• Title/Summary/Keyword: Aortic Valve Stenosis

Search Result 147, Processing Time 0.021 seconds

Left Coronary Ostial Obstruction by a Dislocated Sutureless Aortic Valve Prosthesis: Redo Aortic Valve Replacement with Hybrid Coronary Revascularization: A Case Report

  • Seungmo Yoo;Hong Rae Kim;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • v.56 no.5
    • /
    • pp.359-361
    • /
    • 2023
  • Coronary ostium obstruction due to dislodgement of the prosthetic valve is a rare and life-threatening complication, and particular caution is required for sutureless aortic valve replacement (AVR) with concomitant valvular surgery. In general, coronary artery bypass surgery is performed when coronary ostium obstruction occurs after AVR, but other options may need to be considered in some cases. Herein, we present a case of coronary artery occlusion in an 82-year-old female patient who had undergone AVR and mitral valve replacement for aortic valve stenosis and mitral valve stenosis at the age of 77 years. A hybrid procedure involving redo AVR and percutaneous coronary intervention after left main coronary ostium endarterectomy was performed. To summarize, we present a case of hybrid AVR in a patient with coronary artery obstruction after AVR that was successfully managed using this method.

Mass Reduction and Functional Improvement of the Left Ventricle after Aortic Valve Replacement for Degenerative Aortic Stenosis

  • Shin, Su-Min;Park, Pyo-Won;Han, Woo-Sik;Sung, Ki-Ick;Kim, Wook-Sung;Lee, Young-Tak
    • Journal of Chest Surgery
    • /
    • v.44 no.6
    • /
    • pp.399-405
    • /
    • 2011
  • Background: Left ventricular (LV) hypertrophy caused by aortic valve stenosis (AS) leads to cardiovascular morbidity and mortality. We sought to determine whether aortic valve replacement (AVR) decreases LV mass and improves LV function. Materials and Methods: Retrospective review for 358 consecutive patients, who underwent aortic valve replacement for degenerative AS between January 1995 and December 2008, was performed. There were 230 men and 128 women, and their age at operation was $63.2{\pm}10$ years (30~85 years). Results: There was no in-hospital mortality, and mean follow-up duration after discharge was 48.9 months (2~167 months). Immediate postoperative echocardiography revealed that LV mass index and mean gradient across the aortic valve decreased significantly (p<0.001), and LV mass continued to decrease during the follow-up period (p<0.001). LV ejection fraction (EF) temporarily decreased postoperatively (p<0.001), but LV function recovered immediately and continued to improve with a significant difference between preoperative and postoperative EF (p<0.001). There were 15 late deaths during the follow-up period, and overall survival at 5 and 10 years were 94% and 90%, respectively. On multivariable analysis, age at operation (p=0.008), concomitant coronary bypass surgery (p<0.003), lower preoperative LVEF (<40%) (p=0.0018), and higher EUROScore (>7) (p=0.045) were risk factors for late death. Conclusion: After AVR for degenerative AS, reduction of left ventricular mass and improvement of left ventricular function continue late after operation.

Comparison of Early Clinical Results of Transcatheter versus Surgical Aortic Valve Replacement in Symptomatic High Risk Severe Aortic Stenosis Patients

  • Yu, Woo Sik;Chang, Byung-Chul;Joo, Hyun Chel;Ko, Young-Guk;Lee, Sak
    • Journal of Chest Surgery
    • /
    • v.46 no.5
    • /
    • pp.346-352
    • /
    • 2013
  • Background: Transcatheter aortic valve implantation (TAVI) has been an alternative to conventional aortic valve replacement (AVR) in old and high risk patients. The goal of this study is to compare the early outcomes of conventional AVR vs. TAVI in high risk severe AS patients. Methods: From January 2008 to July 2012, 44 high risk severe aortic stenosis patients underwent conventional AVR, and 15 patients underwent TAVI. We compared echocardiographic data, periprocedural complication, and survival. The mean follow-up duration was $14.5{\pm}10$ months (AVR), and $6.8{\pm}3.5$ months (TAVI), respectively. Results: AVR group was younger ($78.2{\pm}2.4$ years vs. $82.2{\pm}3.0$ years, p<0.001) and had lower operative risk (Euroscore: $9.4{\pm}2.7$ vs. $11.0{\pm}2.0$, p=0.044) than TAVI group. There was no significant difference in early mortality (11.4% vs. 13.3%, p=0.839), and 1 year survival ($87.4%{\pm}5.3%$ vs. $83.1%{\pm}1.1%$, p=0.805). There was no significant difference in postoperative functional class. There was no significant difference in periprocedural complication except vascular complication (0% [AVR] vs. 13.3% [TAVI], p=0.014). TAVI group had more moderate and severe paravalvular leakage. Conclusion: In this study, both groups had similar periprocedural morbidity, and mortality. However, TAVI group had more greater than moderate paravalvular leakage, which can influence long-term outcome. Since more patients are treated with TAVI even in moderate risk, careful selection of the patients and appropriate guideline need to be established.

Two-Dimensional Echocardiographic Prediction of Prosthetic Aortic Valve Size (심초음파도를 이용한 대동맥인공판막치수 예)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.655-658
    • /
    • 1987
  • Aortic annulus size was measured by two-dimensional echocardiography [2DE] in 29 patients undergoing aortic valve replacement or double valve replacement in order to predict prosthetic aortic valve size. Fifteen patients had aortic stenoinsufficiency, eleven had aortic insufficiency, and three had aortic stenosis. 2DE measurements of aortic annulus diameter, as determined from the parasternal long-axis view, demonstrated a high correlation with actual prosthetic valve size implanted at surgery [r=0.85, p<0.05]. 2DE exactly predicted actual prosthetic valve size in 8 of 29 patients [27.6%], was within 1mm of prosthetic valve size in 11 of 29 patients [37.9%], was within 2mm of prosthetic valve size in 8 of 29 patients, and was within 3mm of prosthetic valve size in 2 patients.

  • PDF

Congenital Quadricuspid Semilunar Valve - A case report - (선천성 사엽성 반월형 판막 - 1예 보고 -)

  • Seo, Min-Bum;Seo, Hong-Joo
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.361-363
    • /
    • 2009
  • A 17-year-old male patient was referred with symptoms of dyspnea. Multi-detector computerized tomography (MDCT) and echocardiography evaluation revealed quadricuspid aortic and pulmonary valves, an atrial septal defect (ASD), and pulmonary stenosis. We closed the ASD using a bovine patch and performed a commissurotomy of the pulmonary valve. Quadricuspid semilunar valves are very rare congenital abnormalities that are reported to occur nine times more frequently in the pulmonic valve than in the aortic valve. According to the Hurwitz Roberts classification, the aortic valve was type A, and the pulmonic valve was type B. The aortic valve normal function, but the pulmonic valve was stenotic and had abnormal function.

Aortic Stenosis in Systemic Lupus Erythematosus Syndrome (전신성 흥반성 낭창에 동반된 대동맥 판막 협착증의 수술 1에)

  • 최주원;김우식;고행일;강윤경;김용인
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.613-616
    • /
    • 2004
  • Systemic lupus erythemotosus (SLE) is an autoimmune disorder with dermal, renal, and cardiac manifestations. It frequently has cardiovascular complications such as pericarditis, myocarditis, and valvular heart diseases. Valvular heart diseases in SLE comes mainly in the form of mitral or aortic insufficiencies. Report of aortic stenosis is extremely rare. Surgical treatments of valvular heart disease in SLE are not done frequently because of complications in other organs. Aortic stenosis developed in a 59 year-old woman with SLE, and aortic valve replacement was done successfully.

Early Clinical Experience with Sutureless Aortic Valve Replacement for Severe Aortic Stenosis

  • Kim, Do Jung;Kim, Hyo-Hyun;Lee, Shin-Young;Lee, Sak;Chang, Byung-Chul
    • Journal of Chest Surgery
    • /
    • v.51 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • Background: Sutureless aortic valve replacement (SU-AVR) has been developed as an alternative surgical treatment for patients with symptomatic severe aortic stenosis (AS). The aim of this study was to evaluate the clinical outcomes of SU-AVR through an assessment of hemodynamic performance and safety. Methods: From December 2014 to June 2016, a total of 12 consecutive patients with severe AS underwent SU-AVR. The endpoints were overall survival and valve-related complications (paravalvular leakage, valve thrombosis, migration, endocarditis, and permanent pacemaker implantation). The mean follow-up duration was $18.1{\pm}8.6months$. Results: The mean age of the patients was $77.1{\pm}5.8years$ and their mean Society of Thoracic Surgeons score was $9.2{\pm}17.7$. The mean cardiopulmonary bypass and aortic cross-clamp times were $94.5{\pm}37.3$ minutes and $54.9{\pm}12.5minutes$, respectively. Follow-up echocardiography showed good prosthesis function with low transvalvular pressure gradients (mean, $13.9{\pm}8.6mm\;Hg$ and peak, $27.2{\pm}15.0mm\;Hg$) at a mean of $9.9{\pm}4.2months$. No cases of primary paravalvular leakage, valve thrombosis, migration, or endocarditis were reported. A new permanent pacemaker was implanted in 1 patient (8.3%). The 1-year overall survival rate was $83.3%{\pm}10.8%$. Conclusion: Our initial experience with SU-AVR demonstrated excellent early clinical outcomes with good hemodynamic results. However, there was a high incidence of permanent pacemaker implantation compared to the rate for conventional AVR, which is a problem that should be solved.

Surgical Treatment of Supravalvular Aortic Stenosis (대동맥 판상부 협착증의 수술요법)

  • 유재현;유환국;이원용;나찬영;정윤섭;김응수;백완기;한재진;이영탁
    • Journal of Chest Surgery
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 1993
  • Supravalvular aortic stenosis is an uncommon, congenital narrowing of ascending aorta just above aortic valve. Eleven patients underwent an aortoplasty to relieve supravalvular aortic stenosis at Sejong General Hospital from July 1985 to December 1991. Age ranged from 5 to 14 years(median 9 years). There were 7 male and 4 female patients. Seven patients had characteristics of Williams' syndrome including elfin face and mental retardation. All patients had localized, hourglass type but 4 patients had atypical findings. Preoperative left ventricula-aortic pressure gradient ranged from 40 to 190 mmHg(mean 88 mmHg). To relieve severe supravalvular aortic stenosis, extended aortoplasty was used in 7 patients and standard aortoplasty in 4 patients. Postoperative pressure gradient ranged from 0 to 40 mmHg (mean 16.6 mmHg). Follow-up pressure gradient with Doppler ranged from 0 to 88mmHg(mean 32.5mmHg).

  • PDF

A Report of Left Heart Failure by Aortic Valvular Stenosis in a Mongrel Dog (개에서 대동맥판막협착에 의한 좌심부전 증례)

  • 김관우;황순신;김방실;김유정;조경오;오기석;김종택;박인철;손창호
    • Journal of Veterinary Clinics
    • /
    • v.21 no.1
    • /
    • pp.83-86
    • /
    • 2004
  • A 4 year old mixed female dog was presented dyspnea, anorexia and syncope. In blood smear test, a lot of heartworm larvae were observed. In thoracic radiography, "reverse D" shape was observed. So, this case was considered with heartworm disease. In echocardiography, marked left heart hypertrophy was presented. In M-mode view, aortic valvular stenosis was found. After mongrel dog died, aortic valvular stenosis was reconfirmed in necropsy. After all, the dog died of pulmonary edema because of aortic valvular stenosis caused left heart failure.t failure.

Occlusion of the Right Coronary Artery Ostium due to Rheumatic Aortic Valve Stenosis (류마티스성 대동맥 판막협착증에 의한 우관상동맥 개구부 폐쇄)

  • Seo, Hong-Joo;Oh, Sam-Se;Kim, Jae-Hyun;Kim, Soo-Cheol;Na, Chan-Young
    • Journal of Chest Surgery
    • /
    • v.40 no.6 s.275
    • /
    • pp.445-447
    • /
    • 2007
  • Occlusion of a coronary artery ostium and especially occlusion of the right by an aortic cusp is a rare condition. We experienced an adult patient with occlusion of the right coronary ostium that was due to fusion of the right coronary cusp to the aortic wall along with underlying rheumatic aortic valve stenosis. During the operation, the adherent right coronary cusp was excised. After confirming that the right coronary ostium was patent, the other cusps were removed, and this followed by replacement of the aortic valve with a mechanical valve. The postoperative course was uneventful.