• Title/Summary/Keyword: Aortic aneurysm. arch

Search Result 57, Processing Time 0.016 seconds

Nicardipine Hydrochloride Injectable Phase IV Clinical Trial-Study on the antihypertensive effect and safely of nicardipine for acute aortic dissection (급성대동맥해리에 대한 혈압강하요법으로서의 Nicardipine.HCI 주사액(Perdipine$^{circledR}$)의 유효성 및 안전성을 검토하기 위한 다기관 공동, 공개 제4상 임상시험)

  • Kim, Kyung-Hwan;Moon, In-Sung;Park, Jang-Sang;Koh, Yong-Bok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.35 no.4
    • /
    • pp.267-273
    • /
    • 2002
  • Background: We performed a phase IV clinical trial to examine the usefulness of a continuous infusion of nicardipine hydrochloride to control hypertension in patients with acute aortic dissection. material and Method: Systolic/diastolic blood pressure, and heart rate were monitored before and after the intravenous administration of nicardipine in 31 patients with aortic diseases. The period of nicardipine administration in each patient was from 3 to 14 days. Efficacy was evaluated by determining the average amount of blood pressure reduction on the 3rd day of drug administration. The dosage of another antihypertensive agent was slowly tapered down, and ultimately replaced by the test drug. Result: 28 patients were diagnosed as acute aortic dissection, 2 patients as rupture of the aortic arch aneurysm, and 1 patient as traumatic aortic rupture. Mean age was 53.9 $\pm$ 14.9(29~89) years, and 21 patients(67.7%) were male. 14 patients(32.3%) had complications associated with underlying aortic disease: aortic insufficiency in 7, hemopericardium in 6, acute renal failure in 1, paraplegia in 1, lower extremity ischemia in 1, and hemothorax in 1. The time needed to reach the target blood pressure was within 15 minutes in 16, from 15 to 30 minutes in 10, from 30 to 45 minutes in 3 and from 45 to 60 minutes in 2, and their baseline average systolic, diastolic, and mean arterial blood pressures(mmHg) were 147$\pm$23, 82.3$\pm$ 18.6, and 104 $\pm$ 18, respectively. Average systolic, diastolic, and mean arterial blood pressures(mmHg) on the third day of nicardipine infusion were 119$\pm$ 12, 69$\pm$9, and 86$\pm$8, and they all showed statistically significant decrease(p<0.05). The average systolic, diastolic, and mean arterial blood pressure(mmHg) after the discontinuation of the nicardipine infusion were 119 $\pm$ 15, 71 $\pm$ 14, and 86$\pm$ 13, respectively. No significant difference was observed between the average pressures measured on the third day and those measured after the discontinuation of the nicardipine infusion, and no definite side effects were observed during the study period. Conclusion: Nicardipine hydrochloride was both effective and safe at controlling blood pressure in patients with acute aortic dissection.

Acute Type A Aortic Dissection Mimicking Penetrating Atherosclerotic Ulcer (침투성 동맥경화성 궤양과 흡사한 급성 A형 대동맥 박리증 -1l례 보고 -)

  • Choi, jae-Sung;Kwak, Jae-Gun;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.36 no.1
    • /
    • pp.30-34
    • /
    • 2003
  • As classical acute aortic dissection, atherosclerotic penetrating ulcers and intramural hematoma have different pathophysiology and natural history, treatment strategy should be different and, therefore, accurate differential diagnosis is necessary. However, these three aortic diseases may be indistinguishable by clinical observation and even by various diagnostic modalities such as cardiac echocardiography, CT and MRI. The patients was a 71-year-old female with chief complaints of anterior chest pain, nausea and vomiting which occurred suddenly 3 days before admission. CT angiographic with 3 dimensional reconstruction shows intramural hematoma in ascending aorta, aortic arch, descending thoracic aorta and right brachiocephalic trunk, heompericardium, and blood in mediastinum and both pleural cavities. The CT angiographic finding of focal out-bulging in the ascending thoracic aorta was diagnosed as penetrating atherosclerotic ulcer. The patient underwent emergency operation under a preoperative diagnosis of penetrating atherosclerotic ulcer with a sign of aortic rupture. In the intraoperative findings, however, intimal tear was seen in the anterior portion of the ascending aorta about 1cm below the brachiocephalic trunk and falselumen appeared after hematoma was removed from the layer of tunica media. We report a case of type A aortic dissection which mimicked clinical and diagnostic features of penetrating atherosclerotic ulcer.

Clinical Analysis of the Operative Results of the Type A Aortic Dissection according to the Location of the Intimal Tear (급성 Type A 대동맥 박리에서 내막 파열의 위치에 따른 수술 성적의 분석)

  • Kim, Hyuck;Chung, Ki-Chun;Jee, Heng-Ok;Kang, Jung-Ho;Chung, Won-Sang;Lee, Chul-Bum;Chon, Soon-Ho;Kim, Young-Hak
    • Journal of Chest Surgery
    • /
    • v.37 no.6
    • /
    • pp.517-523
    • /
    • 2004
  • Background: The location of intimal tear can vary in type A acute aortic dissection. The aim of this study was to assess the operative result according to the intimal tear site. Material and Method: From January, 1995 to May, 2003, 18 patients underwent surgery for acute type A aortic dissection. The patients were classified according to the intimal tear site. In Group I (n=11), the intimal tear site was located within the ascending aorta, in Group II (n=7), the intimal tear site was located in the aortic arch, descending aorta, or intramural hematoma only. All clinical data were analyzed retrospectively. Result: In Group I, the operative time, cardiopulmonary bypass time, aorta cross clamp time and circulatory arrest time were 381.5$\pm$81.0 min, 223.5$\pm$42.5 min, 146.4$\pm$34.8 min and 36.5$\pm$17.4 min, respectively; and in group II, 461.7$\pm$54.0 min, 252.5$\pm$45.3 min, 162.5$\pm$45.3 min and 47.0$\pm$14.4 min respectively. All of those were greater in group II. The overall hospital mortality rate was 27.8% (5/18) and was significantly higher in Group II (57.1%)(p=0.003) compared to that in Group I (9.1%). The causes of death were hemorrhage (n=1) in group I and hemorrhage (n=2), multiple organ failure (n=1), and rupture of abdominal aorta (n=1) in group II. Conclusion: Surgical treatment of acute type A aortic dissection with intimal tear in the ascending aorta results in an acceptable mortality rate, but in patients with intimal tear in the aortic arch or descending aorta, the operative mortality still remains high when only ascending aorta replacement was performed. In these circumstances, in order to improve surgical results, efforts to include the intimal tear site in the operative procedure will be needed.

Early Results of Aortic Valve-sparing Procedures in Patients with Annuloaortic Ectasia (대동맥륜대동맥확장(Annuloaortic Ectasia) 환자에서 대동맥판막을 보존하면서 시행된 대동맥근부 및 상행대동맥 치환술의 단기 성적)

  • Sung Kiick;Park Kay-Hyun;Lee Young Tak;Jun Tae-Gook;Yang Ji-Hyuk;Kim Su Wan;Kim Jin Sun;Cho Sung Woo;Kim Si Wook;Choi Jin Ho;Park Pyo Won
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.483-488
    • /
    • 2005
  • Aortic valve-sparing procedures could reduce valve-related morbidity, but may increase operative risks; therefore, these procedures could not be performed routinely. We attempted to find out the early results while focusing on the operative risks associated with these procedures in our hospital. Material and Method: From May 1996 to July 2003, 26 patients underwent these procedures including 15 patients with Marfan syndrome and 1 patient with Behcet disease. There were 17 men and 9 women with mean age of $37.9\pm19.2$ years (range: 6 months-74 years). Ten patients had ascending aortic dissection, 18 patients had more than moderate degree of aortic valve insufficiency (AI). Two types of valve-sparing procedures were performed: valve reimplantation in 14 and root remodeling in 12 patients. Associated procedures were performed as follows: aortic valve plasty in 6, mitral valve plasty in 5, hemi-arch replacement in 4, total arch replacement in 2, coronary artery bypass surgery in 1 and Maze procedure in 1 patient(s). Result: In four patients, valve-sparing procedures were converted to Bentall procedures during operation. Including these patients, there was no operative deaths, 3 patients underwent re-operation due to bleeding, 1 patient had permanent pacemaker. The median duration of ICU stay was 45.5 hours, the median duration of hospital stay was 10.5 days. In 22 patients excluding 4 converted patients, intraoperative transesophageal echocardiogram (TEE) showed less than mild degree of AI in all except one who had not received intra-operative TEE in the beginning and showed moderate degree of AI at discharge. The mean duration of follow-up was $21.2\pm27.4$ months. All patients were alive except one who died during other departmental surgery. In 3 patients, more than moderate degree of AI was recurred, but there were no reoperation. Conclusion: Aortic valve-sparing procedures could be performed relatively safely in selected patients who had annuloaortic ectasia.

The Role of Axillary Artery Cannulation in Surgery for Type A Acute Aortic Dissection (급성 상행대동맥 박리증 수술에서 액와동맥 삽관술의 역할)

  • 유지훈;박계현;박표원;이영탁;김관민;성기익;양희철
    • Journal of Chest Surgery
    • /
    • v.36 no.5
    • /
    • pp.343-347
    • /
    • 2003
  • Background: The femoral artery is the most common site of canuulation for cardiopulmonary bypass in surgery for type A aortic dissection. Recently, many surgeons prefer the axillary artery to the femoral artery as the arterial cannulation site for several benefits. We evaluated the safety and usefulness of axillary artery cannulation in surgery for acute type A aortic dissection. Material and Method: Between Oct. 1995 and Sep. 2001, 71 patients underwent operations for acute type A aortic dissection. The arterial cannula was inserted into the axillary artery in 31 patients (AXILLARY group, mean age=56), and into the femoral artery in 40 patients (FEMORAL group, mean age=57). We retrospectively compared the incidence of mortality, morbidities, and hospital course. Result: The mean duration of cardiopulmonary bypass and circulatory arrest were significantly shorier in the AXILLARY group (207 min and 39min, respectively) than in the FEMORAL group (263min and 49 min, respectively; P<0.05). Postoperative hospital stay was significantly shorter in the AXILLARY group than in the FEMORAL group (mean 15 days vs. 35 days, p<0.05). Although there was no difference in the incidence of new-onset permanent neurological dysfunction (3.2%, in the AXILLARY group, 2.5% in the FEMORAL group), the incidence of transient neurological dysfunction was significantly lower in the AXILLARY group (12.9% vs. 25%, p<0.05). In the FEMORAL group, two patients needed urgent conversion to cannulation site due to arch vessel malperfusion. In the AXILLARY group, there was only one patient who had a complication related to the cannulation, i.e., median nerve injury. Conclusion: Axillary artery cannulation was safe and helpful in decreasing the cerebral ischemic time and incidence of transient neuroligcal dysfunction in surgery for acute type A aortic dissection, It enabled us to approach the patients with aortic arch pathology more aggressively.

Composite Graft Aortic Root Replacement with Coronary Button Reimplantation: The Early and Mid-Term Results (Composite graft를 이용한 대동맥근부 치환술: Button 술식의 중단기 결과)

  • 나찬영;백만종;김웅한;오삼세;김수철
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.356-364
    • /
    • 2002
  • Background: This study was undertaken to investigate the outcome of composite graft aortic root replacement using coronary button reimplantation technique for the treatment of aneurysms of the ascending aorta involving the aortic root. Material and Method: Between April 1995 and September 2001, 54 patients having aortic root replacement with a composite valve graft using direct coronary button reimplantation were reviewed retrospectively. Left ventricular dysfunction was present in 14 patients(25.9%), aortic regurgitation in 48(89%), and Marfan's syndrome in 17(31.5%). The indications for operation were annuloaortic ectasia in 29 patients(53.7%), aortic dissection in 11(20.4%), aneurysms of the ascending aorta involving aortic root in 12(22.2%), and aortitis in 2(3.7%). Six patients(11.1%) had previous cardiac or ascending aortic operations. Concomitant procedures were arch replacement in 21 patients(38.9%), coronary artery bypass graft in 7(13%), mitral valve repair or replacement in 4(7.4%), and others in 6. The mean time of circulatory arrest, total bypass, and aortic crossclamp were 18 $\pm$ 9 minutes, 177 $\pm$ 42 minutes, and 127 $\pm$ 31 minutes, respectively. Result: There was 1 early death(1.9%). Mean follow-up was 24.6$\pm$ 19.5 months. There were two late deaths(3.8%) including one death due to the traumatic cerebral hemorrhage. The Kaplan-Meier survival rate was 98.0 $\pm$ 2.0% and 93.1 $\pm$ 5.1% at 1 and 6 years, respectively. Two patients required reoperation owing to a false aneurysm at the root anastomosis site and a malfunction of prosthetic aortic valve(3.8%). Staged operation for dissection of the remaining thoracoabdominal aorta was performed in 1 patient. The freedom rate from reoperation was 97.8 $\pm$ 2.0% and 65.3 $\pm$ 26.7% at 1 and 6 years, respectively.

Clinical Application of Compressed Spectral Array During Deep Hypothermia (초저체온하 대동맥수술 환자에서 완전 순환차단의 안전한 체온 및 기간에 대한 연구 - 뇌파 Compressed Spectral Array의 임상적 응용 -)

  • 장병철;유선국
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.752-759
    • /
    • 1997
  • Profound hypothermia protects . cerebral function during total circulatory arrest(TCA) in the surgical treatment of a variety of cardiac and aortic diseases. Despite its importance, there is no ideal technique to monitor the brain injury from ischemia. Since 1994, we have developed compressed spectral array(CSA) of electroencephalography(EEG) and monitored cerebral activity to reduce ischemic injury. The purposes of this study are to analyse the efficacy of CSA and to establish objective criteria to consistently identify the safe level of temperature and arrest time. We studied 6 patients with aortic dissection(AD, n=3) or aortic arch aneurysm(n=3, ruptured in 2). Body temperatures from rectum and esophagus and the EEG were monitored continuously during cooling and rewarming period. TCA with cerebral ischemia was performed in 3 patients and TCA with selective cerebral perfusion was performed in 3 patients. Total ischemic time was 30, 36 and 56 minutes respectively for TCA group and selective perfusion time was 41, 56 and 92 minutes respectively for selective perfusion group. The rectal temperatures for flat EEG were between 16.1 and 22. $1^{\circ}C$ (mean: 18.4 $\pm$ 2.0): the esophageal temperatures between 12.7 and $16.4^{\circ}C$ (mean $14.7\pm1.6).$ The temperatures at which EEG reappeared $5~15.4^{\circ}C$ for esophagus. There was no neurological defic t and no surgical mortality in this series. In summary, the electrical cerebral activity Teappeared within 23 minutes at the temperature less than $16^{\circ}C$ for rectum. It seemed that $15^{\circ}C$ of esophageal temperature was not safe for 20 minutes of TCA and continuous monitoring the EEG with CSA to identify the electrocerebral silence was useful.

  • PDF