• 제목/요약/키워드: Amplitude-Comparison

검색결과 426건 처리시간 0.027초

동해 울릉분지 해저 모방 반사면의 AVO 분석을 통한 가스하이드레이트 농도 예측 (Estimation of gas-hydrate concentrations from amplitude variation with offset (AVO) analysis of gas-hydrate BSRs in the Ulleung Basin, East Sea)

  • 이보연;이광훈;류병재;유동근;정부흥;강년건
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.676-679
    • /
    • 2009
  • The bottom-simulating reflector (BSR) is the most commonly observed seismic indicator of gas hydrate in the Ulleung Basin, East Sea. We processed ten representative seismic reflection profiles, selected from a large data set, for amplitude variation with offset (AVO) analysis of the BSR to estimate gas-hydrate concentrations. First, BSRs were divided into five groups based on their seismic amplitudes and associated sediment types: (1) very high-amplitude BSRs in turbidite/hemipelagic sediments, (2) high-amplitude BSRs in debris-flow deposits, (3) moderate-amplitude BSRs in turbidite/hemipelagic sediments, (4) very low-amplitude BSRs in debris-flow deposits, and (5) very low-amplitude BSRs in seismic chimneys. The AVO responses of the group 1 and 3 BSRs are characterized by a rapid decrease and a relatively slow decrease in magnitude with offset, respectively. The AVO response of the group 2 BSR is characterized by a relatively slow increase in magnitude with offset. The AVO responses of the groups 4 and 5 BSRs are characterized by a flat AVO with very small zero-offset amplitude. Theoretical AVO curves, based on the three-phase Biot theory, suggest that the group 1 and 3 BSRs may be related to high (> 40%) concentrations of gas hydrate whereas the group 2 BSRs may indicate low (< 20%) concentrations of gas hydrate. The AVO responses of the group 4 and 5 BSRs cannot be compared with the theoretical models because of their very small zero-offset amplitudes. The comparison of the AVO response of the BSR at the UBGH-04 well with theoretical models suggests about 10% gas-hydrate concentration above the gas-hydrate stability zone.

  • PDF

T6 열처리 및 저온 장시간 등온 시효한 Mg-Al 합금의 경도 및 진동감쇠능 비교 (Comparison of Hardness and Damping Capacities of Mg-Al Alloy Subjected to T6 Heat Treatment and Low Temperature Long Term Isothermal Aging)

  • 전중환
    • 열처리공학회지
    • /
    • 제36권5호
    • /
    • pp.277-284
    • /
    • 2023
  • Hardness and damping characteristics of fine discontinuous precipitates (DPs) microstructure generated by low temperature long term isothermal aging were investigated in comparison with those of T6 heat-treated microstructure composed of DPs and continuous precipitates (CPs) in Mg-9%Al alloy. In this study, T6 and fine DPs microstructures were obtained by isothermal aging at 453 K for 24 h and at 413 K for 336 h, respectively, after solution treatment at 693 K for 24 h. The DPs microstructure exhibited higher hardness than the T6 microstructure, which is related to the lower (α + β) interlamellar spacing of the DPs. The DPs microstructure possessed better damping capacity than the T6 microstructure in the strain-amplitude independent region, whereas in the strain-amplitude dependent region, the reverse behavior was observed. The damping tendencies depending on strain-amplitude were discussed based on the microstructural features of the T6 and DPs microstructures.

Comparison of the Determinants in the Differences in Force-Frequency Relationships between Rat and Rabbit Left Atria

  • Ko, Chang-Mann;Kim, Soon-Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제4권5호
    • /
    • pp.417-425
    • /
    • 2000
  • The underlying mechanism commonly applicable for both the positive and negative force-frequency relationships (FFR) was pursued in left atria (LA) of rat and rabbit. The species differences in the roles of $Na^+/Ca^{2+}$ exchanger and sarcoplasmic reticulum (SR), which are major intracellular $Ca^{2+}$ regulatory mechanisms in the heart, were examined in the amplitude accommodation to the frequency that changed from 3 Hz to the variable test frequencies for 5 minutes in the electrically field stimulated left atria (LA) of rat and rabbit. Norepinephrine strongly increased the frequency-related amplitude accommodation in both of rat and rabbit LA, while monensin, oubain or the reduced $Na^+$ and 0 mM $Ca^{2+}$ containing Tyrode solution increased the frequency-related amplitude accommodation only in the rabbit LA. Monenisn was also able to increase the frequency-related amplitude accommodation only in 1-day old rat LA but not in 4-week old rat LA that had 75% less $Na^+/Ca^{2+}$ exchanger with 97% higher SR than 1-day old rat LA. Taken together, it is concluded that the differences in the prevalence between myocardial $Na^+/Ca^{2+}$ exchanger and SR in the amplitude accommodation to the frequency-change determine the difference in the FFR between rat and rabbit heart.

  • PDF

공압제진대용 이중챔버형 공압스프링의 복소강성 모형화 (Amplitude-dependent Complex Stiffness Modeling of Dual-chamber Pneumatic Spring for Pneumatic Vibration Isolation Table)

  • 이정훈;김광준
    • 한국소음진동공학회논문집
    • /
    • 제18권1호
    • /
    • pp.110-122
    • /
    • 2008
  • Pneumatic vibration isolator typically consisting of dual-chamber pneumatic springs and a rigid table are widely employed for proper operation of precision instruments such as optical devices or nano-scale equipments owing to their low stiffness- and high damping-characteristics. As environmental vibration regulations for precision instruments become more stringent, it is required to improve further the isolation performance. In order to facilitate their design optimization or active control, a more accurate mathematical model or complex stiffness is needed. Experimental results we obtained rigorously for a dual-chamber pneumatic spring exhibit significantly amplitude dependent behavior, which cannot be described by linear models in earlier researches. In this paper, an improvement for the complex stiffness model is presented by taking two major considerations. One is to consider the amplitude dependent complex stiffness of diaphragm necessarily employed for prevention of air leakage. The other is to employ a nonlinear model for the air flow in capillary tube connecting the two pneumatic chambers. The proposed amplitude-dependent complex stiffness model which reflects dependency on both frequency and excitation amplitude is shown to be very valid by comparison with the experimental measurements. Such an accurate nonlinear model for the dual-chamber pneumatic springs would contribute to more effective design or control of vibration isolation systems.

신경 신장 적용 강도에 따른 신경흥분성 변화 (Changes in Nerve Excitability Depending on Intensity of Neural Stretching)

  • 김종순
    • PNF and Movement
    • /
    • 제19권2호
    • /
    • pp.195-203
    • /
    • 2021
  • Purpose: Neurodynamic tests are used to examine neural tissue in patients with neuro-musculoskeletal disorders, although this has not yet been established in the intensity of nerve tension application. This study aimed to investigate the acute effects of neural stretching intensity on nerve excitability using the latency and amplitude of nerve conduction velocity test (NCV) analysis. Methods: Thirty young, healthy male and female subjects (mean age = 21.30 years) voluntarily participated in this study. Nerve excitability was assessed using the median sensory NCV test. The latency and amplitude of the NCV test were measured under four different conditions: reference phase (supra-maximal stimulus, without neural stretching), baseline phase (2/3 of the supra-maximal stimulus, without neural stretching), weak stretch phase (2/3 of the supra-maximal stimulus, with weak neural stretching), and strong stretch phase (2/3 of the supra-maximal stimulus, with strong neural stretching). Results: The NCV latency was significantly delayed after one minute of neural stretching at the baseline, weak phase, and strong phase in comparison with the reference phase. The NCV latency was significantly delayed by increasing the strength of neural stretching. Furthermore, the NCV amplitude was significantly increased at the weak and strong phases, which were under neural stretching, in comparison with the baseline phase. The NCV amplitude was significantly increased by increasing the strength of the neural stretching. Conclusion: Transient neural stretching as a neurodynamic test can increase the sensitivity of the nerve without negatively affecting the nervous system. However, based on the results of this study, strong neural stretching in the neurodynamic test may delay the transmission of nerve impulses and hypersensitivity.

모노펄스 센서에 대한 점 잡음 재밍 기법의 효과도 분석 (An Analysis of Spot Noise Jamming Technique in a Monopulse Sensor)

  • 이성현;정남훈;최영익;홍상근;오승섭;나인석;이창훈;김경태
    • 한국전자파학회논문지
    • /
    • 제28권3호
    • /
    • pp.237-245
    • /
    • 2017
  • 본 논문에서는 우선, 진폭 비교 모노펄스(amplitude comparison monopulse) 방식으로 표적을 추적하는 모노펄스 센서(monopulse sensor)를 모델링하여 부가적인 방해 신호가 없는 경우, 표적에 대한 원활한 추적이 가능하도록 모델링하였다. 그 후, 여러 점 잡음 재밍(spot noise jamming) 시나리오들에 대한 시뮬레이션을 수행하여 모노펄스 센서의 각도 추정 결과 및 운동 궤적을 비교 및 분석하였다. 결과적으로, 본 연구를 통해 모노펄스 센서에 대한 점 잡음 재밍 기법의 효과적인 성능 분석이 가능하였다.

현장실험을 통한 저진동·저소음 진폭가변형 진동해머 성능 평가 (Performance Evaluation of the Vibro Hammer with Variable Amplitude by Field Tests)

  • 한진태;이준용;최창호;박정열
    • 한국지반신소재학회논문집
    • /
    • 제14권3호
    • /
    • pp.1-12
    • /
    • 2015
  • 국내외에서 차수벽이나 흙막이 벽체로 많이 사용되고 있는 강널말뚝의 관입시 일반적으로 진동해머를 이용하여 시공하고 있다. 진동해머 중에서도 유압식 진동해머가 많이 사용되고 있는데, 진동해머의 시동을 켜고 끌 경우 진동해머 편심축의 이동에 따라 고유진동수의 변화로 진동해머에서 공진이 일어나 진동 및 소음이 크게 발생하는 문제점이 있다. 이에 본 연구에서는 일반 유압식 진동해머에서 발생하는 공진 발생에 의한 진동 및 소음을 줄이기 위하여 진폭가변형 유압진동해머를 개발하였다. 개발된 진폭가변형 유압진동해머는 두 쌍의 편심체 수평 각도를 조절하여 진동수 및 진폭을 조절할 수 있으며, 일반 유압식 진동해머와 개발된 진폭가변형 유압진동해머의 기진체 현장실험을 이용한 성능 평가 비교를 통해, 기존 일반 유압식 진동해머에 비해 진폭가변형 유압진동해머의 진동 및 소음이 감소함을 확인하였다. 또한 현장실험 결과 진폭가변형 유압진동해머는 굴삭기의 추력으로 인해 기존 전기식 진동해머에 비해 관입속도가 증가하였으며, 일반 유압식 진동해머에 비해서도 진폭가변으로 지반조건에 따라 관입속도가 빨라질 수 있음을 확인하였다.

Amplitude Correction Factors of KVN Observations Correlated by DiFX and Daejeon Correlators

  • Lee, Sang-Sung
    • 천문학회보
    • /
    • 제40권1호
    • /
    • pp.54.1-54.1
    • /
    • 2015
  • We report results of investigation of amplitude calibration for very long baseline interferometry (VLBI) observations with Korean VLBI Network (KVN). Amplitude correction factors are estimated based on comparison of KVN observations at 22 GHz correlated by Daejeon hardware correlator and DiFX software correlator in Korea Astronomy and Space Science Institue (KASI) with Very Long Baseline Array (VLBA) observations at 22 GHz by DiFX software correlator in National Radio Astronomy Observatory (NRAO). We used the observations for compact radio sources, 3C 454.3 and NRAO 512 which are almost unresolved for baselines in a range of 350-477 km. VLBA visibility data of the sources observed with similar baselines as KVN are selected, fringe-fitted, calibrated, and compared in their amplitudes. We found that visibility amplitudes of KVN observations should be corrected by factors of 1.14 and 1.40 when correlated by DiFX and Daejeon correlators, respectively. These correction factors are attributed to the combination of two steps of 2-bit quantization in KVN observing systems and characteristics of Daejeon correlator.

  • PDF

Vibration analysis of high nonlinear oscillators using accurate approximate methods

  • Pakar, I.;Bayat, M.
    • Structural Engineering and Mechanics
    • /
    • 제46권1호
    • /
    • pp.137-151
    • /
    • 2013
  • In this paper, two new methods called Improved Amplitude-Frequency Formulation (IAFF) and Energy Balance Method (EBM) are applied to solve high nonlinear oscillators. Two cases are given to illustrate the effectiveness and the convenience of these methods. The results of Improved Amplitude-Frequency Formulation are compared with those of EBM. The comparison of the results obtained using these methods reveal that IAFF and EBM are very accurate and can therefore be found widely applicable in engineering and other science. Finally, to demonstrate the validity of the proposed methods, the response of the oscillators, which were obtained from analytical solutions, have been shown graphically and compared with each other.

고속철도 유리애자 파손원인을 위한 현장 진동 연구 (A Study on Field Vibration for Fault Cause Analysis of Glass Insulator on High-speed Railway)

  • 김영석;송길목;방선배;김선구;류영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 합동춘계학술대회 논문집 전기물성,응용부문
    • /
    • pp.189-190
    • /
    • 2008
  • This study was investigated a possibility of fault of glass insulator due to vibration on high-speed railway. The proper vibration of 1-glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The proper vibration of strut tube insulator was lowest 170Hz, highest 1.5kHz. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. The surface vibration(V3) amplitude of strut tube insulator was biggest. From the FFT analysis of viaduct and open route, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in comparison with the proper vibration of strut tube insulator, the resonance was not observed. Although the amplitude of insulator is high, the possibility of fault is low because the glass insulator deterioration by the accumulation of vibration do not happen.

  • PDF