• Title/Summary/Keyword: Anatomical reduction

Search Result 157, Processing Time 0.024 seconds

경골과 골절의 치료 (Treatment of Tibial Condyle Fracture)

  • 이동철;손욱진;박성혁
    • Journal of Yeungnam Medical Science
    • /
    • 제20권2호
    • /
    • pp.177-186
    • /
    • 2003
  • 교통사고의 증가로 심한 경골 고평부 골절이 점진적으로 증가되는 양상이며, 경골 고평부 골절 후 동반손상의 적절한 치료, 해부학적 정복 및 견고한 고정, 조기 관절운동이 좋은 예후를 보이며 외상성 관절염을 줄일 수 있을 것으로 사료된다.

  • PDF

Acutrak 나사를 이용한 족관절 내과 골절의 치료 (Surgical Treatment of Using Acutrak Screw for Ankle Medial Malleolar Fracture)

  • 김광열;김형천;안수한;윤형조;조성준
    • 대한족부족관절학회지
    • /
    • 제14권1호
    • /
    • pp.84-89
    • /
    • 2010
  • Purpose: The purpose of this study is to evaluate the clinical and radiologic results of using Acutrak screws for treating ankle medial malleolar fracture. Materials and Methods: We reviewed 38 cases of ankle medial malleolar fracture treated with Acutrak screws from February 2005 to May 2008. Results: In clinical result, there were 30 exellent cases, 7 good cases, 1 fair case. In radiologic result, there is no case with reduction loss. Average union time is 10.5 weeks. Conclusion: We conclude that Acutrak screw fixation is a useful method for ankle medial malleolar fracture, there are many advantages in accurate anatomical reduction, small incision, short operative time.

Internal Fixation Using Clavicle Hook Plates for Distal Clavicle Fractures

  • Kim, Kwang-Yul;Kim, Hyung-Chun;Cho, Sung-Jun;Ahn, Su-Han;Kim, Dong-Seon
    • Clinics in Shoulder and Elbow
    • /
    • 제18권1호
    • /
    • pp.21-27
    • /
    • 2015
  • Background: To report the radiological and clinical outcomes of internal fixation using distal clavicle hook plates for distal clavicle fractures. Methods: From April 2008 to December 2012, 32 patients with distal clavicle fractures underwent surgery using an AO hook plate. The reduction was qualified and evaluated according to the radiological findings. The evaluation of the clinical outcomes was performed with the University of California at Los Angeles (UCLA) score, the Korean Shoulder score, and the visual analogue scale (VAS) pain score. Results: By radiological evaluation, we found that 31 of 32 patients showed anatomical reduction and solid bone union. Although we obtained satisfactory UCLA scores, Korean Shoulder Scale scores, and VAS pain scores, 12 cases of complications were present. We found 4 cases of osteolysis of the acromion, 1 case of nonunion, 3 cases of periprosthetic fractures, 3 cases of subacromial pain, and 1 case of skin irritation. We performed re-operations in 2 patients. Conclusions: To avoid complications associated with clavicle hook plates, choosing the appropriate hook size and bending of the hook according to the slope of the acromion undersurface is critical. Also, we believe that early removal of clavicle plates may help reduce complications.

시중 컴프레션 티셔츠의 신장 특성에 대한 스크리닝 테스트와 의복압 예측 (A Screening Test of Extensibility and the Prediction of Clothing Pressure for Commercial Compression T-shirts)

  • 김남임;홍경희
    • 한국의류학회지
    • /
    • 제41권6호
    • /
    • pp.1010-1021
    • /
    • 2017
  • Adjustment of clothing pressure for compression wear is critical to the physiological and psychological satisfaction of the wearer; however, there are limited studies on the practical relationship among extensibility of materials, pattern reduction of compression wear and resultant clothing pressure. This study provides consumers and designers with information on clothing pressure using a screening extensibility test suggested by Ziegert and Keil (1988) even for the final products. As the first step, ten commercial products were collected and their size, extensibility and corresponding clothing pressure were analyzed. It was found that clothing pressure around the waist level could be predicted well from the information of Ziegert and Keil's (1988) % extensibility of the material (Z stretch %) and the actual application of Z stretch amount to the pattern reduction rate (applied % of Z stretch), with an $r^2$ of around 0.80, especially at the waist level. However, it was not simple for the case of clothing pressure around the back of the chest level due to the various design variation and the complexity of the anatomical structure around the trapezius.

족관절의 후외상성 외반관절염에 대한 비골연장술 및 종골 절골술: 증례 보고 (A Fibular Lengthening Osteotomy Combined with Calcaneal Osteotomy for Post-Traumatic Valgus Ankle Arthritis: A Case Report)

  • 이규헌;서진수;최준영
    • 대한족부족관절학회지
    • /
    • 제26권3호
    • /
    • pp.143-147
    • /
    • 2022
  • Past research has reported that the common causes of ankle arthritis include trauma, congenital deformity, and degeneration. Among them, fracture-induced post-traumatic arthritis is most common. For patients with ankle fractures, an anatomical reduction is performed through surgical treatment. However, insufficient reduction or malunion of the fracture site may change the alignment of the ankle joint, resulting in valgus or varus deformities. Currently, most operative options for valgus arthritis aim to either restore joint alignment and/or reduce the uneven load on the cartilage. In this report, we would like to share our clinical experience of a patient with posttraumatic valgus ankle arthritis caused by severely comminuted fracture and dislocation. A satisfactory outcome could be obtained with combined fibular lengthening osteotomy and medial displacement calcaneal osteotomy.

심장 전기생리학 검사 시 조건 변화에 따른 환자 피폭 선량 평가 (Evaluation of Patient Exposure Dose during Cardiac Electrophysiology Study under Various Conditions)

  • 고성빈;안성민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권6호
    • /
    • pp.501-508
    • /
    • 2023
  • This study used a adult absorption dose phantom (CIRS model 701-G, USA) made of human equivalent material and the vascular imaging equipment Allura Xper FD 20 (Philips, Netherlands). Optically stimulated luminescent dosimeters (OSLD) were inserted into the anatomical positions corresponding to each organ, and the exposure dose was measured. Dose area product (DAP) and air kerma (AK) measured by the dose meter in the equipment were compared. Continuous imaging was performed at two angles for a total of 20 minutes, with a frame per seconds of 3.75 and 7.5 fps and an FOV of 42 cm, 37 cm, and 31 cm, respectively, under the conditions of fluoflavor I, II, and III, each selected for 5 repetitions. This study was found that selecting a lower fps was the most effective way to reduce patient exposure dose, and adjusting the fluoflavor was a good alternative method for reducing patient exposure dose at high fps. Therefore the method of condition change with the greatest dose reduction effect is to set the minimum FPS and can reduce patient exposure dose according to geometric conditions and fluoflavor characteristics.

Percutaneous Microwave Ablation of Desmoid Fibromatosis

  • Alberto Martinez-Martinez;Jade Garcia-Espinosa;Antonio Jesus Lainez Ramos-Bossini;Fernando Ruiz Santiago
    • Korean Journal of Radiology
    • /
    • 제22권6호
    • /
    • pp.944-950
    • /
    • 2021
  • Objective: To demonstrate the feasibility of percutaneous microwave ablation in desmoid fibromatosis with respect to tumor volume control and improvement in the quality of life. Materials and Methods: Twelve microwave ablations were performed in 9 patients with a histological diagnosis of desmoid fibromatosis between January 2010 and January 2019. The study population included 6 female and 3 male, with an age range of 21-76 years (mean = 46.6 years; standard deviation [SD] = 19.3 years). The mean major axis of the tumors was 10.9 cm (SD = 5.2 cm) and mean lesion volume was 212.7 cm3 (SD = 213 cm3). Their anatomical distribution was as follows: 3 lesions in the thigh, 2 in the gluteus, 2 in the leg and 2 in the periscapular region. We evaluated the reduction in tumor volume and improvement in the quality of life based on the Eastern Cooperative Oncology Group (ECOG) scale. Results: An average tumor volume reduction of 70.4% (SD = 24.9) was achieved, while the quality of life (ECOG scale) improved in 88.9% of patients. Conclusion: Percutaneous microwave ablation may potentially be a safe, effective, and promising technique for controlling tumor volume and improving the quality of life in patients with desmoid fibromatosis.

광범위 외측 도달법을 이용한 관절내 종골 골절의 수술적 치료 (Operative Treatment of Intraarticular Calcaneal Fractures using Extensile Lateral Approach)

  • 정형진;안종국;배서영;정훈
    • 대한족부족관절학회지
    • /
    • 제13권1호
    • /
    • pp.60-67
    • /
    • 2009
  • Purpose: This study was designed to investigate the usefulness of extensile lateral approach for accurate reduction and rigid internal fixation in comminuted intraarticular fractures of calcaneus. Materials and Methods: From October 2002 to May 2007, we managed 55 patients (62 cases) with open reduction and internal fixation using extensile lateral approach. Among these, 38 patients (43 cases) who underwent preoperative and postoperative CT scan were enrolled. All patients were evaluated over 24 months after surgery. Bohler angle and Gissane angle on plain X-ray, displacement and step-off of articular surface of calcaneus on CT scan were measured and we compared the difference between preoperative and postoperative value of them. Clinical results were assessed by using AOFAS Ankle-Hindfoot Scale. Results: The average Bohler angle was restored from $6.8^{\circ}$ to $23.5^{\circ}$ and Gissane angle was improved from $116.4^{\circ}$ to $113.5^{\circ}$ after operation. The average distance of displacement was restored from 4.2 mm to 1.4 mm and step-off of articular surface was recovered from 5.1 mm to 1.3 mm. Clinical results were excellent in 17 cases, good in 18 cases, fair in 3 cases, and poor in 5 cases. 10 cases developed postoperative complications such as skin necrosis, heel pain, limitation of motion of ankle and subtalar arthritis. Conclusion: The extensile lateral approach is valuable for the comminuted intraarticular fractures of calcaneus that enables accurate anatomical reduction and rigid internal fixation by providing direct exposure of subtalar joint.

  • PDF

전위된 견갑골 관절내 골절의 관혈적 정복 및 내고정술 (Open Reduction and Internal Fixation of Displaced Intra-Articular Fractures of the Glenoid)

  • 김승기;박종범;최우성;권영정;장한
    • Clinics in Shoulder and Elbow
    • /
    • 제1권2호
    • /
    • pp.230-235
    • /
    • 1998
  • Fractures of the scapula are relatively uncommon injuries and treatment in the vast majority of cases remains nonsurgical and the results have been quite satisfactory. But the scapular fracture itself may be neglected because of its high incidence of many kinds of associated injuries so its delayed treatment sometimes gives bad and unpredictable results. Although open reduction and internal fixation has been accepted as the treatment of choice for displaced intra-articular fractures in many anatomical regions, there has been no definite treatment principles of surgical indications and approaches in the glenohumeral joint. At our institution, II displaced intra-articular fractures of the glenohumeral joint were treated with open reduction and internal fixation from March 1993 to February 1997. This paper reports the results of treating 11 displaced intra­articular fractures of the glenoid by open reduction and internal fixation. There were 10 men and one woman and the fractures were classified according to Ideberg : Type Ⅰa(4), Type Ⅱ(3), Type Ⅲ(1), Type IV(1), Type Va(1), and Type Vc(1).

  • PDF

Retromandibular reduction of medially dislocated condylar process fractures

  • Lee, Gyu Hyeong;Kang, Dong Hee;Oh, Sang Ah
    • Archives of Plastic Surgery
    • /
    • 제45권1호
    • /
    • pp.23-28
    • /
    • 2018
  • Background Condylar process fractures account for one-third of all mandibular fractures, and the distal fragment is prone to dislocate to the medial side due to the pulling of the lateral pterygoid muscle. Retromandibular approaches are commonly used, but the intraoperative view becomes limited in medially dislocated fractures. This study summarized a series of cases of retromandibular reduction for medially dislocated condylar process fractures and described our supplementary procedure to realign the dislocated condylar process. Methods Nine patients with medially dislocated condylar process fractures underwent surgical correction from January 2012 to December 2016. In 6 of them, it was possible to realign the fractures with a conventional retromandibular approach, but for 3 cases of severe dislocation to the middle cranial fossa, a supplementary transoral procedure was carried out. The angle difference between the ramus and condyle, ramus height, and maximal mouth opening (MMO) were evaluated. Results All 9 cases were restored to the proper anatomical alignment without any major complications, and postoperative images revealed successful union. The angle difference was $8.94^{\circ}{\pm}4.11^{\circ}$ preoperatively, and $0.99{\pm}0.49^{\circ}$ at the 6-month follow-up. The pretreatment ramus height difference was $6.12{\pm}6.09mm$, and the postoperative difference was $0.18{\pm}0.10mm$. These changes after surgery were statistically significant. The MMO before surgery was $11.44{\pm}3.0mm$, and the postoperative MMO was $37.2{\pm}2.9mm$, reflecting a significant increase after reduction. Conclusions Retromandibular reduction is a useful method in medially dislocated condylar process fractures, and additional transoral assistance should be considered to realign condylar processes that severely dislocate to the middle cranial fossa.