Anatomical Reconstruction of the Medial Orbital Wall Fracture (안와내벽골절의 해부학적 복원술)

  • Choi, Woo Kyung;Kang, Dong Hee;Oh, Sang Ah
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • Purpose: In surgical treatment of the medial orbital wall fractures, restoring the original position of the orbital wall is difficult in some cases. Under such condition, the orbital wall is often reconstructed with synthetic material, without bony reduction, which is considered to be the conventional reconstruction. The purpose of this study is to compare the outcomes of anatomical reconstruction, which restores the bony wall to the anatomical position, from that of the conventional reduction in the isolated medial orbital wall fractures. Methods: Thirty patients, who underwent reconstruction surgery for the isolated medial orbital wall fractures from March 2007 to August 2011, were reviewed retrospectively. The surgical outcomes of two groups, the conventional reconstruction group (15 patients) and the anatomical reconstruction group (15 patients), were studied in 2 measurements, a one day before and 6 months after the surgery. The changes of orbital volume were calculated by the images from a computed tomography scan and enophthalmos was measured by a Hertel exophthalmometer. Results: The orbital volume ratio was decreased by an average of 1.05% in the conventional reconstruction group, while in the anatomical reconstruction group, the ratio decreased by 5.90% (p<0.05). The changes in the Hertel scale were 0.20 mm in the conventional reconstruction group, and 0.70 mm in the anatomical reconstruction group. However, the difference in the Hertel scale was statistically insignificant (p>0.05). Conclusion: In conclusion, the anatomical reconstruction technique of the isolated medial orbital wall fracture results in a better outcome than that of the conventional reconstruction, in terms of restoring of the original orbital volume and anatomic position. Thus, it can be considered as a useful method for the isolated medial orbital wall fractures.

Radiology Teaching Files on the Internet (인터넷상에 올려진 Radiology Teaching File에 관한 연구)

  • Lim Eun-Chung;Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.201-210
    • /
    • 1996
  • There is increasing attention about radiology teaching files on the Internet in the field of diagnostic radiology. The purpose of this study was to aid in the creation of new radiology teaching file by analysing the present radiology teaching file sites on the Internet with many aspects and evaluating images on those sites, using Macintosh IIci computer, 28.8kbps TelePort Fax/Modem, Netscape Navigator 2.0 software The results were as follow : 1. Analysis of radiology teaching file sites (l) Country distribution was the highest in USA(57.5%). (2) Average number of cases was 186 cases and radiology teaching file sites with search engine were 9 sites (22.5%). (3) At the method of case arrangement, anatomic area type and diagnosis type were found at the 10 sites(25%) each, question & answer type was found at the 9 sites(22.5%). (4) Radiology teaching file sites with oro-maxillofacial disorder were 9 sites(22.5%). (5) At the image format, GIF format was found at the 14 sites(35%). and ]pEG format found at the 14 sites(35%). (6) Created year was the highest in 1995(43.7%). (7) Continuing case upload was found at the 35 sites(87.5%). 2. Evaluation of images on the radiology teaching files (l) Average file size of GIF format (71 Kbyte) was greater than that of JPEG format(24 Kbyte). (p<0.001) (2) Image quality of GIF format was better than that of JPEG format. (p<0.001).

  • PDF

Reliability of two different presurgical preparation methods for implant dentistry based on panoramic radiography and cone-beam computed tomography in cadavers

  • Hu, Kyung-Seok;Choi, Da-Yae;Lee, Won-Jae;Kim, Hee-Jin;Jung, Ui-Won;Kim, Sung-Tae
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.2
    • /
    • pp.39-44
    • /
    • 2012
  • Purpose: Special care is necessary to avoid invading important anatomic structures during surgery when presurgical planning is made based on radiographs. However, none of these types of radiography represents a perfect modality. The purpose of this study was to determine the reliability of presurgical planning based on the use of two types of radiographic image (digital panoramic radiography [DPR] and cone-beam computed tomography [CBCT]) by beginner dentists to place implants, and to quantify differences in measurements between radiographic images and real specimens. Methods: Ten fresh cadavers without posterior teeth were used, and twelve practitioners who had no experience of implant surgery performed implant surgery after 10 hours of basic instruction using conventional surgical guide based on CBCT or DPR. Two types of measurement error were evaluated: 1) the presurgical measurement error, defined as that between the presurgical and postsurgical measurements in each modality of radiographic analysis, and 2) the measurement error between postsurgical radiography and the real specimen. Results: The mean presurgical measurement error was significantly smaller for CBCT than for DPR in the maxillary region, whereas it did not differ significantly between the two imaging modalities in the mandibular region. The mean measurement error between radiography and real specimens was significantly smaller for CBCT than for DPR in the maxillary region, but did not differ significantly in the mandibular region. Conclusions: Presurgical planning can be performed safely using DPR in the mandible; however, presurgical planning using CBCT is recommended in the maxilla when a structure in a buccolingual location needs to be evaluated because this imaging modality supplies buccolingual information that cannot be obtained from DPR.

Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Activity Curves (핵의학적 심혈관 촬영술에 의한 좌우 심단락의 진단 : 시간-방사능 곡선의 분석)

  • Kim, Ok-Hwa;Bahk, Yong-Whee;Kim, Chi-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.155-165
    • /
    • 1987
  • The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis-of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intra cardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs, intracardiac shunt could be differenciated from extracardiac shunts.

  • PDF

New trends of root canal disinfection and treatment strategies for infected root canal based upon evidence-based dentistry

  • Cho, Yong-Bum
    • Proceedings of the KACD Conference
    • /
    • 2003.11a
    • /
    • pp.608-608
    • /
    • 2003
  • The main objectives of root canal therapy are cleaning and shaping and then obturating the root canal system in 3 dimensions to prevent reinfection. Many instrumentation techniques and devices, supported by an irrigation system capable of removing pulp tissue remnants and dentin debris, have been proposed to shape root canals. But current regimens in chemomechanical debridement using instrumentation and irrigation with NaOCl are not predictably effective in root canal disinfection. These findings are not surprising because the root canal system is complex and contains numerous ramifications and anatomical irregularities. The microorganisms in root canals not only invade the anatomic irregularities of the root canal system but also are present in the dentinal tubules. Therefore further disinfection with an effective antimicrobial agent may be necessary and it well1mown that use of intracanal medication will lower bacterial count in infected root canals. Calcium hydroxide has a long history of use in endodontics, and more attention has been given to the use of calcium hydroxide as intracanal dressing for the treatment of infected pulp. However, when treatment is completed in one visit, no intracanal medications other than intracanal irrigants are used. Recently, a mixture of a tetracycline isomer, an acid, and a detergent(MTAD), has been introduced as a final rinse for disinfuction of the root canal system. It has been shown that MTAD is able to remove the smear layer with minimal erosive changes on the surface of dentin, and is effective against Enterococcus faecalis, a microorganism resistant to the action of other antimicrobial medications. In another study, the ability of MTAD was investigated to disinfect contaminated root canals with whole saliva and compared its efficacy to that of NaOCl Based on the results, it seems that MTAD is significantly more effective than 5.25% NaOCl in eradicating bacteria from infected root canals. In the cytotoxicity evaluation, MTAD is less cytotoxic than engenol, 3% $H20_2,\;Ca(OH)_2$ paste, 5.25% NaGCl, Peridex, and EDTA and more cytotoxic than 2.63%,1.31% and 0.66% NaOCl. Is it promising or transient?

  • PDF

Short-term clinical outcome of intentionally replanted posterior molars (의도적 재식술을 시행한 대구치의 단기간의 임상 평가)

  • Choi, Yong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.1
    • /
    • pp.12-18
    • /
    • 2011
  • Objectives: This retrospective study evaluated the therapeutic effects of the intentional replantation (IR) procedure performed on the maxillary and mandibular molars of 35 patients. Materials and Methods: For the subjects, IR was performed due to difficulties in anatomically accessing the lesions and/or close proximity to the thick cortical bone, inferior alveolar nerve, or maxillary sinus, which rendered the ordinary periradicular surgery impossible. The patients'progress was followed for a year and up to 2 years and 4 months. The success of the procedure was evaluated in terms of clinical and radiographic success (%). Results: The results revealed the following: (a) 1 case (3%) of failed tooth extraction during IR; (b) 2 cases (6%) of extraction due to periodontal diseases and inflammatory root resorption; (c) 3 cases (9%) of normally functioning teeth in the oral cavity with minor mobility and apical root resorption, and; (d) 29 cases (82%) of normally functioning teeth without obvious problems. Conclusions: IR was confirmed to be a reliably repeatable, predictable treatment option for those who cannot receive conventional periradicular surgery because of anatomic limitations or patient factors.

Reappraisal of Anatomic Outcome Scales of Coiled Intracranial Aneurysms in the Prediction of Recanalization

  • Lee, Jong Young;Kwon, Bae Ju;Cho, Young Dae;Kang, Hyun-Seung;Han, Moon Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.6
    • /
    • pp.342-348
    • /
    • 2013
  • Objective : Several scales are currently used to assess occlusion rates of coiled cerebral aneurysms. This study compared these scales as predictors of recanalization. Methods : Clinical data of 827 patients harboring 901 aneurysms treated by coiling were retrospectively reviewed. Occlusion rates were assessed using angiographic grading scale (AGS), two-dimensional percent occlusion (2DPO), and volumetric packing density (vPD). Every scale had 3 categories. Followed patients were dichotomized into either presence or absence of recanalization. Kaplan-Meier analysis was conducted, and Cox proportional hazards analysis was performed to identify surviving probabilities of recanalization. Lastly, the predictive accuracies of three different scales were measured via Harrell's C index. Results : The cumulative risk of recanalization was 7% at 12-month, 10% at 24-month, and 13% at 36-month of postembolization, and significantly higher for the second and third categories of every scale (p<0.001). Multivariate-adjusted hazard ratios (HRs) of the second and third categories as compared with the first category of AGS (HR : 3.95 and 4.15, p=0.004 and 0.001) and 2DPO (HR : 4.87 and 3.12, p<0.001 and 0.01) were similar. For vPD, there was no association between occlusion rates and recanalization. The validated and optimism-adjusted C-indices were 0.50 [confidence (CI) : -1.09-2.09], 0.47 (CI : -1.10-2.09) and 0.44 (CI : -1.10-2.08) for AGS, 2DPO, and vPD, respectively. Conclusion : Total occlusion should be reasonably tried in coiling to maximize the benefit of the treatment. AGS may be the best to predict recanalization, whereas vPD should not be used alone.

Effects of airway evaluation parameters on the laryngeal view grade in mandibular prognathism and retrognathism patients

  • Karm, Myong-Hwan;Chi, Seong In;Kim, Jimin;Kim, Hyun Jeong;Seo, Kwang-Suk;Bahk, Jae-Hyon;Park, Chang-Joo
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.16 no.3
    • /
    • pp.185-191
    • /
    • 2016
  • Background: Failure to maintain a patent airway can result in brain damage or death. In patients with mandibular prognathism or retrognathism, intubation is generally thought to be difficult. We determined the degree of difficulty of airway management in patients with mandibular deformity using anatomic criteria to define and grade difficulty of endotracheal intubation with direct laryngoscopy. Methods: Measurements were performed on 133 patients with prognathism and 33 with retrognathism scheduled for corrective esthetic surgery. A case study was performed on 89 patients with a normal mandible as the control group. In all patients, mouth opening distance (MOD), mandibular depth (MD), mandibular length (ML), mouth opening angle (MOA), neck extension angle (EXT), neck flexion angle (FLX), thyromental distance (TMD), inter-notch distance (IND), thyromental area (TMA), Mallampati grade, and Cormack and Lehane grade were measured. Results: Cormack and Lehane grade I was observed in 84.2%, grade II in 15.0%, and grade III in 0.8% of mandibular prognathism cases; among retrognathism cases, 45.4% were grade I, 27.3% grade II, and 27.3% grade III; among controls, 65.2% were grade I, 26.9% were grade II, and 7.9% were grade III. MOD, MOA, ML, TMD, and TMA were greater in the prognathism group than in the control and retrognathism groups (P < 0.05). The measurements of ML were shorter in retrognathism than in the control and prognathism groups (P < 0.05). Conclusions: Laryngoscopic intubation was easier in patients with prognathism than in those with normal mandibles. However, in retrognathism, the laryngeal view grade was poor and the ML was an important factor.

A fully deep learning model for the automatic identification of cephalometric landmarks

  • Kim, Young Hyun;Lee, Chena;Ha, Eun-Gyu;Choi, Yoon Jeong;Han, Sang-Sun
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.299-306
    • /
    • 2021
  • Purpose: This study aimed to propose a fully automatic landmark identification model based on a deep learning algorithm using real clinical data and to verify its accuracy considering inter-examiner variability. Materials and Methods: In total, 950 lateral cephalometric images from Yonsei Dental Hospital were used. Two calibrated examiners manually identified the 13 most important landmarks to set as references. The proposed deep learning model has a 2-step structure-a region of interest machine and a detection machine-each consisting of 8 convolution layers, 5 pooling layers, and 2 fully connected layers. The distance errors of detection between 2 examiners were used as a clinically acceptable range for performance evaluation. Results: The 13 landmarks were automatically detected using the proposed model. Inter-examiner agreement for all landmarks indicated excellent reliability based on the 95% confidence interval. The average clinically acceptable range for all 13 landmarks was 1.24 mm. The mean radial error between the reference values assigned by 1 expert and the proposed model was 1.84 mm, exhibiting a successful detection rate of 36.1%. The A-point, the incisal tip of the maxillary and mandibular incisors, and ANS showed lower mean radial error than the calibrated expert variability. Conclusion: This experiment demonstrated that the proposed deep learning model can perform fully automatic identification of cephalometric landmarks and achieve better results than examiners for some landmarks. It is meaningful to consider between-examiner variability for clinical applicability when evaluating the performance of deep learning methods in cephalometric landmark identification.

The occurrence of dental implant malpositioning and related factors: A cross-sectional cone-beam computed tomography survey

  • Safi, Yaser;Amid, Reza;Zadbin, Fariba;Ahsaie, Mitra Ghazizadeh;Mortazavi, Hamed
    • Imaging Science in Dentistry
    • /
    • v.51 no.3
    • /
    • pp.251-260
    • /
    • 2021
  • Purpose: Dental implants are widely used for the rehabilitation of edentulous sites. This study investigated the occurrence of dental implant malpositioning as shown on post-implantation cone-beam computed tomography (CBCT) and to identify related factors. Materials and Methods: Samples with at least 1 malpositioned dental implant were collected from a central radiology clinic in Tehran, Iran from January 2017 to January 2019. Variables such as demographic characteristics, length and diameter of implants, type of implant, sites of implant insertion, different types of implant malpositioning problems (cortical plate perforation, interference with anatomical structures), angulation of the implant, and the severity of malpositioning were assessed. In addition, the incidence of implant fracture and over-drilling was evaluated. Data were statistically analyzed using the chi-square test, 1-sample t-test, and Spearman correlation coefficients. Results: In total, 252 patients referred for implant postoperative CBCT evaluations were assessed. The cases of implant malpositioning included perforation of the buccal cortical plate (19.4%), perforation of the lingual cortical plate (14.3%), implant proximity to an adjacent implant (19.0%), implant proximity to an adjacent tooth (3.2%), interference with anatomical structures(maxillary sinus: 18.3%, mandibular canal: 11.1%, nasal cavity: 6.3%, mental foramen: 5.6%, and incisive canal: 0.4%). Implant fracture and over-drilling were found in 1.6% and 0.8% of cases, respectively. Severity was categorized as mild (9.5%), moderate (35.7%), severe (37.7%), and extreme (17.1%), and 52.4% of implants had inappropriate angulation. Conclusion: CBCT imaging is recommended for detecting dental implant malpositioning. The most common and severe type of malpositioning was buccal cortex perforation.