• Title/Summary/Keyword: Antifreeze Coolant

Search Result 6, Processing Time 0.017 seconds

Study of Antifreeze Coolant for Fuel Cell System using the vehicle (연료전지 시스템 자동차용 부동 냉각액 연구)

  • Jo, Chang-Ryeol;Lee, Hong-Ki;Jeong, Jae-Hoon;Lee, Mi-Ji
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.205-208
    • /
    • 2007
  • We aim to develop antifreezing coolant used to in the 200kW Fuel Cell system that is possible to starting at low temperature and that must not to be freezed under $-30^{\circ}C$, have high coductivity, excellent system protection ability and durability.

  • PDF

Numerical Investigation of Cooling Performance of Liquid-cooled Battery in Electric Vehicles (하이브리드/전기 자동차용 수냉식 배터리 셀의 냉각성능에 관한 수치 해석적 연구)

  • Kwon, Hwabhin;Park, Heesung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.6
    • /
    • pp.403-408
    • /
    • 2016
  • Lithium-ion batteries are commonly employed in hybrid electric vehicles (HEVs), and achieving high energy density in the battery has been one of the most critical issues in the automotive industry. Because liquid cooling containing antifreeze is important in automotive batteries to enable cold starts, an effective geometric configuration for high-cooling performance should be carefully investigated. Battery cooling with antifreeze has also been considered to realize successful cold starts. In this article, we theoretically investigate a specific property of an antifreeze cooling battery system, and we perform numerical modeling to satisfy the required thermal specifications. Because a typical battery system in HEVs consists of multiple stacked battery cells, the cooling performance is determined mainly by the special properties of antifreeze in the coolant passage, which dissipates heat generated from the battery cells. We propose that the required cooling performance can be realized by performing numerical simulations of different geometric configurations for battery cooling. Furthermore, we perform a theoretical analysis as a design guideline to optimize the cooling performance with minimum power consumption by the cooling pump.

According to the type of commercial antifreeze experimental study of vehicle emissions (상용부동액 종류에 따른 자동차 배출가스의 실험적 연구)

  • Hong, Sung-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.4002-4006
    • /
    • 2014
  • The automotive exhaust gases generated by the vehicles containing carbon monoxide, hydrocarbons and lead, is a large concern because of their harm to human health or the living environment. To reduce exhaust gas, it is important to develop a variety of techniques that are currently being used by elemental analysis to determine the optimal conditions. In this study, the anti-freeze coolant contained in the exhaust gas was examined, which can affect the emissions. The effects of the commercially available coolant from five domestic companies on the HC, NOx and $CO_2$ emissions were analyzed to determine the optimal amount of antifreeze. In addition, antifreeze products from the five companies were analyzed with respect to driving time of the cooling fan and the correlation of the NOx emission analysis. The temperature of the engine oil was matched using a manual gear of small passenger inspection standard speed $40{\pm}2Km/h$ so the vehicle could meet the specifications for inspection $90{\sim}93^{\circ}C$. The Company D fan operation time resulted in the shortest antifreeze, $CO_2$ and NOx emissions.

Device Development of Mixture Concentration of Ethylene Glycol Antifreeze Coolant for Vehicles (자동차 에틸렌글리콜 부동액의 혼합 농도 측정 장치 개발)

  • Lee, Dae-Woong;Lee, Eun-Woung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.8
    • /
    • pp.331-336
    • /
    • 2016
  • This study presents a coolant density calculation device and its corresponding method by using a mass flowmeter and the LabVIEW program. The method can be easily measured with a mixture of coolant and by calculating the percentage of ethylene-glycol without additional investment. The cooling water is very important in a vehicle to protect the engine, and the cooling performance is affected by the mixture concentration and coolant density. The coolant density calculation device measures the mixed concentration in the anti-freeze cooling mixture made from distilled water and ethylene-glycol in real time with the mass flowmeter that is commonly attached to the radiator or heater core. The calculation program for the mixture concentration percentage was developed using the LabVIEW software. The correlation between experimental results and the calculation was conducted for a range of temperature from 40 to $90^{\circ}C$ and by varying the mixture ratio of distilled water and ethylene-glycol. As a result, the anti-freeze coolant concentration in the volume percentage is able to monitor the coolant density in a timely basis by implementing a mixture concentration calculation program without the need for additional equipment investment. The results of the calculation for the mixture concentration level show a maximum 2.7% deviation compared to the experimental results.

Automotive Engine Performance Analysis of antifreeze content and water type (부동액 함유량과 냉각수 종류에 따른 자동차 엔진 성능분석)

  • Hong, Sung-In
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1594-1599
    • /
    • 2015
  • The world car industry is in an era of internal combustion engines in the past 100 years of environmental, energy and IT is eco-friendly, high-tech cars technologies are bringing an era of change. Until now, the study of new technologies in automobile research and development has been focused on. The car's new technology development is also important, but it's cutting-edge technology is used in the car before the car's performance, and became an important point in the customer experience improvement problems. New technology development, as well as effective for existing technology applied is also important. This study was to determine the effects of temperature and the performance of automobile engine and determine the cause of the content in accordance with the type(tap water, distilled water, underground water) of anti-freeze and water that is contained in the automotive engine cooling water for the effective application of the anti-freeze. In the freezing point of the coolant -10, -20, -30, -40, $-50^{\circ}C$ dynamo performance test was conducted with the numerical analysis. Water (distilled water) were measured at the reference point peak performance 71.112, 99.622hp freezing $-10^{\circ}C$.

Effect of Coolant on PEMFC Performance in Low Humidification Condition (저가습 조건에서 냉각 유체의 고분자전해질 연료전지에 대한 영향)

  • Lee, Hung-Joo;Song, Hyun-Do;Kwon, Jun-Taek;Kim, Jun-Bom
    • Journal of the Korean Electrochemical Society
    • /
    • v.10 no.1
    • /
    • pp.25-30
    • /
    • 2007
  • Proton exchange membrane fuel cell(PEMFC) performance could be affected by various factors such as cell temperature, total pressure, partial pressure of reactants and relative humidity. Hydrogen ion is combined with water to form hydronium ion [$H_3O^+$] and pass through membrane resulting electricity generation. Cooling system is needed to remove heat and other uses on large scale fuel cell. In case that collant conductivity is increased, fuel cell performance could be decreased because produced electricity could be leaked through coolant. In this study, triple distilled water(TDW) and antifreeze solution containing ethylene glycol was used to observe resistance change. Resistance of TDW was taken 28 days to reach preset value, and effect on fuel cell operation was not observed. Resistance of antifreeze solution was not reached to preset value up to 48 days, but performance failure occurred presumably caused by bipolar plate junction resulting stoppage resistance experiment. Generally PEMFC humidification is performed near-saturated operating conditions at various temperatures and pressures, but non-humidifying condition could be applied in small scale fuel cell to improve efficiency and reduce system cost. However, it was difficult to operate large scale fuel cell without humidifying, especially higher than $50{\sim}60^{\circ}C$. In case of small flux such as 0.78 L/min, temperature difference between inlet and outlet was occurred larger than other cases resulting performance decrease. Non-humidifying performance experiments were done at various cell temperature. When both of anode and cathode humidification were removed, cell performance was strongly depended on cell operating temperature.