• Title/Summary/Keyword: Analysis system

Search Result 69,754, Processing Time 0.104 seconds

Preparation of Na-X and Na-A Zeolites from Coal Fly Ash in a Thermoelectric Power Plant and Comparison of the Adsorption Characteristics for Cu(II) with a Commercial Zeolite (화력발전소 석탄비산재를 이용한 Na-X와 Na-A 제올라이트 제조 및 상업용 제올라이트와의 Cu(II) 흡착 특성 비교)

  • Choi, Yu-Lim;Angaru, Ganesh Kumar Reddy;Kim, Dong-Su;Ahn, Hye-Young;Kim, Dae-Ho;Choi, Chi-Dong;Reddy, Kodoru Janardhan;Yang, Jae-Kyu;Chang, Yoon-Young
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.749-756
    • /
    • 2019
  • Na-X and Na-A zeolites that give high adsorption capacity for heavy metals in an aqueous system were synthesized from the coal fly ash obtained from a thermoelectric power plant using a fusion method. The characteristics and Cu(II) adsorption capacity of the synthetic zeolites were also compared to those of using a commercial zeolite. For the selection of optimum conditions of zeolite synthesis, the effects of major parameters in the fusion method such as a dosage ratio of NaOH, aging time, hydrothermal reaction time, and also the dosage ratio of NaAlO2 (Na-A) on the characteristics and Cu(II) adsorption capacity of the synthetic zeolites were studied. For the analysis of characteristics of the synthetic zeolites, X-ray diffraction (XRD), cation exchange capacity (CEC), Brunaue-Emmett-Teller (BET) and scanning electron microscopy (SEM) were used. The optimum conditions for the synthesis of zeolites with a high adsorption capacity for cationic heavy metals including Cu(II) were the aging time of 6 h, hydrothermal reaction time of 6 h and NaOH and NaAlO2 dosage ratio of 1.5 and 0.5 (Na-A), respectively. According to the Langmuir isotherm test, maximum Cu(II) adsorption capacities of the synthetic and commercial Na-X and Na-A zeolites were found to be 90.1, 105.26, 102.05, and 109.89 mg/g, respectively. This indicates that the adsorption capacity of synthetic zeolites was comparable to commercial ones. The results of this study also suggest that the coal fly ash can be potentially used as a raw material for the zeolite synthesis.

Assessment of Regional-Based Nitrogen Loading and Recycling Capacity of Livestock Manure (지역별 가축분뇨의 질소부하 및 자원화 용량 평가)

  • Ryoo, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.18 no.3
    • /
    • pp.235-246
    • /
    • 2012
  • Reusing livestock manure have various advantages in securing soil organic resources. In this study, the N-loading and recycling capacity assessment of animal manure was analyzed by comparing between the cultivated areas of crops and the amount of manure units that are generated from livestock manure. From this assessment, the possibility of recycling resources of livestock manure was evaluated. The amount generated of livestock manure in Gyeonggi-do were evaluated by applying the manure units to the number of livestock manure. The analysis of manure unit per ha shows that the N loading by MU is quite different by region. When it comes to nitrogen loading, the MU per ha of cultivated land in excess of the N-amount was the highest in the Gyeonggi-do province with 2.70 MU/ha, which is higher than the appropriate level. The Chungcheongnam-do province came next with 2.31 MU. So the recycling capacity assessment was carried out mainly based on areas of forage crops, rice that can be provided by recycling livestock manure. The recycling capacity ware highest in Jeollanam-do and Jeollabuk-do. In order to properly apply the livestock manure into organic resources, the seasonal situation that effects the nitrogen demands of crops along with the regional effects crop cultivation should be seriously analyzed. In addition, a system that can effectively produce and manage fertilizer should be established.

The Weight Analysis of Evaluation Indicators for Assessing Livestock Manure Treatment System and its Technology by AHP (AHP를 활용한 가축분뇨 처리시설 및 관련기술 평가지표 가중치 설정)

  • Kim, J.H.;Cho, S.H.;Kwag, J.H.;Choi, D.Y.;Jeong, K.H.;Cheon, D.W.;Lee, S.H.;Kim, J.H.;So, K.H.;Park, C.H.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.sup
    • /
    • pp.51-60
    • /
    • 2011
  • The objective of this study was to suggest strategies for improving "Livestock Manure Treatment Systems and Related Technologies Assessment Program". Analytic Hierarchy Process (AHP) was used to evaluate reasonableness of applied weight value for assessment and improve program management strategies. Results of mail survey collected from animal manure treatment technology specialists of 30 companies nationwide were used for AHP. Company's ability, technological prowess, facility's convenience, economic feasibility are four important aspects of assessment program evaluation using AHP. More than 70% of the respondents said they were overall satisfied with the objectivity of assessment program regarding above four evaluation aspects. However, only 36% of them answered that they were very satisfied with the objectivity of assessment program in terms of economic feasibility. The evaluation results revealed that the assessment program needs to be made up for the weak points regarding economic feasibility. The AHP weight calculation results showed that the current assessment program overestimates the technological prowess, especially livestock manure treatment efficiency. It suggests that the weight value of current assessment program in terms of technological prowess needs to be determined carefully. The current assessment program combined with AHP weight value determination approach will be very useful to improve objectivity and reliability of assessment.

A Study of material analysis and its experimentation of metamorphosis and its utilities in Copper Alloy plates for contemporary metal craft (현대금속공예용 동합금판의 재료분석과 형질변환 실험 및 응용에 관한 연구)

  • Lim, Ock-Soo
    • Archives of design research
    • /
    • v.17 no.4
    • /
    • pp.241-250
    • /
    • 2004
  • In this research, the copper alloy plates C2200, C5210, C7701, C8113 were selected to make datum and to identify further usage of metal craft experimentation. For its experimentation, the general welding and TIG welding methods were researched; for 2nd experimentation, the Reticulation and Electroforming skill's differences in color and temperature were researched. With these methods 3 different kinds of works are introduced for sample studies. For this research, Dr. Lee, Dong-Woo who works in Poongsan Metal Co, supported 4 kinds of copper alloy metals. Which are Commercial bronze (Cu-Zn), Deoxidiged Copper(Cu-Sn-P), Nickel Silver (Cu-Ni-Zn), and White Bronze (Cu-Ni); they were applied partly and wholly by the method of Laminatin, Reticulation, Fusing, and Electroforming skills. In case of C2200, the brass, the A. C. TIG welding method is better under 2mm slight plate; the D.C. TIG welding is better upper 2mm plate; and 250~300$^{\circ}C$ is recommended for remain heat treatment. In case of C5210, not having Hydrogen in high temperature return period, doesn't need Oxygen in high temperature and hardening in comparative high temperature neither, it is good for welding. It contains Sn 2-9% ad P 0.03-0.4% generally; and in accordance with the growth rate of Sn contain amount, the harden temperature boundary become broad. In case of cold moment after welding, they are recommended that higher speed TIG welding, smaller melting site and less than 200$^{\circ}C$ for pre-heating temperature. In case of C7701, the 10-20% Ni, 15-30% Zn are widely used.. If it is upper 30% Zn, it become (${\alpha}+{\beta}$) system and adhesive power rate become lower, and the productivity become lower in low temperature but the productivity become higher in high temperature. Nickel Silver's resistance of electricity is well; and the heatproof and incorrodibility is good, too. Lastly, in case of C8113, good at persistence in salty and grind; high in strength of high temperature. In case of white brass, contain 10-30% Nickel and hardened in high temperature and become single phrase. For these reason, the crystallization particles easily become large, if the resistance become higher small amount of Pb, P, S separation rate become higher.

  • PDF

Verification of Non-Uniform Dose Distribution in Field-In-Field Technique for Breast Tangential Irradiation (유방암 절선조사 시 종속조사면 병합방법의 불균등한 선량분포 확인)

  • Park, Byung-Moon;Bae, Yong-Ki;Kang, Min-Young;Bang, Dong-Wan;Kim, Yon-Lae;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.277-282
    • /
    • 2010
  • The study is to verify non-uniform dose distribution in Field-In-Field (FIF) technique using two-dimensional ionization chamber (MatriXX, Wellhofer Dosimetrie, Germany) for breast tangential irradiation. The MatriXX and an inverse planning system (Eclipse, ver 6.5, Varian, Palo Alto, USA) were used. Hybrid plans were made from the original twenty patients plans. To verify the non-uniform dose distribution in FIF technique, each portal prescribed doses (90 cGy) was delivered to the MatriXX. The measured doses on the MatriXX were compared to the planned doses. The quantitative analyses were done with a commercial analyzing tool (OmniPro IMRT, ver. 1.4, Wellhofer Dosimetrie, Germany). The delivered doses at the normalization points were different to average 1.6% between the calculated and the measured. In analysis of line profiles, there were some differences of 1.3-5.5% (Avg: 2.4%), 0.9-3.9% (Avg: 2.5%) in longitudinal and transverse planes respectively. For the gamma index (criteria: 3 mm, 3%) analyses, there were shown that 90.23-99.69% (avg: 95.11%, std: 2.81) for acceptable range ($\gamma$-index $\geq$ 1) through the twenty patients cases. In conclusion, through our study, we have confirmed the availability of the FIF technique by comparing the calculated with the measured using MatriXX. In the future, various clinical applications of the FIF techniques would be good trials for better treatment results.

Analysis of Dose Reduction Rate with Dose Modulation Technic Depending on BMI (PET/CT검사에서 Dose Modulation Technic 적용시 BMI에 따른 선량 감소율 분석)

  • Kim, Jung Wook;Park, Se Yun;Jo, Young Jun;Park, Jong Yeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.25-28
    • /
    • 2012
  • Purpose : It is important to reduce radiation dose associated with computed tomography (CT) scanning to as low as reasonably achievable (ALARA). With Dose Modulation Technic, user select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. In this paper, we presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of Dose Modulation Technic depending on Body Mass Index(BMI). Materials and Methods : In this study, 149 patients were examined(The mean age : $58{\pm}12.4$ years old). Biograph True Point 40 (Siemens, USA) and Gemini TF 64 (Philips. Cleveland) were used for equipment. When we used Care Dose 4D (Siemens, USA) and D-dom (Philips, Cleveland), we measured dose reduction and Computed Tomography Dose Index (CTDI) depending on BMI. Then we analyze data using SPSS Ver.18. Results : When we used Care Dose 4D, p-value is considered statistically significant by groups with the result that we compared Care Dose 4D with D-dom. On the other hand, p-value isn't considered statistically significant by groups using D-dom. Conclusion : Dose modulation based on the projection angle didn't affect degree of obesity. And When using Care Dose 4D, dose reduction rate in the normal patients were higher than the obese. In this study, there are errors on somato type. So I think more research have to be done. Then application of Dose Modulation technic can help in maintaining acceptable image quality while reducing radiation dose by 20-60% in most instances.

  • PDF

Evaluation of Contrast and Resolution on the SPECT of Pre and Post Scatter Correction (산란보정 전, 후의 SPECT 대조도 및 분해능 평가)

  • Seo, Myeong-Deok;Kim, Yeong-Seon;Jeong, Yo-Cheon;Lee, Wan-Kyu;Song, Jae-Beom
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.127-132
    • /
    • 2010
  • Purpose: Because of limitation of image acquisition method and acquisition time, scatter correction cannot perform easily in SPECT study. But in our hospital, could provide to clinic doctor of scatter corrected images, through introduction of new generation gamma camera has function of simple scatter correction. Taking this opportunity, we will compare scatter corrected and non-scatter corrected image from image quality of point of view. Materials and Methods: We acquisite the 'Hoffman brain phantom' SPECT image and '1mm line phantom' SPECT image, each 18 times, with GE Infinia Hawkeye 4, SPECT-CT gamma camera. At first, we calculated each contrast from axial slice of scatter corrected and non-scatter corrected SPECT image of 'Hoffman brain phantom'. and next, calculated each FWHM of horizontal and vertical from axial slice of scatter corrected and non-scatter corrected SPECT image of '1mm line phantom'. After then, we attempted T test analysis with SAS program on data, contrast and resolution value of scatter corrected and non-scatter corrected image. Results: The contrast of scatter corrected image, elevated from 0.3979 to 0.3509. And the resolution of scatter corrected image, elevated from 3.4822 to 3.6375. p value were 0.0097 in contrast and <0.0001 in resolution. We knew the fact that do improve of contrast and resolution through scatter correction. Conclusion: We got the improved SPECT image through simple and easy way, scatter correct. We will expect to provide improved images, from contrast and resolution point of view. to our clinic doctor.

  • PDF

VCUG Studies on the Clinical Usefulness of Aids (VCUG 보조기구의 임상적 유용성에 관한 고찰)

  • Choe, Dea yeon;Kim, Dong hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.529-533
    • /
    • 2015
  • VCUG(Voiding Cystourethrography) study is being performed to check urinary reflex symptom from bladder to ureter or kidney in the method of filling the bladder with radiation opaque contrast agent. However, VCUG study have been performed impersonally, patients have to be naked and open their legs and then void. This method is so impersonal that it is immediately needed to improve the way of testing and crete new aid. Therefore, this study through producing underwear for VCUG, analysis and compares the test time of VCUG, patient radiation dose and patient satisfaction. The target of this study was 79 Male and Female patients who visited genitourinary clinic of PNUYH for their VCUG tests AXIUM Iconos R200(Siemens Medical System : Germany) and self-produced plastic underwears made by vinyl and plasic molding machine were used. The 79 patient were divided into two groups : experiment of patient and comparison group of we patient (using aid) in order to compare, testing time, DAP (dose area product) and patient satisfaction. There was time reduction, from 35.3min of comparison group to 27.8min experimentation group by 7.5min decrease. And comparison group of $4566.6{\mu}Gym^2$(DAP) decreased experimental group (using aid) of $3411.9{\mu}Gym^2$ by $1154.7{\mu}Gym^2$. In the case of patients satisfaction study, anxiety had a drop by 3.45 of comparison group to 2.51 experimentation group by 0.94 decrease. in experimental group. And shame had a drop by 4.02 of comparison group to 3.08 experimentation group by 0.94 increase. in experimental group. Difference of the smooth voiding had a drop by 1.90 of comparison group to 2.84 experimentation group by 0.94 increase. in experimental group. In addition satisfaction had a rise by 1.19 in experimental group. There were also other opinions of uncomfortableness on it and troublesome to wear. VCUG is one of the sensitive care required test. Therefore staff and the aid can give patients such comfortable and the aid can consentive on voiding. As a result test time and DAP can be reduced. It is needed to make testing at more comfortable for patients.

Experimental Studies on Lead Toxicity in Domestic II. Histopathology (고양이의 납중독에 관한 실험적 연구 2. 조직병리학적 소견)

  • Hong Soon-Ho;Han Hong Ryul
    • Journal of Veterinary Clinics
    • /
    • v.11 no.1
    • /
    • pp.485-505
    • /
    • 1994
  • Lead toxicity was evaluated in forty-five cats on a balanced diet, treated with 0(control), 10, 100(low), 1, 000, 2, 000 and 4, 000(high)ppm of lead acetate orally on a body weight basis. The objectives were to describe the gross and histopathologic changes and to demonstrate what tissue lead concentrations correlate with the known dosages of lead. In subclinical lead toxicity, greater than 80% of the absorbed lead was deposited in the bone, whereas in more acute lead toxicity, 42% of absorbed lead was deposited in the bone and 36% and 20% of absorbed lead was deposited in the kidneys and in the liver, respectively. No gross lesions were found in the nervous system. Yellow-brown colored livers appear to be associated with lead toxicity. Neuronal necrosis in the cerebrum was the most predominant histopathologic finding. Astrocytic proliferation in the cerebral gray matter was observed in 1 high dose cat. Gliosis was noted in the cerebral cortex of 6 high dose cats. Two high dose cats had demyelination in the deepest layer of the cortical gray matter of the cerebrum. Extravasation of red cells and cavitation around the vessels were found in the cerebrum of 1 high dose cat. Six high dose cats had degeneration of Purkinje cells in the cerebellum. The microscopic findings in the peripheral nerves were ambiguous. In more acute toxicity, the cats had lead inclusions in the epithelial cells of proximal tubules of the kidneys of 7 cats and hepatocytes of the liver of S cats. These inclusions could be seen wlth H&E, but were more prominent with orcein staining. Two high dose cats had granulomas and connective tissue hyperplasia between tubules of the kidneys. Periportal hepatocyte vacuolization was observed in the liver of 22 cats. Vacuolization of seminiferous tubules and a reduced number of spermatogonia(indicative of reduced spermatogenesis) were found in the testis of 5 treated cats. Cystic ovaries were observed in 3 high dose cats and poor development of oogonia was found in 2 cats. The diagnosis of lead toxicity in cats can be suspected on the basis of the histopathologic lesions described, and can be of value in contributing to a diagnosis. A reliable diagnosis of lead poisoning can be helped utilizing tissue lead analysis(post molten)

  • PDF

A Study on the Analysis and Efficiency of Police Budget (경찰의 예산분석 및 효율화 방안에 관한 연구)

  • Park, Jong-Seung;Kim, Chang-Yun
    • Korean Security Journal
    • /
    • no.38
    • /
    • pp.7-32
    • /
    • 2014
  • This study is aimed to analyze problems of police budgetary execution and to suggest better ways for establishing effective budget implementation as well as legitimacy of securing budget in the field of police work. For this purpose, this paper analyzed the annual reports on police budgetary execution, from 2009 to 2012, conducted by National Assembly Budget Office. In result, most parts of the police budgetary execution were not satisfied with the audit standard, and especially in terms of management of budgetary execution, it showed 40% in inappropriateness. In addition, excessive and underestimate appropriation in the police budgetary execution, which happened frequently in other offices, was recorded on the second place. 10% of the amount of budget was executed for ordinance violence. Given results analyzed from each division, Transportation Division occupied 40% of the amount of related problems and all of types in the field did not meet the audit standard, thus it is required to manage budgetary execution effectively. In terms of Public Safety Division, the problem was related to budgetary allocation prior to execution, such as overlap in other works, excessive and underestimate appropriation, and inappropriate business plans. Director General for Planning and Coordination did not meet the standard of law system maintenance, Given the light of the result of analyzing programs, traffic safety and securing communication was the most problematic and support for police administration, crime prevention and protecting the disadvantaged, educating professional police officers, and establishment of policing infrastructure were required to be reformed in sequence. In order to resolve these problems, it is demanded to check budgetary execution and the process in business plans on a regular basis. Additionally, in case of using budget in inappropriate parts, tough penality including reduction of budget in related to the local police should be implemented to increase the importance of budgetary execution. Moreover, because of the fact that a part of problem of budgetary execution was originally caused by the budgetary allocation, it is advised to allocate police budget using the budget proposal of National Finance Act and Ministry of Strategy and Finance.

  • PDF