• 제목/요약/키워드: Anatomical landmarks

검색결과 95건 처리시간 0.022초

연조직 변형에 의한 해부학적 지표와 피부마커의 변위 상관성을 이용한 동작분석 오차 보정 방법의 적용 (Application of Compensation Method of Motion Analysis Error Using Displacement Dependency between Anatomical Landmarks and Skin Markers Due to Soft Tissue Artifact)

  • 류태범
    • 산업경영시스템학회지
    • /
    • 제35권4호
    • /
    • pp.24-32
    • /
    • 2012
  • Of many approaches to reduce motion analysis errors, the compensation method of anatomical landmarks estimates the position of anatomical landmarks during motion. The method models the position of anatomical landmarks with joint angle or skin marker displacement using the data of the so-called dynamic calibration in which anatomical landmark positions are calibrated in ad hoc motions. Then the anatomical landmark positions are calibrated in target motions using the model. This study applies the compensation methods with joint angle and skin marker displacement to three lower extremity motions (walking, sit-to-stand/stand-to-sit, and step up/down) in ten healthy males and compares their performance. To compare the performance of the methods, two sets of kinematic variables were calculated using different two marker clusters, and the difference was obtained. Results showed that the compensation method with skin marker displacement had less differences by 30~60% compared to without compensation. And, it had significantly less difference in some kinematic variables (7 of 18) by 25~40% compared to the compensation method with joint angle. This study supports that compensation with skin marker displacement reduced the motion analysis STA errors more reliably than with joint angle in lower extremity motion analysis.

The impact of reorienting cone-beam computed tomographic images in varied head positions on the coordinates of anatomical landmarks

  • Kim, Jae Hun;Jeong, Ho-Gul;Hwang, Jae Joon;Lee, Jung-Hee;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • 제46권2호
    • /
    • pp.133-139
    • /
    • 2016
  • Purpose: The aim of this study was to compare the coordinates of anatomical landmarks on cone-beam computed tomographic (CBCT) images in varied head positions before and after reorientation using image analysis software. Materials and Methods: CBCT images were taken in a normal position and four varied head positions using a dry skull marked with 3 points where gutta percha was fixed. In each of the five radiographic images, reference points were set, 20 anatomical landmarks were identified, and each set of coordinates was calculated. Coordinates in the images from the normally positioned head were compared with those in the images obtained from varied head positions using statistical methods. Post-reorientation coordinates calculated using a three-dimensional image analysis program were also compared to the reference coordinates. Results: In the original images, statistically significant differences were found between coordinates in the normal-position and varied-position images. However, post-reorientation, no statistically significant differences were found between coordinates in the normal-position and varied-position images. Conclusion: The changes in head position impacted the coordinates of the anatomical landmarks in three-dimensional images. However, reorientation using image analysis software allowed accurate superimposition onto the reference positions.

Setting the Stomach Transection Line Based on Anatomical Landmarks in Laparoscopic Distal Gastrectomy

  • Hosogi, Hisahiro;Kanaya, Seiichiro;Nomura, Hajime;Kinjo, Yousuke;Tsubono, Michihiko;Kii, Eiji
    • Journal of Gastric Cancer
    • /
    • 제15권1호
    • /
    • pp.53-57
    • /
    • 2015
  • Laparoscopic distal gastrectomy has become widespread as a treatment for early gastric cancer in eastern Asia, but a standard method for setting the stomach transection line has not been established. Here we report a novel method of setting this line based on anatomical landmarks. At the start of the operation, two anatomical landmarks along the greater curvature of the stomach were marked with ink: the proximal landmark at the avascular area between the last branch of the short gastric artery and the first branch of the left gastroepiploic artery, and the distal landmark at the point of communication between the right and left gastroepiploic arteries. Just before specimen retrieval, the stomach was transected from the center of these two landmarks toward the lesser curvature. Then, about two-third of the stomach was reproducibly resected, and gastroduodenostomy was successfully performed in 26 consecutive cases. This novel method could be used as a standard technique for setting the transection line in laparoscopic distal gastrectomy.

해부학적 계측점을 이용한 PC-기반3차원 치과수술 시스템 (3-Dimensional Dental Surgery System based on PC using anatomical landmarks)

  • 이경상;유선국;김형돈;배현수;김남현
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권2호
    • /
    • pp.139-148
    • /
    • 1999
  • 본 논문에서는 PC기반의 치과 수술 시스템을 설계하였다. 이 시스템은 수술 후의 3차원 영상을 예측할 수 있다. 따라서 환자는 수술 후에 CT를 다시 촬영하지 않아도 되며 방사선에 노출시킬 필용가 없다. 수술 전, 후의 두부(Cephalometry) X-ray 정보와 수술 전의 CT 데이터로부터 수술 후의 환자의 두개골을 예측한다. X-ray 필름과 수술 전의 CT를 해부학적 불변 계측점(anatomical landmarks) 방법을 기반으로 한 특이값 분해(SVD: singular value decomposition) 로 레지스트레이션(registration)을 하였으며, 이를 표면 재구성 영상화 시스템으로 설계하였다. 설계된 시스템의 유용성을 검증하기 위하여 건조 두개골 모델 실험과 실제 임상환자에 대한 임상실험을 시행하였으며 유의수준 0.05에서 유의차가 없는 것으로 나타났다.

  • PDF

Quantification of three-dimensional facial asymmetry for diagnosis and postoperative evaluation of orthognathic surgery

  • Cao, Hua-Lian;Kang, Moon-Ho;Lee, Jin-Yong;Park, Won-Jong;Choung, Han-Wool;Choung, Pill-Hoon
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.17.1-17.11
    • /
    • 2020
  • Background: To evaluate the facial asymmetry, three-dimensional computed tomography (3D-CT) has been used widely. This study proposed a method to quantify facial asymmetry based on 3D-CT. Methods: The normal standard group consisted of twenty-five male subjects who had a balanced face and normal occlusion. Five anatomical landmarks were selected as reference points and ten anatomical landmarks were selected as measurement points to evaluate facial asymmetry. The formula of facial asymmetry index was designed by using the distances between the landmarks. The index value on a specific landmark indicated zero when the landmarks were located on the three-dimensional symmetric position. As the asymmetry of landmarks increased, the value of facial asymmetry index increased. For ten anatomical landmarks, the mean value of facial asymmetry index on each landmark was obtained in the normal standard group. Facial asymmetry index was applied to the patients who had undergone orthognathic surgery. Preoperative facial asymmetry and postoperative improvement were evaluated. Results: The reference facial asymmetry index on each landmark in the normal standard group was from 1.77 to 3.38. A polygonal chart was drawn to visualize the degree of asymmetry. In three patients who had undergone orthognathic surgery, it was checked that the method of facial asymmetry index showed the preoperative facial asymmetry and the postoperative improvement well. Conclusions: The current new facial asymmetry index could efficiently quantify the degree of facial asymmetry from 3D-CT. This method could be used as an evaluation standard for facial asymmetry analysis.

The reliability of tablet computers in depicting maxillofacial radiographic landmarks

  • Tadinada, Aditya;Mahdian, Mina;Sheth, Sonam;Chandhoke, Taranpreet K;Gopalakrishna, Aadarsh;Potluri, Anitha;Yadav, Sumit
    • Imaging Science in Dentistry
    • /
    • 제45권3호
    • /
    • pp.175-180
    • /
    • 2015
  • Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

A numerical method for improving the reliability of knee translation measurement in skin marker-based motion analysis

  • Wang, Hongsheng;Zheng, Nigel
    • Advances in biomechanics and applications
    • /
    • 제1권4호
    • /
    • pp.269-277
    • /
    • 2014
  • In skin-marker based motion analysis, knee translation measurement is highly dependent on a pre-selected reference point (functional center) on each segment determined by the location of anatomical landmarks. However, the placement of skin markers on palpable anatomical landmarks (i.e., femoral epicondyles) has limited reproducibility. Thus, it produces large variances in knee translation measurement among different subjects, as well as across studies. In order improve the repeatability of knee translation measurement, in this study an optimization method was introduced, by which the femoral functional center was numerically determined. At that point the knee anteroposterior translation during the stance phase of walking was minimized. This new method was tested on 30 healthy subjects during walking in gait lab with motion capture system. Using this new method, the impact of skin marker position (at anatomical landmarks) on the knee translation measurement has been minimized. In addition, the ranges of anteroposterior knee translations during stance phase were significantly (p<0.001) smaller than those measured by conventional method which relies on a pre-selected functional center ($11.1{\pm}3.5mm$ vs. $19.9{\pm}5.5mm$). The results of anteroposterior translation using this new method were very close to a previously reported knee translation (12.4 mm) from dual fluoroscopic imaging technique. Moreover, this new method increased the reproducibility of knee translation measurement by 50%.

선 자세에서 엉치엉덩관절뼈 기준점 촉진의 검사자간, 검사자내 신뢰도 (Inter-Examiner and Intra-Examiner Reliability of Sacroiliac Anatomical Landmarks Palpation Test in Standing Posture)

  • 임범창;이정아;이충휘
    • 한국전문물리치료학회지
    • /
    • 제14권2호
    • /
    • pp.61-67
    • /
    • 2007
  • The purpose of this study was to examine inter- and intra-examiner reliability of the sacroiliac joint (SIJ) anatomical landmarks palpation. Two physical therapists and one doctor specializing in rehabilitation examined 22 asymptomatic subjects. They examined anterior superior iliac supine (ASIS), posterior superior iliac supine (PSIS) and iliac crest (IC). For the assessment of intra-examiner reliability, 3 examiners repeated the measurements 3 times over a 2-week interval. Kappa (Kg) yielded intra-examiner reliability that ranged between slight to fair for the ASIS (Kg=.06 to .26; mean Kg=.19), and slight for the PSIS(Kg=-.04 to .18; mean Kg=.07) and slight to fair for the IC (Kg=.06 to .32; mean Kg=.21). Inter-examiner reliability was slight (ASIS Kg=.13; PSIS Kg=.05; IC Kg=.14). These results suggest that the reliability of the assessing SIJ anatomical landmarks using palpation and observation as an indication of SIJ dysfunction still remains questionable. Before this test can be relied upon as an accurate indicator of SIJ dysfunction, it must undergo further research. This further research needs to examine not only reliability, but also validity, sensitivity and specificity.

  • PDF

Minimal Ablation of the Tibial Stump Using Bony Landmarks Improved Stability and Synovial Coverage Following Double-Bundle Anterior Cruciate Ligament Reconstruction

  • Kodama, Yuya;Furumatsu, Takayuki;Hino, Tomohito;Kamatsuki, Yusuke;Ozaki, Toshifumi
    • Knee surgery & related research
    • /
    • 제30권4호
    • /
    • pp.348-355
    • /
    • 2018
  • Purpose: To evaluate the clinical effects of using anatomical bony landmarks (Parsons' knob and the medial intercondylar ridge) and minimal ablation of the tibial footprint to improve knee anterior instability and synovial graft coverage after double-bundle anterior cruciate ligament reconstruction. Materials and Methods: We performed a retrospective comparison of outcomes between patients who underwent reconstruction with minimal ablation of the tibial footprint, using an anatomical tibial bony landmark technique, and those who underwent reconstruction with wide ablation of the tibial footprint. Differences between the two groups were evaluated using second-look arthroscopy, radiological assessment of the tunnel position, postoperative anterior knee joint laxity, and clinical outcomes. Results: Use of the anatomical reference and minimal ablation of the tibial footprint resulted in a more anterior positioning of the tibial tunnel, with greater synovial coverage of the graft postoperatively (p=0.01), and improved anterior stability of the knee on second-look arthroscopy. Both groups had comparable clinical outcomes. Conclusions: Use of anatomical tibial bony landmarks that resulted in a more anteromedial tibial tunnel position improved anterior knee laxity, and minimal ablation improved synovial coverage of the graft; however, it did not significantly improve subjective and functional short-term outcomes.

The Inaccuracy of Surface Landmarks for the Anterior Approach to the Cervical Spine in Southern Chinese Patients

  • Ko, Tin Sui;Tse, Michael Siu Hei;Wong, Kam Kwong;Wong, Wing Cheung
    • Asian Spine Journal
    • /
    • 제12권6호
    • /
    • pp.1123-1126
    • /
    • 2018
  • Study Design: Observational study. Purpose: To assess the correlational accuracy between the traditional anatomic landmarks of the neck and their corresponding vertebral levels in Southern Chinese patients. Overview of Literature: Recent studies have demonstrated discrepancies between traditional anatomic landmarks of the neck and their corresponding cervical vertebra. Methods: The center of the body of the hyoid bone, the upper limit of the lamina of the thyroid cartilage, and the lower limit of the cricoid cartilage were selected as representative surface landmarks for this investigation. The corresponding vertebral levels in 78 patients were assessed using computed tomography. Results: In both male and female patients, almost none of the anatomical landmarks demonstrated greater than 50% correlation with any vertebral level. The most commonly corresponding vertebra of the hyoid bone, the lamina of the thyroid cartilage, and the cricoid cartilage were the C4 (47.5%), C5 (35.9%), and C7 (42.3%), respectively, which were all different from the classic descriptions in textbooks. The vertebral levels corresponding with the thyroid and cricoid cartilage were significantly different between genders. Conclusions: The surface landmarks of the neck were not accurate enough to be used as the sole determinant of vertebral levels or incision sites. Intra-operative fluoroscopy is necessary to accurately locate each of the cervical vertebral levels.