• Title/Summary/Keyword: Aorta, Surgery

Search Result 775, Processing Time 0.029 seconds

Aortoesophageal Fistula after Prosthetic Patch Aortoplasty for Mycotic Aneurysm of the Descending Thoracic Aorta (진균성 하행 흉부 대동맥류에서 인조 절편 대동맥 성형술 후 발생한 대동맥-식도 누공 -치험 1례 보고-)

  • 이홍섭
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.839-842
    • /
    • 2000
  • Aortoesophageal fistula is an uncommon and fatal complication after surgery of aortic aneurysm. A case of aortoesophageal fistula as a complication of synthetis patch aortoplasty for mycotic aneurysm of descending thoracic aorta is described. After 3 months since patch aortoplasty for mycotic aneurysm of descending thoracic aorta this patient visited the emergency room due to melena and hematemesis. After gastrofiberoscopy and computed tomography the patient was taken ot the operating room. The surgical intervention was performed in two steps. Median sternotomy and midline laparotomy were made. Hemashield's Dacron(16mm) bypass between ascending thoracic aorta and infra-renal abdominal aorta was established first. Through the posterolateral thoracotomy false aneurysm and previous Hemashield's Dacron patch of descending aorta were resected. The two ends of the aorta were sutured and esophageal fistula was repaired. The esophageal suture line and the stumps were covered with omental graft. Thirty months later the patient has had no difficulty referable to the aortic surgery.

  • PDF

Total Arch Replacement with Stented Elephant Trunk in DeBakey Type I Acute Aortic Dissection

  • Choi, Hyung-Yoon;Song, Suk-Won;Hong, Sun-Chang;Lim, Sun-Hee
    • Journal of Chest Surgery
    • /
    • v.46 no.1
    • /
    • pp.68-71
    • /
    • 2013
  • A 67-year-old female patient was treated with conventional total arch replacement and insertion of a stented elephant trunk (SET) graft into the descending thoracic aorta for acute DeBakey type I aortic dissection at one time. She had been treated with right coronary artery stent insertion for acute myocardial infarct 4 days earlier, and at that time, she was diagnosed with acute DeBakey type I aortic dissection from the ascending aorta to the suprarenal artery based on trans-esophageal echocardiography and aorta computed tomography. Through a median sternotomy, we inserted the SET graft through the opened aorta to the descending aorta. We also performed anastomosis between the proximal stented graft and the distal aortic arch, and then performed total arch replacement. For acute DeBakey type I aortic dissection, we report total arch replacement with insertion of a SET graft as a combination of conventional surgery and the interventional technique.

Short-term Outcomes of Aortic Wrapping for Mild to Moderate Ascending Aorta Dilatation in Patients Undergoing Cardiac Surgery

  • Park, Ji-Young;Shin, Je-Kyoun;Chung, Jin-Woo;Kim, Jun-Seok;Chee, Hyun-Keun;Song, Meong-Gun
    • Journal of Chest Surgery
    • /
    • v.45 no.3
    • /
    • pp.148-154
    • /
    • 2012
  • Background: The adequate management of mild to moderate dilatation of the ascending aorta during cardiac operations remains controversial. In this study, we present the short-term outcomes of 90 patients undergoing ascending aortic wrapping with a Dacron graft during other cardiac operations. Materials and Methods: From March 2008 to January 2011, 90 consecutive patients underwent treatment for ascending aortic aneurysm using the external wrapping technique during the concomitant procedure. The study group consisted of 49 male and 41 female patients with a mean age of $58.7{\pm}13$years. The primary cardiac surgical procedures were coronary artery bypass grafting (CABG) in 3, aortic valve replacement in 2, and aortic valvuloplasty in 85 patients (isolated in 62 and combined with CABG or mitral valvuloplasty in 23). The ascending aorta diameter was measured using a computed tomography scan within 4 weeks after surgery, and was compared with the preoperative value. Results: The diameters of the ascending aorta wrapped with the Dacron graft were significantly reduced within a month after surgery from $46.4{\pm}4.3$ mm to $33.0{\pm}3.5$ mm (p<0.05). There was no early mortality or major surgical complication. During the mean follow-up period of $15.4{\pm}5.2$ months, there was only one late death caused by septic multiorgan failure. Conclusion: Dacron wrapping of the ascending aorta offers excellent results with very low mortality and morbidity, and it can be regarded as a safe and effective method for the treatment of moderately dilated ascending aorta in selected patients.

Delayed Surgical Management of Traumatic Pseudoaneurysm of the Ascending Aorta in Multiple Trauma

  • Ma, Dae Sung;Kim, Sung Jin;Joo, Seok;Hyun, Sung Youl;Jeon, Yang Bin
    • Journal of Trauma and Injury
    • /
    • v.31 no.1
    • /
    • pp.29-33
    • /
    • 2018
  • Traumatic blunt aortic injury especially on proximal ascending aorta is a rare injury with a few reports. Generally emergency surgical management was performed. In this case, however, in multiple trauma with brain injury, emergency surgical management of aortic injury might result in unexpected secondary injury of the brain. Herein, we report a case of a 33-year-old man who was driving a truck was injured in a head-on collision. Evaluation revealed a pseudoaneurysm on his ascending aorta concomitant with epidural hemorrhage. He was treated by surgical management of his ascending aorta after 3 days from accident. There were no postoperative and neurologic complications and the patient was discharged after 18 days.

Floating Thrombus in the Ascending Aorta of the Patient with Systemic Sclerosis - A case report -

  • Lee, Sub;Cho, Jun-Woo;Kwon, Oh-Choon
    • Journal of Chest Surgery
    • /
    • v.44 no.1
    • /
    • pp.72-75
    • /
    • 2011
  • Aortic thrombi are important because it can cause the central and peripheral embolizations. Aortic thrombi can occur anywhere in the aorta but extremely rare in ascending aorta without atherosclerosis, aneurysm, cardiosurgical or traumatic state. Systemic sclerosis (SSc) is an autoimmune disorder of connective tissue and it can involve multisystem. Enhanced coagulation pathways, decreased fibrinolysis, and endothelial dysfunction probably contribute to vascular events in SSc. We report a case of a highly mobile thrombus in the ascending aorta, presented as an acute embolic stroke in the patient with systemic sclerosis. Surgical removal was performed to prevent recurrent embolic events.

Aortic Root and Ascending Aortic Aneurysm in an Adult with a Repaired Tetralogy of Fallot

  • Kim, Tae-Sik;Na, Chan-Young;Baek, Jong-Hyun;Yang, Jin-Sung
    • Journal of Chest Surgery
    • /
    • v.44 no.4
    • /
    • pp.292-293
    • /
    • 2011
  • Surgical repair of the tetralogy of Fallot is one of the most successful operations in the treatment of congenital heart diseases. We report the case of a 65-year-old man who had an aortic valve replacement at the time of complete repair of the tetralogy of Fallot at the age of forty-three. He subsequently had progressive aortic root and ascending aorta dilation to 9 cm. The aortic root and ascending aorta replacement was done using a composite valve-graft and was performed along with other procedures. Thus, meticulous follow-up of aortic root and ascending aorta after corrective surgery for tetralogy of Fallot is recommended following initial curative surgery.

Discrete coarctation of the aorta: report of a case (대동맥 축착증 1례 보고)

  • Hur, Y.;Ahn, W.S.;Yoo, B.H.;Kim, B.Y.;Chang, U.H.;Lee, J.H.;Yu, H.S.
    • Journal of Chest Surgery
    • /
    • v.15 no.3
    • /
    • pp.361-365
    • /
    • 1982
  • Coarctation of the aorta is a congenital constriction of the aorta of varying degree usually located slightly distal to the origin of the left subclavian artery. This congenital malformation is found at 5-9% of the congenital heart disease in Europe & North America, but in our country, it is reported as one of rare malformations. We present a case of coarctation of the aorta, which had double diaphragms as discrete form. This is 9 year-old boy, who has suffered from hypertensive symptoms since 6 years before. Coarctation of the aorta was confirmed by aortography, and there was no combined anomalies, and it was postductal type, and coarctations were consisted of two diaphragmatic webs at the both ends with a central aneurysmized. After resection of the coarctated segment completely, Woven Dacron graft was inserted with 18mm in diameter & 2.5cm in length successfully.

  • PDF

Delayed Diagnosis of Cardiac Tamponade That Was Caused by Intramural Hematoma of the Ascending Aorta -A case report- (상행대동맥 벽내 혈종에 의해 발생한 심낭 압전의 지연 진단 - 1예 보고 -)

  • Hwang, Yoo-Hwa;Song, Suk-Won;Yi, Gi-Jong
    • Journal of Chest Surgery
    • /
    • v.43 no.2
    • /
    • pp.194-198
    • /
    • 2010
  • Intramural hematoma of the aorta (IMH) is the precursor or a variant of a classic aortic dissection where hemorrhage occurs within the aorta wall in the absence of an initial intimal tear. IMH has a high rate of mortality and morbidity. The optimal therapy for IMH is uncertain, yet the involvement of the ascending aorta is usually considered as an indication for surgery due to the associated risk of rupture or cardiac tamponade. We report here on a case of a 71-year-old man who presented with syncope. Because of misdiagnosis, he underwent computed tomography (CT) after 5 hrs from arriving to the ER. Computed tomography of the aorta revealed intramural hematoma of the ascending aorta with cardiac tamponade. He also had vascular complications such as acute renal failure and visceral ischemia. We performed emergency graft replacement of the total arch and ascending aorta. He was discharged without complication on postoperative day 14.

Traumatic Intimal Tearing of the Descending Thoracic Aorta -A Case Report- (외상성 하행흉부대동맥 내막 파열 -치험 1예 보고-)

  • Chang, M.;Jang, J.S.;Kang, M.S.;Cho, B.K.;Hong, P.W.
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.269-273
    • /
    • 1980
  • The rupture of the aorta commonly follows major blunt trauma to the thorax. It has markedly increased in recent years, paralleling the rising number of vehicular accidents. The most frequent site of rupture is the area of the isthmus, with the ascending aorta second. The diagnosis of the condition from clinical data is difficult, and aortography is used whenever aortic tear is suspected. We are presenting a case of patient who had intimal tearing of the thoracic aorta with multiple injuries. The patient underwent surgical repair 28 days after injury with left heart [LA-Femoral artery] bypass.

  • PDF

Aortic Valve Replacement Using Balloon Catheter for Thoracic Endovascular Aortic Repair to Patient with Calcified Aorta

  • Kim, In Sook;Byun, Joung Hun;Yoo, Byung Ha;Kim, Han Yong;Hwang, Sang Won;Song, Yun Gyu
    • Journal of Chest Surgery
    • /
    • v.46 no.3
    • /
    • pp.212-215
    • /
    • 2013
  • A 79-year-old man was admitted to Samsung Changwon Hospital due to chest pain and dyspnea. The ejection fraction was 31% and mean pressure gradient between the left ventricle and aorta was 69.4 mmHg on echocardiography. Chest computed tomography showed severe calcification of the ascending aorta. Aortic valve replacement was successfully performed using a thoracic endovascular aortic repair balloon catheter without classic aortic cross clamping. The patient was discharged on the eleventh postoperative day.