• Title/Summary/Keyword: Anatomical locking plate

Search Result 18, Processing Time 0.024 seconds

Anatomical Locking Plate with Additional K-wire Fixation for Distal Clavicle Fracture

  • Nam, Woo-Dong;Moon, Sung-Hoon;Choi, Ki-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.230-235
    • /
    • 2017
  • Background: Neer type II distal clavicle fractures have the drawback of coracoclavicular instability and insufficient distal bony fragment, thereby making it difficult to achieve adequate fixation. Although various surgical treatments have been described for Neer type II fracture, the optimal treatment remains controversial. This study reports the clinical results and usefulness of anatomical locking plate with additional K-wire fixation. Methods: A totally of 21 patients with type II distal clavicle fracture were included in the study. The surgical procedure reduced the fracture temporarily; it included insertion of one or two K-wire from the lateral margin of the distal fragment to the proximal fragment through the fracture site, followed by application and fixation of the locking plate. The bony union and migration of K-wire was evaluated in the follow-up radiography. The coracoclavicular distance and acromioclavicular joint arthrosis were assessed at the final follow-up. The Constant Score (CS) and Korean Shoulder Score (KSS) were evaluated for clinical scoring. Results: Bone union was achieved in all cases. At the final follow-up, coracoclavicular distance of the injured shoulder was increased, as compared to the intact shoulder (p=0.002), with no accompanying clinical symptoms. No K-wire migration was observed. At the final follow-up, K-wire irritation was observed in two cases and acromioclavicular arthrosis in one case, with no other adverse effects. Pain visual analogue scale, CS, and KSS were improved in all cases. Conclusions: The method of anatomical locking plate with additional K-wire fixation could be useful in achieving beneficial clinical results.

Treatment of Fractures of the Lateral Malleolus using Locking Compression Plate (Locking Compression Plate를 이용한 족근 관절 외과 골절의 치료)

  • Ha, Sung-Sik;Hong, Ki-Do;Chung, Nam-Sik;Sim, Jae-Cheon;Ahn, Sang-Cheon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.99-104
    • /
    • 2005
  • Purpose: The purpose of this study was to investigate usefulness of locking compression plate (LCP) as an open reduction technique by evaluating clinical results obtained from the patients with lateral malleolar fracture treated by internal fixation using LCP after open reduction. Materials and Methods: Among the patients with lateral malleolar fracture, the 28 patients who were treated by internal fixation using Locking compression plate after an open reduction and were able to be followed up for more than 6 months were included in this study. Final postoperative evaluation was done based on the Meyer's clinical and radiologic evaluation system. Results: All cases achieved anatomical reduction and fixation of the reduction postoperatively. 28 minutes were taken meaningly from the incision to the fixation of LCP plate after the anatomical reduction. Everage bony union time was 8.2 weaks, and the result was excellent in 23 cases (82%), good in 5 cases (17%) and poor result was abscent according to the criteria of Meyer et al. One case of post traumatic arthritis and one case of superficial infection on the operation site were found, but non-union, delayed union and malunion were not occurred. Conclusion: The internal fixation after open reduction using LCP is an effective treatment method in treating lateral malleolar fracture of the ankle since it offers advantages including easy application and a greater stability due to its capability of maintaining exact anatomical reduction even though the screw does not penetrate the medial cortex of fibular to add the stability and rigidity of the fixation.

  • PDF

Indirect Reduction Technique in Proximal Humeral Fractures Stabilized by Locking Plates

  • Rhee, Yong Girl;Cho, Nam Su;Cha, Sang Won;Moon, Seong Cheol;Hwang, Sang Phil
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.2-9
    • /
    • 2014
  • Background: Indirect reduction technique offers a valid option in the treatment of proximal humerus fracture. The purpose of this study is to evaluate the functional outcome and the complication rate after indirect reduction and internal fixation of unstable proximal humeral fractures with use of a locking plate. Methods: Twenty four patients with acute proximal humerus fracture were managed with indirect reduction and internal fixation with a locking plate. The mean follow-up period was 15.5 months. Results: The anatomical reduction of the medial cortex buttress was seen in 16 patients (66%) of the Group A and the non-anatomical reduction was seen in 8 patients (33%) of the Group B. Mean union time was $3.2{\pm}1.9$ months; it was $2.2{\pm}0.6$ months in the Group A and $5.3{\pm}2.2$ months in the Group B (p < 0.05). In our series, there were 6 cases of complications and these include 2 cases of varus malunion, 2 cases of shoulder stiffness, 1 case of heterotrophic ossification, 2 cases of screw perforation and 1 case of impingement. Conclusions: We conclude from our studies that indirect reduction and internal fixation using locking plate for acute proximal humerus fracture can give good results with bony union and predictable good overall functional outcome. If the medial cortex buttress is well maintained, a better anatomical reduction would be achieved, the union would be prompted, the pain would be further reduced and the range of the motion would be recovered more promptly.

Coracoclavicular Ligament Suture Augmentation with Anatomical Locking Plate Fixation for Distal Clavicle Fracture

  • Lim, Tae Kang;Shon, Min Soo;Ryu, Hyung Gon;Seo, Jae Sung;Park, Jae Hyun;Ko, Young;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.175-180
    • /
    • 2014
  • Background: For Neer type IIB fracture of distal clavicle with coracoclavicular ligament injury, various surgical treatments have been used in literatures. However, there was no consensus on the optimal treatment. The aim of this study is to report the clinical and radiological results of open reduction and internal fixation of unstable distal clavicle fracture and suture augmentation of disrupted coracoclavicular ligament. Methods: A prospective study was performed in 23 patients with Neer type IIB distal clavicle fracture in Seoul Medical Center, Eulji Hospital, and National Medical Center. Firstly, suture anchors are inserted in the base of coracoid process and preliminary reduction was achieved by tie-off of three suture limbs around the clavicle. Then, the final fixation was completed with anatomical locking plate. Bony union and the distance between coracoclavicular ligaments were evaluated. Clinical results and complications including stiffness and secondary procedures were evaluated. Results: Bony union was achieved in all cases except one (22 of 23). At mean 14.9 months, no significant difference in the mean coracoclavicular distance was observed compared to uninjured shoulder ($8.2{\pm}7.9mm$ versus $7.3{\pm}3.4mm$, p=0.14). Pain visual analogue scale, American Shoulder and Elbow Surgeons score, Constant score, and Disabilities of the Arm, Shoulder and Hand score were 0.5, 83.4, 78.5, and 6.2, respectively. Revision surgery was performed in one case of nonunion. Four patients who complained of skin irritation underwent implant removal. Conclusions: In cases of an unstable distal clavicle fracture with coracoclavicular ligament disruption, satisfactory clinical results were obtained by locking plate fixation and coracoclavicular ligament suture augmentation concurrently.

Ulnar Nerve Injury Caused by the Incomplete Insertion of a Screw Head after Internal Fixation with Dual Locking Plates in AO/OTA Type C2 Distal Humerus Fractures

  • Shin, Jae-Hyuk;Kwon, Whan-Jin;Hyun, Yoon-Suk
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.4
    • /
    • pp.236-239
    • /
    • 2017
  • After dual plating with a locking compression plate for comminuted intraarticular fractures of the distal humerus, the incidence of ulnar nerve injury after surgery has been reported to be up to 38%. This can be reduced by an anterior transposition of the ulnar nerve but some surgeons believe that extensive handling of the nerve with transposition can increase the risk of an ulnar nerve dysfunction. This paper reports ulnar nerve injuries caused by the incomplete insertion of a screw head in dual plating without an anterior ulnar nerve transposition for AO/OTA type C2 distal humerus fractures. When an anatomical locking plate is applied to a distal humeral fracture, locking screws around the ulnar nerve should be inserted fully without protrusion of the screw because an incompletely inserted screw can cause irritation or injury to the ulnar nerve because the screw head in the locking system usually has a slightly sharp edge because screw head has threads. If the change in insertion angle and resulting protruded head of the screw are unavoidable for firm fixation of fracture, the anterior transposition of the ulnar nerve is recommended over a soft tissue shield.

The Analysis of the Treatment Outcomes of Proximal Humeral Fractures with Locking Plates

  • Lee, Kwang-Won;Hwang, Yoon-Sub;Kim, Choon-Myeon;Yang, Dae-Suk;Park, Tae-Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.1
    • /
    • pp.10-17
    • /
    • 2014
  • Background: The aim of this study was to assess the clinical outcomes after treatment of proximal humeral fractures with locking plates, and to determine which factors influence the clinical and radiological outcomes. Methods: Fifty six patients who were treated with locking plates for proximal humeral fractures and had been followed for more than 1 year were enrolled in this study. We performed functional evaluation using the Constant score and analyzed radiographic results. The following factors that may potentially influence the clinical outcomes were assessed: age, gender, type of fracture, presence of medial metaphyseal comminution, bone mineral density, anatomical reduction, restoration of medial mechanical support, and postoperative complications. Results: The mean Constant score was 70.1 points at the final follow-up. Female gender, 4-part fractures, AO type-C fractures, and fractures with medial metaphyseal comminution were associated with a poor clinical outcome. On the other hand, restoration of medial mechanical support and accurate anatomical reduction had a positive influence on clinical outcomes. Postoperative complications resulted in 3 patients (intra-articular screw perforation: 1 patient, varus deformity with screw loosening: 1 patient, nonunion: 1 patient). Conclusions: When treating proximal humeral fractures with locking plate fixation, following factors: a female gender, Neer type 4-part fracture, AO type C fracture, and medial metaphyseal comminution are important risk factors that surgeons should take into consideration. Factors that contribute to better clinical outcomes of operative treatment for humeral fractures are accurate anatomical reduction and restoration of medial mechanical support.

Anatomic Conformity of New Periarticular Locking Plates for Koreans: A Biomechanical Cadaveric Study (한국인에 대한 새로운 관절주위 잠김금속판의 해부학적 적합성: 사체를 이용한 연구)

  • Yoon, Yong-Cheol;Oh, Jong-Keon;Kim, Young-Woo;Kim, Hak Jun;Moon, Hong Joo;Kim, Nam-Ryeol
    • Journal of Trauma and Injury
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 2013
  • Purpose: This study was conducted to confirm the anatomic conformity of the new periarticular locking plates designed by Zimmer on Korean adult bones and to identify the structures at risk during the application of these implants. Methods: The study was performed on the humerus, radius, and tibia of 10 adult cadavers(6 males and 4 females) procured from the cadaveric lab of our hospital. Anteroposterior (AP) and lateral X-rays were taken to confirm that the cadavers were free of any unusual lesions or anatomic variations. We used the 3.5-mm proximal humerus plate, 2.7-mm distal radius plate, 3.5- and 5.0-mm proximal tibia plates, and 3.5-mm distal tibia plate developed by Zimmer, Inc. (Zimmer periarticular locking plate). The longest plate from each group was used to confirm anatomical conformity. Standard approaches were used for each area, and soft tissue was retracted in order to pass the plate beneath the muscle. The position of the plate was confirmed using standard AP and lateral view X-rays. After this procedure had been completed, the region was dissected along the length of the implant to determine the conformity of the implant to bone and the penetrations of screws into the articular surface or violations of any vital structures, such as nerves, blood vessels, or tendons. Results: Excellent anatomical conformity was observed with Zimmer periarticular locking plates for Korean adults. The tibial nerve and the posterior tibial artery were found to be structures at risk when applying a distal tibial plate. Conclusion: Additional posterolateral fixation is recommended when dealing with cases of tibial plateau fracture when the fracture line extends to the posterolateral cortex. We recommend taking proper views using 10~15 degrees of internal rotation to ensure correct screw length and, thus, avoid penetration of vital structures and tendons.

Mini-open Treatment Using Plate of Clavicle Mid-shaft Fractures

  • Park, Yong-Geun;Kang, Hyunseong;Kim, Shinil;Bae, Jong-Hwan;Choi, Sungwook
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.1
    • /
    • pp.37-41
    • /
    • 2017
  • Background: Increased frequency of comminuted clavicle mid-shaft fractures and importance of functional satisfaction through early joint exercise has resulted in higher emphasis on surgical treatments. This study aimed to evaluate the clinical radiological results of treatment of clavicle mid-shaft fractures by open reduction and internal fixation using a plate with a small incision. Methods: The subjects of this study were 80 clavicle mid-shaft fracture cases treated with internal fixation using a plate from October 2010 to July 2014. Clavicle mid-shaft fractures were internally fixated using anatomical plates or locking compression plates. Achievement of bone union, union period, and clavicle length shortening were evaluated radiologically, and clinical assessment was done by using Constant and University of California at Los Angeles (UCLA) scores. Results: All 80 cases were confirmed to have achieved bone union through radiographs with an average union period of 10.9 weeks (range: 7-18 weeks). The average clavicle length of shortening in the affected side was 1.8 mm (range: 0-17 mm). The average UCLA score and Constant score were 33.6 (range: 25-35) and 92.5 (range: 65-100), respectively. Regarding complications, four cases reported skin irritation by metal plates, and one case reported a screw insertion site fracture due to minor trauma history. Conclusions: We were able to induce successful bone union and obtain clinically satisfactory results in displaced mid-shaft fractures of the clavicle without major complications such as nonunion through treatment of internal fixation using a plate.

Comparison between Accurate Anatomical Reduction and Unsuccessful Reduction with a Remaining Gap after Open Reduction and Plate Fixation of Midshaft Clavicle Fracture

  • Kim, Joon Yub;Choe, Jung Soo;Chung, Seok Won
    • Clinics in Shoulder and Elbow
    • /
    • v.19 no.1
    • /
    • pp.2-7
    • /
    • 2016
  • Background: The purpose of this study is to compare the radiological and clinical outcomes after open reduction and plate fixation of midshaft clavicle fractures between patients who achieved successful anatomical reduction and those who had a remaining fracture gap even after open reduction and plate fixation, and were thus treated with additional demineralized bone matrix (DBM). Methods: This retrospective analysis was conducted on 56 consecutive patients who underwent open reduction and internal fixation using a locking compression plate for acute displaced midshaft clavicle fractures, and who underwent radiographic and clinical outcome evaluations at least 6 months postoperatively. The outcomes between those who achieved perfect anatomical reduction without remnant gap (n=32) and those who had a remaining fracture gap even after open reduction and plate fixation treated with additional DBM (n=24) were evaluated. Results: There were no differences in the use of lag screws or wiring and operation time (all p>0.05) between those with and without remnant gap. No difference in the average radiological union time and clinical outcomes (satisfaction and Constant score) was observed between the two groups (all p>0.05). However, significantly faster union time was observed for AO type A fracture compared with other types (p=0.012), and traffic accident showed association with worse clinical outcomes compared with other causes of injury. Conclusions: Surgical outcome of midshaft clavicle fracture was more affected by initial fracture type and event, and re-reduction and re-fixation of the fracture to obtain a perfect anatomical reduction spending time appears to be unnecessary if rigid fixation is achieved.

Operative Treatment with Anatomically Preshaped Locking Compression Plate in Distal Fibular Fracture (해부학적 잠김 압박 금속판을 이용한 원위 비골 골절의 치료)

  • Chung, Hyung-Jin
    • Journal of Korean Foot and Ankle Society
    • /
    • v.17 no.2
    • /
    • pp.130-135
    • /
    • 2013
  • Purpose: Preshaped Locking compression plate(LCP) has holes with fixed angle between screw and plate and have advantage firm fixation because it has stability of angular and axial deformity. We evaluated usefulness of LCP after open reduction and internal fixation in distal fibular fracture. Materials and Methods: Between December 2011 and May 2012, 23 patients with fracture of distal fibula were followed up at least 12 months underwent open reduction and internal fixation with LCP. There were 15 males and 8 females with a mean age 39.8(20~69) years. According to Danis-Weber classification, there were 20 cases of type B and 3 cases of type C. There were 13 cases of isolated lateral malleolus fractures, 1 case of bimalleolar fracture, 6 cases of trimalleolar fractures and 3 cases of distal tibia fractures with proximal fibula fracture. Intraoperatively, we assessed whether preshaped LCP fit lateral margin of distal fibula or not and evaluated quality of reduction and postoperative complications. The cases were analyzed by radiological bone union time and clinical results according to the criteria of Meyer Results: Of all cases, complete bone union was achieved and average radiological bone union time was 7.3(6~12) weeks. The clinical results were excellent in 18 cases(78%), good in 5 cases(22%). There were 5 cases of plate with 3 holes, 13 cases of plate with 4 holes, 2 cases of plate with 5 holes, 1 case of plate with 6 holes and 2 cases of plate with 7 holes. The average number of screws at proximal fragement was 2.5 and at distal fragment was 3.5. In 14 cases (60.8 %), we needed re-bending of plate because the distance between plate and lateral cortical margin of distal fibula was more than 5 mm at anteroposterior X-ray after reduction. All cases have anatomical reduction and there were no complications of wound infections. There were no complaint about hardware irritation. Conclusion: At fractures of distal fibula,preshaped LCP had a excellent stability although far cortex was not fixed with screw and bending of plate. And there are less complications of hardware irritation and wound problems. But, Some complement would be needed because there were no complete fitting between precontour of LCP and lateral cortical margin of distal fibula.