• Title/Summary/Keyword: Aortic valve

Search Result 640, Processing Time 0.031 seconds

Ross Operation with Aortic Ring Annuloplasty (대동맥판륜 성형술을 동반한 Ross 술식)

  • 이재원;정성호;김건일;송명근
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.744-747
    • /
    • 2000
  • Pulmonic autograft replacement of the aortic valve(Ross procedure) has been to have potential for growth in children, no complication of antiocagulation, and enhanced durability. Therefore, Ross operation is indicated in the young, in patients with an active life style, and when anticoagulation is contraindicated. However, late autograft valve has occurrd more frequently in patients with significant size discrepancy between the pulmonay valve annulus and the aortic valve annulus. In order to resolve this problem, we performed aortic annuloplasty with Duran ring for more accurate and strong reinforcement. We report a case using the Duran ring as a method of aortic annuloplasty during Ross procedure.

  • PDF

Aortic Valve Replacement with Pulmonary Autograft in Patient with Congenital Aortic Stenosis : Ross Procedure without Homograft -one case report - (선천성 대동맥판 협착증에서 폐동맥판 자가이식편을 이용한 대동맥판 교체술:동종판막을 쓰지 않는 Ross술식)

  • 이은상;윤태진;서동만
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.303-306
    • /
    • 1999
  • This is a genuine case report of the Ross operation without the use of homografts or heterografts in reconstruction of the right ventricular outflow tract. A 8-year-old boy with congenital aortic stenosis underwent aortic valve replacement with a pulmonary autograft and right ventricular outflow tract reconstruction with a pericardial conduit bearing autologous aortic monocusp. The postoperative echocardiography and cardiac angiography revealed good ventricular function and competent neoaortic valve. He has been followed up for 19 months.

  • PDF

Fibrocalcific Embolism of Right Coronary Artery Combined with Aortic Valvular Stenosis (대동맥판협착증에 동반된 우관상동맥의 석회성 색전증)

  • 장성욱;박정옥;김영권;이명용;류재욱;박성식;서필원;김삼현
    • Journal of Chest Surgery
    • /
    • v.36 no.11
    • /
    • pp.858-861
    • /
    • 2003
  • The main cause of ischemic heart disease combined with aortic valve disease is the systemic atherosclerotic process. Coronary artery embolism by a particle from the calcified aortic valvular tissue is very rare. A 73-year-old female patient was admitted due to chest tightness of recent onset. Two dimensional echocardiogram showed severe calcific aortic valve stenosis. Preoperative coronary angiogram exhibited a stenotic lesion at the distal right coronary artery, which seemed to be embolic in origin. The coronary embolus was removed through the coronary arteriotomy and then the arteriotomy site was repaired by onlay patch angioplasty technique. Aortic valve was replaced by a bioprosthetic valve. The embolus was reported as a fibrocalcified particle of diseased valve.

Intravascular Hemolysis after Prosthetic Valve Replacement (인공판막 치환수술후의 용혈)

  • Jang, Won-Chae;Lee, Gye-Yeong;Kim, Sang-Hyeong
    • Journal of Chest Surgery
    • /
    • v.25 no.12
    • /
    • pp.1556-1562
    • /
    • 1992
  • Forty two consecutive patients who had had valve replacement with St. Jude Medical prosthesis were studied on a view point of intravascular hemolysis. Patients were consisted of 14 mitral valve replacement, and 7 aortic valve replacement, and 21 double, mitral and aortic, valve replacement. Serum LDH, indirect bilirubin, GOT, hemoglobin levels and ret-iculocyte count were pursued in postopeative 1st day, 3rd day, 7th day, 14th day and 21th day. Postoperatively, all patients were not detected paravalvular leakage on the ech-ocardiographical study. The patients with double valve replacement revealed higher levels of LDH on postopeative 14th day[P<0 05] than those with single valve replacement. Among the patients with single valve replacement, the patients with aortic valve replacement revealed slightly higher levels of entire postopeative data, but considered insignificant. There was correlation between the severity of hemolysis and the size of replaced aortic valve. In the postoperative LDH levels, the patients with small sized-aortic valve[less than 21mm in diameter] replacement revealed higher levels of postoperative 3rd day, 7th day and 14th day than those with large size[more than 23mm in diameter]. The patients with high level LDH of greater than 800 WU /L on postoperative 7th day were 61.9%[26 of 42]. The high LDH frequency of DVR was 71.4%[15 of 21], MVR 50.0%[7 of 14] and AVR, 57.1%[4 of 7]. The level of LDH declined gradualiy thereafter through postoperative 3 weeks. In conclusion, intravascular hemolysis after prosthetic valve replacement was dependent on position of valve replacement and size of valve. And this study supports the conventional valve selection and usage in our hospital. The patients with subclinical hemolysis after valve replacement should be placed on a close observation.

  • PDF

Congenital Quadricuspid Semilunar Valve - A case report - (선천성 사엽성 반월형 판막 - 1예 보고 -)

  • Seo, Min-Bum;Seo, Hong-Joo
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.361-363
    • /
    • 2009
  • A 17-year-old male patient was referred with symptoms of dyspnea. Multi-detector computerized tomography (MDCT) and echocardiography evaluation revealed quadricuspid aortic and pulmonary valves, an atrial septal defect (ASD), and pulmonary stenosis. We closed the ASD using a bovine patch and performed a commissurotomy of the pulmonary valve. Quadricuspid semilunar valves are very rare congenital abnormalities that are reported to occur nine times more frequently in the pulmonic valve than in the aortic valve. According to the Hurwitz Roberts classification, the aortic valve was type A, and the pulmonic valve was type B. The aortic valve normal function, but the pulmonic valve was stenotic and had abnormal function.

Prognosis of Unrepaired Ascending Aorta after the Surgical Replacement of Bicuspid Aortic Valves

  • Hong Ju Shin;Wan Kee Kim;Dong Kyu Kim;Ho Jin Kim;Joon Bum Kim
    • Journal of Chest Surgery
    • /
    • v.56 no.4
    • /
    • pp.255-261
    • /
    • 2023
  • Background: The surgical threshold for bicuspid aortic valve (BAV)-related aortopathy is a matter of debate due to its uncertain etiology and prognosis. This study investigated the prognosis of unrepaired BAV aortopathy in patients undergoing surgical aortic valve replacement (SAVR). Methods: We retrospectively analyzed data from 720 patients (age, 60.8±11.5 years; 246 women) who underwent SAVR for BAV disease without aortic repair between 2005 and 2020 at Asan Medical Center. The clinical endpoints were defined as occurrences of sudden death, aortic dissection or rupture, and elective aortic repair. To estimate postoperative changes in the dimensions of the unrepaired aorta, the individual annual aortic expansion rate was calculated. Multiple linear regression models were used to evaluate the risk of aortic expansion. Results: The mean ascending aortic diameter was 39.5±4.6 mm, and 299 patients (41.5%) had a baseline ascending aorta diameter >40 mm. During 70.0±68.3 months of follow-up, the mean annual aortic expansion rate was 0.39±1.96 mm/yr, no aortic dissection or rupture was observed, and sudden deaths were reported in 12 patients (0.34% per person-year). Linear regression analysis revealed no significant correlation between the baseline ascending aortic diameter and postoperative aortic expansion (R2=0.004, β=-0.84, p=0.082). Conclusion: In selected patients undergoing SAVR for a BAV (<55 mm), the risk of adverse aortic events was very low. As this observation contradicts current practice guidelines advocating for proactive aortic replacement in dilated ascending aortas measuring >45 mm, the study results need further validation by studies involving larger populations or randomized controlled trials.

Bronchial Artery Embolization of Massive Hemoptysis -2 cases- (대량 객혈에 대한 기관지동맥 색전술 -치험 2례-)

  • 강경훈
    • Journal of Chest Surgery
    • /
    • v.21 no.6
    • /
    • pp.1117-1123
    • /
    • 1988
  • Prolapse of the aortic valve is the main cause of insufficiency of the aortic valve as a complication of ventricular septal defect. Aortic insufficiency gets worse by the progress of prolapse of aortic valve due to lack of support of the valve and the hemodynamic effect of blood flow through the ventricular septal defect. This produces typical clinical picture, that may be serious and threatening when it is untreated. Type and timing for the surgical treatment of the ventricular septal defect with aortic insufficiency is considered. Among 113 ventricular septal defect, 9 patients of ventricular septal defect with associated aortic insufficiency were experienced from June. 1983 to June 1988 at the Department of Thoracic and Cardiovascular Surgery, Chon-Buk University Hospital. Male was 6 patients and female was 3 patients. Ages were from 7 years to 24years. 5 patients were from 10 to 19 years age. 3 patients were below 10 years age. The ratio of pulmonary blood flow to systemic f low [Qp/Qs] was 1.53 and in pulmonary vascular resistance, normal or slight increase was 7 patients, moderate 1 patient, and severe 1 patient. Ventricular septal defect was subpulmonic in 5 patients and infracristal in 4 patients. Prolapse of right coronary cusp was 7 patients, right and non coronary cusp 1 patient and non coronary cusp 1 patient. Teflon patch closure of ventricular septal defect was undertaken in 3 patients and primary closure in 1 patient. Among the 4 patients of defect closure alone, one patient performed valve replacement 7 months later due to progressive regurgitation and cardiac failure and the result was good. The other 3 patients were good result. Closure of ventricular septal defect and aortic valvuloplasty performed in 4 patients. 2 patients of these required valve replacement for the sudden intractable cardiac failure and died due to low cardiac output. The cause of intractable cardiac failure was tearing of repaired valve at the fixed site. The other 2 patients were good result. Closure of ventricular septal defect and valve replacement performed in 1 patient with good result.

  • PDF

Classificatin of Normal and Abnormal Heart Sounds Using Neural Network (뉴럴네트워크를 이용한 심음의 정상 비정상 분류)

  • Yoon, Hee-jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.5
    • /
    • pp.131-135
    • /
    • 2018
  • The heart disease taking the second place of the cause of the death of modern people is a terrible disease that makes sudden death without noticing. To judge the aortic valve disease of heart diseases a name of disease was diagnosed using psychological data provided from physioNet. Aortic valve is a valve of the area that blood is spilled from left ventricle to aorta. Aortic stenosis of heart troubles is a disease when the valve does not open appropriately in contracting the left ventricle to aorta due to narrowed aortic valve. In this paper, 3126 samples of cardiac sound data were used as an experiment data composed of 180 characteristics including normal people and aortic valve stenosis patients. To diagnose normal and aortic valve stenosis patients, NEWFM was utilized. By using an average method of weight as an feature selection method of NEWFM, the result shows 91.0871% accuracy.

A Successful Replacement of Ascending Aorta and Aortic Valve With a composite Graft (대동맥판막 및 상행대동맥 대치이식술 1례 - Bentall씨 수술 변형술 -)

  • 조경수
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.693-697
    • /
    • 1989
  • A forty-eight-year-old female patient with ascending aortic aneurysm with aortic insufficiency underwent a modified Bentall operation. The ascending aorta and the aortic valve were replaced with a composite graft containing a St. Jude valve. The coronary orifices were anastomosed to the tubular Dacron prosthesis by means of a second smaller Gore-Tex tube, and a fistula between the aneurysmal sac and the right atrial appendage was created to drain oozing from the prosthesis. The postoperative course was uneventful and the patient was discharged without complication. She is doing well on the 14 months follow-up.

  • PDF

Avulsion of Aortic Commissure: Rare Cause of Aortic Regurgitation - 2 case reports - (교련부 분리에 의해 발생한 대동맥판 역류 - 치험 2예 -)

  • Choi, Jae-Woong;Hwang, Ho-Young;Choi, Eun-Suk;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.42 no.6
    • /
    • pp.777-780
    • /
    • 2009
  • We reported here on 2 cases of aortic regurgitation (AR) that were due to avulsion of the aortic valve commissure. Aortic valvuloplasty was attempted in both cases. In the 1st case, valvuloplasty was performed with reattaching the commissure using the 5-0 polypropylene continuous suture technique. However, aortic regurgitation recurred and this lead to reoperation on the postoperative $14^{th}$ day. The intraoperative finding revealed a completely re-detached commissure that required mechanical valve replacement. In the second case, we attempted to reattach the commissure using pledgetted multiple transverse mattress sutures with 5-0 polypropylene. Because the leaflet coaptation was incomplete, the aortic valve was replaced with a tissue valve.