• 제목/요약/키워드: Anti-Islanding Method

검색결과 68건 처리시간 0.064초

액티브 필터기능을 갖는 3상 태양광 발전시스템의 단독운전 방지기능의 분석 (Analysis results of the Anti-islanding Function for PV-AF System)

  • 김경훈;서효룡;장성재;박상수;박민원;유인근;전진홍;김슬기;조창희;안종보
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1085-1086
    • /
    • 2008
  • Shunt active filter can compensate harmonic current of utility results from non-linear loads such as rectifiers, cycloconverters and arc furnaces. It has the same structure as photovoltaic(PV) generation system. So, It was proposed the system that generates PV power and also has active filter function. It is called PV-AF(Photovoltaic and Active Filter) power generation system. Islanding can be occurred in an inverter based dispersed generation system, when the system disconnected from utility and loads are entirely supplied by PV system only. Islanding may result in interference to grid protection devices, equipment damage, and even personnel safety hazards. Therefore, islanding has to be detected and protected. The conventional anti-islanding methods have NDZ(None-Detection Zone) or power quality degradation. But PV-AF power generation system has the function of not only shunt active filter but also anti-islanding method without NDZ. In this paper, a novel anti-islanding method for PV-AF system is proposed and analysed in detail.

  • PDF

계통연계형 태양광발전 인버터를 위한 주기적인 영전류 구간을 가지는 새로운 AFD 단독운전 검출기법 (Novel AFD method of islanding detection with a periodic zero current for improving on islanding detection for grid-connected Photovoltaic inverters)

  • 고문주;최익;최주엽;송승호;이기옥
    • 한국태양에너지학회 논문집
    • /
    • 제26권4호
    • /
    • pp.17-23
    • /
    • 2006
  • This paper proposes a novel active frequency drift (AFD) method for the islanding prevention of grid-connected photovoltaic inverter. To detect the islanding phenomenon of grid-connected photovoltaic (PV) inverters concerning about the safety hazards and the damage to other electric equipments, many kinds of anti-islanding methods have been presented. Among them, AFD method using chopping fraction enables the islanding detection to drift up (or down) the frequency of the voltage during the islanding situation. In this paper, injecting the periodic zero current into the basic AFD method is proposed. This proposed method shows the analytical design value of cf to meet the test procedure of IEEE Std. 1547 with various load conditions. Detection of islanding is verified using simulation tool PSIM.

Positive Feedback을 이용한 무효전력 P&O 단독운전 검출기법 (Reactive Power P&O Islanding Detection Method using Positive Feedback)

  • 이종원;박성열;이재연;최세완
    • 전력전자학회논문지
    • /
    • 제27권5호
    • /
    • pp.410-416
    • /
    • 2022
  • A grid-connected inverter with critical loads uses mode transfer control to supply stable voltage to the load. An islanding detection method should also be used to quickly detect the grid fault and disconnect the inverter from the grid. However using the existing islanding detection method to detect islanding is difficult due to the small fluctuation of the voltage and frequency of the point of common coupling. This study proposes a reactive power P&O islanding detection method by using the positive feedback technique. The proposed method always injects a small variation of reactive power. When a grid fault occurs, the injected reactive power accelerates the reactive power injection reference. As a result, the reactive power reference value and the sensed reactive power become mismatched, and islanding is detected. Reducing the amount of real-time injected reactive power results in high efficiency and power factor. The simulation and experimental results of a 3 kW single-phase inverter are provided to verify the proposed islanding detection method.

정궤환을 이용한 무효전력 변동기반의 단독운전 방지 성능 검증 (Performance Verification of Anti-Islanding of Reactive Power Variation Method using Positive Feedback)

  • 조종민;신창훈;차한주
    • 전력전자학회논문지
    • /
    • 제24권2호
    • /
    • pp.105-110
    • /
    • 2019
  • This study proposed a reactive power variation (RPV) method equipped with positive feedback (PF) for detecting the islanding operation of distributed generation systems. The proposed RPV consists of the constant reactive power component and a certain reactive power term and uses the frequency deviation between the rated and the measured frequencies. The constant reactive power is injected from distributed generation system and power factor is to 0.9975 in grid-connected operation. PF is activated from generation of the frequency deviation and the injected reactive power is continuously increased due to PF when islanding occurs. Consequently, the increasing reactive power causes the point of common coupling frequency to deviate from the maximum/minimum threshold level. Performance of the proposed RPV is verified in a 1.7 kW T-type inverter, and the detection times are 53 and 150 ms.

계통연계형 PV 인버터의 자동 위상 이동법에 의한 고립운전 검출 (Islanding detection of grid-connected photovoltaic inverters using Automatic phase-shift method)

  • 윤중혁;김흥근;최종우;전태원;이홍희
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.591-594
    • /
    • 2005
  • Islanding of PV systems occurs when the uitilty grid is removed but local sources continue to operate and provide power to local loads. Islanding Is one of the serious problems in an electric power system connected with dispersed power sources. Also, this scan present safety hazards and the possibility of damage to other electric equipments. If the real and reactive power of RLC load and PV system are closely matched, islanding phenomena can't be detected by the passive methods. Several active methods were proposed to detect islanding phenomena. The most effective method is SFS method which was suggested by Sandia National Laboratory. In this paper, a new anti-islanding algorithm is proposed and its validity is verified through simulation and experimental results for utility interconnection of PV system.

  • PDF

3상 계통연계형 태양광 PCS의 단독운전검출을 위한 개선된 무효전력변동기법 (Improved RPV(reactive-power-variation) anti-islanding method for grid-connected three-phase PVPCS)

  • 이기옥;정영석;소정훈;유병규;유권종;최주엽;최익
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1159-1160
    • /
    • 2006
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, this has raised potential problems of network protection on electrical power system. One of the numerous problems is an Island phenomenon. There has been an argument that because the probability of islanding is extremely low it may be a non-issue in practice. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an island can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficient to cause a trip, plus the time required to execute the trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. And, third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an island. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. So the verification of anti-islanding performance is strongly needed. In this paper, the authors propose the improved RPV method through considering power quality and anti-islanding capacity of grid-connected three-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation and experimental results are verified.

  • PDF

주기적 위상 변동 기법을 이용한 새로운 단독운전 검출 기법 (Novel Anti-islanding method using phase shift with a periodic function)

  • 정영석;최재호;소정훈;유병규;유권종
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.1153-1154
    • /
    • 2006
  • This paper proposes the optimal design method based on NDZ analysis to secure the islanding defection ability and to maintain the stability and power quality when the grid is connected. A PSiM-based model and analysis of the system is presented, specialty aimed at improving the effectiveness of phase shift anti-islanding method with frequency feedback, which causes the inverter current to be generated slightly lower or higher in frequency than the frequency of the terminal voltage. The proposed method can cause frequency jump with leading and lagging phase of output current in two line cycles. As a result, the proposed algorithm is more sensitive and reliable than the conventional phase shift method. Experimental results, on a 3 kW inverter connected to 220 V, 60 Hz utility, are discussed.

  • PDF

Digital PLL을 이용한 Active Frequency Drift Positive Feedback에 관한 연구 (Active Frequency Drift Positive Feedback Method for Anti-islanding applied Digital Phase-Locked-Loop)

  • 이기옥;최주엽;최익;정영석;유권종;송승호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.250-254
    • /
    • 2007
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive powers of the load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

  • PDF

디지털 위상검출기법을 적용한 능동적 주파수 변화 정궤환기법 (Active Frequency Drift Positive Feedback Method for Anti-islanding using Digital Phase-Locked-Loop)

  • 이기옥;정영석;최주엽;최익;송승호;고문주
    • 한국태양에너지학회 논문집
    • /
    • 제27권2호
    • /
    • pp.37-44
    • /
    • 2007
  • As photovoltaic(PV) power generation system becomes more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of the load and PV system are closely matched, islanding detection by Passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

전향보상 전압의 위상 변화를 통한 단독운전 검출 방법의 계통 정상 상태의 성능 평가 (Performance Evaluation of Islanding Detection Method by Phase Shifted Feed-Forward Voltage in Steady-State Grid Condition)

  • 김동욱;김성민
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.373-380
    • /
    • 2018
  • This study proposes a new islanding detection method that uses the phase shift of feed-forward voltage and evaluates the performance of an existing method and the proposed method when the grid frequency changes within the allowable range under steady-state conditions. The investigated existing method, which is slip mode frequency shift (SMS), uses current phase shift to detect islanding. The SMS method supplies reactive current to the grid under this condition, but the proposed method does not generate additional reactive power because it does not depend on the current control loop. The performance in steady-state grid condition is evaluated through simulations and experiments.