• Title/Summary/Keyword: Aortic valve disease

Search Result 197, Processing Time 0.021 seconds

Emergency Quadrido-Bentall Procedure for Aortic Rupture in a Patient with Behcet's Disease

  • Park, Sung Jun;Lee, Jeong-woo;Kim, Joon Bum
    • Journal of Chest Surgery
    • /
    • v.48 no.5
    • /
    • pp.364-367
    • /
    • 2015
  • Cardiovascular involvement in cases of Behcet's disease is a rare but life-threatening condition, and prosthetic valve detachment is a frequent and serious complication attributable to Behcet's disease following the surgical repair of aortic regurgitation. We report the case of a patient with Behcet's disease presenting with contained aortic rupture around the aortic root. The patient had previously undergone aortic valve surgery three times due to recurrent prosthetic valve detachment. An emergency operation was performed, consisting of aortic root replacement (ARR) using a composite valved conduit and the replacement of the hemiarch. ARR may be an appropriate surgical option for patients with Behcet's disease in order to prevent recurrence of the disease.

Aortic valve Replacement Concomitant with Aorto-Coronary Bypass Surgery -One case report- (관상동맥 우회술을 병행한 대동맥판막 치환술 치험 1례)

  • 정언섭
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.514-521
    • /
    • 1990
  • Patient with aortic valvular disease have increased left ventricular work and greater myocardial oxygen demand, which may aggravate the effect of concomitant coronary artery disease. Thus in patient who repair aortic valve replacement, concomitant aortocoronary bypass surgery is often performed when angiographically significant coronary artery disease is present. This approach is supported by reports that revascularization does not increase operative risk when associated coronary artery disease is present and significantly reduce the occurrence of late sudden death. Recently we have experienced one case of aortic valve replacement concomitant with aorta-coronary bypass surgery. The patient was 56 year-old male and admitted with complaint of anterior chest pain especially during his exercise. He was diagnosed as aortic valve stenosis and regurgitation [GIII] with proximal right main coronary artery occlusion We performed aortic valve replacement with aorta coronary bypass surgery by use of saphenous vein. Post operative course was uneventful and chest pain was relieved. Post operative coronary angiogram disclosed good patency of grafted vessel.

  • PDF

Comparable Outcomes of Bicuspid Aortic Valves for Rapid-Deployment Aortic Valve Replacement

  • Somin Im;Kyung Hwan Kim;Suk Ho Sohn;Yoonjin Kang;Ji Seong Kim;Jae Woong Choi
    • Journal of Chest Surgery
    • /
    • v.56 no.6
    • /
    • pp.435-444
    • /
    • 2023
  • Background: Edwards Intuity is recognized as a relatively contraindicated bioprosthesis for bicuspid aortic valve disease. This study compared the early echocardiographic and clinical outcomes of rapid-deployment aortic valve replacement for bicuspid versus tricuspid aortic valves. Methods: Of 278 patients who underwent rapid-deployment aortic valve replacement using Intuity at Seoul National University Hospital, 252 patients were enrolled after excluding those with pure aortic regurgitation, prosthetic valve failure, endocarditis, and quadricuspid valves. The bicuspid and tricuspid groups included 147 and 105 patients, respectively. Early outcomes and the incidence of paravalvular leak were compared between the groups. A subgroup analysis compared the outcomes for type 0 versus type 1 or 2 bicuspid valves. Results: The bicuspid group had more male and younger patients. Comorbidities, including diabetes mellitus, hypertension, chronic kidney disease, and coronary artery disease, were less prevalent in the bicuspid group. Early echocardiographic evaluations demonstrated that the incidence of ≥mild paravalvular leak did not differ significantly between the groups (5.5% vs. 1.0% in the bicuspid vs. tricuspid groups, p=0.09), and the early clinical outcomes were also comparable between the groups. In the subgroup analysis between type 0 and type 1 or 2 bicuspid valves, the incidence of mild or greater paravalvular leak (2.4% vs. 6.7% in type 0 vs. type 1 or 2, p=0.34) and clinical outcomes were comparable. Conclusion: Rapid-deployment aortic valve replacement for bicuspid aortic valves demonstrated comparable early echocardiographic and clinical outcomes to those for tricuspid aortic valves, and the outcomes were also satisfactory for type 0 bicuspid aortic valves.

Classificatin of Normal and Abnormal Heart Sounds Using Neural Network (뉴럴네트워크를 이용한 심음의 정상 비정상 분류)

  • Yoon, Hee-jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.5
    • /
    • pp.131-135
    • /
    • 2018
  • The heart disease taking the second place of the cause of the death of modern people is a terrible disease that makes sudden death without noticing. To judge the aortic valve disease of heart diseases a name of disease was diagnosed using psychological data provided from physioNet. Aortic valve is a valve of the area that blood is spilled from left ventricle to aorta. Aortic stenosis of heart troubles is a disease when the valve does not open appropriately in contracting the left ventricle to aorta due to narrowed aortic valve. In this paper, 3126 samples of cardiac sound data were used as an experiment data composed of 180 characteristics including normal people and aortic valve stenosis patients. To diagnose normal and aortic valve stenosis patients, NEWFM was utilized. By using an average method of weight as an feature selection method of NEWFM, the result shows 91.0871% accuracy.

Fibrocalcific Embolism of Right Coronary Artery Combined with Aortic Valvular Stenosis (대동맥판협착증에 동반된 우관상동맥의 석회성 색전증)

  • 장성욱;박정옥;김영권;이명용;류재욱;박성식;서필원;김삼현
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.858-861
    • /
    • 2003
  • The main cause of ischemic heart disease combined with aortic valve disease is the systemic atherosclerotic process. Coronary artery embolism by a particle from the calcified aortic valvular tissue is very rare. A 73-year-old female patient was admitted due to chest tightness of recent onset. Two dimensional echocardiogram showed severe calcific aortic valve stenosis. Preoperative coronary angiogram exhibited a stenotic lesion at the distal right coronary artery, which seemed to be embolic in origin. The coronary embolus was removed through the coronary arteriotomy and then the arteriotomy site was repaired by onlay patch angioplasty technique. Aortic valve was replaced by a bioprosthetic valve. The embolus was reported as a fibrocalcified particle of diseased valve.

Aortic valve replacement in the patient with rheumatic heart disease (류마치스성 심장질환 환자에서 대동맥판막치환)

  • An, Jae-Ho;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.17 no.3
    • /
    • pp.346-355
    • /
    • 1984
  • 77 cases of Aortic Valve Replacement, which were composed of 64 rheumatic valvular heart disease and 13 combined congenital heart disease, were operated at Seoul National University Hospital for Aortic valvular disease during the period from June 1968 to December 1983. Among these 64 rheumatic aortic valvular heart disease cases, 8 patients were expired during and immediate after operation and overall mortality rate was 12.5%. For more precise remarks, these patients were divided into two periodic groups, 1st period [from 1968 to 1976] and 2nd [from 1977 to 1983] when annual open heart surgery were over 100 cases, and in 1st period three of four patients were died and in 2nd period five of sixty patients were died and its mortality rate was 8.3%. There were 12 cases of postoperative complication, which were 3 cases of remaining other valvular heart disease required MVR, 2 paravalvular leaks [one of them got Redo AVR], 4 thromboembolism or problem of anticoagulant therapy, 2 late death due to SBE with replaced valve failure and one functional AS with small sized valve. Operative death was affected by pump-time and aortic cross-clamping time, heart size, Ejection Fraction, LVEDP and symptom duration, and other many factors may influence the survival rate. Improved operative technique and myocardial protection and meticulous evaluation of the preoperative patient status will make the AVR safer.

  • PDF

Aortic Valve Replacement Using Continuous Suture Technique in Patients with Aortic Valve Disease

  • Choi, Jong Bum;Kim, Jong Hun;Park, Hyun Kyu;Kim, Kyung Hwa;Kim, Min Ho;Kuh, Ja Hong;Jo, Jung Ku
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.249-255
    • /
    • 2013
  • Background: The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Materials and Methods: Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. Results: There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. Conclusion: The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

Cardiac Valve Replacement and Simultaneous Myocardial Revascularization (심장판막질환과 동반된 관상동맥질환의 수술)

  • Reiner, Korfer;Jee, Heng-Ok
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.164-168
    • /
    • 1988
  • Between November, 1984, and May, 1986, 93 patients underwent combined valvular and coronary artery operation. They were 70 male and 23 female, the age ranging from 29 to 82. From this population 89 patients underwent single valve replacement and 4 patients underwent double valve replacement. Patients with mitral valve disease were in the majority present in the age group between 50 till 70, where as in the group after 60 years, patients with aortic valve disease were dominant. The main indication for aortic valve replacement was aortic stenosis and the indication for mitral valve replacement was equal between mitral stenosis and mitral incompetence, the later was due to papillary dysfunction after myocardial infarction. Dyspnea was a very frequent symptom and it was found in nearly all patients. 28 patients had a previous myocardial infarction and severe left ventricular dysfunction. The grafts were placed prior to valve replacement and periods of myocardial ischemia were kept at a minimum by maintaining coronary perfusion throughout the operation. It is our opinion that simultaneous valve replacement and myocardial revascularization does not increase the risk of cardiac valve replacement substantially.

  • PDF

Assessment of the Severity of Degenerative Aortic Stenosis: Three Case Reports (퇴행성 대동맥판 협착증의 중증도 평가: 증례보고 3례)

  • Kim, Sung-Hee
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.270-275
    • /
    • 2019
  • The incidence of degenerative valve disease also increasing with the increasing life expectancy of the elderly population. Rheumatic valve disease is decreasing gradually and the incidence of calcified degenerative aortic stenosis (AS) is growing. Echocardiography is a very important tool for evaluating the prognosis and treatment method as well as the time of operation and diagnosis of heart valve disease. When evaluating valvular heart disease, 2-dimensional echocardiography, which observes all heart valves in detail, should take precedence. Understanding the clinical findings of degenerative valve disease and performing precise echocardiography are extremely important. In addition, an assessment of the severity of aortic stenosis is necessary to determine the surgical indications. An assessment of the severity by echocardiography was explained with three cases of degenerative aortic stenosis. To perform echocardiography accurately, it is necessary to understand degenerative valve disease and its clinical findings accurately.

Surgical Management of Aortic Insufficiency in Behcet's Disease (베체트씨병에 의한 대동맥판 폐쇄부전의 수술적 치료)

  • Kim, Kyung-Hwan;Kim, Ki-Bong;Kim, Won-Gon;Kim, Joo-Hyun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.33 no.5
    • /
    • pp.391-397
    • /
    • 2000
  • Background: Cardiac involvement of Behcets disease is very rate, however, the prognosis of Behcet disease depends on cardiovascular complications. In this article, we described surgical treatment of aortic insufficiency with Behcets disease. Material and Method: From March 1986 to February 1998, we operated on 10 patients of aortic insufficiency with Behcets disease. Male to female ratio was 8 to 2, and age ranged from 21 to 40 years(mean 32.8 years). There were 8 patients with evidence of Behcets disease and another 2 patients had some suspicious findings of Behcets disease(i.e., prosthetic value dehiscence, hypertrophied aortic wall). Adequate preoperative medical treatment for Behcets disease was done in 3 patients. Result: We performed 24 open heart surgeries in 10 patients. Redo value replacements using prosthetic valves were done in 4 patients. Among them, 2 patients were operated on for a second redo valve replacement and one of them operated on for a 4th and 5th operation because of recurrent paravalvular leakage. These 4 patients expired. 1 patient who had undergons tissue value replacement is alive. 1 patient who underwent Cabrol operation expired dut to rupture of graft anastomosis site. We used homografts in 3 patients. In 2 of them, we performed aortic root replacement and subcoronary valve replacement in another patient. The patient who underwent subcoronary valve insertion had remnant aortic insufficiency, so we are closely observing him. We also performed Ross operation in a 24 year old female who suffered severs aortic insufficiency and endocarditis after aortic valvuloplasty. 5 patients are alive and mean follow up duration is 49.0 months. Among them, we used homografts or sutografts in 4 patients. We could observe excellent clinical results in the patients who underwent aortic root replacement using homograft and they were treated medically for Behcets disease. Conclusion: We concluded that adequate preporative diagnosis, clinical suspicion, and periopertive medical treatment for Behcets disease are very important for the result of surgical management of aortic insufficiency with Behcets disease. The use of homograft or autograft was helpful for the healing of anastomosis site and we should carefully observe the long term follow up results.

  • PDF