• 제목/요약/키워드: Analytical loss model

검색결과 179건 처리시간 0.029초

Analytical Modeling of TCP Dynamics in Infrastructure-Based IEEE 802.11 WLANs

  • Yu, Jeong-Gyun;Choi, Sung-Hyun;Qiao, Daji
    • Journal of Communications and Networks
    • /
    • 제11권5호
    • /
    • pp.518-528
    • /
    • 2009
  • IEEE 802.11 wireless local area network (WLAN) has become the prevailing solution for wireless Internet access while transport control protocol (TCP) is the dominant transport-layer protocol in the Internet. It is known that, in an infrastructure-based WLAN with multiple stations carrying long-lived TCP flows, the number of TCP stations that are actively contending to access the wireless channel remains very small. Hence, the aggregate TCP throughput is basically independent of the total number of TCP stations. This phenomenon is due to the closed-loop nature of TCP flow control and the bottleneck downlink (i.e., access point-to-station) transmissions in infrastructure-based WLANs. In this paper, we develop a comprehensive analytical model to study TCP dynamics in infrastructure-based 802.11 WLANs. We calculate the average number of active TCP stations and the aggregate TCP throughput using our model for given total number of TCP stations and the maximum TCP receive window size. We find out that the default minimum contention window sizes specified in the standards (i.e., 31 and 15 for 802.11b and 802.11a, respectively) are not optimal in terms of TCP throughput maximization. Via ns-2 simulation, we verify the correctness of our analytical model and study the effects of some of the simplifying assumptions employed in the model. Simulation results show that our model is reasonably accurate, particularly when the wireline delay is small and/or the packet loss rate is low.

Theoretical analysis of erosion degradation and safety assessment of submarine shield tunnel segment based on ion erosion

  • Xiaohan Zhou;Yangyang Yang;Zhongping Yang;Sijin Liu;Hao Wang;Weifeng Zhou
    • Geomechanics and Engineering
    • /
    • 제37권6호
    • /
    • pp.599-614
    • /
    • 2024
  • To evaluate the safety status of deteriorated segments in a submarine shield tunnel during its service life, a seepage model was established based on a cross-sea shield tunnel project. This model was used to study the migration patterns of erosive ions within the shield segments. Based on these laws, the degree of deterioration of the segments was determined. Using the derived analytical solution, the internal forces within the segments were calculated. Lastly, by applying the formula for calculating safety factors, the variation trends in the safety factors of segments with different degrees of deterioration were obtained. The findings demonstrate that corrosive seawater presents the evolution characteristics of continuous seepage from the outside to the inside of the tunnel. The nearby seepage field shows locally concentrated characteristics when there is leakage at the joint, which causes the seepage field's depth and scope to significantly increase. The chlorine ion content decreases gradually with the increase of the distance from the outer surface of the tunnel. The penetration of erosion ions in the segment is facilitated by the presence of water pressure. The ion content of the entire ring segment lining structure is related in the following order: vault < haunch < springing. The difference in the segment's rate of increase in chlorine ion content decreases as service time increases. Based on the analytical solution calculation, the segment's safety factor drops more when the joint leaks than when its intact, and the change rate between the two states exhibits a general downward trend. The safety factor shows a similar change rule at different water depths and continuously decreases at the same segment position as the water depth increases. The three phases of "sudden drop-rise-stability" are represented by a "spoon-shaped" change rule on the safety factor's change curve. The issue of the poor applicability of indicators in earlier studies is resolved by the analytical solution, which only requires determining the loss degree of the segment lining's effective bearing thickness to calculate the safety factor of any cross-section of the shield tunnel. The analytical solution's computation results, however, have some safety margins and are cautious. The process of establishing the evaluation model indicates that the secondary lining made of molded concrete can also have its safety status assessed using the analytical solution. It is very important for the safe operation of the tunnel and the safety of people's property and has a wide range of applications.

소음기의 투과손실 및 배압특성에 관한 연구 (A Study on Muffler′s Transmission Loss and Backpressure Property)

  • 정경훈;황원걸;이유엽;김기세
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.676-681
    • /
    • 2001
  • We usually divide the noise of exhaust system into pulsation noise and flow noise. Pulsation noise is the shock wave to occur when the burning gas of low pressure emits and include harmonic having basic frequency as the exhaust cycle of engine. Flow noise is the noise that is produced when gas flow emits into the atmosphere through the pipe and has the character of frequency like pink noise which has the high level of high frequency component. A muffler is divided into reflective type and absorptive type. We usually use the muffler compounding the property of them. In this study, it is the case of transfer matrix method that a muffler is compounded to analyze the elements of each section according to sound wave's proceed direction. But we use simple model. So, we use finite element method that takes short time to analyze. Acoustic analysis gives us transfer matrix to use FEA of SYSNOISE and we use STAR-CD for fluid analysis. We made database that is based on analytical results about the muffler of expansion type, extended type, offset type, reverse type, and perforated type and developed the muffler design system to perform work efficiently.

  • PDF

고속 전철용 가선-팬터그래프 시스템의 모델링 및 접촉력 해석 (A Modeling and Contact Force Analysis of the Catenary-pantograph System for a High-speed Rail Vehicle)

  • 김진우;박인기;장진희;왕영용;한창수
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.474-483
    • /
    • 2003
  • In this study, the dynamic characteristics of a catenary system and pantograph supplying electrical power to high-speed trains are investigated. One of the most important issues accompanied by increasing the speed of high-speed rail is stabilization of current collection. To stabilize current collection, it is necessary the contact force between the catenary and the pantograph to be kept continuous without loss of contact. The analytical model of a catenary and a pantograph is constructed to simulate the behavior of an actual system. The analysis of the catenary based on the Finite Element Method (FEM) is performed to develop a catenary model suitable for high speed operation. The reliability of the models is verified by the comparison of the excitation test with Fast Fourier Transform (FFT) data of the actual system. The static deflection of the catenary, stiffness variation in contact lines, dynamic response of the catenary undergoing constant moving load, contact force, and each state of the pantograph model were calculated. It is confirmed that a catenary and pantograph model are necessary for studying the dynamic behavior of the pantograph system.

저 누드센 영역에서 구형 포집체상의 에어로졸 물질 전달 (Mass Transfer of Aerosol onto Spherical Collector at Low Knudsen Number)

  • 정창훈
    • 한국대기환경학회지
    • /
    • 제21권5호
    • /
    • pp.547-555
    • /
    • 2005
  • In this study, an analytical expression for aerosol mass transfer at spherical collector in the low Knudsen number region was obtained. Happel's zero shear stress cell model was extended in the low Knudsen number region and the result was compared with numerical solution results. The zero vorticity model based on the Kuwabara's cell model was also extended in the low Knudsen number region and compared with Happel's results. The results showed that both analytic and numerical solution agree very well with each other in low Knudsen number region. Happel's zero shear stress model also agrees with Kuwabara's zero vorticity model without significant loss of accuracy. The obtained solution converges to the original solution of Lee et al. (1999) when Knudsen number approaches to zero. Subsequently, this study derived most general type of analytic solution for aerosol mass transfer of spherical collector including the finite Knudsen number region.

점탄성 제진재를 이용한 비구속형 제진강판의 최적설계에 관한 연구 (A Study on Optimum Design of an Unconstrained Damping Steel Plate by Using Viscoelastic Damping Material)

  • 유영훈;양보석
    • 소음진동
    • /
    • 제5권4호
    • /
    • pp.493-501
    • /
    • 1995
  • Optimum design of a viscoelastic damping layer which is unconstrainedly cohered on a steel plate is discussed from the viewpoint of the modal loss factor. Themodal loss factor is analyzed by using the energy method to the base steel plate and cohered damping layer. Optimum distributions of the viscoelastic damping layer for modes are obtained by sequentially changing the position of a piece of damping layer to another position which contributes to maximizing the modal loss factors. Analytical procedure performed by using this method simulated for 3 fundamental modes of an edge-fixed plate. Simulated results indicate that the modal loss factor ratios can be increase by as much as 210%, or more, by optimizing the thickness distribution of the damping layer to two times of the initial condition which is entirely covered. Optimum configurations for the modes are revealed by positions where added damping treatments become most effective. The calculated results by this method are validated by comparison with the experimental results and the calculated results obtained by the Ross-Ungar-Kerwin's model in the case of the layer is uniformly treated over the steel plate.

  • PDF

AN EVALUATION OF THE APERIODIC AND FLUCTUATING INSTABILITIES FOR THE PASSIVE RESIDUAL HEAT REMOVAL SYSTEM OF AN INTEGRAL REACTOR

  • Kang Han-Ok;Lee Yong-Ho;Yoon Ju-Hyeon
    • Nuclear Engineering and Technology
    • /
    • 제38권4호
    • /
    • pp.343-352
    • /
    • 2006
  • Convenient analytical tools for evaluation of the aperiodic and the fluctuating instabilities of the passive residual heat removal system (PRHRS) of an integral reactor are developed and results are discussed from the viewpoint of the system design. First, a static model for the aperiodic instability using the system hydraulic loss relation and the downcomer feedwater heating equations is developed. The calculated hydraulic relation between the pressure drop and the feedwater flow rate shows that several static states can exist with various numbers of water-mode feedwater module pipes. It is shown that the most probable state can exist by basic physical reasoning, that there is no flow rate through the steam-mode feedwater module pipes. Second, a dynamic model for the fluctuating instability due to steam generation retardation in the steam generator and the dynamic interaction of two compressible volumes, that is, the steam volume of the main steam pipe lines and the gas volume of the compensating tank is formulated and the D-decomposition method is applied after linearization of the governing equations. The results show that the PRHRS becomes stabilized with a smaller volume compensating tank, a larger volume steam space and higher hydraulic resistance of the path $a_{ct}$. Increasing the operating steam pressure has a stabilizing effect. The analytical model and the results obtained from this study will be utilized for PRHRS performance improvement.

원형 파일 방파제에 의한 반사율과 투과율 (Reflection and Transmission Coefficients by a Circular Pile Breakwater)

  • 조일형;고혁준
    • 한국해안해양공학회지
    • /
    • 제19권1호
    • /
    • pp.38-44
    • /
    • 2007
  • Bennet 등(1992)이 제안한 수학적 모델을 사용하여 원형 파일 방파제에 의한 반사율과 투과율을 살펴보았다. 파가 파일 방파제를 통과하면서 갑작스런 단면형상의 변화로 박리현상이 발생하며 이로 인하여 파 에너지의 일부분이 소멸된다. 따라서 수학적 모델의 신뢰성을 높이기 위해서는 에너지 손실계수를 정확히 산정하는 것이 중요하다. 본 연구에서는 FLUENT 상용코드를 사용하여 2차원 난류유동을 해석하고 파일 방파제 전후의 압력차로부터 에너지 손실계수를 구하였다. 에너지 손실계수는 공극률의 함수이며, 둘 사이의 관계식을 제안하였다. 손실계수 산정식의 타당성을 검증하기 위하여 수리모형실험결과와 비교하였다. 4가지 공극률에 대하여 반사율과 투과율을 비교한 결과 해석결과와 모형실험결과는 잘 일치하고 있음을 확인하였다.

고온초전도 전력케이블 단말 저온조의 개념 설계 (Conceptual Design of Terminal Cryostat for HTS Power Cable)

  • 김승현;김동락;조승연
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2002년도 학술대회 논문집
    • /
    • pp.37-39
    • /
    • 2002
  • The model of terminal cryostat for HTS power cable is conceptually designed. In this paper we defined that heat loads of the terminal cryostat was only cooled by the liquid nitrogen without cooling gas. Total heat loss calculated by analytical and numerical methods are 46.4W at 0A and 69W at 1260A for the 3-Phase HTS power cable system of 50MW, 22.9kV.

  • PDF

고주파 전기저항 용접법에서 적정 용접조건의 수학적 모델 (Mathmetical Modeling of Welding Conditions for High Frequency Electric Resistance Welding Process)

  • 강덕일;장영섭;오주섭;공원일;김용석
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 1996년도 특별강연 및 춘계학술발표 개요집
    • /
    • pp.13-14
    • /
    • 1996
  • High Frequency Electric Resistance Welding process has been widely used in manufacturing welded steel pipes because of its high welding speed and quality. This process utilizes the skin effect as well as the proximity effect of the high frequency current in heating the skelp edge. In this study, an analytical solution of the edge temperature was obtained based on several assumptions. The assumptions includes the expontial decay of weldingcurrent from the surface and neglect of the heat loss in the welding direction. This calculation shows a good agreement with the observations made from the high speed camera. Using tile analytical model, tile heat required as a function of the welding speed and the skelp thickness was determined. These results were compared with the experimental results obtained.

  • PDF