• 제목/요약/키워드: Aortic Valve, replacement

검색결과 411건 처리시간 0.029초

경식도 심초음파 검사를 이용한 판막대치술 환자의 평가 (Postoperative Transesophageal Echocardiographic Evaluation in Patients with Cardiac Valve Replacement)

  • 조건현
    • Journal of Chest Surgery
    • /
    • 제24권3호
    • /
    • pp.265-270
    • /
    • 1991
  • Since advent of the prosthetic cardiac valve replacement, much efforts for accurate assessing value function in-vivo have been attempted. To evaluate the postoperative functional and morphological status of the replaced cardiac valve prosthesis, 33 patients with valve replacement were studied by transthoracic and transesophageal 2-dimensional echocardiac imaging as well as by color Doppler flow velocity imaging. Twenty four patients had mitral valve replacement. 6 patients had aortic valve replacement and 3 patients had both mitral and aortic valve replacement. There were 34 mechanical and 2 biological prosthesis. Comparing to transthoracic echocardiography, transesophageal approach showed transvalvular regurgitant jet flow amid the prosthetic mitral valve ring during. systole and much clear visualization of cardiac chamber behind prosthesis which could give shadowing effect to ultrasound beam. According to the quantitative grading by the length and area of mitral regurgitant flow, 24 out of 27 mitral valves revealed mild degree regurgitation considered as physiological after prosthetic bileaflet valve replacement and the other 3 valves including 2 biological prosthesis had moderate degree regurgitation which was regarded as pathologic one. 2 cases of left atrial thromboses and 1 case of paravalvular leakage which were not visible by transthoracic approach were identified by transesophageal echocardiography in patients with mitral valve replacement and patients with aortic valve replacement respectively. We conclude that in patients with prosthetic mitral valve replacement, transesophageal 2-dimensional imaging with color Doppler can suggest reliable information beyond that available from the transthoracic access even though it gives patient some discomfort to proceed.

  • PDF

이오네스크-쉴리 판막을 이용한 심장판막치환술에 관한 임상적 고찰 (Ionescu-Shiley valve replacement: mid-term folow-up)

  • 심영목;이영균
    • Journal of Chest Surgery
    • /
    • 제16권4호
    • /
    • pp.458-469
    • /
    • 1983
  • Between October, 1978, and December, 1982, Glutaraldehyde-stablized pericardial xenografts [Ionescu-Shiley valve] were used for heart valve replacement in 409 patients.[251 mitral, 49 aortic, 11 tricuspid, and 98 multiple valve replacement]. There were 31 early deaths [7.6%], and 371 operative survival were observed for a total of 507.6 years over a period of 1 to 44 months. [mean 17 months]. Actuarial analysis of late results indicates an excepted survival rate at 4 years of 86.25.4% for patients with mitral, 79.37.1% for patients with aortic valve replacement. Actuarial survival rates for total patients at 4 years was 77.88.2%. The rate of systemic embolism has been 1.6% per patient-year for mitral and 1.8% per patient-year for aortic group in the presence of anticoagulation treatment. Among the 6 embolic episodes, 2 patients were died. The incidence of hemorrhagic complication was 1.3% per patient-year for anticoagulated patients. There were 6 confirmed valve failures, five in mitral and one in aortic position. Re-replacement of destructed valve was performed in one patient and others were treated medically. Among the 6 episodes, 3 occurred in children [Below 15 years], it account almost 9 times higher than adult. Our clinical data compare very favorable with those obtained with other available prostheses and tissue valves, but it should be considered to give short-term anticoagulation therapy to hemodynamically stable patients and aortic valve patients, and other prosthetic valve must be considered to use in children.

  • PDF

Valve-Sparing Root Replacement in a Turner Syndrome Patient with Bicuspid Aortic Valve and Juxtacommissural Origin of the Right Coronary Artery: A Case Report

  • Son, Dong Hyeon;Cho, Sungkyu;Song, Mi Kyoung
    • Journal of Chest Surgery
    • /
    • 제55권5호
    • /
    • pp.413-416
    • /
    • 2022
  • A 32-year-old woman diagnosed with Turner syndrome presented to the hospital for an evaluation of cardiovascular complications. Preoperative computed tomography (CT) and echocardiography showed progression of aortic root and ascending aorta dilatation, as well as a bicuspid aortic valve. There was no evidence of aortic regurgitation. We planned valve-sparing aortic root replacement and ascending aorta replacement with a high risk of aortic rupture. Intraoperatively, we incidentally found a juxtacommissural origin of the right coronary artery (RCA). We performed aortic valve reimplantation using a graft designed with a key-shaped hole to wrap the juxtacommissural-origin RCA by modifying the Florida sleeve technique. Coronary blood flow was patent on postoperative CT angiography, and there was no evidence of aortic regurgitation on postoperative echocardiography. The patient was discharged from the hospital on postoperative day 7 without any complications.

심초음파도를 이용한 대동맥인공판막치수 예 (Two-Dimensional Echocardiographic Prediction of Prosthetic Aortic Valve Size)

  • 박창권
    • Journal of Chest Surgery
    • /
    • 제20권4호
    • /
    • pp.655-658
    • /
    • 1987
  • Aortic annulus size was measured by two-dimensional echocardiography [2DE] in 29 patients undergoing aortic valve replacement or double valve replacement in order to predict prosthetic aortic valve size. Fifteen patients had aortic stenoinsufficiency, eleven had aortic insufficiency, and three had aortic stenosis. 2DE measurements of aortic annulus diameter, as determined from the parasternal long-axis view, demonstrated a high correlation with actual prosthetic valve size implanted at surgery [r=0.85, p<0.05]. 2DE exactly predicted actual prosthetic valve size in 8 of 29 patients [27.6%], was within 1mm of prosthetic valve size in 11 of 29 patients [37.9%], was within 2mm of prosthetic valve size in 8 of 29 patients, and was within 3mm of prosthetic valve size in 2 patients.

  • PDF

Suspending Commissural Sutures for Aortic Valve Exposure in Minithoracotomy Aortic Valve Replacement

  • Kim, Eunji;Kim, Joon Bum
    • Journal of Chest Surgery
    • /
    • 제54권6호
    • /
    • pp.551-553
    • /
    • 2021
  • Although it is attractive, a limitation of aortic valve (AV) replacement (AVR) through a mini-thoracotomy approach (mini-AVR) is the limited exposure of the AV. Here, we present a simple exposure technique named "suspending commissural sutures" for a more efficient mini-AVR. The technique involves making 3 half-depth stitches with 1-0 silk at each of the commissures, which are anchored to each corresponding pericardial surface. These stitches are tightened up so that the aortic root is axially expanded and is pulled upward. The technique of suspending commissural stitches seems to offer reasonable exposure of the AV in mini-AVR, and shows excellent early surgical outcomes.

Left Coronary Ostial Obstruction by a Dislocated Sutureless Aortic Valve Prosthesis: Redo Aortic Valve Replacement with Hybrid Coronary Revascularization: A Case Report

  • Seungmo Yoo;Hong Rae Kim;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • 제56권5호
    • /
    • pp.359-361
    • /
    • 2023
  • Coronary ostium obstruction due to dislodgement of the prosthetic valve is a rare and life-threatening complication, and particular caution is required for sutureless aortic valve replacement (AVR) with concomitant valvular surgery. In general, coronary artery bypass surgery is performed when coronary ostium obstruction occurs after AVR, but other options may need to be considered in some cases. Herein, we present a case of coronary artery occlusion in an 82-year-old female patient who had undergone AVR and mitral valve replacement for aortic valve stenosis and mitral valve stenosis at the age of 77 years. A hybrid procedure involving redo AVR and percutaneous coronary intervention after left main coronary ostium endarterectomy was performed. To summarize, we present a case of hybrid AVR in a patient with coronary artery obstruction after AVR that was successfully managed using this method.

Valve Sparing Aortic Root Replacement in Children with Loeys-Dietz Syndrome

  • Sim, Hyung-Tae;Seo, Dong Ju;Yu, Jeong Jin;Baek, Jae Suk;Goo, Hyn Woo;Park, Jeong-Jun
    • Journal of Chest Surgery
    • /
    • 제48권4호
    • /
    • pp.272-276
    • /
    • 2015
  • Loeys-Dietz syndrome (LDS) is an autosomal dominant connective tissue disorder that is characterized by aggressive arterial and aortic disease, often involving the formation of aortic aneurysms. We describe the cases of two children with LDS who were diagnosed with aortic root aneurysms and successfully treated by valve-sparing aortic root replacement (VSRR) with a Valsalva graft. VSRR is a safe and suitable operation for children that avoids prosthetic valve replacement.

대동맥판부전이 동반된 상행대동맥류의 외과적 치험 (Surgical Management of Aneurysm of the Ascending Aorta with Aortic Insufficiency)

  • 박만실
    • Journal of Chest Surgery
    • /
    • 제26권6호
    • /
    • pp.457-462
    • /
    • 1993
  • We retrospectively studied 34 patients who underwent operations of ascending aortic aneurysm and aortic valve replacement from August 1979 to July 1992 at the Yonsei Cardiovascular Center. Eight patients underwent supracoroanry non-composite graft replacement and separate aortic valve replacement[group I]. Twenty six patients underwent valved composite graft replacement with reimplantation of coronary arteries[group II]. Two cases in group II died within 1 month after the operation. Among the 32 survivors 28 patients have been followed up for an average of 59 months ranging from 1 months to 159 months. During the follow up periods, a pseudoaneurysm around the ascending aorta and a newly developed dissecting aneurysm in remaining aorta were noted in group II. There were 6 late deaths: 2 cases in group I and 4 cases in group II. Three cases among the 6 late deaths have stigmata of Marfan`s syndrome[1 cases in group I and 2 case in group II]. There was no statistically significant difference in actuarial survival rates between group I and group II[p > 0.05]. This study suggests that non-composite supracoronary graft interposition with separate aortic valve replacement is a safe surgical technique in patients who have normal aortic annulus and normal position of coronary ostia. However in degenerative disease such as cystic medial necrosis, composite graft replacement is recommended because this procedure eliminates entire abnormal tissue.But it seems to be important that the suture technique and strict follow-up in patients with diseased aortic wall.

  • PDF

소 대동맥 판막륜을 가진 대동맥판막 협착증 치험 1례 보고 (Aortic Valve Replacement with Patch Enlargement of Aortic Annulus in Aortic Stenosis with small aortic Annulus.)

  • 권오춘
    • Journal of Chest Surgery
    • /
    • 제18권4호
    • /
    • pp.663-666
    • /
    • 1985
  • Whatever a surgeon choose aortic prosthesis in aortic stenosis, it will always provoke some degree of obstruction to flow due to its smaller effective orifice area to tissue annulus. Occasionally, we meet small aortic annulus to his or her body surface area in aortic valve replacement. The small annulus remains a problem in that both tissue and mechanical prosthesis have significant pressure gradients between LV and aorta in resting or exercising states. In these circumstances, diverse surgical procedures, such as tilting disc prosthesis, supraannular position of aortic prosthesis, and enlargement of aortic root [including aortoventriculoplasty, translocation of aortic valve, & double outlet of LV by valved conduit], were applied. We experienced one case of aortic stenosis with small aortic annulus. Systolic pressure gradients between LV & aorta were 90 mmHg. Diameter of annulus was 19 mm. So we performed patch enlargement of aortic root by Manouguian and AVR with St. Jude medical valve 23 mm.

  • PDF

대동맥판을 보존한 대동맥근부치환술 - 증례보고 - (Aortic Root Replacement with Valve Preservation in a Patient with Annuloaortic Ectasia)

  • 김대준;윤치순;장병철
    • Journal of Chest Surgery
    • /
    • 제31권12호
    • /
    • pp.1234-1237
    • /
    • 1998
  • Marfan 증후군과 같은 대동맥 질환의 경우 대동맥동 및 대동맥륜의 점진적인 확장 및 변형이 발생하여 대동맥판막의 폐쇄부전을 초래한다. 이런 경우 대부분 상행대동맥과 대동맥 판막을 composite graft의 형태로 치환하고 여기에 관상동맥을 문합하는 술식이 적용되어왔다. 본 증례는 Marfan 증후군이 동반된 22세 남자 환자로 대동맥 근부 확장과 승모판막 부전이 있었다. 수술은 대동맥 판막 및 좌심실유출로의 일부를 보존하면서 상행대동맥 및 Valsalva동의 동맥류를 제거하고, 대동맥 판막 및 관상동맥을 인조혈관에 다시 문합하는 술식을 적용하였다. 술후 심초음파 검사상 대동맥 판막의 기능은 정상이었다. 대동맥륜 확장증에 있어서 대동맥 판막이 정상적인 해부학적 구조를 가진다면 이상의 술식을 적용함으로써 자신의 대동맥 판막은 보존하면서 대동맥 근부를 치환할 수 있으리라 생각된다.

  • PDF