• Title/Summary/Keyword: Analysis of building energy performance

Search Result 567, Processing Time 0.027 seconds

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

Case Study for Energy Conservation Measures of Hospital Buildings Using the Analysis of Energy Consumption Structure (의료시설 에너지절약 운영방법 도출을 위한 사례분석을 통한 에너지 영향요소 분석)

  • Lee, Sangmoon;Cho, Jinkyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.2
    • /
    • pp.57-69
    • /
    • 2019
  • Because the hospital building operates 24 hours a day, 365 days a year for treatment and restoration of patients, it has a different pattern of energy use than that of ordinary buildings. Hospitals contribute to energy consumption and have a negative environmental impact. This study aims to find how meaningful energy performance, reflecting good energy management and ECMs, can be operated for hospital buildings, a category encompassing complex buildings with different systems and large differences between them. In this study, we proposed the energy diagnosis & evaluation method and energy management process to verify energy saving through operation data based on system & facility characteristics, operation pattern and energy consumption characteristics of hospital building. Energy consumption structures were surveyed throughout 4 reference hospital in Seoul, Korea. Findings confirm that different hospital departments have hugely different energy-demand profiles. Energy efficiency and energy saving potentials are presented. The energy performance analysis can be applied to a wide range of problems in energy-system operation.

Thermal performance evaluation of Temperable Low-e glass window through Heating Energy consumption Analysis (난방에너지 사용량 분석을 통한 후강화 로이유리 창호의 단열성능 평가)

  • Jang, Cheol-Yong;Kim, Jeong-Gook;Ahn, Byung-Lip;Kim, Jun-Sup;Haan, Chan-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.200-205
    • /
    • 2012
  • In the high oil price age, intensification of energy efficiency promotion in the building sector is required. Windows are dominating in large percent of whole building loads, and are regarding as the primary target of energy efficiency. In this study, in order to reduce heat loss of buildings, we investigate the thermal performance properties of Temperable Low-e glazing coated Ag membrane that has high electrical conductivity. The Temperable Low-e glazing windows has high insulation and shading properties, and it has strength that can supply various product which consumers want. In order to evaluate thermal performance of temperable windows, we install single low-e windows and double low-e windows in the experimental chamber and analysis the comparison heating energy consumption between single and double Low-e glazing windows. performance evaluation was conducted.

  • PDF

Energy Performance and Operating Cost Assessment for Implementing Green Remodeling Technologies in a Detached House (단독주택 건물 그린리모델링에 따른 건물 에너지 성능과 운전비용 절감 효과 평가)

  • Byonghu Sohn;Su-In Lee;Jae-Sik Kang
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.19 no.4
    • /
    • pp.27-38
    • /
    • 2023
  • The Government the Republic of Korea is showing a lot of interest in net zero-energy buildings (NZEBs) to reduce energy consumption of buildings and to promote green growth policy in construction sector. The application of building passive technologies and renewable energies is essential to achieving NZEBs. Green remodeling reinforced the insulation of the exterior walls and roofs of the buildings and replaced high-efficiency windows and doors. In this study, the energy performance before and after green remodeling applied in a detached house was comparatively analyzed for baseline scenario and three different ones, ALT 1, ALT 2 and ALT 3. A building modeling and simulation software (DesignBuilder V7.0) with EnergyPlus (V9.4) calculation engine was used to calculate the energy demand and energy consumption for each scenario. Based on the calculation results of the building's energy demand for baseline, it was determined that the target building required more heating energy than cooling energy. The simulation results also showed that the implementation of building envelope performance improvement technologies (ALT 1) could notably decrease the heating energy consumption of the building. After the remodeling (ALT 1), the source energy consumption per unit floor area was assessed to be reduced by 65.2%, compared to prior remodeling of 338.7 kWh/m2 -y. Meanwhile, ALT 2 can achieve energy savings of 67.7% and ALT 3 can achieve savings of 73.1%. Following completion of the remodeling project, actual construction costs, and on-site measurements and verification results will be gathered and compared with the simulation results. Additionally, economic analysis including construction costs and payback period will be conducted using actual site data.

An Analysis of Heating Energy Performance in Housings of ICF Method with Passive Design Applied (패시브 디자인을 적용한 ICF공법 주택의 난방에너지 성능 분석)

  • Kim, Jun-Hui;Lee, Tae-Gu
    • KIEAE Journal
    • /
    • v.13 no.3
    • /
    • pp.33-40
    • /
    • 2013
  • The world population is consuming more than 1/3 of the total energy for heating housings. Particularly in our country, 21% of the consumption energy is occupied by building section. Therefore, it is necessary to increase the energy efficiency in buildings, thus promoting a comfortable residential environment while minimizing energy consumption. Accordingly, this study presents considerations for implementing high-insulated and airtight passive houses. This study selected four houses with passive house design applied, performed building energy performance through PHPP2007, a German passive house design simulation program, and compared the building-specific heat loss and heat gain. As a result, the most vulnerable part to heat loss was turned out to be a window and the heat loss was caused by outer wall, roof, and ventilation. Accordingly, for the implementation of passive house, it is necessary to make a careful plan and airtight construction that are complementary to various parts through the energy performance analysis started from the design phase.

The Feasibility Analysis of Organic Waste Bioenergy System in Apartment Complex (유기성 폐자원 바이오에너지 시스템의 공동주택 적용 타당성 평가에 관한 연구)

  • Ko, Myeong-Jin;Choi, Mi-Young;Choi, Doo-Sung;Kim, Yong-Shik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.474-481
    • /
    • 2010
  • Because international environmental and energy problems such as global warming and ozone depletion, exhausting of fossil energy sources are more serious than before, renewable energy system is attracting people's attention more and more. Organic waste bioenergy system among a variety of renewable energy system is expected to have an effect on building a society which is eco-friendly and recycles resources owing to carbon neutral effects. So this is considered as the role of an energy source of the building. Previous studies on the organic waste bioenergy are mainly bioenergy technology and activation plan of the bioenergy supply. But the performance evaluation studies of bioenergy systems installed in buildings are rarely. This study is to evaluate applicability of the organic waste bioenergy system as the building energy supply system by energy and environmental, economical analysis.

Evaluation on the Cooling Performance of Geothermal-energy Using Heat Pump System in Mixed-use Residential Building (주상복합 건축물에 적용된 지열이용 히트펌프 시스템의 냉방성능 평가)

  • Kim, Yong-Shik;Kim, Jung-Heon;Hwang, Kwang-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.9-16
    • /
    • 2006
  • Geothermal-energy has been getting popular as a natural energy source for green buildings these days. Public building with gross area more than $3000m^2$, planned after March, 2005, should spend about 5% of total building cost for equipment run by natural energy source (e.g. geothermal, solar heat, solar power, etc) according to renewable energy promotion law in Korea. As a result geothermal-energy using heat pump system is emerging as a effective alternative for realistic and economic plan although design guidelines and construction code for the system is in progress and technical data is far from sufficient. The quantitative analysis on the performance of geothermal-energy using heat pump system is insufficient for appropriate design of it. In this paper, cooling performance of geothermal-energy using heat pump system of residential and retail etc. mixed-use building has been analyzed on the basis of temperature comparison between inlet and outlet of heat exchangers of the operating system. Additionally, dry-bulb temperature and relative humidity have been measured and analyzed together as an index of indoor thermal environment.

Development of Simplified Building Energy Simulation Program for Building Energy Performance Analysis (건물에너지 성능 분석을 위한 간이 건물에너지 시뮬레이션 프로그램 개발에 관한 연구)

  • Park, Jong-Il;Kang, Yoon-Suk;Ihm, Pyeong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • There are various types of energy simulation tool to predict both thermal load and energy use. However, the problem about these software is that they have too much input variables and need expert with skills to run the simulation. Therefore, the purpose of this study is to develop the thermal analysis simulation program with input variables which eliminates coordinates of building components instead of using full coordinates by using DOE2. Since the simulation engine of the program is DOE2, the validity of S-DOE is performed by comparing peak heating and cooling load results with VisualDOE and annual energy use results with actual energy use of 1996. The results have shown that there are little difference between VisualDOE and S-DOE. Also it showed that there are little difference between actual energy use and S-DOE energy use results. S-DOE took less time to model a building than VisualDOE. These results reveals that the application of S-DOE have potentials in accurately predicting both energy load and energy use of the building and still have an advantage of taking less time to model a building.

Analysis of Building Energy using Automated Weather System Data (자동 기상관측 자료를 이용한 건축물 에너지 분석)

  • Lee, Kwi-Ok;Kang, Dong-Bae;Lee, Kang-Yoel;Jung, Woo-Sik;Sim, Je-Hean;Yoon, Seong-Hwan
    • Journal of Environmental Science International
    • /
    • v.23 no.3
    • /
    • pp.493-502
    • /
    • 2014
  • EnergyPlus is a whole building energy simulation program that engineers, architects, and researchers use to model energy and water use in buildings. Modeling the performance of a building with EnergyPlus enables building professionals to optimize the building design to use less energy and water. This program provides energy analysis of building and needs weather data for simulation. Weather data is available for over 2,000 locations in a file format that can be read by EnergyPlus. However, only five locations are avaliable in Korea. This study intends to use AWS data for having high spatial resolution to simulate building energy. The result of this study shows the possibility of using AWS data for energy simulation of building.

Study on feasibility analysis for ground source heat pump system using the building foundation (건물기초 이용 지열시스템의 도입 타당성 분석에 관한 연구)

  • Chae, Ho-Byung;Nam, Yujin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.155-157
    • /
    • 2013
  • Ground source heat pump(GSHP) systems have been attracted as high-efficient energy-saving technology, but the building clients and designers have hesitated to use GSHP systems which is a expensive initial installation and a uncertain economic feasibility. Therefore In order to reduce the initial cost, many researchers have focused on the energy-pile system using the structure of the building as a heat exchanger. Even though many of experimental studies for energy pile system have been conducted, there was not enough data of a quantitative evaluation with the economic analysis and comprehensive analysis for energy-pile. In this study, the feasibility study for the energy pile system with a barrette pile was conducted by the performance analysis and LCC assessment.

  • PDF