• Title/Summary/Keyword: Aortic valve, repair

Search Result 107, Processing Time 0.025 seconds

Outcomes of Combined Mitral Valve Repair and Aortic Valve Replacement (대동맥판막 치환술과 동반시행한 승모판막 성형술 결과)

  • Baek, Man-Jong;Na, Chan-Young;Oh, Sam-Se;Kim, Woong-Han;Whang, Sung-Wook;Lee, Cheol;Chang, Yun-Hee;Jo, Won-Min;Kim, Jae-Hyun;Seo, Hong-Ju;Kim, Soo-Cheol;Lim, Cheong;Kim, Wook-Sung;Lee, Young-Tak;Choi, Hyun-Seok;Moon, Hyun-Soo;Park, Young-Kwan;Kim, Chong-Whan
    • Journal of Chest Surgery
    • /
    • v.36 no.7
    • /
    • pp.463-471
    • /
    • 2003
  • The long-term results of combined mitral valve repair and aortic valve replacement (AVR) have not been well evaluated. This study was performed to investigate the early and long-term results of mitral valve repair with AVR. Material and Method: We retrospectively reviewed 45 patients who underwent mitral valve repair and AVR between September 1990 and April 2002. The average age was 47 years: 28 were men and 17 women. Twelve patients had atrial fibrillation and three had a previous cardiac operation. The mitral valve disease consisted of pure insufficiency (MR) in 34 patients, mitral stenosis (MS) in 3, and mixed lesion in 8. Mitral valve disease was due to rheumatic origin in 24 patients, degenerative in 11, annular dilatation in 8, and ischemia or endocarditis in 2. The functional anatomy of mitral valve was annular dilatation in 31 patients, chordal elongation in 19, leaflet thickening in 19, commissural fusion in 13, chordal fusion in 10, chordal rupture in 6, and so on. Aortic prostheses used included mechanical valve in 32 patients, tissue valve in 12, and pulmonary autograft in one. The techniques of mitral valve repair included annuloplasty in 32 patients and various valvuloplasty of 54 techniques in 29 patients. Total cardiopulmonary bypass and aortic cross clamp time were 204$\pm$62 minute and 153$\pm$57 minutes, respectively. Result: Early death was in one patient due to low output syndrome (2.2%). After follow up of 57$\pm$37 months, late death was in one patient and the actuarial survival at 10 years was 96$\pm$4%. Recurrent MR developed grade II or III in 11 patients and moderate MS in 3. Three patients required reoperation for valve-related complications. The actuarial freedom from recurrent MR, MS, and reoperation were 64$\pm$11%, 86$\pm$8%, and 89$\pm$7% respectively. Conclusion: Combined mitral valve repair with AVR offers good early and long-term survival, and adequate techniques and selection of indication of mitral valve repair, especially in rheumatic disease, are prerequisites for better long-term results.

Surgical Treatment for Multivalvular Heart Disease (중복 심장판막 질환의 외과적 치료)

  • Kim, Jin; Jo, Jung-Ku;Kim, Kong-Soo
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.875-882
    • /
    • 1996
  • Multlvalvular heart surgery was performed In 78 cases, in the Department of Thoracic & Cardiovascu far Surgery of Chonbuk national University Hospital from november 1983 to March 1994. There Where 31 men and 47 women. whose ranged from 14 to 63 years. The causes of the valvular lesions were 57 rheumatic origin, 18 degenerative, 1 previous endocarditls, 1 prosthetic valve mal-function. There were 25 double valve replacement with or wit out tricuspid valve repair, i M VR and aortic valve repair, 18 MVR and tricuspid valve repair, 1 MVR and aortic and tricuspid valve repair, 10 AVR and mi- tral valve repair, 1 AVR and tricuspid valve repair, 8 mitral aortic valve repair, 13 mitral and tricuspid valve repair. They were improved mean New York Heart Association functional cldss, from 2.72% 121 Early deaths were 5 cases(6.4%). The cause of death wet'e low cArdiac output syndrome. veritricular tachycardia, massive bleeding and cerebral thromboembolism. All the survivors belonged to New York Heart Association functional class I or ll at discharge. The patients who had had valve replacement operation were medicated with warfarin to maintain the level of 30∼ 50% of normal prothrombin time. During follow-up(93.6%, mean 49.9 months), 2 late deaths were developed. One was due to intracranial hemorrhage and the other congestive heart failure. The pre-operative New York Heart Association Functional class IV was statistically sig ificant operat- ive risk factors(p< 0.05).

  • PDF

Development and Animal Tests of Artificial Heart Valves (인공심장판막의 개발 및 동물실)

  • 이재영
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

Mitral Valve Operation Via Extended Transseptal Approach (확장된 경중격 접근방식을 통한 승모판수술)

  • 김학제
    • Journal of Chest Surgery
    • /
    • v.26 no.12
    • /
    • pp.909-914
    • /
    • 1993
  • Complete and optimal visualization of the mitral apparatus is a prerequisite for accurate repair or replacement of the mitral valve. A vertical left atriotomy just posterior to the interatrial groove is the most commonly used approach. However,exposure can be difficult under certain circumstances,such as small left atrium or reoperation. Other approaches have been advocated to deal with this difficult situations. We used an extended transseptal approach in 10 patients and good clinical results and excellent educational effects were obtained. The extended transseptal approach combines two semicircular atrial incisions circumscribing the tricuspid and mitral annuli anteriorly and superiorly,allowing exposure of the mitral valve by deflecting the ventricular side using stay sutures. The right atrium is opened anteriorly along the atrioventricular sulcus. The atrial septum is incised vertically through the fossa ovalis. Right atrial and septal incisions are joined at the superior end of the interatrial septum and extended across the dome of the left atrium to the left atrial appendage. The mitral valve was replaced in all 10 patients. Four of 10 patients had other simultaneous valve procedure: one had aortic valve replacement: 2 underwent tricuspid annuloplasty: 1 had aortic valve replacement and tricuspid annuloplasty. There was no hospital death and complication. Among the 5 patients who had atrial fibrillation preoperatively,4 had atrial fibrillation postoperatively,1 converted to sinus rhythm. The five patients who were in normal sinus rhythm preoperatively remained in sinus rhythm after replacement. A review of our results with this approach confirms the efficacy and safty of this method. So we recommanded this approach for routine mitral valve procedure,especially difficult situations,such as a small left atrium or the redo operation.

  • PDF

Early Results of Mitral Valve Reconstruction in Mitral Regurgitation (승모판막 폐쇄부전에 있어 승모판막 성형술의 단기성적)

  • Kim, Kyung-Hwan;Won, Tae-hee;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.32-37
    • /
    • 2000
  • Background: Reconstruction surgery of mitral valve regurgitation is now considered as an effective operative technique and has shown good long-term results. Although reconstructive surgery of mitral valve has been performed since 1970s, we have started only in early 1990s in full scale because of small number of the mitral regurgitation compared to mitral stenosis and lack of knowledge from the viewpoint of patients and physicians. Material and Method: From January 1992 to December 1996, 100 patients underwent repair of the mitral valve for mitral regurgitation with or without mitral stenosis in Seoul National University Hospital. 45(45%) of the patients were men and 55(55%) were women. The mean age was 39.9$\pm$14.4 years. The causes of the mitral regurgitation were rheumatic in 61, degenerative in 28 and others in 11. According to the Carpentier's pathological classification of mitral regurgitation 5 patients were type I. 55 patients were type II and 40 patients were type III. 7 patients underwent concomitant aortic valvuloplasty and 8 patients underwent aortic valve replacement. 7 patients underwent Maze operation or pulmonary vein isolation. Result: There were no operative death but 3 major operative complications: 2patients were postoperative low cardiac output syndrome(needed intra-aortic ballon pump support) and 1 patient was postoperative bleeding. There was one late death(1.0%) The cause of death was sepsis secondary to acute bacterial endocarditis. 3 patients required reoperation for recurred mitral regurgitation. There were no statistically significant risk factors for reoperation. The other 96 patients showed no or mild degree of mitral regurgitation 99 survivors were in NYHA functional class I or II. There were two throumboembolisms but no anticoagulation-related complications. Conclusion: We concluded that mitral valve repair could be performed successfully in most cases of mitral regurgitation even in the rheumatic and combined lesions with very low operative mortality and morbidity. The early results are very promising.

  • PDF

Thoracoscopic Aortic Valve Replacement assisted with AESOP (Automated Endoscope System for Optimal Positioning) 3000 (AESOP 3000을 이용한 흉강경적 대동맥 판막 치환술)

  • Shin Hong Ju;Kim Hee Jung;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.507-509
    • /
    • 2005
  • Open heart surgery via right thoracotomy can be accomplished in atrial septal defects, and mitral valve diseases. Recently, thoracoscopic atrial septal defect closure, mitral valve repair, Maze operation, and minimal invasive direct coronary artery bypass (MIDCAB) are accomplished with AESOP 3000. However, there is no report of thoracoscopic aortic valve replacement in Korea. We report a successful thoracospic aortic valve replacement assisted with AESOP 3000 in a 31-year-old female patient.

Surgical Treatment of Ventricular Septal Defect Associated with Aortic Insufficiency (대동맥판 폐쇄부전을 동반한 심실중격결손의 외과적 치료)

  • 허동명
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.135-142
    • /
    • 1991
  • From January 1980 to December 1989, thirteen patients underwent operation for ventricular septal defect associated with aortic insufficiency in Kyungpook national university hospital. Ten male and three female patients ranged in age from 3 years to 25 years, with an average age of 11.5 years. Aortic cusp prolapse was found in eight cases[61.5%]. The aortic regurgitation was classified by Sellers` method with grade I in 2 cases, grade II in 9 cases, and grade III in 2 cases. Direct suture or patch repair of ventricular septal defect was performed through the right ventricle. Eight cases were treated only by closure of VSD, 3 cases by plication, but two of the letter were reoperated due to the persistent of aortic regurgitation and fungal endocarditis respectively. Aortic valve replacement were performed in 2 cases at the first operation. There was only one late death[7.7%], which was caused by postoperative fungal endocarditis. Follow-up for twelve patients except one death were followed up for 3 months to six years after operation. Residual aortic regurgitation was noted in six cases[46.2%], but the postoperative course of them were uneventful.

  • PDF

Aortic Root Remodeling Procedure in Marfan Syndrome associated with Aortic Dissection: Yacoub-David Technique (말판증후군과 동반된 해리성 대동맥류에 대한 대동맥 근부 개형술(改型術): Yacoub-David 수술법)

  • Park, Hyung-Joo;Lee, Seong-Jin;Park, Young-Woo;Choi, Tai-Myung;Shin, Won-Yong;Kwak, Soo-Dal;Ko, Jeong-Kwan;Lee, Cheol-Sae;Youm, Wook
    • Journal of Chest Surgery
    • /
    • v.34 no.7
    • /
    • pp.557-558
    • /
    • 2001
  • We operated on a Marfan patient who had Stanford type A acute aortic dissection, aortic root aneurysm, and aortic regurgitation. The Yacoub-David aortic root remodeling procedure which preserves native aortic valve and replaces all three aortic sinuses and ascending aorta by a Dacron graft, was applied for this patient. A 24mm Hemashield graft was designed to three tongues at the aortic root end to meet the shape of the Valsalva sinuses. The patient recovered from the procedure uneventfully and there was no aortic regurgitation posto-peratively.

  • PDF

Reoperations for Prosthetic Valve Replacement (인공판막치환술후 재수술)

  • 유영선
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1090-1097
    • /
    • 1991
  • Between January 1981 and January 1991, 554 patients underwent prosthetic valve replacement. A bioprosthetic valve was replaced in 238 cases and mechanical valve 316 cases. Thirty-eight patients underwent 40 reoperations for repair or replacement, an average of 53.6 months after initial implantation. There were 21 women and 19 men, aged 12 to 60 years[mean 35.3]. A bioprosthetic valve was implanted in 31 cases and a mechanical valve in 9 cases for initial operation. Indications for reoperation were primary tissue failure in 23 cases[57.5%], endocarditis in 9[22.5%], periprosthetic leak in 4[10%]. and valve thrombosis in 4[10%]. Operations performed included 5 aortic valve replacements, 26 mitral valve replacement, 8 double valve replacements, and 1 thrombectomy. A mechanical valve was replaced in 33 cases[84.6%] and a bioprosthesis in 6[15.4Zo] for reoperation. A second reoperation was required in 2 patients. Surgical mortality was 10% . Among the 34 early survivors followed-up for an average of 19.8 months. there was 1 late death and 3 were lost to follow-up. Among the 30 late survivors being followed up, 28[93.3%] remained in New York Heart Association Class I or II and two in Class III [6.7%].

  • PDF