have light weight and sufficient ductility performance is developed for application to domestic extension works. Additionally, user manual and specification are also developed for fertilization of application for the developed technology.

공동주택 지하구조물의 누수 균열 진단 및 보수방법 표준 매뉴얼 - 유지관리 점검 - (Standard Manual for the Diagnosis and Repairing Leakage Cracks of Underground Structures in Apartment Housing - Maintenance Inspection -)

  • 김수연;이정훈;이승진;장덕배;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.343-344
    • /
    • 2018
  • This study proposes a standard method of diagnosis and repair to prevent and maintain the problem of durability deterioration caused by leakage cracks in apartment basement structures in Korea. Following the announcement of the previous maintenance plan section, this is the second part of the study, focusing on inspection of methods for diagnosing and repairing leakage cracks in apartment basement structures. In this thesis, the matters required for the procedures, types, times and equipment of the inspection plan and the inspection methods, records, and decisions required for the actual inspection are described.

  • PDF

기초지반강성을 고려한 벽식구조 아파트의 지진응답에 관한 연구 (Study on Seismic Response of Wall-Slab Apartment Building Sturucture Considering the Stiffnesses of a Foundation-Soil System)

  • 김지원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.167-175
    • /
    • 2000
  • Seismic analyses of structures can`t be performed without considering the effect of soil-structure interaction and seismic responses of a structure taking into account the stiffnesses of a foundation-soil system show a significant difference from those with a rigid base. However, current seismic analyses of apartment building structures were carried out assuming a rigid base and ignoring the characteristics of a foundation and the properties of the underlying soil. In this study, seismic analyses of apartment buildings of a particular wall-slab structural type were carried out comparing seismic response spectra of a flexible base with those of a rigid base and UBC-97. Wall-slab type low-rise or mid-height apartment buildings built on the deep soil layer showed a rigid body motion with the reduced seismic responses due to the base isolation effect, indicating that it is too safe but uneconomical to utilize the design spectra of UBC-97 for the seismic analysis of a wall-slab type apartment buildings due to the too conservative design.

  • PDF

공동 주택의 구조벽과 비내력벽의 일체화 효과에 따른 내진 성능 분석 (Seismic Evaluation of an Apartment House With a Coupling Effect of Structural and Non-Structural Walls)

  • 김은서;최병훈;이정한;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권3호
    • /
    • pp.85-92
    • /
    • 2019
  • This study was carried out to examine the effect of the presence of non-structural walls in apartment buildings subjected to an earthquake. It was believed that the presence of non-structural walls, which has not been considered in the structural design process, was usually built together with structural walls and this led to significant damages to the apartment buildings in Pohang earthquake, 2017. In this study, a 22-story apartment building was selected and modeled to simulate the seismic behavior due to earthquakes. The story drift, performance point, and compressive strain in the walls were the main parameters to evaluate the seismic performance with the presence of non-structural walls.

겨울철 난방시 탑상형 아파트 구조체의 축·방열 특성에 대한 현장측정 연구 (A Field Measurement Study on Heat Storage/Emission Characteristics of Tower Type Apartment Structures in Winter Season)

  • 장현재;조근제
    • 설비공학논문집
    • /
    • 제24권2호
    • /
    • pp.190-195
    • /
    • 2012
  • In this study, as a complementary study of the former study on indoor thermal environment in a tower type apartment house at tropical nights, a field measurement was conducted in winter season. Mainly, characteristics of heat storage and heat emission in apartment structures, in this study, were investigated. As results, indoor air temperature was changed in the range of $22.5^{\circ}C{\pm}1.0^{\circ}C$, and followed not the change of outdoor air temperature but the changed pattern of floor surface temperature. Wall surface temperature was unresponsive to the change of floor surface temperature compared with the change of indoor air temperature because wall structure was composed of concrete which has large heat capacity, and was changed in the range of $22.3^{\circ}C{\pm}0.6^{\circ}C$. Heat was stored continuously into the structures of wall and ceiling through the measurement term. and this means that a large heat capacity of the apartment structure acts as a disadvantage in winter season, too. As a total review of the study with the former study, a large heat capacity of the apartment structure acts against indoor thermal comfort in winter season as well as in summer season.

완충재의 종류에 따른 공동주택 바닥충격음 차단성능에 관한 실험연구 (An Experiment Study on Floor-Impact Sound Insulation by Resilient Materials in Apartment Buildings)

  • 윤세철;오종민
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.217-225
    • /
    • 2005
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among occupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for nine apartment buildings. The floor-impact sound levels were measured for twenty-five On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

공동주택 바닥충격음의 차음성능 평가 (Evaluation of Floor-Impact Sound Insulation for Apartment Buildings)

  • 윤세철;오종민
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.932-937
    • /
    • 2003
  • In apartment buildings, floor-impact sound has bean regarded as the major source which induces complaints from residents. It is mainly due to the use of light-weight structures. The vibration produced by impact on one part of an apartment building would travel as far as the other parts of structure with a little alleviation. As a result, the impact sound from upstairs has been regarded as a main source of noise causing discontentment among accupants. This study was carried out to measure the floor-impact sound levels and evaluate the insulation performance of floor-impact sound for seven apartment buildings. The floor-impact sound levels were measured for seventeen On-dol floor structures and various factors which influence the floor-impact sound were analyzed.

  • PDF