• Title/Summary/Keyword: Anatomical structures

Search Result 298, Processing Time 0.029 seconds

Dental CBCT aided diagnosis of periapical and periodontal lesions (임상가를 위한 특집 3 - CBCT를 이용한 치주-근관 복합병소 진단)

  • Lee, Jae-Seo
    • The Journal of the Korean dental association
    • /
    • v.50 no.4
    • /
    • pp.196-202
    • /
    • 2012
  • Radiographic diagnosis of periapical lesions is based on many factors, including anatomical limitations such as thickness of the cortical bone; positioning of the apical abscess to the cortical bone; and is complicated by proximity to other anatomical structures and neighboring teeth. With conventional radiographs, these structures are often superimposed. Dental CBCT with its associated geometric accuracy offers accurate visualizations of the complex relationships and boundaries between teeth, related anatomical features, and their associated pathology. Its images also provide us internal tooth morphology, periodontal ligament space, the presence or absence of periapicl lesions in association wi th critical anatomical structures and maxillary sinus involement. Using 3 D imaging makes it easier for clinicians to detect, diagnosis, and develop highly effective treatment plans. Now, 4 cases of periapical and periodontal pathosis with CBCT images are to be presented including periapical abscess, furcation involvement, periapical pathosis involving maxillary sinus, and osteomyelitis. CBCT analyze specific area of interest and provides the highly detailed anatomical information. It also facilitates earlier and more accurate diagnosis, and treatment planning decisions and more predictable outcome.

A Comparative Study of Radiographic Images on Normal Anatomical Structures (정상 해부학적 구조물에 대한 X-선 영상의 비교 연구)

  • Choi Heang-Hee;Choi Eui-Hwan;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.283-297
    • /
    • 1999
  • Purpose: To compare radiographic images of Digora/sup (R)/ system and Ektaspeed Plus film obtained from normal adults. Materials and methods: Storage phosphor plate(SPP) was placed in a film holder behind Ektaspeed Plus film package without lead foil. The effect of film on SPP was studied in a separate in vitro experiment. Forty-seven sets of images were prepared for the evaluaton. The regions of interest(ROI) for evaluation were designated at seven sites including normal anatomical structures. The image quality for each ROI was evaluated on enhanced and unenhanced storage phosphor(SP) images and Ektaspeed Plus film. Results: Two film-SPP configurations showed significantly different gray levels at each step of the aluminum step wedge(p<0.05). The contrasts were comparable. Enhanced SP images were significantly superior to unenhaned images and film in all anatomical sturctures(p<0.01). The differences between unenhanced SP images and film were significant(p<0.05) except root canal and cortical bone on alveolar crest. For anatomical items. there were statistically significant difference among five observers(p<0.05). Conclusions: The image quality of enhanced SP images were superior to Ektaspeed Plus film. and Digora system is potentially applicable to clinical diagnosis.

  • PDF

Ideal Insertion Position of Ankle Syndesmosis Screw (경비 인대 결합 나사못의 이상적인 삽입부위)

  • Park, Hong-Gi;Moon, Seon-Sang
    • Journal of Korean Foot and Ankle Society
    • /
    • v.6 no.1
    • /
    • pp.60-65
    • /
    • 2002
  • Purpose: The purposes of the present study were to find the ideal insertion position syndesmosis screw and relation to the surrounding anatomical structures when indirectly inserting the screw anteriorly at a 30 angle at 3 cm proximal portion of the ankle join t. Materials and Methods: We performed computed tomography from the axial view in 20 normal individuals at 3 cm proximal portion of the ankle joint and divided the lateral side of the fibula into 4 sections. We drew a line from the middle of each of these 4 sections to the posterolateral tibia at a 30 angle and determined the relationship between each of these lines and the surrounding anatomical structures and confirmed the site at which each of these 4 lines passed through the posterolateral tibia which divided into 3 sections and the site of the fibula at which each of these lines passed through the middle 1/3 portion of the tibia. Results: The posterior 3/4 portion of the fibula that passed through the middle 1/3 portion of the posterolateral tibia in 18 cases. The portion did not approach the surrounding anatomical structures(Peroneal vessels and the muscular portion of FHL). Conclusion: The ideal insertion position of syndesmosis screw at 3 cm proximal portion of the ankle joint at a 30 angle is the posterior 3/4 portion of the lateral side of the fibula, and injury to the surrounding anatomical structures could be avoided when the screw passes through the middle 1/3 portion of the posterolateral tibia.

  • PDF

Three Dimensional MRI and Software for Studying Normal Anatomical Structures of an Entire Body (온몸의 정상 해부구조물을 익히기 위한 3차원 자기공명영상 및 소프트웨어)

  • Lee, Yong-Sook;Park, Jin-Seo;Hwang, Sung-Bae;Cho, Jae-Hyun;Chung, Min-Suk
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.2
    • /
    • pp.117-133
    • /
    • 2005
  • For identifying the pathological findings in magnetic resonance images (MRIs), normal anatomical structures in MRIs should be identified in advance. For studying the anatomical structures in MRIs, a learning tool that includes the followings is necessary. First, MRIs of the entire body; second, horizontal, coronal, and sagittal MRIs; third, segmented images corresponding to the MRIs; fourth, three dimensional (3D) images of the anatomical structures in the MRIs; fifth, software incorporating the MRIs, segmented images, and 3D images. Such a learning tool, however, is hard to obtain. Therefore, in this research, such a learning tool which helps medical students and doctors study the normal anatomical structures in MRIs was made as follows. A healthy young Korean male adult with standard body shape was selected. Six hundred thirteen MRIs of the entire body were scanned (slice thickness 3 mm, interslice gap 0 mm, field of view 480 mm${\times}$480 mm, resolution 512${\times}$512, T1 weighted), and transferred to the personal computer. Sixty anatomical structures in the MRIs were segmented to make segmented images. Coronal, sagittal MRIs and coronal, sagittal segmented images were made. On the basis of the segmented images, forty-seven anatomical structures 3D images were made by manual surface reconstruction method. Software incorporating the MRIs, segmented images, and 3D images was composed. This learning tool that includes horizontal, coronal, sagittal MRIs of the entire body, corresponding segmented images, 3D images of the anatomical structures in the MRIs, and software is expected to help medical students and doctors study the normal anatomical structures in MRIs. This learning tool will be presented worldwide through Internet or CD titles.

  • PDF

Cadaveric study of deep temporal fascia for autologous rhinoplasty grafts: Dimensions of the temporal compartment in Asians

  • Chi, Daekwan;Kim, Jae-Hee;Kim, Taek-Kyun;Jeong, Jae Yong;Shin, Chungmin;Kim, Sunje;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • v.47 no.6
    • /
    • pp.604-612
    • /
    • 2020
  • Background Due to the anatomical complexity of the deep temporal fascia (DTF), practical guidelines for its safe harvest are lacking. However, since the upper temporal compartment (UTC) contains no vital structures, it may provide safe access for DTF harvest. This study aimed to identify the anatomical structures of the temporal compartment in Asian cadavers and to measure their dimensions to enable safe DTF harvest. Methods The anatomical structures surrounding the temporal compartment were identified in 27 hemifaces from 15 Korean cadavers. After dissection, digital images were acquired and craniometric landmarks were placed upon them to identify the boundaries of the temporal compartment. The horizontal and vertical lengths of the temporal compartment were measured and their surface areas were computationally assessed. Subsequently, differences in the results by sex were evaluated. Results The five-layer anatomical structure of the UTC was clearly visualized. The UTC was bounded by the temporal septa superiorly and inferiorly, the innominate fascia laterally, and the DTF medially. No vital structures were present within the UTC. The vertical and horizontal lengths of the UTC were 6.41±0.67 cm and 10.44±0.83 cm, respectively, and the surface area of the UTC was 48.52±5.65 ㎠. No statistically significant differences were observed in any dimensions between male and female patients. Conclusions During rhinoplasty, DTF can be harvested as an autologous graft material from the UTC. An anatomical understanding of the UTC will aid in the safe and simple harvest of a sufficient amount of DTF.

Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: A CBCT-based study

  • Ribas, Beatriz Ribeiro;Nascimento, Eduarda Helena Leandro;Freitas, Deborah Queiroz;Pontual, Andrea dos Anjos;Pontual, Maria Luiza dos Anjos;Perez, Danyel Elias Cruz;Ramos-Perez, Flavia Maria Moraes
    • Imaging Science in Dentistry
    • /
    • v.50 no.4
    • /
    • pp.281-290
    • /
    • 2020
  • Purpose: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). Results: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). Conclusion: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.

USE OF A COMPUTER NAVIGATION SYSTEM FOR OSTEOTOMIES IN THE ORTHOGNATHIC SURGERY: TECHNICAL NOTE (악교정수술 골절단술시 컴퓨터 네비게이션 시스템의 이용: Technical Note)

  • Kim, Moon-Key;Kang, Sang-Hoon;Choi, Young-Su;Kim, Jung-In;Byun, In-Young;Park, Won-Se;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.3
    • /
    • pp.282-288
    • /
    • 2010
  • Surgery with the computer navigation system can make it possible to identify important anatomical structures which are difficult to be confirmed with the naked eye in the operation, and has extended their applications in various surgical fields. The head and neck surgery especially requires detailed anatomical knowledges and these knowledges have influences on postoperative functions and esthetics of a patient. In the orthognathic surgery, we should take osteotomies in the precise locations of the jawbones and move segments to the intended positions. There are so many important anatomical structures around the osteotomy-sites in the orthognathic surgery that the prevention of damage to these structures to obtain satisfactory results without any complication. There are vessels of the pterygoid plexus posterior to the pterygoid plate in the maxilla and the mandibular nerve enters the mandibluar foramen in the mandibular ramus. These locations should be confirmed perioperatively to avoid any injury to these structures. The navigation-assisted surgery may be helpful for this purpose. We performed navigational orthognathic surgeries with preoperative CT images and obtained satisfactory results. The osteotomy was performed in the proper location and damaging the surrounding important anatomical structures was avoided by keeping the saw away from them with the real-time navigation. It may be required to develop proper devices and protocols for the navigation-assisted orthognathic surgery.

Comparing the precision of panoramic radiography and cone-beam computed tomography in avoiding anatomical structures critical to dental implant surgery: A retrospective study

  • Ozalp, Oznur;Tezerisener, Huseyin Alican;Kocabalkan, Burak;Buyukkaplan, Ulviye Sebnem;Ozarslan, Mehmet Mustafa;Kaya, Goksel Simsek;Altay, Mehmet Ali;Sindel, Alper
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.269-275
    • /
    • 2018
  • Purpose: The aim of this study was to evaluate the correlations between measurements made using panoramic radiography and cone-beam computed tomography (CBCT) based on certain anatomical landmarks of the jaws, with the goal of preventing complications due to inaccurate measurements in the pre-surgical planning phase of dental implant placement. Materials and Methods: A total of 56 individuals who underwent panoramic radiography and a CBCT evaluation before dental implant surgery were enrolled in the study. Measurements were performed to identify the shortest vertical distance between the alveolar crest and neighboring anatomical structures, including the maxillary sinus, nasal floor, mandibular canal, and foramen mentale. The differences between the measurements on panoramic radiography and CBCT images were statistically analyzed. Results: Statistically significant differences were observed between the measurements on panoramic radiography and CBCT for all anatomical structures (P<.05). The correlation coefficients (r) between the paired samples obtained from panoramic radiography and CBCT were closely correlated (P<.05), with r values varying from 0.921 and 0.979 for different anatomical regions. Conclusion: The results of this study support the idea that panoramic radiography might provide sufficient information on bone height for preoperative implant planning in routine cases or when CBCT is unavailable. However, an additional CBCT evaluation might be helpful in cases where a safety margin cannot be respected due to insufficient bone height.

Image quality assessment of pre-processed and post-processed digital panoramic radiographs in paediatric patients with mixed dentition

  • Suryani, Isti Rahayu;Villegas, Natalia Salvo;Shujaat, Sohaib;De Grauwe, Annelore;Azhari, Azhari;Sitam, Suhardjo;Jacobs, Reinhilde
    • Imaging Science in Dentistry
    • /
    • v.48 no.4
    • /
    • pp.261-268
    • /
    • 2018
  • Purpose: To determine the impact of an image processing technique on diagnostic accuracy of digital panoramic radiographs for the assessment of anatomical structures in paediatric patients with mixed dentition. Materials and Methods: The study consisted of 50 digital panoramic radiographs of children aged from 6 to 12 years, which were later on processed using a dedicated image processing method. A modified clinical image quality evaluation chart was used to evaluate the diagnostic accuracy of anatomical structures in maxillary and mandibular anterior and maxillary premolar region of processed images. Results: A statistically significant difference was observed between pre and post-processed evaluation of anatomical structures(P<0.05) in the maxillary and mandibular anterior region. The anterior region was found to be more accurate in post-processed images. No significant difference was observed in the maxillary premolar region (P>0.05). The Inter-observer and intra-observer reliability of both pre and post processed images were excellent (>0.82) for anterior region and good (>0.63) for premolar region. Conclusion: The application of image processing technique in digital panoramic radiography can be considered a reliable method for improving the quality of anatomical structures in paediatric patients with mixed dentition.