• Title/Summary/Keyword: Andong Reservoir

Search Result 101, Processing Time 0.027 seconds

Effect of Environmental Factors on the Growth of Microcystis aeruginosa (Cyanobacteria) in Agricultural Reservoirs (농업용 저수지에서 환경 요인이 Microcystis aeruginosa (cyanobacteria) 성장에 미치는 영향)

  • Kwon, O-Chang;Park, Jung-Won;Chung, Gyu-Young;Lee, Jong-Eun;Seo, Eul-Won
    • Journal of Life Science
    • /
    • v.21 no.8
    • /
    • pp.1183-1189
    • /
    • 2011
  • The present study is aimed at examining the effects of the physico-chemical environmental factors of water systems on water bloom at Homin and Gagok reservoirs in Pungcheon-Myeon, Andong, Gyeongsangbuk-do. The mean water temperature and the contents of chlorophyll-a, total-nitrogen, total-phosphorus and phosphate-phosphorus were higher at the Gagok reservoir. On the other hand, the pH mean value was higher at the Homin reservoir. The mean value of microelements (Na, K, Mg, Fe, Si) was higher at the Gagok reservoir. The cyanobacteria which was considered to be the cause of water bloom at the two reservoirs was Microcystis aeruginosa. It started to grow in May and showed the highest standing crop in August. Between the increase of standing crop of M. aeruginosa and the water quality, correlation values of $Na^+$ (r=-0.910, p<0.05), $Fe^{2+}$ (r=-0.855, p<0.05) and $Si^{4+}$ (r=0.989, p<0.01) at the Homin reservoir increased amount of standing crop. Meanwhile, at the Gagok reservoir, the contents of $Na^+$ (r=-0.776, p<0.05), $Si^{4+}$ (r=0.899, p<0.05) were highly related to the increase of standing crop. Interestingly, Si, which is the limiting factor for diatoms, has a high correlation with standing crop of cyanobacteria. In conclusion, the water blooming is caused not by a simple factor but a synergistic effect due to complex actions including high concentrations of nitrogen and phosphorus ions and many other environmental factors.

Dynamics of Phytoplankton Community by the Water Depth in Andong Reservoir (안동호의 수심에 따른 식물플랑크톤 군집비교)

  • Park, Jung-Won;Yu, Sam-Hwan;Kim, Soon-Young;Lee, Jong-Eun;Seo, Eul-Won
    • Journal of Life Science
    • /
    • v.18 no.9
    • /
    • pp.1249-1256
    • /
    • 2008
  • We investigated the effect of the water quality on the phytoplankton community in the 2 sites of Andong reservoir. The water temperature in 1 m and 4 m depth (LH) was changed, but the temperature in 7 m depth (HD) was constant irrespective of the season. The dissolved oxygen in LH was lower than that of the HD. The turbidity of water and pH were similar in both depths. The concentration of chlorophyll-a decreased with increased depth of water. Fifty nine phytoplankton taxa were identified and the most abundant phytoplankton group was Chlorophyceae with 25 taxa (43%). Cyanophyceae and Bacillariophyceae consisted of 17 taxa (29%) and 10 taxa (17%), respectively. Cryptophyceae had 3 taxa (5%) and Synurophyceae and Dinophyceae had 2 taxa (3%) in Andong reservoir. Dominant species were Elakatothrix gelatinosa (Aug, 23) and Eutetramorus fottii (Aug. 23 and Sep. 28) from Chlorophyceae, Aphanizomenon cf. flos-aquae (Aug. 16), Microcystis aeruginosa (all sampling periods), and Aphanocapsa delicatissima (Oct. 27) from Cyanophyceae, and Cyclotella stelligera (Oct. 13), Cyclotella sp. (Oct. 13 and Oct. 27) and Synedra acus (Aug. 16) from Bacillariophyceae.

Application of CE-QUAL-W2 [v3.2] to Andong Reservoir: Part I: Simulations of Hydro-thermal Dynamics, Dissolved Oxygen and Density Current

  • Bhattarai, Prasid Ram;Kim, Yoon-Hee;Heo, Woo-Myoung
    • Korean Journal of Ecology and Environment
    • /
    • v.41 no.2
    • /
    • pp.247-263
    • /
    • 2008
  • A two-dimensional (2D) reservoir hydrodynamics and water quality model, CE-QUAL-W2, is employed to simulate the hydrothermal behavior and density current regime in Andong Reservoir. Observed data used for model forcing and calibration includes: surface water level, water temperature, dissolved oxygen and suspended solids concentration. The model was calibrated to the year of 2003 and verified with continuous run from 2000 till 2004. Without major adjustments, the model accurately simulated surface water levels including the events of large storm. Deep-water reservoirs, like Andong Reservoir, located in the Asian Monsoon region begin to stratify in summer and overturn in fall. This mixing pattern as well as the descending thermocline, onset and duration of stratification and timing of turnover phenomenon were well reproduced by the Andong Model. The temperature field and distinct thermocline are simulated to within $2^{\circ}C$ of observed data. The model performed well in simulating not only the dissolved oxygen profiles but also the metalimnetic dissolved minima phenomenon, a common1y occurring phenomenon in deep reservoirs of temperate regions. The Root Mean Square Error (RMSE) values of model calibration for surface water elevation, temperature and dissolved oxygen were 0.0095 m, $1.82^{\circ}C$, and $1.13\;mg\;L^{-1}$, respectively. The turbid storm runoff, during the summer monsoon, formed an intermediate layer of about 15 m thickness, moved along the metalimnion until being finally discharged from the dam. This mode of transport of density current, a common characteristic of various other large reservoirs in the Asian summer monsoon region, was well tracked by the model.

Optimal Operation of Single Multi-Purpose Reservoir (단일다목적 저수지의 최적운영)

  • 이순택;이수식
    • Water for future
    • /
    • v.18 no.4
    • /
    • pp.347-359
    • /
    • 1985
  • This study aims at the development of DP-Model for the establishment of monthly optimal operation policy of single multi-puppose reservoir by which the water demand of downstream can be satisfied under the various physical constraints. Series, A. B. C. of inflow are selected out of future monthly inflow data which are simulated form the past monthly average inflow of Andong dam site. the neight possible alternatives in each inflow series are established in order that Andong dam can supply the water demand of Nagdong main stream of 30% to 100%. Nextly, the reservoir rule curves is derived for each alternative by the detailed seguential analysis of stroage, future inflow and water demand based on the reservoir continuite equation. Then, and alternative which can satisfy the objective function of system based on the rule curves in the exteream is determined as an optimal operation policy from the application of developed DP=Model.

  • PDF

The Study of Reservoir Operation for Drought Period (가뭄기간의 저수지 운영방안에 관한 연구)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.13 no.12
    • /
    • pp.1041-1048
    • /
    • 2004
  • In this study the results of optimal water supply analysis by operating constraints of reservoirs during drought period are as follows. During drought period, water supply reliability is possible about $97\~61{\%}$ by CASE 1-CASE 5. Water supply reliability is possible about $97.3{\%}$ in case of the Andong dam and $87.7{\%}$ in case of the Imha dam by CASE 3. Also, under the constraints of CASE 4, water supply reliability is possible about $87.5{\%}$ in case of the Andong dam and $73.3{\%}$ in case of the Imha dam. The reason what low of available water supply ratio is decreased inflow of Imha dam. When compare standard deviation of average storage with standard deviation of storage, stable storage can be secured during successive drought period. And it also can minimize shortage of water during drought. therefore, it is impossible that reservoir supply sufficient water but change of operating condition is better than pervious on that followed by full reservoir level. It is need that the study for optimal water supply during drought period has to be continued.

Dynamics of High Turbid Water Caused by Heavy Rain of Monsoon and Typhoon in a Large Korean Reservoir (Andong Reservoir) (인공호에서 몬순과 태풍 강우에 의한 고탁수층의 이동과 소멸특성)

  • Park, Jung-Won;Shin, Jae-Ki;Lee, Hee-Moo;Park, Jae-Chung
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.1 s.110
    • /
    • pp.105-117
    • /
    • 2005
  • During the period of heavy rain from 2002 to 2004, the characteristics of the inflow, temporal and spatial fluctuations of high turbid water according to thermal stratification were studied on the Andong Reservoir which is the largest artificial lake in the Nakdong River basin, Korea. Thermal stratification was formed in June. Its structure determined to the pathway of inflowing turbid water and has affected by the transportation of high turbid water. Regardless of the time and amount of inflow, the high turbid water showed the shape of underflow at the riverine zone, separated from the bottom at the transition zone and moved to the lacustrine zone with the shape of density current. The plunging point depended on the time and amount of inflow. The distributions of thermal stratification and DO concentrations were changed by inflowing discharge. Two thermoclines and minimum DO layers were found out existing at metalimnion in a specific time, respectively. The layer of high turbid water which formed with the thickness of 20 m at the maximum below the depth of 15 m moved toward dam. Not settled to the bottom, the newly formed layer was discharged through the intake-outlet and dispersed into all layers by the circulation in the fall.

Comparative Analysis of Long-term Water Quality Data Monitored in Andong and Imha Reservoirs (안동호와 임하호에서 관측한 장기 수질자료의 비교 분석)

  • Park, Sun-Jae;Choi, Seong-Mo;Park, Jong-Seok;An, Kwang-Guk
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.1 s.115
    • /
    • pp.21-31
    • /
    • 2006
  • The objectives of this study were to analyze trends of temporal water quality and trophic state in Andong and Imha reservoirs using chemical dataset during 1993 ${\sim}$ 2004, obtained from the Ministry of Environment, Korea. According to long-term limnological analyses, Suspended solids (SS) in Imha Reservoir were 2 ${\sim}$ 8 fold2 greater, than those in SS of Andong Reservoir, and the high solids increased total phosphorus (TP) and biological oxygen demand ($BOD_5$) and decreased the transparency, measured as Secchi depth (SD). Chlorophyll-a (CHL-a) increased little or decreased slightly in the both reservoirs during the high solids, resulting in reduced yields of CHL-a : TP ratios. The deviation analysis of Trophic State Index (TSI) in Imha Reservoir showed that about 70% of TSI (CHL-a)-TSI (SD) and TSI (CHL-a)-TSI(TP) values were less than zero and the lowest values were-60, indicating that influence of inorganic solids (or non-volatile solids) on phytoplankton growth was evident in Imha Reservoir and the impact was greater than that of Andong Reservoir. Inorganic solids in Imha Reservoir resulted in light limitation on phytoplankton growth and thus contributed variations in the relations among three parameters of trophic state index. Especially, seasonal data analysis of nutrients in both reservoirs showed that during the postmonsoon, mean TP concentration was Imha Reservoir greater in than that in Andong Reservoir. The higher TP concentrantion was mainly attributed to increases of inorganic solids from soil erosions and nonpoint source inputs within the watershed. The high inorganic turbidity in Imha Reservoir should be reduced for the conservation of water quality for, especially a tap water supply.

A Study on Estimate of Evaluation Indices of Water Supply Capacity for Multipurpose Dam (다목적댐의 응수공급능력 평가지표 산정에 관한 연구)

  • Cha, Sang Hwa;Park, Gi Beom
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.197-204
    • /
    • 2004
  • In this study analyzed the reliability indices against the water supply ability of Andong dam. The water supply analysis of Andong dam used the HEC-5 model. So Andong dam simulated planed water-supply capacity of Andong dam as increase and decrease +5% ~ -5% of water supply quantity. Water-supply capacity of Andong dam estimated, deficit occurrence, deficit quantity, deficit period. As the results estimated reliability(occurrence based, time based, quantity based) and resiliency vulnerability and with water supply capacity evaluation indices of Andong dam. Also reliability(occurrence based, time based, quantity based), resiliency, vulnerability and resiliency indices are estimated to evaluated the performance of water supply on Andong dam, and their relationships are evaluated.

Analysis of Small reservoir system by Flood control ability augmentation (치수능력 증대에 따른 저수지시스템 분석)

  • Park Ki-Bum;Lee Soon-Tak
    • Journal of Environmental Science International
    • /
    • v.14 no.11
    • /
    • pp.995-1004
    • /
    • 2005
  • As a research establish reservoir safety operation for small dam systems. This study presents hydrologic analysis conducted in the Duckdong and Bomun dam watershed based on various rainfall data and increase inflow. Especially the Duckdong dam without flood control feature are widely exposed to the risk of flooding, thus it is constructed emergency gate at present. In this study reservoir routing program was simulation for basin runoff estimating using HEC-HMS model, the model simulation the reservoir condition of emergency Sate with and without. At the reservoir analysis results is the Duckdong dam average storage decrease $20\%$ with emergency gate than without emergency gate. Also, the Bomun dam is not affected by the Duckdong flood control augmentation.