• Title/Summary/Keyword: Androhep

Search Result 8, Processing Time 0.023 seconds

Effect of BTS and Androhep during Storage Times on the Kinematics and Capacitation Status in Liquid Boar Semen (BTS와 Androhep이 보존 기간 동안 액상 정액의 운동역학 및 수정능 획득에 미치는 영향)

  • Kim, Yun-Hee;Park, Yoo-Jin;Yoon, Sung-Jae;Kwon, Woo-Sung;Kim, Sang-Hyun;Pang, Myung-Geol
    • Reproductive and Developmental Biology
    • /
    • v.34 no.3
    • /
    • pp.241-246
    • /
    • 2010
  • The objective of this study was to investigate the effect of storage time on fresh boar semen in Androhep and Beltsville Thawing Solution (BTS). Boar semen samples extended in each extender were stored at $17^{\circ}C$ up to 4 days. Sperm motility kinematics was evaluated by computer assisted sperm analyzer (CASA) and capacitation status by chlortetracycline (CTC)/Hoechst 33258 staining. Sperm motility (%) was not decreased during storage in BTS and Androhep. No significant difference between extenders was observed. Only significant differences in kinematic parameters on linearity during storage were found. The percentage of dead sperm significantly decreased during storage (p<0.05). Also the percentage of noncapacitated, capacitated, and acrosome-reacted sperm significantly modified during storage (p<0.05). However, there was no significant difference between extenders except proportion of capacitated sperm. This finding supported that modification in these parameters was not significantly different between extenders during this short-term storage. Our finding strongly indicated that both Androhep and BIS maintained favorable conditions for motility, motility kinematics, and capacitation status during short-term storage. Despite modifications in some parameters were apparent during sperm storage in extenders, these may not affect the fertilizing capacity of boar semen.

Effect of Extender, Preservation Temperature and Period of liquid Boar Semen on Semen Characteristics and Reproductive Performance (돼지 액상정액의 보존액, 보존온도 및 기간이 정액성상과 번식성적에 미치는 영향)

  • 김인철;이장희;김현종;박창식
    • Korean Journal of Animal Reproduction
    • /
    • v.26 no.1
    • /
    • pp.9-16
    • /
    • 2002
  • This study was carried out to investigate the effects of extenders such as Beltsville thawing solution(BTS), Modena and Androhep, preservation temperature and period of liquid boar semen on semen characteristics and reproductive performance. Boars were raised at Swine Artificial Insemination Center in National Livestock Research Institute, Sunghwan, Chungnam, Korea. This experiment was carried out from 1995 to 2000. The results obtained were summarized as follows. 1. Sperm motility in the samples with Androhep and BTS reduced from day 5 and in the samples with Modena reduced from day 3 of storage. pH or 3 extenders varied from 6.24 to 7.04 during day 1 to 5 of storage. Farrowing rate of sows inseminated with liquid boar semen offended with BTs, Modena and Androhep extenders did not show any differences until day f after semen collection. Sows inseminated with Androhep extender had better farrowing rates (P<0.05) than those with Modena extender at day 1 or 5 after semen collection, but farrowing rates after AI using BTS did not differ compared to those Androhep and Modena. Litter size did not show any differences among the three extenders, but Androhep had the decreased litter size from day i of storage. 2. Motility and normal acrosome of the sperm preserved at 5$^{\circ}C$ did not show any differences until day 4 of storage, but those at 17$^{\circ}C$ changed from day 3 and 4, respectively. Farrowing rate of sows artificially inseminated with liquid boa. semen preserved at 17$^{\circ}C$ had higher, than at 5$^{\circ}C$ (p<0.05), but there was no significant differences in litter size. Farrowing rates and litter size were decreased from day 2 and day 3 of storage at 17$^{\circ}C$, respectively. Farrowing rate of sows inseminated with the preserved semen at 5$^{\circ}C$ did not changed until day 4, but the litter size at 5$^{\circ}C$ was lower than that at 17$^{\circ}C$.

The Effects of Cryoprotectants on Motility and Viability Kinetics of Liquid Boar Semen at $4^{\circ}C$ (액상 보존액 내 동결 보호제가 $4^{\circ}C$에 보관된 액상 돼지 정액의 운동성과 생존성에 미치는 효과)

  • Jeon, Yu-Byeol;Park, Kwang-Woo;Kwak, Seong-Sung;Jeong, Seung-A;Yoon, Jun-Chul;Hyun, Sang-Hwan
    • Journal of Embryo Transfer
    • /
    • v.27 no.1
    • /
    • pp.51-55
    • /
    • 2012
  • The objective of this study was to investigate the motility and kinematics of boar sperm that while stored at 4C. The samples of fresh boar semen were place into an extender, Androhep, and stored at $4^{\circ}C$. In three of these samples, cryoprotectants were added. The sperm's motilities and kinematics were evaluated by using microscope (${\times}400$) and the viability status was evaluated by using with eosin staining method. The 5 sample groups are; Goup A:Androhep (extender), stored at $17^{\circ}C$. Group B:Androhep (extender), stored at $4^{\circ}C$. Group C:Androhep (extender), + 3% glycerol (cryoprotectant), stored at $4^{\circ}C$. Group D:Androhep (extender), + 3% DMSO (cryoprotectant), stored at $4^{\circ}C$. Group E:Androhep (extender), + 3% ethylene glycol (cryoprotectant), stored at $4^{\circ}C$. In group A, the sperm's motility was reduced. On day one the sperm's motility was ($85.7{\pm}2.3$) and day 5 the motility was ($43.9{\pm}3.3$). In group B, C and D the sperm's motility were reduced to 0 on day 5. In group E the sperm's percentage of motility decreased. On day one the sperm's motility was ($42.0{\pm}0.5$) and day 5 the motility was ($2.3{\pm}0.3$). When comparing cryoprotectant in samples of boar sperm there is a slight improvement in the results when the use of Androhep Lite (extender), + 3% ethylene glycol (cryoprotectant), stored at $4^{\circ}C$ are used. Based on these results, ethylene glycol can protect sperm from heat shock at $4^{\circ}C$, but not satisfactory level. However, it showed the possibilities of liquid semen preservation at $4^{\circ}C$ by using cryoprotectant.

A Study on Extender and Lower Temperature Storage for Fresh-extended Porcine Semen (돼지 액상정액을 위한 희석액 및 저온보존에 관한 연구)

  • 김명철;김용준;조정곤;이수진;이재일;김인철;손동수
    • Journal of Veterinary Clinics
    • /
    • v.18 no.4
    • /
    • pp.345-349
    • /
    • 2001
  • The aim of this study was to investigate the effect of sperm preservation according to the various kinds of commercially available semen extenders and to investigate the effect of sperm preservation according to the various temperature storages of fresh-extended porcine semen. To investigate the effect of sperm preservation according to the various kinds of commercially available semen extenders, porcine semens diluted in 3 semen extenders, Beltsville Thawing Solution(BTS), Androhep and Kiev, were cooled at $8^{\circ}C$ storage temperature with a controlled cooling rate of $2-4^{\circ}C$/h. Motility, progressive motility, normal sperm(%) and sperm morphology were assessed comparatively. In motility and progressive motility, Androhep extenders revealed better result than other extenders. In normal sperm(%) and sperm morphology, 3 semen extenders revealed similar results. To investigate the effect of sperm preservation according to the various temperature storages of fresh-extended porcine semen, porcine semens diluted in BTS extender, were cooled at 3 storage temperatures($8^{\circ}C$, $12^{\circ}C$ and $17^{\circ}C$) with a controlled cooling rate of $2-4^{\circ}C$/h. Motility, progressive motility, normal sperm(%) and sperm morphology were assessed comparatively. In motility and progressive motility, $8^{\circ}C$ treatment group revealed better result than $12^{\circ}C$ and $17^{\circ}C$ treatment groups. In normal sperm(%) and sperm morphology, 3 temperatures of treatment groups revealed similar results.

  • PDF

Development of Semen Extenders by Assessment of Sperm Viability in Miniature-Pig Semen

  • Lee S. H.;Cheong H. T.;Yang B. K.;Park C. K.
    • Reproductive and Developmental Biology
    • /
    • v.29 no.4
    • /
    • pp.247-252
    • /
    • 2005
  • The purpose of this study was to assess sperm quality during in vitro storage of miniature-pig semen in order to determine which extender should be used and how extender can be diluted for in vitro storage of miniature-pig semen. Freshly ejaculated miniature-pig's semen was diluted with same volumes of Beltsville Thawing Solution (BTS), Androhep, Modena, Mulberry III and modified-Modena extenders. Sperm quality was evaluated by examining viability, motility, abnormality, acrosome intactness, intensity and capacitation status by chlorotetracycline (CTC) staining. Sperm motility decreased with storage period prolonged and differences among BTS, Androhep, Modena and Mulberry III were apparent On Day 1, approximately 80% of the sperm were motile, but motility decreased to $40\%$ at Day 7. During the 7 days of storage, sperm survival in modified-Modena B extender was higher than another extenders. However, it was not differ significantly among other extenders. The percentage of F and B patterns were not differ significantly among the extenders. However, F pattern in modified-Modena B extender was slightly higher until 3 days of storage than that of Modena extender, modified-Modena A extender and modified-Modena C extender. The percentage of AR patterns in modified-Modena B extender was slightly lower, but did not differ significantly among other extenders. The results of present study suggest that modified-Modena B was effective as new extender for in vitro storage of miniature-pig semen.

Evaluation of Boar Sperm Viability by MTT Reduction Assay in Beltsville Thawing Solution Extender

  • Byuna, J.W.;Choo, S.H.;Kim, H.H.;Kim, Y.J.;Hwang, Y.J.;Kim, D.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.4
    • /
    • pp.494-498
    • /
    • 2008
  • MTT (3-(4, 5-dimethyl thiazol-2-yl)-2, 5-diphenyl tetrazolium bromide) reduction assay is a method that validates the viability of an active cell. Dehydrogenase in mitochondria converts yellow colored insoluble tetrazolium salt to purple colored water-soluble formazan. Sperm also have mitochondria in the midpiece, therefore sperm viability could be evaluated by MTT reduction assay. Several studies have already demonstrated the capability of application of the MTT reduction assay to sperm of several species in Hepes-BSA buffer. Because most liquid semen was diluted in extender like BTS (Beltsville Thawing Solution), Modena or Androhep when it is used or transferred, semen needed another dilution in Hepes-BSA buffer to assess sperm viability. In this study, we evaluated boar sperm viability especially in BTS extended semen and compared the efficiency of this test with eosin-nigrosin staining. We used the fresh BTS extended semen from a local A.I center. Semen sample was diluted to $3.0{\times}10^7$ sperms/ml in BTS. The rates of formazan production were measured in 96-well microtiter plates immediately and 1h after incubation at $17^{\circ}C$ using a spectrophotometer at wave length 560 nm. Simultaneously, split samples of the same semen were tested, using eosin-nigrosin staining to compare the efficiency of the MTT assay of sperm viability in BTS. The correlation between the results of these tests was calculated using Student-t test and ANOVA. The results revealed a strong correlation between the results of MTT reduction rate and the results that were simultaneously determined by eosin-nigrosin staining at 1 h. In conclusion, the MTT reduction test was an effective and simple method to validate sperm viability and it could be used as a simple tool to evaluate sperm viability in the local A.I center and laboratory.

Effect of Storage in Different Commercial Semen Extenders on the Motility, Viability and Fertility In Vitro of Boar Spermatozoa (수퇘지 정자의 운동성, 생존성 및 체외수정 능력에 대한 시판 액상 정액 보존액과 보존 기간의 영향)

  • Sa, Soo-Jin;Kim, Myung-Jick;Cho, Kyu-Ho;Kim, Du-Wan;So, Kyoung-Min;Chung, Ki-Hwa;Son, Jung-Ho;Kim, In-Cheul
    • Reproductive and Developmental Biology
    • /
    • v.35 no.3
    • /
    • pp.203-207
    • /
    • 2011
  • The objective of this study was to determine the effect of semen extenders on the motility, viability and fertility in vitro of spermatozoa during storage of fresh boar semen diluted in different commercial extenders used for pig artificial insemination (AI). In this experiment, semen were diluted in Androhep plus, Beltsville Thawing Solution (BTS), Modena, Seminark and Vitasem LD. Five ejaculates were collected from three Duroc boars and sub-samples were diluted ($30{\times}10^6$ spermatozoa/ml) in different extenders. Semen was stored at $170^{\circ}C$ for 10 days. Sperm motility and viability was assessed using Computer-Assisted Semen Analysis (CASA) and flow-cytometry on 1, 3, 5 and 10 day post collection The motility of spermatozoa stored in different extenders was gradually decreased by increasing the duration of storage of semen. However, there was not significant1y different in the sperm motility and viability among other extenders. On the other hand, the in vitro-matured oocytes were fertilized and cultured in vitro to assess the fertility of boar spermatozoa stored for 3 and 10 days in different extenders. The percentage of morula and blastocyst were taken as indicators of fertility in vitro of spermatozoa. Therefore, there were no differences in the rate of embryos developed to the molular and blastocyst stage. There were no differences in the motility and fertility in vitro among 5 kinds of commercial boar semen extenders.

Effects of Storage in Different Commercial Semen Extenders on Sperm Motility, Viability and Membrane Integrity of Korean Native Boar Spermatozoa

  • Sa, Soo-Jin;Kim, In-Cheul;Choi, Sun-Ho;Hong, Joon-Ki;Kim, Du-Wan;Cho, Kyu-Ho;Kim, Young-Hwa;Chung, Ki-Hwa;Park, Jun-Cheol
    • Journal of Embryo Transfer
    • /
    • v.28 no.4
    • /
    • pp.349-353
    • /
    • 2013
  • The objective of this study was to compare the effect of semen extenders on the sperm motility, viability, acrosome integrity and functional integrity of plasma membrane (HOST: hypo-osmotic swelling test) during liquid preservation of Korean Native boar semen. In this experiment, semen was diluted in Androhep plus, Beltsville Thawing Solution (BTS), ModenaTM, Seminark and Vitasem LD. Sperm-rich fractions were collected from three Korean Native boars and sub-samples were diluted ($30{\times}10^6$ spermatozoa/ml) in different semen extenders. Semen samples were stored at $17^{\circ}C$ for 96 hours. On everyday (0, 24, 48, 72, 96 h) after storage, the sperm characteristics relevant for fertility, such as sperm motility, viability, acrosome integrity and HOST positive were evaluated. The motility of spermatozoa stored in different extenders was no significantly different among other extenders (P>0.05). Also, no difference was observed among samples processed with different extenders in the percentage of sperm viability, acrosome integrity and HOST positive. All extenders maintained a high percentage (70%) of sperm motility, viability and acrosome integrity through 96 h of storage. The result of this study show that there was no significant differences among extenders in their capacity to preserve motility, viability and membrane integrity of spermatozoa from normal, fertile Korean Native boars for 96 h of liquid preservation at $17^{\circ}C$.