• Title/Summary/Keyword: Anti-vibration Rubber

Search Result 39, Processing Time 0.025 seconds

The Influence of Soft/Hard Segment Composition and Content on the Abrasion Resistance of Polyurethane Coating Agents (폴리우레탄 코팅제에 있어서 Hard Segment와 Soft Segment의 조성 및 함량변화가 내마모성에 미치는 영향)

  • Son, Hyung-Suk;Jeon, Dong-Geun;Park, Seong-Jin;Kim, Yong-Sung;Kwon, Kwi-Teag;Kim, Ki-Soo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.5
    • /
    • pp.5-12
    • /
    • 2014
  • Weatherstrip coatings of urethane and silicon type which are fit to EPDM and thermoplastic materials are used in sealing systems for automotive applications for noise reduction and high slip characteristics for external applications, respectively. Polyurethane binder was successfully synthesized from poly(butyladiphate)diol (PBAD), poly(tetramethylene)glycol (PTMG) and isocyanate as starting materials. Then, polyurethane coating agents were prepared by using various additives. To investigate effects of segment types on the abrasion resistance of polyurethane coating agents, thin films based on polyurethane coating materials were fabricated. With increasing the amount of hard segment in the coating agent, abrasion resistance, modulus and tensile strength of the coating films were improved, but the elongation of the coating films was decreased.

Optimum Design of Rubber Injection Molding Process for the Preparation of Anti-vibration Rubber (방진고무사출성형의 적정설계)

  • Lim, Kwang-Hee
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.490-498
    • /
    • 2010
  • The optimum mold design and the optimum process condition were constructed upon executing process simulation of rubber injection molding with the commercial CAE program of MOLDFLOW(Ver. 5.2) in order to solve the process-problems of K company relating to air-traps and short-shots. The former occurs at the cavity edge of torque-rod-bush and the latter takes place for the injection molding of dynamic dampers. As a result the process problem relating to air traps was solved by optimizing edge-angle and the number of gates to prevent the flow congestion of flow-front and to make the flow-front movement unaffected by congestion. For dynamic dampers of K company the unmolded flaw caused by their unfilled cavity was corrected by installing the air-vent at the confronting locations of both upstream and downstream of flow-front where air traps frequently occur. Besides the unmolded flaws were rectified by altering the position of gate from the upper to the middle or by increasing the number of gates. Thus the process problems of K company relating to air-traps and short-shots of torque-rod-bush and dynamic dampers, respectively, were solved by proper altering of mold design with process simulation of rubber injection molding.

Floor Impact Sound Isolation Performance by Composition of Ceiling and Wall (천장 및 벽구성 방법이 바닥충격음 차단성능에 미치는 영향에 관한 연구)

  • Kim Kyoung-Woo;Kang Jea-Sik;Lee Seung-Eon;Yang Kwan-Seop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.4 s.97
    • /
    • pp.465-473
    • /
    • 2005
  • The impact sounds, generated by the walking of people, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The characteristics and level of this impact noise depends on the object striking the floor, on the basic structure of the floor, and on the finish materials of floor. The focus of this paper is to investigate the amount of improvement impact sound pressure level according to the change of the composition method of ceiling and wall. For this purpose, we tested impact sound pressure level of several cases which is the inserting of mineral wool, the increase of the thickness of air layer, the using of anti-vibration rubber in ceiling and attach the mineral wool on wall in the Floor Impact Sound Test Building of KICT. The results show that the composition method of ceiling and wall is more effective in the reduction of light weight impact sound specially in 125Hz and 250Hz.

Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall (천장 및 벽구성 방법에 따른 바닥충격음 특성평가)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

Influence of the deteriorated anti-seismic devices on seismic performance and device behavior of continuous girder bridges

  • Shangtao Hu;Renkang Hu;Menggang Yang;Dongliang Meng
    • Earthquakes and Structures
    • /
    • v.24 no.5
    • /
    • pp.333-343
    • /
    • 2023
  • Various seismic isolation and reduction devices have been applied to suppress the longitudinal vibration of continuous girder bridges. As representative devices, lead rubber bearing (LRB) and fluid viscous damper (FVD) might suffer from deterioration during the long-term service. This study aims to evaluate the impact of device deterioration on the seismic responses of continuous girder bridges and investigate the seismic behavior of deteriorated LRBs and FVDs. Seismic performance of a simplified bridge model was investigated, and the influence of device deterioration was evaluated by the coefficient of variation method. The contribution of LRB and FVD was assessed by the Sobol global sensitivity analysis method. Finally, the seismic behaviors of deteriorated LRBs and FVDs were discussed. The result shows that (i) the girder-pier relative displacement is the most sensitive to the changes in the deterioration level, (ii) the deterioration of FVD has a greater effect on the structural responses than that of LRB, (iii) FVD plays a major role in energy dissipation with a low degradation level while LRB is more essential in dissipating energy when suffering from high degradation level, (iv) the deteriorated devices are more likely to reach the ultimate state and thus be damaged.

Analysis of Exciting Forces for In-Line 4 Cylinders Engine (직렬 4기통 엔진의 가진력 해석)

  • Kim, J.H.;Lee, S.J.;Lee, W.H.;Kim, J.R.
    • Journal of Power System Engineering
    • /
    • v.12 no.1
    • /
    • pp.41-46
    • /
    • 2008
  • The primary objective of this study is to truly understand exciting forces of the in-line 4 cylinders engine. Exciting forces of the engine apply a source of the vehicle NVH(Noise, Vibration, Harshness). To understand exciting forces, first was governed theoretical equations for single cylinder engine. And this theoretical equations was programming using MATLAB software. To compare theoretical analysis value, was applied MSC.ADAMS software. To determined the specification of engine(2,000cc, in-line 4) was applied ADAMS/Engine module. And this specification for engine was applied ADAMS/View and MATLAB software. The geometry model for ADAMS/View analysis was produced by the 3-D design modeling software. After imported 3-D model, each rigid body was jointed suitable. Under idle speed for engine, was analysed. The results of analysis are fairly well agreed with those of three analysis method. Using MATLAB software proposed in this study, engine exciting fores can be predicted. Also using ADAMS/Engine module and ADAMS/View software, engine exciting forces can be predicted.

  • PDF

Structure-borne Noise Reduction of Pump Machineries for Naval Ships (함정용 펌프류 장비의 고체음저감)

  • Kim, Hyeon-Sil;Kim, Jae-Seung;Gang, Hyeon-Ju;Kim, Sang-Ryeol
    • 연구논문집
    • /
    • s.29
    • /
    • pp.83-90
    • /
    • 1999
  • In naval ships, pump machineries are the major sources of airborne and structure-borne noise. Noise is critical issue in ships not only it causes annoyance to crews, but also it can increase the underwater radiated noise, which is crucial in anti-submarine warfare. In present study, it is discussed the reduction of structure-borne noise of pump machineries by showing several examples. The most typical and effective solution is to use double resilient mount system. However, in cases where double resilient system cannot be applied due to space and weight increase, rubber pad can be used to reduce the structure-borne noise. In principle, the concept of structure-borne noise reduction is the same as that of vibration isolation.

  • PDF

Analysis and Reduction Method of Noise from Head of a Combine Harvester (콤바인 전처리부의 소음 분석과 감소 방안)

  • Kim, Ho-Jung;Park, Young-Joon;Shim, Sung-Bo;Kim, Kyeong-Uk
    • Journal of Biosystems Engineering
    • /
    • v.32 no.3
    • /
    • pp.153-159
    • /
    • 2007
  • This study was conducted to measure and analyze the noise from a combine head. The combine head, comprised of a cutting knife assembly, pick-up chains, horizontally conveying chains and vertically conveying chains, had an overall sound level of 101 dBA. The sound levels of each component were, respectively, 98.3 dBA for the cutting knife assembly, 88.9 dBA for the pick-up chains, 79.8 dBA for the horizontally conveying chains and 86.3 dBA for the vertically conveying chains, being equivalent to 54.4%, 18.4%, 6.5% and 13.7% of the overall head noise. The main cause of the head noise was considered the impacts that the joint of the cutting knife assembly made with frame when it oscillated. The impact sound was also generated when the chain lug collided with the chain case. To reduce these impact sound, anti-vibration rubbers were installed on the knife assembly joint and the chain cases. It reduced the head noise by 4 dBA but the overall noise level of the combine head was still high. In order to protect the combine operators more effectively from the noise, a safety cab needs to be installed on the combine.

Static and Dynamic Behavior at Low-Frequency Range of Floating Slab Track Discretely Supported by Rubber Mounts in Real-Scale Laboratory Test (고무 마운트로 이산 지지되는 플로팅 슬래브 궤도의 실모형 실내 실험에서의 정적 및 저주파 대역 동적 거동)

  • Hwang, Sung Ho;Jang, Seung Yup;Kim, Eun;Park, Jin Chul
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.5
    • /
    • pp.485-497
    • /
    • 2012
  • Recently, with increasing social interests on noise and vibration induced by railway traffic, the application of floating slab track that can efficiently reduce the railway vibration is increasing. In this study, to more accurately understand the dynamic behavior of the floating slab track, a laboratory mock-up test has been performed, and the static and dynamic behaviors at frequency range near the system resonance frequency were explored. Based on the test results, the design of the floating slab track and the structural analysis model used in the design have been verified. The analytic and test results demonstrate that the dominant frequency of the floating slab track occurs at the frequencies between vertical rigid body mode natural frequency and bending mode natural frequency, and the dominant deformation mode is close to the bending mode. This suggests that in the design of the floating slab track, the bending rigidity of the slab and the boundary conditions at slab joints and slab ends should be taken into consideration. Also, the analytic results by the two-dimensional finite element analysis model using Kelvin-Voigt model, such as static and dynamic deflections and force transmissibility, are found in good agreement with the test results, and thus the model used in this study has shown the reliability suitable to be utilized in the design of the floating slab track.