Hardware Design and Deployment Issues in UHF RFID Systems

  • Jang, Byung-Jun;Yoon, Hyun-Goo;Lim, Jae-Bong
    • Journal of electromagnetic engineering and science
    • /
    • v.9 no.1
    • /
    • pp.39-45
    • /
    • 2009
  • In this paper, we discuss hardware design and deployment issues in current passive UHF RFID systems. Using the link budget concept, the methodology to calculate forward- and reverse-link interrogation range is shown. Then, we consider hardware issues: phase diversity, phase noise with range correlation, and TX leakage problems. Finally, three interference problems when deploying RFID systems are presented.

A Study on the Precise Distance Measurement for Radar Level Transmitter of FMCW Type using Correlation Anaysis Method (상관분석법을 이용한 FMCW 타입 레이더 레벨 트랜스미터의 정밀 거리 측정에 관한 연구)

  • Ji, Suk-Joon;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1024-1031
    • /
    • 2012
  • In this paper, FMCW type radar level transmitter using correlation analysis method is implemented for precise distance measurement of cargo tank. FMCW type radar level transmitter is the device for distance measurement which calculates the distance by analyzing the beat frequency, that is, the frequency difference between Tx and RX signal from radar antenna using Fast Fourier Transform(FFT), but compensated algorithm like Zoom FFT is needed for the improvement of the frequency precision because the frequency precision of FFT is limited depending on sampling frequency and the number of sampling data. In case of Zoom FFT, the number of sampling data and noisy signal are the main factor influencing the measurement accuracy of Zoom FFT like FFT. Therefore, in order to overcome the limited environment and achieve the precise measurement, correlation coefficient is used for the distance measurement and the errors of measurement are verified to be in the range of ${\pm}1mm$.

Correlating Fully Anechoic Chamber to Open Area Test Site Measurements by the Normalized Site Attenuation

  • Kang, Tae-Weon;Kim, Byung-Wook;Chung, Yeon-Choon;Kim, Hyo-Tae
    • Journal of electromagnetic engineering and science
    • /
    • v.1 no.2
    • /
    • pp.126-130
    • /
    • 2001
  • The performance of a fully anechoic chamber (FAC) for radiated emission (RE) measurements has been evaluated using the normalized site attenuation (NSA). To do this, the antenna factor (AF) of a set consisting of nearly identical antennas has been calibrated at an open area test site (OATS). Appropriate correlation factor (CF) between the chamber and the OATS has been calculated. Results show that the performance of the chamber is fairly good with respect to the ANSI-limit except 41~66 MHz far vertical polarization and near 900 MHz for horizontal polarization.

  • PDF

Indoor Propagation Characteristics at 5.2GHz in Home and Office Environments

  • Chung, Hyun-Kyu;Bertoni, Henry L.
    • Journal of Communications and Networks
    • /
    • v.4 no.3
    • /
    • pp.176-188
    • /
    • 2002
  • This paper presents results of continuous wave and swept frequency response measurements over the frequency range of UNII lower and middle bands from 5.15GHz to 5.35GHz in indoor environments. From the continuous wave measurements at 5.2GHz, the excess path loss, and the statistical characteristics of the temporal and spatial fading were found. By sweeping the frequency over the band, envelope correlation as a function of frequency was found and the coherence bandwidth (CBW) was determined from the envelope correlation. Using a channel model, the CBW was used to evaluate RMS delay spread. The dependence of CBW on the antenna polarization was simulated and compared with the measurement results. The influence of room size and separation of transmitter and receiver for LOS paths on RMS delay spread was discussed.

On MIMO OTA Performance Characterization Method for Mobile Devices with Multiple Antennas (MIMO 무선 성능 성능평가 방법에 관한 연구)

  • Cho, Y.S.;Kim, Y.R.;No, S.P.;Shim, H.J.;Kim, I.K.
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.5
    • /
    • pp.84-90
    • /
    • 2012
  • Since the major cellular data service providers in U.S, Japan as well as in Korea started the LTE (Long Term Evolution) service, there has been more strong need for the methods that can accurately measure the MIMO (Multi Input-Multi Outout) OTA (Over The Air) performance of LTE handsets because the performance of the MIMO antenna determines the packet data rates in the downlink and therefore the higher system throughput of the network. In this regard, there has been a lot discussions in 3GPP on the candidate MIMO OTA test solutions. In this paper, a faire comparison has been done for the conventional method, the Envelop Correlation Coefficient (ECC) measurements, and the anechoic chamber based MIMO OTA test solution, one of the candidate system being discussed in 3GPP. The evaluations and the comparisons are conducted by numerically and experimentally.

SAR Data Correction Based on Calibrated-Scatterometer Measurements (보정된 Scatterometer의 측정데이터를 사용한 SAR 데이터 교정)

  • 정구준;홍진영;오이석
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.2
    • /
    • pp.121-126
    • /
    • 2004
  • This paper presents an SAR-data calibration technique using a well-calibrated scatterometer. At first a fully-polarimetric antenna pattern(magnitude and phase) of the antenna main-beam using a conducting sphere was measured. Then, this data were used to calibrate polarimetrically an auto-mounted network analyzer-based scatterometer system. This scatterometer system can be used to measure the accurate Mueller matrices of earth surfaces such as grass fields, rice fields and bare soil surfaces; i.e., the phase-difference parameters can be obtained as well as the radar scattering coefficients. If a polarimetrically calibrated scatterometer is operated at the same time with the SAR system, the scatterometer data can be used to correct the SAR data, especially the phase-difference parameters. It was found that the correction effect is remarkable for the degree of correlation ${\alpha}$, which is one of the phase-difference parameter, while the correction effect is negligible for the magnitude parameters(backscattering coefficients).

Closed-form based 3D Localization for Multiple Signal Sources (다중 신호원에 대한 닫힌 형태 기반 3차원 위치 추정)

  • Ko, Yo-han;Bu, Sung-chun;Lee, Chul-soo;Lim, Jae-wook;Chae, Ju-hui
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.2
    • /
    • pp.78-84
    • /
    • 2022
  • In this paper, we propose a closed-form based 3D localization method in the presence of multiple signal sources. General localization methods such as TDOA, AOA, and FDOA can estimate a location when a single signal source exists. When there are multiple unknown signal sources, there is a limit in estimating the location. The proposed method calculates a cross-correlation vector of signals received by sensors having an array antenna, and estimates TDOA and AOA values from the cross-correlation values. Then, the coordinate transformation is performed using the position of the reference sensor. Then, the coordinate rotation is performed using the estimated AOA value for the transformed coordinates, and then the three-dimensional position of each emitter is estimated. The proposed method verifies its performance through computer simulation.

A 2.4 GHz Bio-Radar System with Small Size and Improved Noise Performance Using Single Circular-Polarized Antenna and PLL (하나의 원형 편파 안테나와 PLL을 이용하여 소형이면서도 개선된 잡음 성능을 갖는 2.4 GHz 바이오 레이더 시스템)

  • Jang, Byung-Jun;Park, Jae-Hyung;Yook, Jong-Gwan;Moon, Jun-Ho;Lee, Kyoung-Joung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1325-1332
    • /
    • 2009
  • In this paper, we design a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals with small size and improved noise performance using single circular-polarized antenna and phase-locked loop. The demonstrated bio-radar system consists of single circular-polarized antenna with $90^{\circ}$ hybrid, low-noise amplifier, power amplifier, voltage-controlled oscillator with phase-locked loop circuits, quadrature demodulator and analog circuits. To realize compact size, the printed annular ring stacked microstrip antenna is integrated on the transceiver circuits, so its dimension is just $40\times40mm^2$. Also, to improve signal-to-noise-ratio performance by phase noise due to transmitter leakage signal, the phase-locked loop circuit is used. The measured results show that the heart rate and respiration accuracy was found to be very high for the distance of 50 cm without the additional digital signal processing.

Improving Stability and Characteristic of Circuit and Structure with the Ceramic Process Variable of Dualband Antenna Switch Module (Dual band Antenna Switch Module의 LTCC 공정변수에 따른 안정성 및 특성 개선에 관한 연구)

  • Lee Joong-Keun;Yoo Joshua;Yoo Myung-Jae;Lee Woo-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.2 s.35
    • /
    • pp.105-109
    • /
    • 2005
  • A compact antenna switch module for GSM/DCS dual band applications based on multilayer low temperature co-fired ceramic (LTCC) substrate is presented. Its size is $4.5{\times}3.2{\times}0.8 mm^3$ and insertion loss is lower than 1.0 dB at Rx mode and 1.2 dB at Tx mode. To verify the stability of the developed module to the process window, each block that is diplexer, LPF's and bias circuit is measured by probing method in the variation with the thickness of ceramic layer and the correlation between each block is quantified by calculating the VSWR In the mean while, two types of bias circuits -lumped and distributed - are compared. The measurement of each block and the calculation of VSWR give good information on the behavior of full module. The reaction of diplexer to the thickness is similar to those of LPF's and bias circuit, which means good relative matching and low value of VSWR, so total insertion loss is maintained in quite wide range of the thickness of ceramic layer at both band. And lumped type bias circuit has smaller insertion itself and better correspondence with other circuit than distributed stripline structure. Evaluated ceramic module adopting lumped type bias circuit has low insertion loss and wider stability region of thickness over than 6um and this can be suitable for the mass production. Stability characterization by probing method can be applied widely to the development of ceramic modules with embedded passives in them.

  • PDF

Human Hand Effect on The MIMO OTA Performance of LTE Mobile Handset (LTE 이동 단말의 MIMO 무선 성능과 Hand effect)

  • Cho, Y.S.;Kim, Y.R.;Noh, S.P.;Shim, H.J.;Kim, I.K.
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.5
    • /
    • pp.91-98
    • /
    • 2012
  • Since the major cellular data service providers in U.S, Japan as well as in Korea started the LTE (Long Term Evolution) service, there has been more strong need for the methods that can accurately measure the MIMO (Multi Input-Multi Output) OTA (Over The Air) performance of LTE handsets because the performance of the MIMO antenna determines the data throughput in the downlink. In this paper, the hand effect on the MIMO antenna performance is analyzed by numerically and experimentally. The hand effect on the LTE mobile handset is analyzed by measuring the link level performance in the MIMO OTA system.