• Title/Summary/Keyword: Anti-Coincidence

Search Result 11, Processing Time 0.021 seconds

GENERALIZED ANTI FUZZY SUBGROUPS

  • Jun, Young-Bae;Song, Seok-Zun
    • East Asian mathematical journal
    • /
    • v.22 no.2
    • /
    • pp.195-205
    • /
    • 2006
  • Using the notion of anti fuzzy points and its besideness to and non-quasi-coincidence with a fuzzy set, new concepts of an anti fuzzy subgroup are introduced and their inter-relations are investigated.

  • PDF

Cross Talk Experiment with Two-element CdTe Detector and Collimator for BNCT-SPECT

  • Manabe, Masanobu;Ohya, Ryosuke;Saraue, Nobuhide;Sato, Fuminobu;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.328-332
    • /
    • 2016
  • Background: Boron Neutron Capture Therapy (BNCT) is a new radiation therapy. In BNCT, there exists some very critical problems that should be solved. One of the severest problems is that the treatment effect cannot be known during BNCT in real time. We are now developing a SPECT (single photon emission computed tomography) system (BNCT-SPECT), with a cadmium telluride (CdTe) semiconductor detector. BNCT-SPECT can obtain the BNCT treatment effect by measuring 478 keV gamma-rays emitted from the excited state of $^7Li$ nucleus created by $^{10}B(n,{\alpha})$ $^7Li$ reaction. In the previous studies, we investigated the feasibility of the BNCT-SPECT system. As a result, the S/N ratio did not meet the criterion of S/N > 1 because deterioration of the S/N ratio occurred caused by the influence of Compton scattering especially due to capture gamma-rays of hydrogen. Materials and Methods: We thus produced an arrayed detector with two CdTe crystals to test cross talk phenomenon and to examine an anti-coincidence detection possibility. For more precise analysis for the anti-coincidence detection, we designed and made a collimator having a similar performance to the real BNCT-SPECT. Results and Discussion: We carried out experiments with the collimator to examine the effect of cross talk of scattering gamma-rays between CdTe elements more practically. As a result of measurement the coincidence events were successfully extracted. Conclusion: We are now planning to carry out evaluation of coincidence rate from the measurement and comparison of it with the numerical calculations.

Design and Experiment on the Portable Gamma-Ray Pipe Thickness Gauge (휴대용 감마선파이프측후도의 설계와 시작)

  • 김덕진;김홍식
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.4 no.2
    • /
    • pp.3-15
    • /
    • 1967
  • In the design of a portable Gamma-ray transistorized steel pipe thickness gauge, a pulse height discriminator and an anti-coincidence circuit could be eliminated by using a thin, less than 1/2inch, NaI(Tl) scintillation crystal in the detecting probe. This method could provide an economic design and fabrication of a gamma-ray back-scattering gauge allowing allmost the same accuracy and stability compared with the exsisting method. A gauge had been designed and fabricated with the above method and its accuracy was experimentall tested for the 200$^{\circ}C$ high temperature steel pipes. The result showed that the thermal drift was less than y percent which was acceptabel in the practical applications.

  • PDF

Study in Background Reduction for the Neutron Induced Prompt Gamma-ray Spectroscopy

  • Song, Byoung-Chul;Jee, Kwang-Yong;Park, Yong-Joon
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.433-433
    • /
    • 2004
  • Neutron induced prompt gamma-ray spectroscopy (NIPS) system measures the prompt gamma-ray, emitting by the interaction of a neutron with various materials. This system will be of great benefit to scientists worldwide, since it provides the non-destructive measurement of many elements in either solid or liquid wastes. A NIPS facility has been developed in Nuclear Chemistry Research Division, at Korea Atomic Energy Research Institute (KAERI) with the aim of analyzing the major component elements in both aqueous and solid samples.(omitted)

  • PDF

X-선 검출기의 신호처리회로 설계

  • 남욱원;최철성;문신행
    • Bulletin of the Korean Space Science Society
    • /
    • 1993.10a
    • /
    • pp.23-23
    • /
    • 1993
  • 과학로케트에 탑재되는 x-선 검출기에서 검출되는 2 kev 에서 10 kev 사이의 x-선 신호를 분석하여 데이터를 얻고, 전송하기 위한 피로를 설계하고 제작하였다. 신호처리회로의 전체적인 구성은 2 - 10 key의 x-선 에너지 및 event time을 측정하는 회로 및8-선 계수율을 측정하기 위한 카운터회로를 위주로 설계하였으며, x-선 event의 에너지가 측정에너지를 벗어나거나 상승시간이 긴 신호는 anti-coincidence 회로를 통하여 제거되고, 그 계수율이 기록되도록 설계 제작되었다. 또한 신호처리회로에서 얻은 데이터는 telemetry를 통하여 serial 형태로 전송되어야 하므로 8086 microprocessor를 이용하여 데이터를 획득하고 전송하도록 하였다. 따라서 본 실험에서 제작된 신호처리회로의 기능 및 특성에 대해 논하고자 한다.

  • PDF

A MONTE CARLO SIMULATION FOR THE X-RAY DETECTION EFFICIENCY OF A MULTI-CELL PROPORTIONAL COUNTER (다중셀 비례계수기의 X-선 검출효율에 대한 수치모의 실험)

  • 이기원;최철성;남욱원;선광일
    • Journal of Astronomy and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.341-358
    • /
    • 1998
  • The X-ray astronomy team of the Korea Astronomy Observatory(KAO) is planning to develop a multi-cell proportional counter, adopting an anti-coincidence method to reduce its internal background. We have developed a Monte Carlo code to determine the X-ray detection efficiency of the counter. As a check of our code, we successfully reproduced the detection efficiency of Ginga/LAC. In this paper, we report the simulation results for the counter being considered in KAO.

  • PDF

Carol Christian Poell's Art Works from a Fluxus Perspective -Focused on the Comparison with Nam June Paik's Performance- (플럭서스 관점에서 본 캐롤 크리스찬 포엘(Carol Christian Poell)의 작품세계 -백남준의 퍼포먼스와의 비교를 중심으로-)

  • Hong, Junyoung;Chun, Jaehoon
    • Fashion & Textile Research Journal
    • /
    • v.22 no.3
    • /
    • pp.296-309
    • /
    • 2020
  • Carol Christian Poell is a designer famous for experimental designs and presentations. Poell's actions in the fashion-world resemble Fluxus, an anti-art group that started working in the 1950s. This study analyzed the works of Poell based on the characteristics of Fluxus and then compared the works of Poell with the performance of Nam June Paik, a Fluxus artist. We conducted literature studies and case studies. We examined the works of Poell and Paik based on the four characteristics of Fluxus: iconoclasm, unity of art and life, playfulness and chance. The results were as follows. First, they were engaged in anti-aesthetic works. While Paik concentrated on the content aspect of works, Poell was more focused on formal aspects. Second, neither of them distinguished between art and life. Paik achieved it by including audiences in his works; however, Poell attained it by adopting daily spaces as a place to display presentations and use ready-made forms. Third, they showed playfulness with a satirical nuance. Paik expressed it in an erotic way; however, Poell implied it through the irrational settings of circumstance. Finally, they created works by utilizing chance. Paik focused on auditory elements and the content aspects of works; however, Poell used the coincidence of visual and tactile elements when creating his works. This study compared the works of Poell with Paik and has its significance in its usefulness to understand designers with Fluxus characteristics in the fashion industry.

A study on the reduction of noise and vibration by acoustic resonance in the tube bank of a circulating fluidized bed combustion boiler (순환 유동층 보일러 관군의 음향공진에 의한 이상소음 발생 및 저감 연구)

  • Park, Eung-Kyu;Song, Keun-Bok;Kim, Won-Hyun;Joo, Won-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.101-106
    • /
    • 2011
  • In the present paper, the phenomena of abnormal noise and vibration due to acoustic resonance of CFBC(Circulating Fluidized Bed Combustion) boiler was presented. The acoustic resonance which occurred in the gas path of CFBC boiler system was caused by coincidence of vortex shedding frequency of tube bank and acoustic natural frequency of duct and hopper. And, the phenomena of beating arose from the interference of two closed resonant waves at 66.4Hz and 70.8Hz. There are two control methods for acoustic resonance in this system. The first method is to change the vortex shedding frequency from the structural alterations on the tube bank. And the second method is to change the acoustic natural frequency of the gas path with the installation of anti-noise baffles. The second one which is relatively easy to apply, was adapted in this study. As a result, the noise and vibration level have been decreased by 41dB and 94% at 66.4Hz, respectively. And the improvement of noise and vibration at 70.8Hz was identified by sensory evaluation.

  • PDF

Development of Competitive Indirect ELISA for the Detection of Buckwheat in Processed Foods (가공식품 중 메밀 검출을 위한 경합 ELISA의 개발)

  • Back, Su-Yeon;Do, Jeong-Ryong;Shon, Dong-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.46 no.3
    • /
    • pp.269-275
    • /
    • 2014
  • We developed a competitive indirect enzyme-linked immunosorbent assay (ciELISA) for determining the buckwheat content in processed foods by using rabbit polyclonal antibodies against buckwheat proteins (BWP). The detection limit of this assay was $0.05-100{\mu}g/mL$. The cross-reactivities of the anti-BWP antibodies toward BWP, buckwheat flour, whole buckwheat, and cereals (wheat flour, whole wheat, black bean, mung bean, red bean, brack rice, brown rice, glutinous rice, white rice, millet, African millet, nonglutinous millet, adlay, and rye) were 100, 17.9, 11.8, and 0%, respectively. Thus, the antibodies were found to be specific for buckwheat only. When buckwheat flour was heated for 30 min, the mean assay recoveries of BWP were 83.0% at $60-90^{\circ}C$ and 44.5% at $100^{\circ}C$. The spike test showed that the mean assay recoveries of buckwheat from raw noodle, boiled noodle, starch gel, and cereal flour were 99.1, 98.6, 81.1, and 104%, respectively. For the 22 commercial items tested, the qualitative coincidence ratio of assay result and the corresponding value indicated on the item's package label was 100%. However, the average quantitative coincidence ratios from 12 commercial items were 31.6%. Thus, the results suggest that ciELISA is an efficient tool to detect buckwheat in processed foods.

Development of Anticosmic Shielded Ultra Low Background Gamma Spectrometer for Precise Measurement of Environmental Radioactivity

  • Byun, Jong-In;Park, Yun-Ho;Kwak, Seung-Im;Hwang, Han-Yull;Chung, Kun-Ho;Park, Gun-Sik;Park, Doo-Won;Lee, Chnag-Woo
    • Nuclear Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.545-552
    • /
    • 2002
  • We developed an ultra low background gamma ray spectrometer particularly suitable for experiment which require lower detection limit. The background of a germanium spectrometer is suppressed by applying active and passive shielding technique at the same time. The active shielding devices consist of plastic scintillating plates of 50 mm thick and anti-coincidence electronic system. The shielding is made of 150 mm thick walls of very low activity lead,20 mm with activity of <10 Bq/kg and 130 mm with activity of <50 Bq/kg. The observed background count rates are 1.2 $s^{-1}$ and 0.36 $s^{-1}$ without and with the active shielding, respectively, overall the energy regions from 30 keV to 3 MeV The cosmic ray induced background is suppressed by a rate of 0.8 $s^{-1}$ at the present work. The detection efficiency curve necessary to obtain the radioactivity of environmental samples has been precisely determined on the energy regions from 80 to 2000 keV with a 10$^3$ ml marinelli beaker sample, consisting of the calibrated radionuclides $^{109}$ Cd, $^{57}$ CO, $^{139}$ Ce, $^{203}$ Hg, $^{113}$ Sn, $^{85}$Sr, $^{137}$ Cs, $^{60}$ Co and $^{88}$ Y. Virtues Of the method are demonstrated by measuring the activity of $^{137}$ Cs contained in the powdered milk.