• Title/Summary/Keyword: Aortic valve, stenosis

Search Result 128, Processing Time 0.036 seconds

Subvalvular Septal Myectomy and Enlargement of the Narrow Aortic Root in Patients with Aortic Valve Replacement

  • Schulte, H.D.;Birchs, W;Horstkotte, D;Kim, Y.H.;Kerstholt, J;Preusse, C.J.;Winter, J
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.220-224
    • /
    • 1989
  • In candidates for aortic valve replacement [AVR]it is our primary intention to implant the largest possible vale prosthesis of at least 23 mm in diameter in patients with severe valvular aortic stenosis. However, in many patients there is an additional subvalvular asymmetric septal hypertrophy which in some cases may cause an postextrasystolic increase of the LV-aortic gradient. Another component of the aortic stenosis syndrome is a narrow valvular ring, or a combination of both. After complete removal of the diseased valve and decalcification the narrow aortic ring [< 23 mm] can be widened firstly by transaortic subvalvular septal myectomy- [TSM] thus unfolding the left ventricular outflow tract[LVOT]and secondly by extending the oblique aortic incision into the aortic valve ring or further down into the anterior leaflet of the mitral valve. The sub-and supra-valvular defect will be closed by patch enlargement of the aortic root [PEAR] using autologous pericardium. These techniques allow a considerable enlargement of the valvular ring of about 4 to 10 mm in circumference. In a retrospective study using a computerized program, 847 patients with AVR [1980-1984]were reviewed to evaluate the intraoperative hemodynamic results mainly concerning relief of the transvalvular gradient. In 626 patients AVR was performed, 151 patients had double valve replacement [AVR+MVR], and 70 patients had AVR plus additional surgical procedures. Concentrating on the AVR-group [n=626] there were 103 patients with TSM, 24 patients with PEAR and 20 patients with TSM+PEAR which demonstrated that in a total, of 147 patients of this groups [23.5%] an additional procedure was necessary. The Statistical evaluation of the intraoperative pressure measurements before and after AVR in relation to the size of the implanted prostheses indicated the lowest preoperative mean gradient in patients with AVR alone, the highest in patients who afforded TSM plus PEAR. However, after AVR the mean gradients in all three groups were very low [mean 5 to 10 mmHg]. These data indicate that in patients with a narrow aortic ring and additional considerable ASH, TSM and PEAR are suitable techniques to enlarge the aortic root to enable the implantation of an adequate aortic valve prosthesis. Long-term controls have shown that autologous pericardium is a qualified graft material for the ascending aorta.

  • PDF

Transcatheter Mitral Valve Implantation in Open Heart Surgery: An Off-Label Technique

  • Alfonsi, Jacopo;Murana, Giacomo;Corsini, Anna;Savini, Carlo;Di Bartolomeo, Roberto;Pacini, Davide
    • Journal of Chest Surgery
    • /
    • v.50 no.6
    • /
    • pp.467-470
    • /
    • 2017
  • Extensive mitral annulus calcifications are considered a contraindication for valve surgery. We describe the case of a 76-year-old female with severe mitral and aortic stenosis associated with extensive calcifications of the heart. The patient underwent an open mitroaortic valve replacement using transcatheter aortic valve implantation with an Edwards SAPIEN XT valve (Edwards Lifesciences Corp., Irvine, CA, USA) in the mitral position. The aortic valve was replaced using a stentless valve prosthesis (LivaNova S OLO; LivaNova PLC, London, UK). Postoperative echocardiography showed that the prosthetic valve was in the correct position and there were no paravalvular leaks. A bailout open transcatheter valve implantation can be considered a safe and effective option in selected cases with an extensively calcified mitral valve.

Cardiac Surgery : A report of 1640 cases (심장질환의 외과적 치료 -1640 수술예 보고-)

  • 이영균
    • Journal of Chest Surgery
    • /
    • v.13 no.2
    • /
    • pp.92-99
    • /
    • 1980
  • From 1958 up to the end of April 1980, during the period of 12 years 1640 cardiac surgery cases including 1069 open heart surgery and 304 valve replacement cases, were operated in this Department. There were 1070 congenital anomaly and 570 acquired disease cases. In 1070 congenital anomaly cases 673 acyanotic and 397 cyanotic anomaly patients were noted. In acquired diseases 94 pericardial and 456 valvular cases were found. Among 456 valve cases 189 mitral stenosis, 133 mitral insufficiency, 30 aortic valve lesion, 97 double valve, and 7 triple valve lesion patients were noted. Among 304 valve replacement cases 209 mitral, 34 aortic, 5 tricuspid, 34 aortic with mitral, 20 mitral with tricuspid, and 2 triple valves were replaced. Annual increase `of open heart surgery cases and decrease of operative deaths were remarkable in recent years. In recent years Shiley** oxygenator in pump-oxygenator set up and Ionescu** bovine pericardial xenograft bioprosthesis were used for valve replacement mainly.

  • PDF

Coronary Arteriovenous Fistula Associated with Aortic Stenosis and Regurgitation -Report of a Case (대동맥판협착 및 폐쇄부전증을 동반한 관상동정맥루 -1례 치험-)

  • 조창훈
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1133-1137
    • /
    • 1991
  • Congenital coronary arteriovenous fistula is relatively uncommon and often associated with additional congenital and acquired heart disease. If coronary arteriovenous fistula is suspected, the diagnosis can be made readily by cardiac catheterization and selective coronary arteriography. Surgical treatment is very satisfactory, with a low mortality and apparent good long term result. Recently, we experienced one case of congenital coronary arteriovenous fistula which was associated with aortic stenosis and regurgitation. The tortuous fistula tract was noted between the left anterior descending coronary artery and the main pulmonary artery. Under the cardiopulmonary bypass, aortic valve replacement[Carbomedics 23mm] and suture closure of the draining orifice of coronary arteriovenous fistula in the main pulmonary artery just above the pulmonary valve were performed, Postoperative hospital course was uneventful and the patient was discharged postoperative 9th day without any problems.

  • PDF

Congenital Aortic Stenosis: Report of 2 Cases (선천성 대동맥 판막 협착증 치험 2예)

  • 송명근
    • Journal of Chest Surgery
    • /
    • v.11 no.2
    • /
    • pp.194-198
    • /
    • 1978
  • Congenital aortic stenosis, a relatively uncommon congenital heart disease, may cause heart failure and may be fatal. In recent years, increased clinical awareness and improved diagnostic and operative technique has made accurate diagnosis and successful treatment possible. Recently we experienced 2 cases of congenital aortic stenosis, and which was corrected surgically. The first case was 9 years old boy, and second case was 16 years male. Preoperative diagnosis was entertained by angiography and cardiac catheterization in both cases. In each case, aortic valve opening was widened by incision along the fused commissure between the combined left and right coronary cusp on one side, and the noncoronary cusp on the other side. Post-op. pressure gradient between the aorta and left ventricle markedly reduced, in the first case, 50mmHg, and in the 2nd case, 55mmHg.Both patients discharged with good results 2 weeks after open heart surgery.

  • PDF

Successful emergency transcatheter aortic valve implantation

  • Lee, Jung-Hee;Ji, Ah-Young;Kim, Young Ju;Song, Changho;Jin, Moo-Nyun;Kim, Sun Wook;Hong, Myeong-Ki;Hong, Geu-Ru
    • Journal of Yeungnam Medical Science
    • /
    • v.31 no.2
    • /
    • pp.144-147
    • /
    • 2014
  • Despite the necessity of surgical aortic valve replacement, many patients with symptomatic severe aortic stenosis (AS) cannot undergo surgery because of their severe comorbidities. In these high-risk patients, percutaneous transcatheter aortic valve implantation (TAVI) can be safely accomplished. However, no study has shown that TAVI can be performed for patients with severe AS accompanied by acute decompensated heart failure. In this case report, 1 patient presented a case of severe pulmonary hypertension with decompensated heart failure after diagnosis with severe AS, and was successfully treated via emergency TAVI. Without any invasive treatment, acute decompensated heart failure with severe pulmonary hypertension is common in patients with severe AS, and it can increase mortality rates. In conclusion, TAVI can be considered one of the treatment options for severe as presented as acute decompensated heart failure patients with pulmonary hypertension.

Midterm results of aortic root enlargement with AVR in patients with narrow aortic root and AS (협소 대동맥 판륜을 가진 환자에서의 대동맥치환술시 판륜 확장술의 중기 성적)

  • 박광훈;김하늘루;최강주;이양행;황윤호;조광현
    • Journal of Chest Surgery
    • /
    • v.33 no.4
    • /
    • pp.285-289
    • /
    • 2000
  • Background: For AVR using conventional prosthetic valves in adult patients with a narrow aortic root, aortic root enlargement is necessary to reduce postoperative pressure gradient across the aortic valve (ΔP). An evaluation of early and mid-term results of aortic root enlargement with AVR and echocardiographic follow up of ΔP and left ventricular function was performed. Method: From Aug. 1991 to Feb. 1998, eighteen patients aged 17 to 59 years(mean, 38$\pm$12 years) underwent Manouguian procedure with AVR. Aortic annular circumstance was enlarged 10.0mm to 18.0mm(mean, 12.6$\pm$6.3mm). Eight patients(44.0%) had NYHA class III status before operation, and seven cases of them underwent concomitant MVR. Valve pathology was ASr in 6 cases, AS in 4 cases, nd ASr+MSr in 8 cases. Replaced valve size was 21mm in 8 cases and 23 mm in 10 cases, and St. Jude Medical mechanical valve was used in 10 cases and Carbomedics in 8 cases. Result: Follow-up duration was 6 to 57 months (mean, 26$\pm$18 months), and total follow-up was 287 patient-year. There were one hospital death and one late death, therefore, actuarial survival rate was 85.7% at 56 months. Peak ΔP wad decreased significantly at postoperative mid-term period as 13$\pm$5mmHg, compared with thepreoperative one (42$\pm$8mmHg) (p<0.01). LVM(gm/$m^2$) was also diminished as 35.8%(115$\pm$36gm/$m^2$)at postoperative mid-term period, compared with preoperative one (179$\pm$56gm/$m^2$)(p<0.05). Conclusion: There were no specific complications related to the procedure. And we could have adequate enlargement of aortic annulus to suitable prosthetic valve that have no effect of patient-prosthese mismatch.

  • PDF

Surgical correction of congenital aortic stenosis - Report of 14 cases - (선천성 대동맥협착증 수술치험 14례 보)

  • 조범구
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.710-714
    • /
    • 1987
  • Over the past 6 years, from July, 1981. through June, 1987., 14 consecutive patient with congenital aortic stenosis underwent corrective surgery in our department of Thoracic and Cardiovascular Surgery. The patient ranged in age from 1 to 20 years. There were 8 male and 6 female patients. According to the operative findings, stenotic site was valvular stenosis [5 cases], subvalvular stenosis [5 cases], supravalvular stenosis [2 cases], valvular and supra valvular stenosis [1 case]. We have performed valvotomy and commissurotomy [5 cases]. Resection of subvalvular membrane [3 cases], patch enlargement of Ascending aorta [2 cases], LV myotomy [2 cases], valvotomy and excision of membrane [1 case], patch enlargement of ascending aorta and valve ring [1 case]. There was one hospital mortality [7.1%]. He died of C-I bleeding and sepsis on the 25th postoperative day. All survivors showed improvement in NYHA functional class in the 160 patient/month follow up period.

  • PDF

Clinical Study of Multiple Cardiac Valve Replacement : A Report of 63 Cases (중복심장판막이식의 임상적 고찰 63예 보고)

  • Suh, Kyung-Pill;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.405-413
    • /
    • 1980
  • A total of 63 patients [42 males and 21 females] underwent multiple valve replacement with artificial valves between January 1975 and August 1980 at Seoul National University Hospital. There were 38 patients with aortic and mitral valve replacement, 22 with mitral and tricuspid, and 3 with aortic, mitral and tricuspid valve replacement. The valve lesions varied from trivial to severe and most aortic and mitral valves had mixed stenosis and insufficiency, while tricuspid valves had only insufficiency. The patients were severely symptomatic in majority of the cases, and belonged to the Classes III and IV [III:45, IV:16] of the NYHA functional criteria. Hemodynamic studies were performed on all the patients. The mean pulmonary wedge pressure was remarkably increased to 19.8 mmHg in aortic and mitral valve lesions and 18.0 mmHg in mitral and tricuspid valve lesions. The mean pulmonary arterial pressure was also increased, while the cardiac index was reduced. In 1977, the average perfusion time was 245.5 minutes for aortic and mitral valve replacement and 181.6 minutes for mitral and tricuspid valve replacement. It has progressively declined to 169.2 minutes for aortic and mitral valve replacement and 123 minutes for mitral and tricuspid valve replacement in 1980. The average period of aortic occlusion also declined after the use of cardioplegic solution. Twenty deaths occurred among the 63 patients operated upon, an overall mortality rate of 30.8%. The operative mortality has declined with successive year from a level of 66.7% before 1977 to 21.1% in 1980. Fourteen patients suffered from a list of postoperative complications, which eventually resolved with adequate treatment. All the survivors were enjoying the levels of daily life activities greater than those existing before the operation.

  • PDF

Aortic Root Reimplantation in a Patient Who Underwent an Arterial Switch Operation

  • Kwon, Young Kern;Kang, Seung Ri;Park, Sung Jun;Kim, Wan Kee;Kim, Joon Bum
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.395-398
    • /
    • 2018
  • Neo-aortic insufficiency associated with root enlargement following an arterial switch operation is a serious late complication. To achieve successful surgical correction of this condition, multiple factors should be considered, including the individual patient's anatomy, the challenging nature of the redo procedure, and the patient's young age. However, limited publications have described the use of valve-sparing techniques for the treatment of neo-aortic insufficiency associated with root enlargement following an arterial switch operation. Herein, we report our recent experience of a valve-sparing aortic root procedure with ascending aorta and hemiarch replacement despite the presence of a discrepancy in leaflet size and nearby severe adhesions.