• 제목/요약/키워드: Annual application

검색결과 583건 처리시간 0.029초

An experimental performance analysis of a cold region stationary photovoltaic system

  • Choi, Wongyu;Warren, Ryan D.;Pate, Michael B.
    • Advances in Energy Research
    • /
    • 제4권1호
    • /
    • pp.1-28
    • /
    • 2016
  • A grid-connected photovoltaic (PV) system comprised of multicrystalline silicon (mc-Si) modules was installed in a cold climate region in the U.S. This roof-mounted stationary PV system is a real-world application of PV for building energy generation in International Energy Conservation Code (IECC) Climate Zone 5 (and possibly similar climate zones such as 6, 7 and 8), and it served the purposes of research, demonstration, and education. The importance of this work is highlighted by the fact that there has been less emphasis on solar PV system in this region of the U.S. because of climate and latitude challenges. The system is equipped with an extensive data acquisition system capable of collecting performance and meteorological data while visually displaying real-time and historical data through an interactive online interface. Experimental data was collected and analyzed for the system over a one-year period with the focus of the study being on measurements of power production, energy generation, and efficiency. The annual average daily solar insolation incident upon the array was found to be $4.37kWh/m^2$. During the first year of operation, the PV system provided 5,801 kWh (1,264 kWh/kWp) of usable AC electrical energy, and it was found to operate at an annual average conversion efficiency and PR of 10.6 percent and 0.79, respectively. The annual average DC to AC conversion efficiency of the inverter was found to be 94 percent.

다양한 운전모드에서 물대물 열펌프의 성능 및 최적충전량 변화에 관한 연구 (Influence of the Operation Modes on the Optimum Refrigerant Charge Amount of a Heat Pump)

  • ;이광호;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제14권2호
    • /
    • pp.15-22
    • /
    • 2018
  • As heat pump application has been extending to residential, commercial, and industrial fields, the heat pump should have many operation modes. It is required to optimize refrigerant charge amount at all operation modes in order to enhance the annual performance of heat pumps. In this study, the performance analysis of the heat pump which has cooling, heating, cooling-hot water, heating-hot water, and hot water modes was executed with the variation of refrigerant charge amount. As the refrigerant charge amount changed, the maximum COPs of the heat pump at different operation modes were changed within ${\pm}10%$. Therefore, it is highly recommended to select optimum charge amount for the heat pump based on the analysis of annual load for each operation modes.

사무소건물의 가동식 수평차양에 대한 연구 (A Study on Design of Movable Horizontal Shading Device for Office Building)

  • 김미현;서승직
    • 한국태양에너지학회 논문집
    • /
    • 제28권2호
    • /
    • pp.50-57
    • /
    • 2008
  • This study intends to evaluate the effect on indoor environment(annual thermal load, sunshine)by the application of the movable horizontal shading device on summer and winter season. For these purpose, we supposed the models which are composed of the several horizontal shading devices. Then we analyzed the simulation using the IES5.5.1 and Seoul weather data. The results of this study are as follows: 1) The proper length, angle of horizontal shading device is 2.1m, 28 degree, respectively. 2) The decreasing rate of the annual load of the Movable Horizontal Shading Model(MHSM) in comparison with the No Shading Model(NSM) & Conventional Horizontal Shading Model(CHSM) is 31.11%, 6.63% respectively. 3) The decrease of sunshine of the MHSM on summer season is effective the alleviation of visual displeasure. On the other hand, the increase of sunshine of the MHSM on winter season is effective the psychological comfort. Further study is to be required the sensitivity analysis on the various shading length for the realistic proper shading length.

Comparing Carbon Reduction Estimates for Tree Species from Different Quantitative Models

  • Hyun-Kil Jo;Hye-Mi Park
    • Journal of Forest and Environmental Science
    • /
    • 제39권3호
    • /
    • pp.119-127
    • /
    • 2023
  • In this study, quantitative models were applied to case parks to estimate the carbon reduction by trees, which was compared and analyzed at the tree and park levels. At the tree level, quantitative models of carbon storage and uptake differed by up to 7.9 times, even for the same species and size. At the park level, the carbon reduction from quantitative models varied by up to 3.7 times for the same park. In other words, carbon reduction by quantitative models exhibited considerable variation at the tree and park levels. These differences are likely due to the use of different growth environment coefficients and annual diameter at breast height growth rates and the overestimation of carbon reduction due to the substitution of the same genus and group model for each tree species. Extending the annual carbon uptake per unit area of the case park to the total park area of Chuncheon a carbon uptake ranging from a minimum of 370.4 t/yr and a maximum of 929.3 t/yr, and the difference can reach up to 558.9 t/yr. This is equivalent to the carbon emissions from the annual household electricity consumption of approximately 2,430 people. These results suggest that the indiscriminate application of quantitative models to estimate carbon reduction in urban trees can lead to significant errors and deviations in estimating carbon storage and uptake in urban greenspaces. The findings of this study can serve as a basis for estimating carbon reduction in urban greening research, projects, and policies.

Flood Risk Management for Weirs: Integrated Application of Artificial Intelligence and RESCON Modelling for Maintaining Reservoir Safety

  • Idrees, Muhammad Bilal;Kim, Dongwook;Lee, Jin-Young;Kim, Tae-Woong
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2020년도 학술발표회
    • /
    • pp.167-167
    • /
    • 2020
  • Annual sediment deposition in reservoirs behind weirs poses flood risk, while its accurate prediction remains a challenge. Sediment management by hydraulic flushing is an effective method to maintain reservoir storage. In this study, an integrated approach to predict sediment inflow and sediment flushing simulation in reservoirs is presented. The annual sediment inflow prediction was carried out with Artificial Neural Networks (ANN) modelling. RESCON model was applied for quantification of sediment flushing feasibility criteria. The integrated approach was applied on Sangju Weir and also on estuary of Nakdong River (NREB). The mean annual sediment inflow predicted at Sangju Weir and NREB was 400,000 ㎥ and 170,000 ㎥, respectively. The sediment characteristics gathered were used to setup RESCON model and sediment balance ratio (SBR) and long term capacity ratio (LTCR) were used as flushing efficiency indicators. For Sangju Weir, the flushing discharge, Qf = 140 ㎥/s with a drawdown of 5 m, and flushing duration, Tf = 10 days was necessary for efficient flushing. At NREB site, the parameters for efficient flushing were Qf = 80 ㎥/s, Tf = 5 days, N = 1, Elf = 2.24 m. The hydraulic flushing was concluded feasible for sediment management at both Sangju Weir and NREB.

  • PDF

소수력발전소의 성능예측 (A Study on the Performance Prediction for Small Hydro Power Plants)

  • 박완순;이철형
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.448-451
    • /
    • 2005
  • This paper presents the methodology to analyze flow duration characteristics and performance prediction for small hydro power(SHP) plants and its application. The flow duration curvecan be decided by using monthly rainfall data at the most of the SHP sites with no useful hydrological data. It was proved that the monthly rainfall data can be characterized by using the cumulative density function of Weibull distribution and Thiessen method were adopted to decide flow duration curve at SHP plants. And, the performance prediction has been studied and development. One SHP plant was selected and performance characteristics was analyzed by using the developed technique. Primary design specfications such as design flowrate, plant capacity, operational rate and annual electricity production for the SHP plant were estimated. It was found that the methodology developed in this study can be a useful tool to predict the performance of SHP plants and candidate sites in Korea.

  • PDF

WindPRO의 예측성능 평가 (Evaluation of the Performance on WindPRO Prediction)

  • 오현석;고경남;허종철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.300-305
    • /
    • 2008
  • Using WindPRO that was software for windfarm design developed by EMD from Denmark, wind resources for the western Jeju island were analyzed, and the performance of WindPRO prediction was evaluated in detail. The Hansu site and the Yongdang site that were located in coastal region were selected, and wind data for one year at the two sites were analyzed using WindPRO. As a result, the relative error of the Prediction for annual energy Production and capacity factor was about ${\pm}20%$. For evaluating wind energy more accurately, it is necessary to obtain lots of wind data and real electric power production data from real windfarm.

  • PDF

하수열원을 이용한 지역난방 적용성 검토 (A Study on the Application of District Heating System using Sewage Source)

  • 김상훈;김동진;최동규
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.928-933
    • /
    • 2009
  • The purpose of this study is to examine the energy consumption, carbon dioxide emission & energy cost of district heating using sewage source. The annual TOE of heat pump using sewage source save 37.1 percent than city gas boiler. And annual carbon dioxide emission of heat pump cut down 41.3 percent than city gas boiler. If it charges the rate schedule for district heating to apartment resident, collected amount are 3,127,170 thousand won. As energy cost of heat pump & circulation pump are 1,378,072 thousand won. the profits are 1,749,098 thousand won. As payback period is 8.97years, applicability is low level. However, it has advantages in energy consumption, carbon dioxide emission & energy cost. Therefore, it needs to proceed through government assistance.

  • PDF

경기도 일죽 지역 천부 지하수질의 연간 변화

  • 김연태;정성욱;현승규;신우식;우남칠
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 2003년도 추계학술발표회
    • /
    • pp.489-492
    • /
    • 2003
  • This study is objected to identify the annual variation of shallow groundwater quality in the study area, Hwabong-Jangam, Iljuk-Meon, Kyunggi-Do. The previous study in 2002 shown a wide-spread contamination of shallow groundwater by nitrate mainly originated from wastes of livestock facilities. In the year 2003, groundwater quality of the area has worsened due to the agricultural activities including the application of organic fertilizer and agro-chemicals to improve soil quality. In addition, a leaking septic tank, identified in the previous study, is still expanding its influence on the nearby wells.

  • PDF

제주 한천유역의 실제 증발산량 평가 (Assessment of Actual Evapotranspiration in the Hancheon Watershed, Jeju Island)

  • 김남원;이정은
    • 한국환경과학회지
    • /
    • 제22권5호
    • /
    • pp.533-542
    • /
    • 2013
  • In this study, estimation methods for actual evapotranspiration have been studied using the concept of potential and actual evapotranspiration. Among the diverse estimation methods, SWAT-K application is chosen for hydrological modeling. For Jeju island we have characterized annual and monthly evapotranspiration using SWAT-K. In the results, simulated potential evapotranspiration reached to the 91% of small pan evaporation. With respect to the temperature lapse rate($-6^{\circ}C/km$) depending on the altitude of Halla mountain, evapotranspiration rate decreased by 7.5% compared to the status when the temperature data from the Jeju weather station were applied to the watershed. As the average of annual rainfall increased, potential evapotranspiration was increased, actual evapotranspiration was, however, decreased.