• Title/Summary/Keyword: Aortic valve exposure

Search Result 12, Processing Time 0.017 seconds

Clinical Experiences of Cardiac Surgery Using Minimal Incision (소절개선을 이용한 심장수술의 임상고찰)

  • Kim, Kwang-Ho;Kim, Joung-Taek;Lee, Seo-Won;Kim, Hae-Sook;Lim, Hyun-Kung;Lee, Choon-Soo;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.373-378
    • /
    • 1999
  • Background: Minimally invasive technique for various cardiac surgeries has become widely accepted since it has been proven to have distinct advantages for the patients. We describe here the results of our experiences of minimal incision in cardiac surgery. Material and Method: From February 1997 to November 1998, we successfully performed 31 cases of minimally invasive cardiac surgery. Male and female ratio was 17:14, and the patients age ranged from 1 to 75 years. A left parasternal incision was used in 9 patients with single vessel coronary heart disease. A direct coronary bypass grafting was done under the condition of the beating heart without cardiopulmonary bypass support(MIDCAB). Among these, one was a case of a reoperation 1 week after the first operation due to a kinked mammary artery graft. A right parasternal incision was used in one case of a redo mitral valve replacement. Mini-sternotomy was used in the remaining 21 patients. The procedures were mitral valve replacement and tricuspid annuloplasty in 6 patients, mitral valve replacement 5, double valve replacement 2, aortic valve replacement 1, removal of left atrial myxoma 1, closure of atrial septal defect 2, repair of ventricular septal defect 2, and primary closure of r ght ventricular stab wound 1. The initial 5 cases underwent a T-shaped mini-sternotomy, however, we adopted an arrow-shaped ministernotomy in the remaining cases because it provided better exposure of the aortic root and stability of the sternum after a sternal wiring. Result: The operation time, the cardiopulmonary bypass time, the aorta cross-clamping time, the mechanical ventilation time, the amount of chest tube drainage until POD#1, the chest tube indwelling time, and the duration of intensive care unit staying were in an acceptable range. There were two surgical mortalities. One was due to a rupture of the aorta cannulation site after double valve replacement on POD#1 in the mini-sternotomy case, and the other was due to a sudden ventricular arrhythmia after MIDCAB on POD#2 in the parasternal incision case. Postoperative complications were observed in 2 cases in which a cerebral embolism developed on POD#2 after a mini-sternotomy in mitral valve replacement and wound hematoma developed after a right parasternal incision in a single coronary bypass grafting. Neither mortality nor complication was directly related to the incision technique itself. Conclusion: Minimally invasive surgery using parasternal or mini-sternotomy incision can be used in cardiac surgeries since it is as safe as the standard full sternotomy incisions.

  • PDF

Anticoagulation Management after Mitral Valve Replacement with the St. Jude Medical Prosthesis (승모판치환 환자의 항응혈제 치료)

  • 김종환;김영태
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1172-1182
    • /
    • 1998
  • Background: Primary goal of anticoagulation treatment in patients with mechanical heart valve is the effective prevention of thromboembolism and safe avoidance of bleeding as well. Material and Method: Two-hundred and nine patients with the St. Jude Medical prosthesis operated on between 1984 and 1995, for mitral(MVR 122), aortic(AVR 39) and double mitral and aortic valve replacement(DVR 48) respectively, were studied on the practically achieved levels of anticoagulation and the clinical outcomes. Patients were on Coumadin and followed up by monthly visit to outpatient clinic for examination and prothrombin time measurement to adjust the International Normalized Ratios(INRs) within the low-intensity target range between 1.5 and 2.5. Result: A total anticoagulation follow-up period was 1082.0 patient- years(mean 62.1 months) and INRs of 10,205 measurements were available for evaluation. The accomplished INRs among the replacement groups were not significantly different and only 65% of INRs were within the target range. And, in individual patients, only 37% of patients had INRs included within the target range in more than 70% of tests during follow-up period. The levels of INRs in patients with atrial fibrillation, which was found in 57% of patients, were definitely higher than the ones measured in patients with regular rhythm(p<0.001). Thromboembolisms were experienced by 15 patients with the incidence of 1.265%/patient- year(MVR 1.412%, AVR 0.462% and DVR 1.531%/patient-year) and major bleeding by 4 patients with the incidence of 0.337%/patient-year(MVR 0.424%, AVR none and DVR 0.383%/patient-year). Frequent as well as prolonged missing of prothrombin time tests was the main risk factor strongly associated with the thromboembolic complications(odds ratio 1.99). The proportion of INRs within target range of less than 60% in individual patient was the highly significant risk factor of both thromboembolic and overall embolic and bleeding complications(p<0.004 and p<0.002 respectively). Conclusion: In conclusion, the low-intensity therapeutic target range of INRs was adequate in patients with AVR and in sinus rhythm. However, the patients with replacement of the mitral valve were more likely to require higher target range of INRs, especially in the presence of atrial fibrillation, to achieve the practical levels of anticoagulation enough to prevent thromboembolic complications effectively. For the higher therapeutic target range of INRs between 2.0∼3.0, further accumulation of clinical evidences are required. It is highly desirable to improve the patients' compliance under continuous instructions in visiting outpatient clinic and in taking daily Coumadin without omission and to keep INRs consistently within optimal range with tight control for minimization of chances and of periods of exposure to the risk of complications. And, particularly, patients with high risk of complications and with wide fluctuation of INRs should be better managed with frequent monitoring anticoagulation levels.

  • PDF