Use of the Native Aortic Valve as the Pulmonary Valve in the Ross Procedure (Ross 술식에서 자가대동맥판막을 이용한 우심실유출로 재건술)

  • 나찬영;이영탁;김수철;오삼세;김욱성;정철현;정도현;김웅한;이창하
    • Journal of Chest Surgery
    • /
    • v.31 no.12
    • /
    • pp.1222-1225
    • /
    • 1998
  • Aortic valve replacement in young patients has its problems. Biologic prosthetic valves degenerate and need replacement. Metalic prosthetic valves are more durable, however, anticoagulation which has its inherent problems is inevitable. The use of Ross procedure in young patients is gaining wider acceptance. The need of foreign pulmonary valve in right ventricular outflow tract(RVOT) will require reoperation due to RVOT obstruction, later. To overcome this problem, we reimplanted the native aortic valve in the pulmonary position in 21 year old female patient operated on utilizing the Ross procedure for aortic insufficiency. We experienced that the diseased aortic valve worked well in the pulmoanry position because of low pulmonary artery pressure and resistance.

  • PDF

Clinical Analysis of Bileaflet Mechanical Valve Replacement (Bileaflet Mechanical Valve의 임상적 고찰)

  • Kim, Mun-Hwan;Jin, Seong-Hun
    • Journal of Chest Surgery
    • /
    • v.26 no.9
    • /
    • pp.677-685
    • /
    • 1993
  • Experience with bileaflet mechanical valve replacement at the Inha Hospital in 192 patients, operated on from June 1986 until April 1993. Two hundred fourty-one prostheses [51 Duromedics, 79 St.Jude Medical, and 111 CafboMedics]were implanted during the total 195 operations. Mitral valve replacment[MVR]was done in 113 cases, aortic valve replacement[AVR]in 34, tricuspid valve replacement[TVR]in 2, and double valve replacement[DVR]in 46 cases.Of the total patients, 63.0% were women and 37.0% were men. The mean age of the patients was 40.8 years, ranged from 14 to 67years. Overall early mortality was 9.2\ulcorner%[18 out of 195]; 9.7%[11 out of 113]for MVR, 14,7% [5 out of 34]for AVR, and 4.3%[2 out of 46]for DVR. All of the operative survors were followed over a period of one to 83 months with a mean of 37 months, for total 543 patient-years. So far, eleven patients[6.7% of the long-term survivors]were lost to follov-up after a mean postoperative follow-up of 22.8 months. There were nine late deaths; three deaths due to prostetic valve endocarditis, two due to persistent heart failure, one due to cerebral hemorrhage, one due to aortic dissection after Bentall oreration, and two sudden deaths. Actuarial survival rate at 6.9 years was 94.8%, There were seventeen valve-related complications; three prosthetic valve thromboses, three thrombembolisms, three instances of prosthetic valve endocarditis, two paravalvular leakages, and six hemorrhagic complications related to anticoagulation. The actuarial rate of freedom from all valve-related complications at 6.9years was 91.3%. There were significant decreases in the heart size postoperatively that can be demonstrated by comparison of cardio-thoracic ratios on simple chest X-ray and left ventricle dimensions on echocardiography. We conclude that this midterm follow-up shows good results in terms of hemodynamics and durability although further long-term evaluations are mandatory.

  • PDF

transprosthetic Pressure Gradient after aortic Valve Replacement with Small Sized Prostheses (작은 기계 판막을 이용한 대도액 판막 치환술 후 판막 전후 압력차)

  • Hwang, Kyung-Hwan;Park, Kay-Hyun;Cha, Dae-Won;Jun, Tae-Gook;Park, Pyo-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.33 no.2
    • /
    • pp.146-150
    • /
    • 2000
  • background: The prognosis after an aortic valve replacment can be affected significantly by the transprosthetic pressure gradient which is determined mainly by the size of the patients body and the prosthesis used. We analyzed the hemodynamic feature of two relatively new prosthese the ATS and the evensized Medtronic-Hall(M-H) valves by measuring the transprosthetic pressure gradient in the cases where small sizes (23mm or smaller) were used. Material and method: There were 94 patients who received whom aortic valve replacement with prosthesis smaller than 23 mm from October 1994 to June 1998. In these patients the transprosthetic pressure gradient clalculated from the pressure half time during postoperative Dopper echocardiographic examination was compared between the prostheses of different sizes. The body surface area of each patient was also taken into consideration. result: The mean pressure gradient and body surface area in each group were 21.7$\pm$10.2 mmHg and 1.52$\pm$0.14m2 in ATS 19mm 11.4$\pm$6.5 mmHg and 1,57$\pm$0.20m2 in M-H 20mm 15.2$\pm$6.3 mmHg and 1.54$\pm$0.13m2 in ATS 21mm 9.3$\pm$2.5 mmHg and 1.63 $\pm$0.14m2 in M-H 22 mm and 12.9$\pm$5.3 mmHg and 1.69$\pm$0.13m2 in ATS 23mm. Conclusion: The 19mm ATS prosthesis showed significant trasprosthetic pressure gradient which is similar to the values previously reported with other bileaflet prosthesesm Close follow-up was needed in terms of exercise capacity and change in left ventiricular geometry. In patients with small aortic valve annulus the 20mm M-H valve is recomendable as an alternative to 19mm bileaflet valves because it has less pressure gradient with similar outer diameter.