• Title/Summary/Keyword: Anoxic reactor

Search Result 163, Processing Time 0.034 seconds

Characteristics of Denitrification from Municipal Wastewater Treatment using a Combined Fixed Film Reactor (CFFR) Process (복합생물막 반응기를 이용한 하수처리시 탈질화 특성)

  • 이종현;남해욱;김영규;박태주
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • A new biological nutrient removal system combining $A^2/O$ process with fixed film was developed in this work and the characteristics of denitrification were especially investigated in the combined fixed film reactor(CFFR). Media was added in the anaerobic, anoxic and aerobic reactors, respectively. Tests were made to establish the effluent level of $NO_x-N$, COD, DO and nitrite effects on $NO_x-N$ removal in the CFFR by decreasing hydraulic retention time (HRT) from 10.0 to 3.5 hours and by increasing internal recycle ratio form 0% to 200%. The influent was synthesized to levels similar to the average influent of municipal wastewater treatment plants in Korea. SARAN media with a porosity of 96.3% was packed 40% / 130% / 25% based on its reactor volume, respectively. It was found that COD rarely limited dentrification in the anoxic reactor because of high $C/NO_x/-N$ ratio in the anoxic reactor, while DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent inhibited denitrification in the anoxic reactor. It was proved that the critical points of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent were 0.15mg/L and 10%, respectively. As the internal recycle ratio increased, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent increased. Especially, at the condition of internal recycle ratio, 200%, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent exceeded the critical points of 0.15mg/L and 10%, respectively. Then, denitrification efficiency considerably decreased. Consequently, it was represented that the control of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent can assure effective denitrification.

  • PDF

Effect of Bioaugmentation on Performance of Intermittently Aerated Sewage Treatment Plant (Bioaugmentation이 간헐폭기 오수처리장치의 운전효율에 미치는 영향)

  • Jeong, Byung-Gon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.233-239
    • /
    • 2008
  • In order to improve reactor performance of existing sewage treatment plants, the feasibility of enhancing reactor performance by bioaugmentation using EM as bioaugmentation agent and the effects of anoxic: oxic time ratio on reactor performance were investigated. Continuous and intermittent aeration modes were compared under the 6 hr of HRT. Three different types of intermittent aeration modes, that is, 15 min, of anoxic:45 min of oxic, 30 min of anoxic: 30 min of oxic, and 45 min of anoxic: 15 min oxic respectively were chosen as test modes to study the effects of anoxic : oxic time ratios on reactor performance. The optimum anoxic: oxic time ratio was 30 min:30 min when considering simultaneous removal of organic, nitrogen and phosphorus. When applying EM into a continuously aerated reactor under the varying dosing rates of 50-200 ppm, reactor performance in terms of organic and nitrogen removal efficiencies was not improved at all. Nitrogen removal efficiency was increase when the EM dosing rate was increased. However the degree of improvement was slight when the EM was injected above 100 ppm. However optimum phosphorus removal was found at the EM dosing of 200 ppm. Thus it was found that optimum injection concentration of EM is 200 ppm. It is apparent that putting EM into a sewage treatment plant significantly affects the T-N removal efficiency of the reactor by enhancing denitrification efficiency especially in operational conditions of relatively long anoxic periods. To achieve reciprocal condition in a reactor with intermittent aeration it is necessary to enhance the reactor performance by EM injection. In the case of modifying existing continuously aerated reactors into intermittent aerated reactors, it is obvious that operating costs of aeration would be reduced by reducing aeration time when compared with existing conventional sewage treatment plants.

Characteristics of Organics and Nitrogen Removal with the Recycle Ratio in Anoxic / Oxic Packed Bed Process (충전탑형 무산소/호기 공정에서 반송비에 따른 유기물 및 질소 제거 특성)

  • 선용호
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1261-1265
    • /
    • 2002
  • This study was focused on the investigation of the characteristics of organics and nitrogen removal with the recycle ratio in anoxic/oxic(A/O) packed bed process that consisted of the anoxic reactor and the aerobic reactor. As increasing the recycle ratio by 0.5, 1.0, 2.0, the COD removal efficiency increased by 94.0%, 98.5%, 98.8% respectively. The aerobic reactor showed the perfect nitrification efficiency by 98.5%, 99.2%, 98.0% respectively. The T-N removal efficiency with the recycle ratio, increased by 56%, 67%, 70% respectively. As increasing the recycle ratio by 0.5, 1.0, 2.0, T-P removal efficiency decreased by 62.1%, 57.4%, 51.3% respectively. The process by releasing the stored phosphorus in the anoxic reactor and uptaking the excess phosphorus in the aerobic reactor, occurred well comparatively when recycle ratio is 0.5. But this process did not occur when the recycle ratio is 1.0 and 2.0. And optimum pH of nitrification was about 6~7 and alkalinity decreased as nitrification rate increased. As increasing the recycle ratio in the anoxic reactor, DO concentration and ORP increased.

A Study on the Treatment of Swine Wastewater by Using Intermittently Aerated Activated Sludge Process (간헐폭기법에 의한 돈사 폐수 처리에 관한 연구)

  • Yang, Tae-Du;Lee, Mi-Kyung;Chung, Yoon-Jin
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.4
    • /
    • pp.86-96
    • /
    • 1998
  • In this study, an intermittently aerated activated sludge process, modified process from conventional activated sludge process, was developed to treat high strength swine wastewater, which has been blamed as major pollutant for stream pollution. Therefore, the optimum cycle for oxic and anoxic period, SRT, and OLR were studied as design parameters. The effects of different time interval for oxic and anoxic period on nitrification and denitrification were examined by operating two reactors with 60/60min and 60/90min as oxic/anoxic period. Although the reactor with 60/60min showed complete denitrification of $NO_x-N$ generated during oxic period, the reactor with 60/90min showed incomplete nitrification due to the inactivity of nitrifier by accumulated $NH_3-N$ toxicity during anoxic period. Therefore, it is recommended to operate same interval for oxic and anoxic period. In order to determine the optimum cycle for oxic/anoxic period, four different reactors with 30/30, 60/60, 90/90 and 120/120min were examined. The reactor operation with 90/90min was optimum to get the most stable results in this study. However, the optimum cycle for oxic and anoxic period should be changed with characteristics of influent wastewater and operating conditions. According to lie operation results of three reactors with SRT of 15, 20 and 30days. The reactor with 2Odays SRT showed best removal efficiency of T-N. The optimum OLR would be $2.5Kg\;COD/m^3/day$ which showed the most stable nitrification and denitrification. Since characteristics of influent wastewater in the real system has a severe fluctuation, so it is very difficult to determine each interval for oxic and anoxic period. Therefore, ORP curves, describing the change of oxidation/reduction potential in reactor, can be used as a control parameter for automatic control of oxic and anoxic period. In other words, bending point (Nitrate Knee) of ORP curve during anoxic period could be used as a starting point of oxic period.

  • PDF

PHOSPHORUS RELEASE AND UPTAKE ACCORDING TO NITRATE LOADING IN ANOXIC REACTOR OF BNR PROCESS

  • Kim, Kwang-Soo
    • Environmental Engineering Research
    • /
    • v.10 no.5
    • /
    • pp.257-263
    • /
    • 2005
  • A batch and a continuous type experiments were conducted to test the conditions for simultaneous phosphorus release and uptake, and denitrification, taking place in one process. The bacteria able to denitrify as well as to remove phosphorus were evaluated for the application to biological nutrient removal(BNR) process. In the batch-type experiment, simultaneous reactions of phosphorus release and uptake, and also denitrification were observed under anoxic condition with high organic and nitrate loading. However the rate and the degree of P release were lower than that occurred under anaerobic condition. BNR processes composed of anaerobic-anoxic-oxic(AXO), anoxic-anaerobic-oxic(XAO) and anoxic-oxic(XO) were operated in continuous condition. The anoxic reactors in each process received nitrate loading. In the AXO process, P release in anaerobic reactor and the luxury uptake in oxic reactor proceeded actively regardless to nitrate loading. However in XAO and XO processes, P release and luxury uptake occurred only with the nitrate loading less than $0.07\;kg{NO_3}^--N$/kgMLSS-d. With higher nitrate load, P release increased and the luxury uptake decreased. Therefore, it appeared that the application of denitrifying phosphorus-removing bacteria (DPB) to BNR process must first resolve the problem with decrease of luxury uptake of phosphorus in oxic reactor.

Comparative study on response of thiocyanate shock load on continuous and fed batch anaerobic-anoxic-aerobic sequential moving bed reactors

  • Sahariah, B.P.;Chakraborty, S.
    • Environmental Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.65-72
    • /
    • 2015
  • A comparative study on response of a toxic compound thiocyanate ($SCN^-$) was carried out in continuous and fed batch moving bed reactor systems. Both systems had three sequential anaerobic, anoxic and aerobic reactors and operated at same hydraulic retention time. Feed $SCN^-$ was first increased from 600 mg/L to 1,000 mg/L for 3 days (shock 1) and then from 600 to 1,200 mg/L for 3 days (shock 2). In anaerobic continuous reactor, increase of effluent COD (chemical oxygen demand) due to shock load was only 2%, whereas in fed batch reactor it was 14%. In anoxic fed batch reactor recovery was partial in terms of $SCN^-$, phenol, COD and $NO{_3}{^-}$-N and $NO{_2}{^-}$-N removals and in continuous reactor complete recovery was possible. In both systems, inhibition was more significant on aerobic reactors than anaerobic and anoxic reactors. In aerobic reactors ammonia removal efficiency deteriorated and damage was irreversible. Present study showed that fed batch reactors showed higher substrate removal efficiency than continuous reactors during regular operation, but are more susceptible to toxic feed shock load and in nitrifying reactor damage was irreversible.

A Study on the Effect of an HRT of Anoxic Reactors on Organic Matter and Nitrogen Removal in A2/O Processes with Bio Contact Media in Aerobic Tank (호기조에 고정상 담체를 충진한 A2/O공정에서 무산소조 체류시간 변화가 유기물질 및 질소 제거에 미치는 영향)

  • Whang, Gye-Dae;Han, Bong-Seok
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.4
    • /
    • pp.451-457
    • /
    • 2007
  • Four parallel $A^2/O$ systems maintaining an MLSS of 3,000 mg/L were operated to investigate the effects of varying an HRT of anoxic reactors and packing Bio contact media (BCM, fixed beds) in aerobic reactors on organic matter removal and nitrification/denitrification efficiencies. All systems were operated under conditions that the external recycle ratio was kept 0.5 Q while the internal recycle ratio was changed 1.0 Q to 1.5 Q with that $NH_4-N$ concentration of feed was increased to 40 mg/L by adding $NH_4Cl$. In terms of TSS and TCODcr removal efficiency, both systems with BCM and a system without BCM, respectively, had a similar level of the removal efficiency under varied HRTs of anoxic reactors (0.6 hr, 1.3 hr, 2 hr, 2 hr; control, without BC M) showing that varying an HRT of anoxic reactors did not affect the removal efficiency. While SCODcr removal efficiency of systems with BCM was improved approximately 4~5% at the same HRT of anoxic reactor, the removal efficiency of system with BCM was slightly decreased by reducing an HRT of anoxic reactor. The nitrification efficiency for both systems with BCM and a system without BCM was above 94% showing that packing BCM in aerobic reactors and varying an HRT of anoxic reactors did not affect the efficiency significantly despite of increasing $NH_4-N$ concentration of feed. The denitrification efficiency increased from 81.4% to 85.4% at system with BCM while the efficiency decreased when a shorter HRT of anoxic reactors was kept. The excellent effluent quality for $NO_3-N$ concentration was observed although the $NO_3-N$ concentration increased in anoxic reactors that $NH_4-N$ concentration of feed sufficiently converted into nitrate through nitrification. As a result, packing 20% BCM to an aerobic reactor with HRT of 1.3 hr of anoxic reactor in $A^2/O$ system can achieve a similar level of nitrogen removal efficiency in $A^2/O$ system which the aerobic reactor had no BCM and HRT of 2 hr for anoxic reactor is maintained.

Removal Characteristic of Nitrogenous Compounds According to the Combination of Feeding Ratio between the Supernatant of Precipitation Tank and Raw Domestic Wastewater (침전조 상등액과 유입하수의 유량대비에 따른 하수 내 질소 화합물 제거특성)

  • Park, Sang Min;Park, Jin Hee
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.4
    • /
    • pp.128-135
    • /
    • 2005
  • This study was done to improve the effectiveness of nitrification and denitrification using the aeration-anoxic combination method using CFSTR(continuous-flow stirred-tank reactor) attached with an anoxic reactor filled with a media. In order to calculate the concentration of nitric acid within the aeration tank proportional to the anoxic rate within the reactor, supernatant within the inflow and precipitation tanks were influxed into the anoxic reactor. The rate of nitrogen removal was calculated using the concentration of inflow and flow of returned supernatant. From the results of this experiment, the carbon source needed in the anoxic reactor came from the inflow so that anoxification was achieved completely using the inflow source without the introduction of an external carbon source. However, as the ratio of nitric acid becomes large in inflow and nitric acid flow, the carbon source within the input source decreases so that the concentration of carbon source is important.

  • PDF

Removal of Organics and Nirtogen in Wastewater Using 2 Stage A/O(RBC) Process (RBC 반응조를 이용한 2단 A/O 공정에서 유기물질 및 질소제거)

  • 최명섭;손인식
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.3
    • /
    • pp.59-64
    • /
    • 2003
  • This study was conducted to investigate anoxic-RBC-anoxic-RBC process and its application to remove biologically organics and nitrogen. BOD and total-nitrogen(T-N) removal efficiencies were decreased as volumetric loading rate increased. But, the removal efficiency changes of T-N were little, as compared to BOD. Increase of internal recycle rate had few affect of BOD and T-N removal rates. Also, influent allocation(to 2nd anoxic reactor) had few affect of BOD removal efficiency rate. However, when the influent allocation rate was 30%, T-N removal efficiency was increased to 84.1 %. BOD/N ratio applied to 2nd anoxic reactor was increased to range of 3.65-4.37 as influent allocation rate increased to range 20∼35%. But, it might also cause adverse effect such as decrease of denitrification rate in excessive influent allocation rate.

Advanced Wastewater Treatment Using Anoxic-Aerobic Reactor Filled with Porous Media (다공성 미디어를 충진한 혐기-호기 반응조를 이용한 하수고도처리에 관한 연구)

  • Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.83-89
    • /
    • 2007
  • A biological anoxic-aerobic reactor filled with porous media was operated in lab scale for the advanced wastewater treatment. The experiments were conducted for 6 months with three HRTs (4, 6, 8hr) and temperature of $23{\sim}25^{\circ}C$. Some other experimental conditions were as follows; nitrification reactor (MLSS 4,500mg/L, DO 3.3mg/L, $23{\sim}28^{\circ}C$), denitrification reactor(MLSS 8,000mg/L, ORP -100mV, Temp.$19{\sim}23^{\circ}C$). Average removal efficiencies of SS, $BOD_5$, $COD_{Cr}$, T-N, and T-P were 97.8%, 95.5%, 94.5%, 80.2%, and 60.6%, respectively. The reactor filled with porosity media showed stable removal capacity for organics and nutrients. Fast and complete nitrification and denitrification were accomplished. Maintaining high MLSS with porous media in the nitrification and denitrification reactor appears to enhance the nitrogen removal process. For the higher T-P removal, some coagulant addition process will be needed.