• 제목/요약/키워드: Anterior loop

검색결과 41건 처리시간 0.027초

전치부 Open-bite의 치험일례 (A CASE REPORT OF ANTERIOR OPEN-BITE)

  • 장상헌;이미대;남동석;양원식;조희원
    • 대한치과의사협회지
    • /
    • 제13권9호
    • /
    • pp.823-828
    • /
    • 1975
  • We have effectually treated 22 years girl who had complained of an aterior open-bite. Treatment was based on non-extracted and multibanded technigue at the use of horizontal loop with 0.016 inch green Elgiloy wire. Anteior cross elastics, C1Ⅲ intermaxillary elastics, occasicnally C1.Ⅱ elastics were used. when vertical discrepancy was corrected, we changed the arch wire making use of 0.018 ×0.022 inch rectangular wire with 1st. and 2nd. order bend. After 12mons. the ideal arch wire with tie back loop was placed for stabilizing arch. Nearly after 20 months bands were removed and placed retainer.

  • PDF

상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구 (The pattern of movement and stress distribution during retraction of maxillary incisors using a 3-D finite element method)

  • 정애진;김운수;이수행;강성수;최희인;조진형;김상철
    • 대한치과교정학회지
    • /
    • 제37권2호
    • /
    • pp.98-113
    • /
    • 2007
  • 상악 전치부 후방 견인 시의 이동 양상 및 응력 분포를 건조 두개골을 전산화 단층 촬영에 의해 3차원 영상화한 유한 요소 모델 상에서 알아보고자 하였다. 피질골 절단술의 시행 여부와 고정원, 힘의 작용점을 각기 달리 설정하여 8개의 실험군을 구성하여 비교하였다. 통상적인 T-loop을 이용하여 공간폐쇄를 하는 경우 전치부는 후하방으로 경사이동 하였으며, 구치부에서도 약간 전방 이동하였다. 피질골 절단술을 동반하여 전치부를 견인한 경우, 전치부 골편에서의 응력 분포가 전반적으로 넓게 분포되었으며, 전치부 경사의 정도가 적은 반면에 변위량은 훨씬 더 많았다. 협측에서의 견인 시 상악 협측에 식립된 미니 임플랜트와 견치 Power arm간에 견인력을 가한 경우가 미니 임플랜트로 고정원이 강화된 제2소구치와 견치 브라켓 간에 견인력을 가한 경우보다 전치부의 후하방 경사 정도가 적었다. 구개측에서 Powerarm에 대한 견인 시 정중구개봉합 부위에 식립한 미니 임플랜트로부터 견인력을 가한 경우가 상악 제1, 2대구치 간 구개면에 식립된 미니 임플랜트로부터 견인력을 가한 경우보다 전치부의 후하방 경사 정도가 컸다. 이러한 결과로써 치아이동 시 피질골 절단술의 효과와 저항중심에 대한 교정력 벡터 조정의 의미를 확인할 수 있었다.

Prevalence and extension of the anterior loop of the mental nerve in different populations and CBCT imaging settings: A systematic review and meta-analysis

  • Hadilou, Mahdi;Gholami, Leila;Ghojazadeh, Morteza;Emadi, Naghmeh
    • Imaging Science in Dentistry
    • /
    • 제52권2호
    • /
    • pp.141-153
    • /
    • 2022
  • Purpose: This study aimed to identify the prevalence and extension of the anterior loop (AL) of the mental nerve in different populations and according to different cone-beam computed tomography (CBCT) imaging settings. Materials and Methods: Medline/PubMed, Embase, Scopus, Web of Science, and ProQuest were searched. The main inclusion criterion was ALs evaluated in CBCT images. The quality of studies was assessed with the Joanna Briggs Institute risk of bias checklist. Subgroup analyses were conducted for sex, side, continent, voxel size, field of view, and type of CBCT-reconstruction images with a random-effects model. Results: Sixty-three studies with 13,743 participants (27,075 hemimandibles) were included. An AL was found in 40.6% (95% CI: 32.8%-48.9%, P<0.05) of participants and 36.0% (95% CI: 27.5%-45.5%, P<0.05) of hemimandibles, in 34.9% (95% CI: 25.1%-46.2%, P<0.05) of males and 34.5% (95% CI: 23.5%-47.4%, P<0.05) of females. The average length of ALs was 2.39 mm (95% CI: 2.07-2.70 mm, P<0.05). Their extension was 2.13 mm (95% CI: 1.54-2.73 mm, P<0.05) in males and 1.85 mm (95% CI: 1.35-2.36 mm, P<0.05) in females. Significant differences were observed regarding the prevalence and length of ALs among continents and for its measured length on different CBCT-reconstruction images, but not between other subgroups. Conclusion: AL was a relatively common finding. The voxel size and fields of view of CBCT devices were adequate for assessing AL; however, a 2-mm safety margin from anatomical structures(such as the AL) could be recommended to be considered when using CBCT imaging.

산모에서 요부 경막외 차단후 발생한 편측 호너 증후군과 상지마비 -증례 보고- (Unilateral Horner's Syndrome and Upper Extremity Paralysis following Lumbar Epidural Block in a Obstetric Patient)

  • 장연;조은정;김정태;박수석;이재희
    • The Korean Journal of Pain
    • /
    • 제10권2호
    • /
    • pp.285-290
    • /
    • 1997
  • Horner's syndrome is a well-recognized complication of regional analgesia of neck and shoulder region, and not often a complication of lumbar or low thoracic epidural block. Recently we experienced right Horner's syndrome accompanying paralysis of right upper extremity following lumbar epidural block in for an obstetric patient. Epidurography and MRI was performed to clarify the cause of unilateral high epidural block and cervical sympathetic block. Radiologic study demonstrated a loop formation of the epidural catheter and tip of catheter was located in right anterior epidural spaced(L1-2). The initial epidurogram revealed unilateral spreading of dye in the cervical region in right epidural space. A second epidurogram, 10 minutes following, showed dye filling in left epidural space, however spread of dye in left side was limited to lumbar and low thoracic region. We concluded the most probable cause of this unilateral high epidural block was due to misplacement of the catheter into the anterior epidural space.

  • PDF

The Consequences of Mutations in the Reproductive Endocrine System

  • Choi, Donchan
    • 한국발생생물학회지:발생과생식
    • /
    • 제16권4호
    • /
    • pp.235-251
    • /
    • 2012
  • The reproductive activity in male mammals is well known to be regulated by the hypothalamus-pituitary-gonad axis. The hypothalamic neurons secreting gonadotropin releasing hormone (GnRH) govern the reproductive neuroendocrine system by integrating all the exogenous information impinging on themselves. The GnRH synthesized and released from the hypothalamus arrives at the anterior pituitary through the portal vessels, provoking the production of the gonadotropins(follicle-stimulating hormone (FSH) and luteinizing hormone (LH)) at the same time. The gonadotropins affect the gonads to promote spermatogenesis and to secret testosterone. Testosterone acts on the GnRH neurons by a feedback loop through the circulatory system, resulting in the balance of all the hormones by regulating reproductive activities. These hormones exert their effects by acting on their own receptors, which are included in the signal transduction pathways as well. Unexpected aberrants are arised during this course of action of each hormone. This review summarizes these abnormal phenomena, including various mutations of molecules and their actions related to the reproductive function.

Open Loop Responses of Posture Complexity in Biomechanics

  • Shin, Youngkyun;Park, Gu-Bum
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.42-50
    • /
    • 2013
  • The reactionary responses to control human standing dynamics were estimated under the assumption that postural complexity mainly occurs in the mid-sagittal plane. During the experiment, the subject was exposed to continuous horizontal perturbation. The ankle and hip joint rotations of the subject mainly contributed to maintaining standing postural control. The designed mobile platform generated anterior/posterior (AP) motion. Non-predictive random translation was used as input for the system. The mean acceleration generated by the platform was measured as $0.44m/s^2$. The measured data were analyzed in the frequency domain by the coherence function and the frequency response function to estimate its dynamic responses. The significant correlation found between the input and output of the postural control system. The frequency response function revealed prominent resonant peaks within its frequency spectrum and magnitude. Subjects behaved as a non-rigid two link inverted pendulum. The analyzed data are consistent with the outcome hypothesized for this study.

First Record of the Genus and Species, Thetys vagina (Thaliacea: Salpida: Salpidae) in Korea

  • Seo, Su Yuan;Kim, Sun Woo;Won, Jung Hye
    • Animal Systematics, Evolution and Diversity
    • /
    • 제36권3호
    • /
    • pp.236-239
    • /
    • 2020
  • Pelagic tunicate, Thetys vagina Tilesius, 1802, is newly reported from Korean waters. The genus Thetys Tilesius, 1802 is also first recorded as Korean fauna. Thetys vagina is the only valid species in the genus Thetys. It is distinct from other genera by having at least 16 body muscles widely interrupted, no anterior proboscis, bent alimentary canal in the solitary oozooid, and five narrow body muscles, no ventral peduncle, an almost compact loop alimentary canal in the aggregate blastozooids. The specimens of T. vagina examined in this study were collected at the subtidal zone of Ulleung-do Island by scuba diving. In this paper, the detailed descriptions and photographs of both the solitary and aggregate living forms of T. vagina are provided.

단순악간고정법을 이용한 양측성 하악과두골절의 보존적 치료 (CONSERVATIVE TREATMENT OF BILATERAL CONDYLAR FRACTURE BY A SIMPLIFIED TECHNIQUE OF MAXILLOMANDIBULAR FIXATION)

  • 김종필
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제17권2호
    • /
    • pp.171-179
    • /
    • 1995
  • The conservative treatment of the condylar fracture has been used for a long time because of its simplicity, good prognosis and less complication. Traditionally the conservative treatment has been carried out by maxillomandibular fixation using arch bar and wire. But a simplified technique of maxillomandibular fixation introduced here is a procedure that 4 bone screws are placed above the apecies of the maxillary and mandibular canines and then ipsilaterally placed maxillary and mandibular bone screws are linked by a loop of wire each other. This procedure has several advantages compared with the traditional maxillomandibular fixation method. 1) it provides simplicity for the operators. 2) it sustains maxillomandibular fixation more rigidly compared with arch bar technique. 3) it keeps stable maxillomandibular fixation in the region of the anterior teeth so that anterior open bite tendency can be remarkably minimized. 4) it does not injure the periodontal tissue because the teeth are not engaged and causes less discomfort to the patient. 5) it decreases the possibility of operator's AIDS infection through inadvertent skin puncture. 6) it is highly recommended for the patients whose teeth are available for maxillomandibular fixation. The two male patients were diagnosed as bilateral condylar and symphyseal fracture of the mandible. They restored stable occlusion and functional mandibular movement only by a simplified technique of maxillomandibular fixation.

  • PDF

Chronic Gastric Volvulus with Laparoscopic Gastropexy after Endoscopic Reduction: A Case Report

  • Lee, Hye Yeon;Park, Jung Hyun;Kim, Sung Geun
    • Journal of Gastric Cancer
    • /
    • 제15권2호
    • /
    • pp.147-150
    • /
    • 2015
  • Gastric volvulus is an uncommon clinical entity. There are three types of gastric volvulus; organoaxial, mesenteroaxial and combined type. This condition can lead to a closed-loop obstruction or strangulation. Traditional surgical therapy for gastric volvulus is based on an open approach. Here we report a successful case of a patient with chronic gastric volvulus with a laparoscopic treatment. A 79-year-old woman came to the emergency department with epigastric pain accompanied by nausea for 2 weeks. Abdominal computed tomography revealed markedly distended stomach with transposition of gastroesophageal Junction and gastric antrum. Barium meal study revealed presence of the antrum was folded over 180 degrees that was located above gastroesophageal junction. We attempted an endoscopic reduction, but it was unsuccessful. The patient got laparoscopic anterior gastropexy. Based on our result, laparoscopic gastropexy can be considered as a good choice of the treatment for gastric volvulus.