• Title/Summary/Keyword: Analysis frameworks

Search Result 410, Processing Time 0.021 seconds

Development and Integration of Various System Design Frameworks (시스템 설계 프레임워크의 개발 및 효율적 통합방안)

  • 김우현;이재우
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.81-86
    • /
    • 2004
  • For the development of system framework which provides multidisciplinary design environment, the integration of analysis codes written in various computer languages, the integration of CAD and DBMS, and the development of complex GUI are indispensible In this study, three different design frameworks which have been developed in Konkuk University with the aids of a company and other university, are compared and analyzed with respect to the analysis code integration method and the module interface technique. Moreover, the way to develop an efficient framework is proposed.

  • PDF

Field Survey and Structural Safety Analysis of Pipe Framed Greenhouses (파이프 골조 온실의 구조 실태 및 안전성 검토(농업시설))

  • 남상운;김문기;유인호
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.315-320
    • /
    • 2000
  • An investigation and structural safety analysis was conducted to get the basic data for establishing maintenance strategy of pipe framed greenhouses. The number of greenhouses investigated was 108 in total. Most multi-span greenhouses had narrower width and lower height than the standard 1-2W greenhouse, and most of single-span greenhouses were tunnel type. In multi-span greenhouses, the size and interval of frameworks such as rafter, purline, column, and cross beam were mostly suitable, but frameworks of single-span greenhouses were mostly insufficient.

  • PDF

Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques

  • Kocaagaoglu, Hasan;Albayrak, Haydar;Sahin, Sezgi Cinel;Gurbulak, Aysegul Guleryuz
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.5
    • /
    • pp.262-270
    • /
    • 2019
  • PURPOSE. The purpose of this in vitro study was to evaluate the marginal misfits of three-unit frameworks fabricated with conventional and digital impressions techniques. MATERIALS AND METHODS. Thirty brass canine and second premolar abutment preparations were fabricated by using a computer numerical control machine and were randomly divided into 3 groups (n=10) as follows: conventional impression group (Group Ci), Cerec Omnicam (Group Cdi), and 3shape TRIOS-3 (Group Tdi) digital impression groups. The laser-sintered metal frameworks were designed and fabricated with conventional and digital impressions. The marginal adaptation was assessed with a stereomicroscope at ${\times}30$ magnification. The data were analyzed with 1-way analysis of variances (ANOVAs) and the independent simple t tests. RESULTS. A statistically significant difference was found between the frameworks fabricated by conventional methods and those fabricated by digital impression methods. Multiple comparison results revealed that the frameworks in Group Ci (average, $98.8{\pm}16.43{\mu}m$; canine, $93.59{\pm}16.82{\mu}m$; premolar, $104.10{\pm}15.02{\mu}m$) had larger marginal misfit values than those in Group Cdi (average, $63.78{\pm}14.05{\mu}m$; canine, $62.73{\pm}13.71{\mu}m$; premolar, $64.84{\pm}15.06{\mu}m$) and Group Tdi (average, $65.14{\pm}18.05{\mu}m$; canine, $70.64{\pm}19.02{\mu}m$; premolar, $59.64{\pm}16.10{\mu}m$) (P=.000 for average; P=.001 for canine; P<.001 for premolar). No statistical difference was found between the marginal misfits of canine and premolar abutment teeth within the same groups (P>.05). CONCLUSION. The three-unit frameworks fabricated with digital impression techniques showed better marginal fit compared to conventional impression techniques. All marginal misfit values were clinically acceptable.

Evaluation of trueness and precision of removable partial denture metal frameworks manufactured with digital technology and different materials

  • Leonardo Ciocca;Mattia Maltauro;Elena Pierantozzi;Lorenzo Breschi;Angela Montanari;Laura Anderlucci;Roberto Meneghello
    • The Journal of Advanced Prosthodontics
    • /
    • v.15 no.2
    • /
    • pp.55-62
    • /
    • 2023
  • PURPOSE. The aim of this study is to evaluate the accuracy of removable partial denture (RPD) frameworks produced using different digital protocols. MATERIALS AND METHODS. 80 frameworks for RPDs were produced using CAD-CAM technology and divided into four groups of twenty (n = 20): Group 1, Titanium frameworks manufactured by digital metal laser sintering (DMLS); Group 2, Co-Cr frameworks manufactured by DMLS; Group 3, Polyamide PA12 castable resin manufactured by multi-jet fusion (MJF); and Group 4, Metal (Co-Cr) casting by using lost-wax technique. After the digital acquisition, eight specific areas were selected in order to measure the Δ-error value at the intaglio surface of RPD. The minimum value required for point sampling density (0.4 mm) was derived from the sensitivity analysis. The obtained Δ-error mean value was used for comparisons: 1. between different manufacturing processes; 2. between different manufacturing techniques in the same area of interest (AOI); and 3. between different AOI of the same group. RESULTS. The Δ-error mean value of each group ranged between -0.002 (Ti) and 0.041 (Co-Cr) mm. The Pearson's Chi-squared test revealed significant differences considering all groups paired two by two, except for group 3 and 4. The multiple comparison test documented a significant difference for each AOI among group 1, 3, and 4. The multiple comparison test showed significant differences among almost all different AOIs of each group. CONCLUSION. All Δ-mean error values of all digital protocols for manufacturing RPD frameworks optimally fit within the clinical tolerance limit of trueness and precision.

Distribution of Mobile Apps Considering Cross-Platform Development Frameworks in Android Environment (안드로이드 환경에서 크로스 플랫폼 개발 프레임워크에 따른 모바일 앱 분포)

  • Kim, Gyoosik;Jeon, Soyeon;Cho, Seong-je
    • Journal of Software Assessment and Valuation
    • /
    • v.15 no.1
    • /
    • pp.11-24
    • /
    • 2019
  • Using cross-platform development frameworks, mobile app developers can easily implement mobile apps for multiple platforms in one step. The frameworks also provides adversaries with the ability to write malicious code once, and then run it anywhere for other platforms. In this paper, we analyze the ratio of benign and malicious apps written by cross-platform development frameworks for Android apps collected from AndroZoo's site. The analysis results show that the percentage of benign apps written in the frameworks continues to increase, accounting for 45% of all benign apps in 2018. The percentage of malicious apps written in the frameworks accounted for 25% of all malicious apps in 2015, but that percentage has declined since then. This study provides useful information to make a suitable choice when app developers face several challenges in cross platform app development.

Identifying Tools for Systemic Teaching Analysis in Higher Education

  • ROH, Hyelan;CHOI, Mina;SEO, Youn-Kyung
    • Educational Technology International
    • /
    • v.8 no.2
    • /
    • pp.73-91
    • /
    • 2007
  • The purpose of this study is to explore tools for systemic and integrated teaching analysis in recognition of problems derived from the existing teaching analysis which have been held fragmentarily and temporarily. In order to do so, a teaching analysis tools is identified by examining the current services of video-taping and analysis, which are the most representative teaching analysis methods among the Centers for Teaching and Learning (CTLs) in Korea, and by redefining teaching analysis through literature review. A teaching analysis is to be done to challenge teachers to change and grow by providing a motive to reflect on the act of teaching and carry out improvements, and it has to be held covering the general act of teaching and examined through diverse methods in systemic and multidimensional perspectives over a full period of teaching. In this study, an act of teaching is examined in four areas: planning, teaching skill, evaluation and reflection, and teaching analysis frameworks according to an act of teaching are suggested by periods of before, during, and after a term. Teaching analysis methods are also suggested by the frameworks.

A Study on Stiffness-based Optimal Design of Tall Plane Frameworks using Composite Member (합성부재를 이용한 고층평면골조의 강성최적설계에 관한 연구)

  • Kim, Ho-Soo;Lee, Han-Joo
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.3 s.13
    • /
    • pp.77-84
    • /
    • 2004
  • This study presents an effective stiffness-based optimal technique to control quantitatively lateral drift for tall frameworks using composit member subject to lateral loads. To this end, displacement sensitivity depending on behavior characteristics of tall frameworks is established and approximation concept that preserves the generality of the mathematical programming and can efficiently solve large scale problems is introduced. Specifically, under the 'constant-shape' assumption, resizing techniqe of composite member is developed. Two types of 50 story frameworks are presented to illustrate the features of the quantitative lateral drift control technique proposed in this study.

  • PDF

Value Chain Analysis: A Brief Review

  • Zamora, Elvira A.
    • Asian Journal of Innovation and Policy
    • /
    • v.5 no.2
    • /
    • pp.116-128
    • /
    • 2016
  • Value chain analysis has been applied in various fields, from the time the concept of “value chain” was introduced by Porter in 1985. Several frameworks have emerged and have been used to study individual firms, entire industries, industry clusters, as well as global production networks. The purpose of this paper is to provide a brief review of these frameworks, identify factors that influence the performance of value chains, and suggest areas for future research. Since there is a wide range of value chain literature, this paper focuses on a selective set of earlier works within the value chain model as conceptualized by Porter. The study takes note of the many dimensions and applications of value chain analysis, and shows that value chain analysis is an effective way to examine the interaction among different players in a given industry. The study further points out the shortcomings of the traditional or Porter view of value chain analysis.

Privacy-Aware Adaptable Web Services Using Petri Nets

  • Song, You-Jin;Yim, Jae-Geol
    • Journal of Information Processing Systems
    • /
    • v.5 no.1
    • /
    • pp.19-24
    • /
    • 2009
  • Many researchers have developed frameworks that are capable of handling context information and can be adapted and used by any Web service. However, no research involving the systematic analysis of existing frameworks has yet been conducted. This paper examines the Context Framework, an example of existing frameworks, using a Petri net, and analyzes its advantages and disadvantages. Then, a Petri net model - with its disadvantages removed - is introduced, and a new framework is presented on the basis of that model. The proposed PAWS (Privacy Aware Web Services) framework has a expendability for context management and communicates flexible context information for every session. The proposed framework can solve overhead problems of context in SOAP messages. It also protects user privacy according to user preferences.

Considerations for the Survival of Complete Arch Implant-Supported Zirconia Restorations; Status of Antagonistic Arches and Stress Distribution on Frameworks: A Case Report

  • Choi, Jung-Yoo;Sim, Jae-Hyuk;Yeo, In-Sung Luke
    • Journal of Korean Dental Science
    • /
    • v.10 no.2
    • /
    • pp.74-81
    • /
    • 2017
  • This report describes two cases of complete arch implant-supported restorations. The first patient had seven dental implants in each arch with monolithic zirconia frameworks. At four weeks' follow-up, the one-piece maxillary framework was fractured, which was re-designed and re-fabricated using laser-sintered cobalt-chrome alloy. The second patient had four implants in the mandible only. A mandibular monolithic zirconia framework and a maxillary conventional complete denture were fabricated and delivered. At five years' follow-up, the patient reported no significant discomfort. Careful consideration and monitoring of the status of antagonistic arches and stress distribution on zirconia frameworks were suggested for complete arch implant-supported fixed restorations.