• Title/Summary/Keyword: Annual Load

Search Result 323, Processing Time 0.026 seconds

A Study on the Performance Prediction Methodology of Small Hydropower Plant (소수력발전소의 성능예측기법에 관한 연구)

  • Lee, C.H.;Park, W.S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.742-747
    • /
    • 2005
  • A model, which can analyze the hydrological performance for small hydropower(SHP) plants having no flow duration characteristics has been studied and developed. System performance of existing SHP plant under operating was analyzed by using the developed model. The annual operational rate of SHP plant showed that the data were in good agreement with predicted results from the model. Based on these results, several SHP sites to be exploited were selected and the performance characteristics were analyzed by using the developed model. Also, primary design values such as design flow rate, plant capacity, and operational rate were suggested. As a result, it was found that the methodology used in this study is useful tool to predict the hydrological system performances of SHP sites.

  • PDF

Distribution System Reliability Evaluation Considering Protective System (보호시스템을 고려한 배전계통의 신뢰도 평가)

  • Kim, S.H.;Jwa, C.K.;Choi, B.Y.;Choi, S.H.;Kim, J.G.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.1003-1005
    • /
    • 1997
  • To evaluate the quality of a system or its ability to perform a required function, it is necessary to quantify the reliability of that system. The reliability techniques are based on the concept of expected failure rate and average-outage-duration method. For each load point, the expected failure rate, average outage duration and average annual outage time are evaluated. This paper deals with the reliability evaluation for distribution system including the protection relay system. In evaluating the reliability, it suggests a method for the analysis of protective system reliability, that provides a probabilistic measure of the success of the protective apparatus to perform its intended function. The analysis shows the dependency of success on the reliability of many components, and the way this reliability may be enhanced by redundancy.

  • PDF

A Study of Thermal Performance Evaluation Index for Building (건물의 열성능 평가 지표에 관한 연구)

  • Kim, Mi-Hyun;Suh, Seung-Jik
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.67-75
    • /
    • 2007
  • This study intends to the adequacy inspection of the room temperature variation rate that is available in the building heat performance evaluation index, so we performed the sensitivity analysis about the room temperature variation rate and the energy consumption in the room. For these purpose, we supposed the models which are composed of the various window area, insulation thickness and ventilation rate. Then we analyzed the simulation using the ESP-r and Seoul weather data. In this research, the pattern of the increasing & decreasing rate of annual load according to the change of the various design factors is similar to the pattern of increasing & decreasing rate of not the K-values but the room temperature variation rate. Also we derive the optimum value of the various design factors and the room temperature variation rate in this analysis model. Further study is to be required the development of convenient tool to use in the real design.

A Study on the Energy Performance Renovation for the Sustainable the Residential Houses (친환경주거단지를 위한 에너지 성능개선에 관한 연구)

  • Park, Jin-Chul;Kim, Ki-Hoon;Song, Gook-Sup;Lee, Hyun-Woo
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.4
    • /
    • pp.89-96
    • /
    • 2003
  • In planning a building retrofit, energy conservation, thermal comfort and economic benefits should be considered. In this study, retrofit effects of exterior insulating method on preventing condensation, saving energy were analyzed through the heat transfer simulation, energy simulation in the apartment house retrofitted by exterior insulating method cheaper than other retrofit methods. The results of this study show that the retrofit using exterior insulating method can prevent the condensation at the corner walls and save about 20% of annual heating load. The LCC analysis revealed to be effective to select a dryvit system for a building retrofit.

Performance Analysis of Sensible and Latent Energy Recovery System for Thermally Controlled Facilities (향온시설물에 대한 현열 및 잠열 에너지 회수시스템의 성능해석)

  • 박병규;김무근;김근오
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.12
    • /
    • pp.1057-1065
    • /
    • 2000
  • A sizing of sensible and latent energy recovery system with condensing heat exchanger is important to the design of a thermally controlled facilities. The transient system simulation program TRNSYS 14.2/IISiBat has been used to evaluate the energy consumptions of a thermally controlled facilities which consist of boiler, chiller and condensing heat exchanger, The boiler and chiller are selected based on the annual peak loads and controlled to maintain the setting temperature of $14~17^{\circ}C$. Simulation shows that the amount of sensible and latent energy recovered by heat exchanger is almost 20% of total heating load.

  • PDF

Developing electric railway load pattern inspection program and optimizing power rate (전철변전소 전력부하패턴 점검 프로그램 개발 및 요금최적화)

  • Jeon, Yong-Joo;Lee, Gi-Chun;Park, Ki-Bum;Lee, Tae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1163-1164
    • /
    • 2007
  • At present, one of the big characteristics in electric power market in korea is unique seller but in the near future competitions are expected in the market. so additional service for the electric power are expected. Also with development of IT technology, remote inspection for power usage are possible so as consumption pattern analysis. KORAIL is one of the biggest consumer in electric power market so it is necessary to investigate power consumption pattern. This paper presents electric power rate definition program based on billing system database and also basic power rate optimization method. Base on the substation annual power usage DB data, the characteristic of the substation power consumption are investigated and effective electrical billing system are compared each other. Through this program it is verified that we can save more then several hundred million won for a year.

  • PDF

A Study on the Evaluation of Cooling Demand using Cooling Gas Sales (냉방용 가스사용을 중심으로 추정한 냉방전력수요 평가)

  • KIM C.S.;Rhee C.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.660-662
    • /
    • 2004
  • Cooling demand in Korea has increased constantly. Furthermore, an evaluation and savings of cooling demand has impacted on summer DSM and investment in Korea. Absorbed cooling system uses gas. It could achieve reductions in summer peak load and increase gas demand simultaneously. However its efficiency rate is lower than electric system. Gas cooling system uses separate meter. Therefore we could analyze monthly cooling demand and derive annual uses pattern. This paper analyzes demand pattern of gas cooling and its effects on electricity savings. Also this paper presents the course of policy in electricity sector on spreading of gas cooling measures.

  • PDF

A study on the PAL according to thermal characteristic of building skin and perimeter zone depth (건물 외피의 열특성과 외주부 깊이에 따른 PAL에 관한 연구)

  • Kim, Ji-Hye;Kim, Hwan-Yong
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.2
    • /
    • pp.33-38
    • /
    • 2010
  • The perimeter zone is space which receives a significant effect of ambient condition, it is necessary to improve the thermal performance in order to building energy saving. For this reason, a lot of study about the active approach is being performed, such as perimeter-less air conditioning system. But the performance of the perimeter zone is necessary to improve, through the passive approach. Therefore, the purpose of this study is to provide basic materials of energy-saving design of perimeter zone, based of the PAL that simulation changing the thickness of insulation and the rate of windows.

Why Are Peak Loads Observed during Winter Months in Korea?

  • KIM, JEE YOUNG;OH, HYUNGNA;CHOI, KYUNG-MEE
    • KDI Journal of Economic Policy
    • /
    • v.41 no.1
    • /
    • pp.43-58
    • /
    • 2019
  • Since 2009, electricity consumption has developed a unique seasonal pattern in South Korea. Winter loads have sharply increased, and they eventually exceeded summer peaks. This trend reversal distinguishes these load patterns from those in the USA and the EU, where annual peaks are observed during the summer months. Using Levene's test, we show statistical evidence of a rise in temperature but a decrease in variance over time regardless of the season. Despite the overall increase in the temperature, regardless of the season there should be another cause of the increased demand for electricity in winter. With the present study using data from 1991 to 2012, we provide empirical evidence that relatively low electricity prices regulated by the government have contributed significantly to the rapid upward change in electricity consumption, specifically during the winter months in the commercial sector in Korea.

Evaluating Changes and Uncertainty of Nitrogen Load from Rice Paddy according to the Climate Change Scenario Multi-Model Ensemble (기후변화시나리오 다중모형 앙상블에 따른 논 질소 유출 부하량 변동 및 불확실성 평가)

  • Choi, Soon-Kun;Jeong, Jaehak;Yeob, So-Jin;Kim, Minwook;Kim, Jin Ho;Kim, Min-Kyeong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.5
    • /
    • pp.47-62
    • /
    • 2020
  • Rice paddy accounts for approximately 52.5% of all farmlands in South Korea, and it is closely related to the water environment. Climate change is expected to affect not only agricultural productivity also the water and the nutrient circulation. Therefore this study was aimed to evaluate changes of nitrogen load from rice paddy considering climate change scenario uncertainty. APEX-Paddy model which reflect rice paddy environment by modifying APEX (Agricultural Policy and Environmental eXtender) model was used. Using the AIMS (APCC Integrated Modeling Solution) offered by the APEC Climate Center, bias correction was conducted for 9 GCMs using non-parametric quantile mapping. Bias corrected climate change scenarios were applied to the APEX-Paddy model. The changes and uncertainty in runoff and nitrogen load were evaluated using multi-model ensemble. Paddy runoff showed a change of 23.1% for RCP4.5 scenario and 45.5% for RCP8.5 scenario compared the 2085s (2071 to 2100) against the base period (1976 to 2005). The nitrogen load was found to be increased as 43.9% for RCP4.5 scenario and 76.0% for RCP8.5 scenario. The uncertainty analysis showed that the annual standard deviation of nitrogen loads increased in the future, and the maximum entropy indicated an increasing tendency. And Duncan's analysis showed significant differences among GCMs as the future progressed. The result of this study seems to be used as a basis for mid- and long-term policies for water resources and water system environment considering climate change.