• 제목/요약/키워드: Anchorage Capacity

검색결과 141건 처리시간 0.024초

국내 지진동 특성에 대한 기기 용접 정착부의 비탄성에너지 흡수계수를 고려한 지진취약도 평가 (Seismic Fragility Analysis of Equipment Considering the Inelastic Energy Absorption Factor of Weld Anchorage for Seismic Characteristics in Korea)

  • 임승현;김건규;최인길;곽신영
    • 한국지진공학회논문집
    • /
    • 제27권1호
    • /
    • pp.69-75
    • /
    • 2023
  • In Korea, most nuclear power plants were designed based on the design response spectrum of Regulatory Guide 1.60 of the NRC. However, in the case of earthquakes occurring in the country, the characteristics of seismic motions in Korea and the design response spectrum differed. The seismic motion in Korea had a higher spectral acceleration in the high-frequency range compared to the design response spectrum. The seismic capacity may be reduced when evaluating the seismic performance of the equipment with high-frequency earthquakes compared with what is evaluated by the design response spectrum for the equipment with a high natural frequency. Therefore, EPRI proposed the inelastic energy absorption factor for the equipment anchorage. In this study, the seismic performance of welding anchorage was evaluated by considering domestic seismic characteristics and EPRI's inelastic energy absorption factor. In order to reflect the characteristics of domestic earthquakes, the uniform hazard response spectrum (UHRS) of Uljin was used. Moreover, the seismic performance of the equipment was evaluated with a design response spectrum of R.G.1.60 and a uniform hazard response spectrum (UHRS) as seismic inputs. As a result, it was confirmed that the seismic performance of the weld anchorage could be increased when the inelastic energy absorption factor is used. Also, a comparative analysis was performed on the seismic capacity of the anchorage of equipment by the welding and the extended bolt.

강한 기둥-약한 보로 설계된 철근 콘크리트 골조구조의 변형성능 평가에 관한 연구 (Evaluation on the Deformation Capacity of RC Frame Structure with Strong Column-Weak Beam)

  • 서수연;이리형;진세옥;최윤철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.225-233
    • /
    • 2003
  • 최근 성능에 근거한 설계법의 개발과 더불어, 변위설계에 대한 관심이 증가하고 있다. 본 연구에서는 다층 RC 골조의 변위성능을 보다 정확하게 평가할 수 있는 방법을 제시하고자 한다. 이를 위해, 골조의 횡변위를 계산하기 위해서 보와 기둥의 변형뿐만 아니라 정착부와 조인트 부분의 변형을 변위 산정시 고려하였다. 기존의 실험 및 계산결과의 비교로부터, 본 연구에서 제시한 방법의 적합성을 확인하였고, 이를 강한 기둥-약한 보의 설계개념을 설계된 다층 RC골조 건물에 적용하여 그 거동을 예측하였다. 그 결과, 보다 정확한 건물의 변위성능을 평가하기 위해서는 정착부와 조인트의 변형을 반드시 반영하여야 하는 것으로 나타났다.

120, 180 MPa 강섬유 보강 초고성능 콘크리트에 정착된 확대머리철근의 정착강도 (Anchorage Strength of Headed Bars in Steel Fiber-Reinforced UHPC of 120 and 180 MPa)

  • 심혜정;천성철;최석환
    • 콘크리트학회논문집
    • /
    • 제28권3호
    • /
    • pp.365-373
    • /
    • 2016
  • 강섬유 보강 초고성능콘크리트(SUPER Concrete)는 일반 콘크리트에 비해 높은 압축강도와 인장강도를 지닌다. 이러한 특성으로 SUPER Concrete로 제작된 부재는 단면을 크게 줄일 수 있고, 확대머리철근의 정착강도가 향상될 것으로 기대된다. 이 연구에서는 120 MPa, 180 MPa SUPER Concrete로 제작된 외부 보-기둥 접합부에 $4d_b$, $6d_b$의 정착길이를 갖는 확대머리철근의 정착 성능을 평가하였다. 모든 실험체에서 600 MPa 이상의 실제 항복강도가 발현된 후 일부 실험체에서 측면파열파괴가 발생되었다. 확대머리철근의 정착강도가 매우 높아 철근이 파단되는 경우도 있었다. 설계기준강도 120 MPa 이상 SUPER Concrete에 정착된 확대머리철근은 $4d_b$의 짧은 정착길이로 콘크리트구조기준에서 허용하는 철근의 최대 설계기준강도 600 MPa를 발현할 수 있는 것으로 평가되었다. 기존에 개발된 일반 콘크리트에 정착된 확대머리철근의 측면파열파괴강도 평가식과 현행 콘크리트구조 기준의 확대머리철근 정착길이 설계식은 실험값을 과소평가하였다. 일반콘크리트에서 개발된 평가식은 SUPER Concrete의 높은 인장강도 특성을 반영하지 못하기 때문으로 분석된다. 확대머리철근 정착강도를 $(f_{ck})^{\alpha}$에 비례한다고 가정하고 실험결과를 회귀분석하여, SUPER Concrete 압축강도의 0.14승에 비례하는 정착강도 평가식이 개발되었다. 40개 실험 자료에 대한 [실험값]/[예측 값]의 평균은 1.01, 변동계수는 5%였다.

SFRC 부재에 수직 배근된 고강도 확대머리철근의 정착강도 (Anchorage Strength of High Strength Headed Bar Embedded Vertically on SFRC Members)

  • 이창용;김승훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제24권1호
    • /
    • pp.148-156
    • /
    • 2020
  • 본 논문은 강섬유 보강 콘크리트 부재에 수직으로 기계적 정착된 고강도 확대머리철근의 정착성능을 평가하기 위하여 실시한 기초 인발실험결과를 정리한 것이다. 주요 실험변수는 강섬유의 혼입률, 콘크리트 강도, 정착길이, 확대머리철근 항복강도, 전단보강유무 등이다. 실험체의 좌우 순피복두께는 확대머리철근 직경의 두 배로 계획하였다. 확대머리철근을 중심으로 1.5𝑙dt, 0.7𝑙dt가 되는 위치에 힌지 지점을 두고, 확대머리 철근을 직접 인발하였다. 인발실험결과, 실험변수에 따라 콘크리트 파괴 및 철근 인장파단이 나타났다. 강섬유를 보강한 실험체가 동일한 변수의 강섬유를 보강하지 않은 실험체에 비히여 콘크리트 압축강도는 2.7~5.4% 크게 나타난 반면 인발강도는 20.9~63.1% 크게 나타나 정착성능 향상에 큰 기여를 하는 것으로 평가되었다. 강섬유 보강 콘크리트에 대해 확대머리철근과 평행한 전단보강근의 배근은 1.7~7.7% 인발강도를 증가시켰으나, 콘크리트 강도 증가를 고려할 때 정착성능 향상에 미치는 영향이 크지 않았다. 본 실험체 상세와 같이 강섬유보강 콘크리트 부재에 수직정착된 SD600의 확대머리철근 정착설계는 KCI2017, KCI2012의 정착길이 설계식을 그대로 사용할 수 있을 것으로 사료된다.

단일텐던 및 복수텐던이 설치된 프리스트레스트 콘크리트 부재의 정착부 거동 연구 (Mechanical Behavior of Anchorage Zones in Prestressed Concrete Members with Single and Closely-Spaced Anchorages)

  • 오병환;임동환;유승운
    • 대한토목학회논문집
    • /
    • 제14권6호
    • /
    • pp.1329-1339
    • /
    • 1994
  • 본 논문은 복수 정착구가 서로 인접하여 설치되었을 경우의 정착부 거동 및 국부응력 분포특성을 규명함에 목적이 있으며, 이를 위하여 단일텐던 및 복수텐던이 설치된 프리스트레스 콘크리트부재에 대한 실험연구가 수행되었다. 위의 실험연구 결과 정착부 파괴는 단일 및 복수텐던 설치부재 모두 텐던을 따라가는 균열에 의해 시작되며, 먼저 정착된 텐던 정착부 주변의 인장응력은 인접해서 긴장되는 텐던의 압축응력 발생효과로 인하여 균열하중에 대한 저항성이 개선됨이 밝혀졌다. 본 논문에서는 복수텐던 부재의 정착부 주위의 변형도 분포와 균열하중 등을 단일텐던 부재의 경우와 비교분석하여 제시하였으며, 복수텐던부재의 파괴기구도 규명하였다.

  • PDF

Experimental study on RC beams externally bonded by CFRP sheets with and without end self-locking

  • Chaoyang Zhou;Yanan Yu;Chengfeng Zhou;Xuejun He;Yi Wang
    • Steel and Composite Structures
    • /
    • 제48권5호
    • /
    • pp.599-610
    • /
    • 2023
  • To avoid debonding failure, a novel type of hybrid anchorage (HA) is proposed in this study that uses a slotted plate to lock the ends of the fiber-reinforced polymer (FRP) sheet in addition to the usual bonding over the substrate of the strengthened member. An experimental investigation was performed on three groups of RC beams, which differed from one another in either concrete strength or steel reinforcement ratio. The test results indicate that the end self-locking of the CFRP sheet can improve the failure ductility, ultimate capacity of the beams and its utilization ratio. Although intermediate debonding occurred in all the strengthened beams, it was not a fatal mode of failure for the three specimens with end anchorage. Among them, FRP rupture occurred in the beam with higher concrete strength and lower steel reinforcement ratio, whereas the other two failed by concrete crushing. The beam strengthened by HA obtained a relatively high percentage of increase in ultimate capacity when the rebar ratio or concrete strength decreased. The expressions in the literature were inspected to calculate the critical loads at intermediate debonding, FRP rupturing and concrete crushing after debonding for the strengthened beam. Then, the necessity of further research is addressed.

Model test and numerical simulation on the bearing mechanism of tunnel-type anchorage

  • Li, Yujie;Luo, Rong;Zhang, Qihua;Xiao, Guoqiang;Zhou, Liming;Zhang, Yuting
    • Geomechanics and Engineering
    • /
    • 제12권1호
    • /
    • pp.139-160
    • /
    • 2017
  • The bearing mechanism of tunnel-type anchorage (TTA) for suspension bridges is studied. Model tests are conducted using different shapes of plug bodies, which are circular column shape and circular truncated cone shape. The results show that the plug body of the latter shape possesses much larger bearing capacity, namely 4.48 times at elastic deformation stage and 4.54 times at failure stage compared to the former shape. Numerical simulation is then conducted to understand the mechanical and structural responses of plug body and surrounding rock mass. The mechanical parameters of the surrounding rock mass are firstly back-analyzed based on the monitoring data. The calculation laws of deformation and equivalent plastic strain show that the numerical simulation results are rational and provide subsequent mechanism analysis with an established basis. Afterwards, the bearing mechanism of TTA is studied. It is concluded that the plug body of circular truncated cone shape is able to take advantage of the material strength of the surrounding rock mass, which greatly enhances its bearing capacity. The ultimate bearing capacity of TTA, therefore, is concluded to be determined by the material strength of surrounding rock mass. Finally, recommendations for TTA design are proposed and discussed.

정착부 콘크리트 앵커시스템의 설계방법 적합성 평가 (Assessment of Design Methods for the Anchorage Systems Fastening to Concrete)

  • 윤영수;박성균;이성규;김상윤;이상국
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.425-428
    • /
    • 1999
  • This paper presents the evaluation of behavior and the prediction of tensile capacity of anchors that fail concrete, as the design basis for anchorage. Tests of cast-in-place headed anchors, domestically manufactured and installed in uncracked, unreinforced concrete are performed to investigate the behavior of single anchors and multiple anchors with the consideration of various embedment lengths and edge distances.

  • PDF

세장한 고하중 PSC 정착장치의 실험적 연구 (An Experimental Study on a Narrow and High Capacity PSC Anchorage)

  • 전용식;강상훈;진경석;한만엽
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.39-40
    • /
    • 2009
  • 본 연구는 교량의 장경간화와 시공단축을 위하여 전구간이 동일한 단면을 가지며 중공이 있는 중공형 프리캐스트 프리스트레스 콘크리트 분절 거더를 개발하고 실용화하기 위한 정착장치를 개발하기 위함이다.

  • PDF

CFRP 긴장재용 압착형 정착장치의 정착성능에 관한 실험적 연구 (An Experimental Study on the Performance of Compression-Type Anchor for CFRP Tendons)

  • 정우태;이승주;박영환
    • 콘크리트학회논문집
    • /
    • 제20권5호
    • /
    • pp.611-618
    • /
    • 2008
  • CFRP (carbon fiber reinforced polymer) 긴장재는 PS 강연선의 부식문제를 해결하기 위해 대안으로 사용될 수 있다. CFRP 긴장재는 횡방향 압력 및 응력집중에 취약하므로 기존의 PS 강연선에 적용되는 정착시스템의 적용은 조기파괴 등으로 인하여 믿을만한 내하성능을 주지 못한다. 따라서 CFRP 긴장재를 정착하기 위한 알맞은 정착장치의 개발이 필요하다. CFRP 긴장재용 정착구의 주된 형태는 쐐기형, 부착형 및 압착형으로 구분되며 이들 형태는 CFRP 긴장재에서 발생되는 조기파단을 방지하고 국부응력을 적절히 분산시키기 위한 목적으로 개발되고 있다. 본 논문은 CFRP 긴장재를 정착시키기 위해 압착형 정착방식을 적용하여 응력집중을 완화시키기 위해 슬리브 내외경에 변단면을 적용하고, 변단면 길이에 따른 압착형 정착구의 정착성능을 고찰하였다. 실험결과 정착구의 성능은 슬리브 제원과 압착력에 크게 좌우되는 것으로 나타났고, 응력완화구간을 갖는 슬리브는 응력집중을 감소시키는 것으로 나타났다.