• Title/Summary/Keyword: Annular flow

Search Result 349, Processing Time 0.024 seconds

A Fundamental Study of the Subsonic Spiral Jet (아음속 스파이럴 제트 유동에 관한 기초적 연구)

  • Cho, Wee-Bun;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.502-507
    • /
    • 2003
  • Spiral jet is characterized by a wide region of the free vortex flow with a steep axial velocity gradient, while swirl jet is largely governed by the forced vortex flow and has a very low axial velocity at the jet axis. However, detailed generation mechanism of spiral flow components is not well understood, although the spiral jet is extensively applied in a variety of industrial field. In general, it is known that spiral jet is generated by the radial flow injection through an annular slit which is installed at the inlet of convergent nozzle. The objective of the present study is to understand the flow characteristics of the spiral jet, using a computational method. A finite volume scheme is used to solve 3-dimensional Navier-Stokes equations with RNG ${\kappa}-{\varepsilon}$ turbulent model. The computational results are validated by the previous experimental data. It is found that the spiral jet is generated by coanda effect at the inlet of the convergent nozzle and its fundamental features are dependent the pressure ratio of the radial flow through the annular slit and the coanda wall curvature.

  • PDF

The Numerical Study on the Cobustion Characteristics and the Heat Transfer Characteristics of Heat Exchanger for Condensing Gas Boiler (응축형 가스보일러 연소기의 연소특성 및 열교환기의 열전달특성에 관한 수치적 연구)

  • Kim, S.C.;Kum, S.M.;Lee, C.E.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.71-78
    • /
    • 2001
  • It was numerically studied that characteristics of fluid flow and heat transfer in a tube with disk and annular baffle for heat exchanger of condensing boiler. Using a finite volume technique and CFD code, STAR-CD, the governing equations were solved and the temperature and flow fields were investigated. The interval between tube and annular baffle, height and diameter of baffle were selected as important design parameters, and the effects of these parameters on heat transfer and fluid flow were studied. As a result, in the case of with interval, the pressure was decreased but heat transfer was increased. Also heat transfer was slowly increased as the size of disk and annular baffle were increased and the distance between baffles were decreased.

  • PDF

Evaluation of the Effect of Annular-to-Intermittent Plow Transition Model on the Dryout Model (환상류-간헐류 천이 모텔이 드라이아웃 모델에 미치는 영향 평가)

  • WU S.I.;Im In Cheol
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.220-223
    • /
    • 2004
  • The initial conditions such as the film thickness and the void fraction at the onset of annular flow are required for the analytical dryout model. The Disturbance Wave Instability model(DWI model) is one of the model describing the Annular-to-Intermittent Flow regime Transition(AIFT). The experimental CHF conditions for the uniformly heated tube were compared with the predictions by the modified Levy model, for which the initial conditions at AIFT were estimated by the DWI model. For the flow through long tubes with small inlet subcooling, the effect of AIFT model on the dryout prediction was little. However, the use of DWI model gave better prediction of CHF in a short tube.

  • PDF

Rotordynamic and Leakage Analysis for Eccentric Annular Seal (편심된 실의 누설량 및 동특성계수 해석)

  • 하태웅;이용복;김창호
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.528-534
    • /
    • 2001
  • Basic equations and its solution procedure are derived for the analysis of an annular pump seal in which the rotor has a large static displacement from the centered position. The Bulk-flow is assumed for a control volume set in the seal clearance and the flow is assumed to be completely turbulent in axial and circumferential direction. Moody's wall-friction-factor formula is used for the calculation of wall shear stresses in the control volume. For the reaction force developed by the seal, linearized zeroth-order and first-order perturbation equations are developed for small motion about an eccentric position. Flow variables are expanded by using Fourier series for the solution procedure. Integration of the resultant first-order pressure distribution along and around the seal defines the 12 elements of rotordynamic coefficients of the eccentric annular pump seal. The results of leakage and rotordynamic coefficients are presented and compared with the Marquette's experimental results and the San Andres' theoretical analysis.

  • PDF

Fluctuation Characteristics of Radial Void Fraction in Vertical Concentric Annuli (수직동심환상관에서 반경방향 보이드율의 변동특성)

  • Son B.J.;Kim I.S.;Kim M.C.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.16 no.5
    • /
    • pp.516-524
    • /
    • 1987
  • This paper presents experimental data of fluctuation characteristics of local void fraction of air-water two-phase flow which are associated with the flow pattern, annular gap size and radial location in vertical concentric annuli with coefficient of skewness and kurtosis. The annular gap widths are 13mm, 11mm, and 9mm for a 38m inner diameter as the lucite outer tube. A electrical conductivity probe was used to measure the local void fraction and traversed diametrically from inner wall to outer wall using radial increments of 2mm. It was shown that distribution of the coefficient of skewness and kurtosis, which is related that the one is the asymmetry and the other peakness of local void fraction distribution was influenced by flow pattern, annular gap size and radial location.

  • PDF

Prediction of Two-phase Flow Patterns and Noise Evaluation for Evaporator Pipe in a Refrigerator (냉장고 증발기 배관의 2상유동양식 예측 및 소음 평가)

  • Heo, So-Jung;Kim, Min-Seong;Han, Hyung-Suk;Jeong, Weui-Bong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.916-923
    • /
    • 2011
  • The refrigerant after the expansion valve interchanges the heat at the evaporator. At this moment, the state of gas and liquid becomes two-phase flow and causes irregular noise. In order to avoid the noise, the two-phase flow pattern should be predicted. In this paper, the procedure to predict the two-phase flow patterns such as churn flow and annular flow was suggested using the CFD software. The experiments using refrigerant-supplying equipment was carried out and the noise levels according to the flow pattern were measured. The flow patterns predicted by this procedure showed good agreement with those by experiments. The churn flow is noisier than annular flow pattern.

A study on the development of the velocity and temperature fields in a laminar flow through an eccentric annular ducts (偏心된 二重圓管의 環狀部를 지니는 層流流動에서의 連度場 및 溫度場의 確立에 대한 硏究)

  • 이택식;이상산
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.861-869
    • /
    • 1986
  • A numerical study has been conducted on the development of the velocity and temperature fields in a laminar flow through an eccentric annular duct. A bipolar coordinates system is adopted, and a numerical program is developed to analyze 3-dimensional parabolic flow problems. In the analysis of the velocity field, the entrance length has been defined as the distance where the axial pressure gradient is greater than that of the developed velocity field by 5%. The dimensionless hydrodynamic entry length increases with increasing eccentricity. In the transverse flow fields, the reverse flow region along the wall due to the developing axial velocity near the entrance of the duct is found. In the analysis of the temperature field, the thermal entry length has been defined as the axial distance where the mean fluid temperature is 5% less than that of the developed temperature field. The dimensionless thermal entry length increases as eccentricity or Prandtl number increases. The overshoot of the mean Nusselt number over the developed value at the zero-temperature wall is encountered, and the rate of the overshoot increases with the increase of the eccentricity and Prandtl number.

The Numerical Study on the Heat Transfer Characteristics of Heat Exchanger for Condensing Gas Boiler (응축형 가스보일러 열교환기의 열전달특성에 관한 수치적 연구)

  • Kim, Seok-Cheol;Geum, Seong-Min;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.12
    • /
    • pp.1853-1860
    • /
    • 2001
  • Characteristics of fluid flow and heat transfer in a tube with disk and annular baffle for heat exchanger of condensing boiler was numerically studied. The STAR-CD code was used to solve the governing equations and the temperature and flow fields were investigated. The interval between tube and annular baffle, height and diameter of baffle were selected as important design parameters, and the effects of these parameters on heat transfer and fluid flow were studied. As a result, in the case of with interval, the pressure was decreased, but heat transfer was increased. Heat transfer was slowly increased as the size of disk and annular baffle were increased and the distance between baffles were decreased. The pressure drop was rapidly changed fur diameter and size of disk and annular baffle. In addition, it was desirable that optimal conditions to design heat exchanger were about B$\_$a/R=0.5, L/R=1.

Critical Heat Flux and Flow Pattern for Water Flow in Annular Geometry

  • Park, Jae-Wook;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.224-229
    • /
    • 1996
  • An experimental study on critical heat flux (CHF) and two-phase flow visualization has been performed for water flow in internally-heated, vertical, concentric annuli under near atmospheric pressure. Tests have been done under stable forced- circulation, upward and downward flow conditions with three test sections of relatively large gap widths (heated length = 0.6 m. inner diameter = 19 mm, outer diameter = 29, 35 and 51 mm). The outer wall of the test section was made up of the transparent Pyrex tube to allow the observation of flow patterns near the CHF occurrence. The CHF mechanism was changed in the order of flooding, chum-to-annular flow transition, and local dryout under a large bubble in churn flow as the flow rate was increased from zero to higher values. Observed parametric trends are consistent with the previous understanding except that the CHF for downward flow is considerably lower than that for upward flow.

  • PDF