• 제목/요약/키워드: Analytical Quality Control

검색결과 337건 처리시간 0.023초

조건부 차이조사의 관리한계 결정: 다구찌 품질손실 개념의 응용 (Determination of Control Limits of Conditional Variance Investigation: Application of Taguchi's Quality Loss Concept)

  • 배후석;임채관
    • 품질경영학회지
    • /
    • 제49권4호
    • /
    • pp.467-482
    • /
    • 2021
  • Purpose: The main theme of this study is to determine the optimal control limit of conditional variance investigation by mathematical approach. According to the determination approach of control limit presented in this study, it is possible with only one parameter to calculate the control limit necessary for budgeting control system or standard costing system, in which the limit could not be set in advance, that's why it has the advantage of high practical application. Methods: This study followed the analytical methodology in terms of the decision model of information economics, Bayesian probability theory and Taguchi's quality loss function concept. Results: The function suggested by this study is as follows; ${\delta}{\leq}\frac{3}{2}(k+1)+\frac{2}{\frac{3}{2}(k+1)+\sqrt{\{\frac{3}{2}(k+1)\}^2}+4$ Conclusion: The results of this study will be able to contribute not only in practice of variance investigation requiring in the standard costing and budgeting system, but also in all fields dealing with variance investigation differences, for example, intangible services quality control that are difficult to specify tolerances (control limit) unlike tangible product, and internal information system audits where materiality standards cannot be specified unlike external accounting audits.

An Experimental Estimation of Two Detection Limit Models

  • Ma Chang-Jin;Tohno Susumu;Kasahara Mikio;Kang Gong-Unn
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제20권E1호
    • /
    • pp.29-33
    • /
    • 2004
  • In environmental studies, decisions are often made on the analytical data indicating certain contaminants as being 'detected' or 'non-detectible.' Since detection limits are analytical method specific, one has to first review the concepts and definitions associated with analytical method systems and specifications. In this study, the experimental analytical values for a series of low level standards (for an ionic species) were used as an example to estimate two different method detection limits (MDL). The scores of EPA's MDL and Pallesen's MDL determined by real analytical scores are 0.0575 and 0.0561 mg/L, respectively for our nitrate data. These scores determined by two different MDL models are roughly similar, while there are apparent differences between two methods with respect to statistical and systematical procedure. However, determination of MDL for one's laboratory provides some practical applications which helps to assure one's regulating authorities that one's measured scores are accurate.

모세관 전기영동 분석법의 복합약물제제의 품질관리 분석에 응용을 위한 연구 (Application of Capillary Electrophoresis for Quality Control Analysis of Complex Medicine)

  • 허유정;이공주
    • 약학회지
    • /
    • 제41권5호
    • /
    • pp.539-546
    • /
    • 1997
  • Capillary electrophoresis (CE) is perceived as an attractive tool for the analysis of pharmaceuticals and biological materials because of their high separation efficiency, easy separation and low running cost. New concept of micellar electrokinetic capillary chromatography (MECC) expanded the application of CE to the separation of neutral molecules. Validation of CE as an analytical technique for quality control of pharmaceuticals should be confirmed by quantitative analysis and the peak confirmation. In this study, the quantitative analyses of various types of neutral, acidic and basic components (acetaminophen, caffeine, ascorbic acid, riboflavin, thiamine, chlorpheniramine, phenylpropanolamine, dl-methylephedrine and dextromethorphan) in complex cold medicines have been accomplished using CE. Combined methods of MECC using SDS and capillary zone electrophoresis lowering the pH of running buffer were adopted to determine the ingredients in capsule type or liquid formula complex medicines without particular sample pretreatment. The results indicate that CE is a promising technique for quality control analysis of pharmaceuticals as a validation method.

  • PDF

흑연료 원자흡수 분광법에 의한 혈중의 납, 카드뮴 정량을 위한 외부정도관리 시료제조 및 분석 (Preparation and analysis of lyophilized whole blood as external quality control materials for Pb and Cd determination by graphite furnace atomic absorption spectrometry)

  • 이공주;임흥빈
    • 분석과학
    • /
    • 제8권3호
    • /
    • pp.273-279
    • /
    • 1995
  • 납과 카드뮴을 포함하는 여러 가지 농도의 동결건조된 혈액이 외부정도관리 시료로서 제조되었다. 이 시료들은 흑연료 원자흡수분광법(GFAAS)을 이용하여 성능이 파악되었다. 매트릭스 개선제로서 0.1% ammonium dihydrogen phosphate와 0.1% Triton X-100을 사용하여 섭씨 600 내지 650도의 회화온도에서 혈액에 있는 납과 카드뮴의 정량 분석을 위한 GFAAS의 최적 분석조건이 얻어졌다. 제조된 혈액의 균질도와 안정도는 최적화된 분석조건에서 연구되었다.

  • PDF

Experiment design and human reliability in software quality control system

  • Park, Peom
    • 품질경영학회지
    • /
    • 제20권2호
    • /
    • pp.94-108
    • /
    • 1992
  • This study involves an experiment for the cognitive experiment design and the human reliability in software engineering. Its overall objectives are to analyze common-cause human domain error and reliability in human-software interaction. A laboratory study was performed to analyze software engineers' task behavior in software production and to identify software design factors contributing to the effects in common cause failure redundancy. Common-cause model and its function were developed, then the main experiment using programming experts was conducted in order to define a new cognitive paradigm, in the aspects of identification, pattern recognition, and behavior domain for human reliability and quality control in software development. The results and analytical procedures developed in this research can be applied to reliability improvement and cost reduction in software development for many applications. Results are also expected to provide guidelines for software engineering quality control and for more effective design of human-software interface system.

  • PDF

고형물 석면분석에 대한 국내 정도관리 프로그램에서 나타난 분석 오류의 특성 (Characteristics of Analytical Errors Shown in the Korean Quality Control Program on Bulk Asbestos Analyses)

  • 권지운;정은교;이인섭;강성규;김현욱
    • 한국산업보건학회지
    • /
    • 제21권4호
    • /
    • pp.222-226
    • /
    • 2011
  • This study was conducted to identify the characteristics of analytical errors shown in the Korean quality control program on bulk asbestos analyses using polarized light microscopy (PLM). 179 participating laboratories were required to analyze 4 samples respectively and asked to classify each test sample as asbestos-containing (positive) or non-asbestos-containing (negative). For positive samples, participants were also asked to identify the type and semiquantitate the contents of asbestos present. The test results showed 21 (4%) false negative errors among 562 samples, 9 (6%) false positive errors among 154 samples and 53 (9%) asbestos identification errors among 562 samples. Most of false negative and positive errors were observed in a few types of samples. Higher frequencies of asbestos identification errors were shown in samples containing two or more types of asbestos and samples containing anthophyllite, tremolite or actinolite asbestos. For semiquantitative analyses, the ratios of mean to nominal weight contents were 2.1 for chrysotile and 2.9 for amphiboles. A tendency of over-estimation was observed in semiquantitative analyses using the visual estimation technique and higher in case of analyzing samples containing amphiboles than chrysotile. Coefficients of variation (CVs) of semiquantitative analytical results were 0.44~0.83 and 0.5~1.14 for samples containing chrysotile and amphibole asbestos, respectively.

작업환경측정기관의 정도관리를 통한 분석능력이 미흡한 기관들의 분석오차 유발요인에 관한 고찰 (A Study on the Analytical Errors of Non-proficient Laboratories Participated in Quality Control Program)

  • 박동욱;신용철;박승현;이나루;오세민;윤충식;백남원
    • 한국산업보건학회지
    • /
    • 제4권1호
    • /
    • pp.96-102
    • /
    • 1994
  • Factors affecting non-proficient analytical ability were compared and evaluated by rating of laboratories and round. Analyst Indices between proficient and non-proficient participants were different. Coefficients of determination($R^2$) for standard of toluene, xylene and trichloroethylene of the 4th round between some proficient and non-proficient participants were significantly different(p<0.05). But, there was no difference in the 5th round. Average desorption efficiency of non-proficient participants was 88%-98%, which was lower than 96%-100% of some randomly selected proficient participants. Also non-proficient participants have a large variance of desorption efficiency, 11.79-19.69%. In the 5th round, desorption efficiency of metyl iso-butyl ketone(MIBK) reported by all participants was lower than 90% tested by NIOSH and especially low compared to other analytes. Participants evaluated to be non-proficient in the metal part have 85%-100.84% of average recovery, which was larger variance than 98% of some proficient participants. Although it is difficult to find quantitatively factors causing non-proficiency in analytical ability, pretreatement techniques and experience of analyst seems to be more important factors to produce accurate analytical result.

  • PDF

중성자방사화분석법을 이용한 성인여성 혈청중의 무기 원소 분석 (Determination of Inorganic Elements in Women Blood Serum using Instrumental Neutron Activation Analysis)

  • 문종화;정용삼;이옥희
    • 분석과학
    • /
    • 제15권6호
    • /
    • pp.509-513
    • /
    • 2002
  • 본 연구는 우리나라 성인여성의 혈청 내 미량 무기 원소의 농도를 조사하기 위해 중성자 방사화 분석법을 적용하였다. 혈청시료중의 나트륨과 염소의 높은 농도가 분석에 제헌을 주었으며 이들의 간섭을 최소화시킨 분석조건에서 Br, Ca, Cl, Co, Cr, Cs, Fe, K, Na, Rb, Se, Zn 와 같은 12종 원소의 분석이 가능하였다. 63명의 성인여성으로부터 채취한 혈청시료를 분석시료를 분석하여 각 원소의 농도수준과 범위 등을 결정하였으며 미국표준연구소의 표준물질들을 혈청시료와 동시에 분석하여 분석품질관리에 사용하였다. 혈청시료중의 무기질원소들의 평균값은 Na 과 Cl은 약 3000 mg/L, Ca은 약 100 mg/L, K은 200 mg/L, Br, Se 및 Zn은 각각 6.0, 0.1, 1.0 mg/L 등의 농도수준을 보였으며 지금까지 보고된 값과 비교한 결과 큰 차이를 보이지 않았다.

용접흄내 중금속분석시 전처리 방법별 효율비교 (A Comparison of Efficiency of Two Pretreatment Methods for Extracting Heavy Metals from Welding Fume Samples)

  • 손두영;김현욱
    • 한국산업보건학회지
    • /
    • 제9권2호
    • /
    • pp.135-144
    • /
    • 1999
  • The purposes of this study were to survey types of pretreatment methods adopted by industrial hygiene laboratories in Korea for extracting heavy metals in welding fume samples and to compare performances of two pretreatment methods, the acid extraction and the microwave digestion, in extracting heavy metals contained in the real workplace samples from various welding jobs including arc, argon, and carbon dioxide. A total of 25 analytical chemists in the industrial hygiene laboratories participating the quality control program directed by the Korea Industrial Safety Corporation were interviewed by telephone. For the purpose of comparing performance of extracting heavy metals from real workplace samples, a total of 53 welders from 21 workplaces located in Anyang, Uiwang, and Kunpo areas were sampled from the period of March 22, 1999 to April 20, 1999. It was found that the most frequently adopted method for samples from the quality control program was the acid extraction method(40%) followed by the NIOSH 7300 method(36%). The NIOSH method, however, was the dominant method(36%) for samples from workplace followed by the acid extraction method(28%). In this study, two extraction methods, the acid extraction and the microwave digestion, were compared in terms of recovery rate, accuracy, and precision for both manganese and chromium. Both methods produced comparable results for the samples prepared for the quality control program. In contrast, concentrations of two heavy metals determined from real workplace samples pretreated with the microwave digestion method were statis tically significantly higher, manganese(166%) and chromium (200%), than those of utilizing the acid extraction method. These findings were consistent regardless of types of welding techniques used. The results of this study clearly show the importance of verifying the analytical performances of extraction methods for heavy metals not only for the samples from the quality control program but also from the real world samples collected from welding jobs.

  • PDF

CHARACTERISTICS OF A NEW PNEUMATIC TRANSFER SYSTEM FOR A NEUTRON ACTIVATION ANALYSIS AT THE HANARO RESEARCH REACTOR

  • Chung, Yong-Sam;Kim, Sun-Ha;Moon, Jong-Hwa;Baek, Sung-Yeol;Kim, Hark-Rho;Kim, Young-Jin
    • Nuclear Engineering and Technology
    • /
    • 제41권6호
    • /
    • pp.813-820
    • /
    • 2009
  • A rapid pneumatic transfer system (PTS) for an instrumental neutron activation analysis (INAA) is developed as an automatic irradiation facility involving the measurement of a short half-life nuclide and a delayed neutron counting system. Three new PTS designs with improved functions were constructed at the HANARO research reactor in 2006. The new system is composed of a manual system and an automatic system for both an INAA and a delayed neutron activation analysis (DNAA). The design and basic conception of a modified PTS are described, and the functions of system operation and control, radiation protection and emissions of radioactive gas are improved. In addition, a form of capsule transportation of these systems is tested. The experimental results pertaining to the irradiation characteristics with variation of the neutron flux and the temperature of the irradiation position with the irradiation time are presented, as is an analysis of the reference material for analytical quality control and uncertainty assessments.