Clinical Study of Prosthetic Heart Valve Replacement with CarboMedics. (CarboMEdics 기계판막을 이용한 심장판막 치환술의 임상 연구)

  • 장원기;구자홍;조중구;김공수
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.45-50
    • /
    • 2000
  • Background: The CarboMedics prosthetic heart valve was produced in an attempt to improve the existing valve designs and was especially concerned with easily the implantation and further reduction of turbulence. Precise positioning of the valve in situ was achieved by the abilityof the valve to rotate relative to the sewing ring. Improved monitoring is possible due to increased radiopacity and the dacron sewing ring is coated with carbon to reduce pannus overgrowth. The leaflets have an opening angle of 78 degrees that apparently allows a rapid synchronous closure The aim of this study was to analyze the clinical performance of the CarboMedics valve prostheses(45 mitral 13 aortic and 7 double aortic-mitral valve replacement) were implanted in 65 patients(mean age 48.75$\pm$9.74 years) Result: The operative mortality was 3.1%(2/65) causes of death were low cardiac output syndrome. Total follow up was 1831 patient-months and mean follow up was 29.06$\pm$10.97 months/patient. No structural failure hemorrhage valve thrombosis and late death have been observed. Embolism occurred at a rate of 0.65%/Patient-year. Actuarial survival and thrombo-mbolism free rate at 36 months were 96.9% and 98.4% respectively. Consclusions: The CarboMedics valve stands for low valve related complicatons.

  • PDF

Clinical study of myocardial preservation (심근보호에 대한 임상적 고찰)

  • Jo, Jae-Il;Lee, Yeong-Gyun
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 1984
  • Of the valve replacement patients operated between 1983 and June, 1984, 75 patients need more than 60 minutes of aortic cross-clamping time. 42 patients performed single valve replacement [35 MVR, 7 AVR with or without TAP] and remainder needs double valve replacement with or without TAP. The average aortic clamping time was 95.1 minutes. They need 30 minutes more extra-corporeal circulation time than aortic clamping time. The patients were divided into two groups by usage of cardioplegic solution. Group I [n=31] with Bretschneider solution and group II with potassium cardioplegic solution [M.G.H. modification] were analyzed by extra-corporeal circulation data,/CG and Echocardiography findings, and clinical data. There was no difference between two groups in Bivon addition amounts [cc/kg] and E.F. and S.F. by echocardiography, group I need 1 more electrocardioversion to convert sinus rhythm postoperatively. Also no difference could be found in patients whose preoperative C.I. was above 2.0 between two group. But significant postoperative decrease in E.F. was found in group I whose preoperative C.I. was below 2.0. Relatively longer ECC time was also needed in same group. Ischemic changes in ECG and low cardiac output syndrome was, however more prevalent in groupII. As a whole, the clinical data was satisfactory with both cardioplegic solution in clinical practice.

  • PDF

Postoperative Clinical Evaluation of Mechanical Valve Replacement (기계적판막의 임상적 고찰)

  • 송인기
    • Journal of Chest Surgery
    • /
    • v.21 no.1
    • /
    • pp.62-69
    • /
    • 1988
  • In the department of chest surgery of WonKwang university hospital, mechanical valve replacement was performed in 51 cases from June 1985 to September 1987. Among these, 32 cases were mitral valve replacement, 4 cases were aortic valve replacement, and 15 cases were double valve replacement. 26 cases were male and 25 cases were female and age distribution ranged from 16 years old to 63 years old. Early death within 30 days after operation was 2 cases [3.9%] and causes of death were right heart failure [1] and right ventricular wall rupture [1]. Among 49 early survivors, 2 cases of late death were developed and the causes of death were cardiomyopathy [1] and ventricular arrhythmia [1] Anticoagulant therapy was done with warfarin sodium to the level of 1.5-2 times of normal prothrombin time [20-40%] in 47 survivors. Symptomatically, 93.6% of preoperative NYHA functional class III or IV were converted to the NYHA functional class I or II during follow up.

  • PDF

Does Additional Aortic Procedure Carry a Higher Risk in Patients Undergoing Aortic Valve Replacement?

  • Kim, Tae-Hun;Park, Kay-Hyun;Yoo, Jae Suk;Lee, Jae Hang;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.45 no.5
    • /
    • pp.295-300
    • /
    • 2012
  • Background: With growing attention to the aortopathy associated with aortic valve diseases, the number of candidates for accompanying ascending aorta and/or root replacement is increasing among the patients who require aortic valve replacement (AVR). However, such procedures have been considered more risky than AVR alone. This study aimed to compare the surgical outcome of isolated AVR and AVR combined with aortic procedures. Materials and Methods: A total of 86 patients who underwent elective AVR between 2004 and June 2010 were divided into two groups: complex AVR (n=50, AVR with ascending aorta replacement in 24 and the Bentall procedure in 26) and simple AVR (n=36). Preoperative characteristics, surgical data, intra- and postoperative allogenic blood transfusion requirement, the postoperative clinical course, and major complications were retrospectively reviewed and compared. Results: The preoperative mean logistic European System for Cardiac Operative Risk Evaluation (%) did not differ between the groups: $11.0{\pm}7.8%$ in the complex AVR group and $12.3{\pm}8.0%$ in the simple AVR group. Although complex AVR required longer cardiopulmonary bypass ($152.4{\pm}52.6$ minutes vs. $109.7{\pm}22.7$ minutes, p=0.001), the quantity of allogenic blood products did not differ ($13.4{\pm}14.7$ units vs. $13.9{\pm}11.2$ units). There was no mortality, mechanical circulatory support, stroke, or renal failure requiring hemodialysis/filtration. No difference was found in the incidence of bleeding (40% vs. 33.3%) which was defined as red blood cell transfusion ${\geq}5$ units, reoperation, or intentional delayed closure. The incidence of mediastinitis (2.0% vs. 0%), ventilator ${\geq}24$ hours (4.0% vs. 2.8%), atrial fibrillation (18.0% vs. 25.0%), mean intensive care unit stay (34.5 hours vs. 38.8 hours), and median hospital stay (8 days vs. 7 days) did not differ, either. Conclusion: AVR combined with additional aortic or root replacement showed an excellent outcome and recovery course equivalent to that after isolated AVR.

Double valve replacement in Takayasu's disease -Report of one case- (Takayasu 동맥염에 동반된 심판막질환에서의 삼중판막수술 치험 1례)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.19 no.4
    • /
    • pp.688-694
    • /
    • 1986
  • Takayasu`s disease is an arteritis of unknown etiology involving larger elastic arteries such as aorta and its branches, pulmonary arteries and rarely coronary arteries. Especially, aortic root involvement with the valvular leaflets has been reported in several cases of Takayasu`s arteritis. Recently we have experienced one case of Takayasu`s arteritis involving left subclavian artery, descending aorta, left renal artery and multiple valvular leaflets. The patient was 33 year-old female and admitted with complaints of cough, dyspnea and general weakness. Aortogram revealed extensive type of arteritis showing dilatation of ascending aorta, segmental narrowing of thoracic aorta and Riolan`s anastomosis. Double valve replacement [mitral and aortic valve] and tricuspid valve annuloplasty were performed. The patient made an excellent postoperative recovery and has shown striking improvement in cardiac status, NYHA functional class II eight months after operation.

  • PDF

Clinical Experience of Carbomedics Prosthetic Heart Valve (Carbomedics 인조 심장판막의 임상적 경험)

  • Jeon, Sang-Hyeop;Kim, Jong-Won
    • Journal of Chest Surgery
    • /
    • v.28 no.9
    • /
    • pp.817-821
    • /
    • 1995
  • The CarboMedics Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism after it,s uses. The data for this study was collected from August 1988 to July 1993,five years period. There were total of 57 patients[female 40,male 17 in this series with 4 isolated aortic valve,26 isolated mitral valve,11 double valve and a triple valve replacement. The mean follow up time was 32 months. Postoperatively,58% of cases were in New York Heart Association[NYHA functional class I,and mild and moderate symptoms[NYHA class II were present in 36% and there were very few patients remaining in higher functional classes. In postoperative echocardiographic study, showed marked improved cardiac function. The overall early mortality was 3.5% and the late mortality was one case after triple valve replacement due to sudden death. The causes of early death were attributed to early prosthetic valve endocarditis and heart failure.

  • PDF

Infective Endocarditis Involving Aortic Valve, Mitral Valve, Tricuspid Valve, and luterventricular Septum -A Case Report (대동맥판막, 승모판막, 삼첨판막과 심실중격을 침범한 심내막염 -1예 보고-)

  • 박종빈;서동만
    • Journal of Chest Surgery
    • /
    • v.30 no.2
    • /
    • pp.200-204
    • /
    • 1997
  • This is a report of a successful management of a patient with infective endocarditis involving native aortic valve, mitral valve, tricuspid valve, and Interventric lar septum. A 16 year-old patient who underwent VSD patch closure, and aortic valvuloplasty at the age of 1 1 years showed Intractable congestive heart failure during antibiotics treatment for infective endocarditis. Operative findings revealed that there were large defect along the previous patch, aortic regurgitation with multiple perforations and vegetations, mitral regurgitation with vegetation, aortic paraannular abscess, interventricular myocardial abscess, and tricuspid regurgitation with perforations and vegetations. We reconstructed the interventricular defect with Dacron patch extending to the aortic valve annulus after radical debridement of all infected or devitalized tissues, and could implant aortic valve by anchoring to the reconstructed Dacron patch. Mitral valve was replaced and tricuspid valve was repaired with patient's own pericardium. The patient was discharged after antibiotics treatment for 6 weeks and in good condition without any sequelae for 12 months.

  • PDF

Low Contrast and Low kV CTA Before Transcatheter Aortic Valve Replacement: A Systematic Review

  • Spencer C. Lacy;Mina M. Benjamin;Mohammed Osman;Mushabbar A. Syed;Menhel Kinno
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.108-115
    • /
    • 2023
  • BACKGROUND: Minimizing contrast dose and radiation exposure while maintaining image quality during computed tomography angiography (CTA) for transcatheter aortic valve replacement (TAVR) is desirable, but not well established. This systematic review compares image quality for low contrast and low kV CTA versus conventional CTA in patients with aortic stenosis undergoing TAVR planning. METHODS: We performed a systematic literature review to identify clinical studies comparing imaging strategies for patients with aortic stenosis undergoing TAVR planning. The primary outcomes of image quality as assessed by the signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were reported as random effects mean difference with 95% confidence interval (CI). RESULTS: We included 6 studies reporting on 353 patients. There was no difference in cardiac SNR (mean difference, -1.42; 95% CI, -5.71 to 2.88; p = 0.52), cardiac CNR (mean difference, -3.83; 95% CI, -9.98 to 2.32; p = 0.22), aortic SNR (mean difference, -0.23; 95% CI, -7.83 to 7.37; p = 0.95), aortic CNR (mean difference, -3.95; 95% CI, -12.03 to 4.13; p = 0.34), and ileofemoral SNR (mean difference, -6.09; 95% CI, -13.80 to 1.62; p = 0.12) between the low dose and conventional protocols. There was a difference in ileofemoral CNR between the low dose and conventional protocols with a mean difference of -9.26 (95% CI, -15.06 to -3.46; p = 0.002). Overall, subjective image quality was similar between the 2 protocols. CONCLUSIONS: This systematic review suggests that low contrast and low kV CTA for TAVR planning provides similar image quality to conventional CTA.

A Clinical Study for Pre- and Intraoperative Risk Factors of Hospital Mortality after Mitral Valve Replacement (승모판막 치환술후 조기사망의 술전 및 술중 위험인자에 대한 임상적 고찰)

  • 박승규
    • Journal of Chest Surgery
    • /
    • v.23 no.2
    • /
    • pp.236-244
    • /
    • 1990
  • To improve the prognosis of mitral valve replacement surgery, analysis and evaluation of pre and intra operative risk factors will be very much valuable. Author studied 205 cases of mitral valve replacement from Feb 1982 to June 1989 for the risk factors of hospital death. 90 patients were male and 115 were female, and age was from 16 to 59 years, Mitral stenosis dominant lesions were 91 cases and regurgitation 114. Suspected risk factors were NYHA functional class, cardiothoracic ratio, implanted valve type and size, operation time, age and sex, thrombus in left atrium, atrial fibrillation, aortic cross clamping time, left ventricular end diastolic and systolic dimension, nephropathy, hepatopathy and respiratory insufficiency. Statistic analysis was performed by X2 test between survivors and death group. Statistical significances as pre and intraoperative risk factors of hospital death after mitral valve replacement were confirmed in those presence of AF on the EKG, NYHA functional class[>IV], cardiothoracic ratio[>70%], and implanted valve size[>33mm]

  • PDF

Clinical Study of Isolated and Combined Aortic Valve Replacement (대동맥판막치환술을 주(主)로 한 판막치환술의 임상성적)

  • 박동욱;황윤호;최강주;최석철;조광현
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.262-269
    • /
    • 1999
  • Background: To review the middle and long term results of aortic valve replacement(AVR) for 11 years, we surveyed and followed up the patients who underwent AVR. Material and Method: Between Feb. 1986 and May 1997, 134 patients underwent AVR. The patients consisted of 71 men and 63 women whose mean age was 38.9 years, ranging from 17 to 70. Result: The concomitant operations were 62 mitral valve replacement(MVR), 14 MVR + tricuspid valve annuloplasty, 10 Cabrol operation, 16 aortic annulus widening, and so forth. We used 119 mechanical(75 St. Jude Medical, 38 CarboMedics, 6 Sorin) and 15 tissue (Carpentier-Edwards) valves. Early postoperative complications occurred in 35 cases; 9 congestive heart failure, 6 low cardiac output, 5 postoperative bleeding, 5 pleural effusion, and so forth. There were 13 early postoperative deaths(9.7%) due to low cardiac output(5), CHF (2), disseminated intravascular coagulopathy(2), and so forth. The cumulative total follow-up period was 452.7 patient-years with a mean of 3.4${\pm}$3.1 years/patient. There were 9 cases of valve-related complications; anticoagulant-related bleeding(4), prosthetic valve endocarditis(2), thromboembolism(2) and prosthetic valve failure(1) occured at rate of 0.9, 0.4, 0.4, 0.2%/ pt-yr, respectively. Late valve-related death occurred in 3 cases(2.0%/pt-yr) associated with anticoagulant-related bleeding(2) and prosthetic valve endocarditis(1). Conclusion: Actuarial survival rate by Kaplan-Meier method was 91.0${\pm}$4.3 % at 11 years.

  • PDF